Tender For Provision Of Walkway / Interconnection Between Lean Buildings Of Both The Hangars At Cgae Kochi
Tender Value
40 Lakhs
Estimated cost
Bid Submission
02 Aug 2023
0 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
nedumbassery → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Provision Of Walkway / Interconnection Between Lean Buildings Of Both The Hangars At Cgae Kochi
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of brick or PCC block masonry built in cement mortar including all quoins,arches,pillers etc but excluding ashlar facings,dressed stone work and precast concrete articles complete all as specified and as directed. |
| 2 | Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for unreinforced complete all as specified and as directed. |
| 3 | Excavation in trenches not exceeding 1.5 M wide and n. exc 1.5 M depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed. |
| 4 | Material and labour cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling and mass concrete all as specified and as directed. |
| 5 | Material and labour for reinforced cement concrete design mix M-30 using 20 mm graded granite stone aggregate in foundaions including rafts, footings, foundaion beams, plinth beams, bases for columns etc, basement slabs, underreamed piles and mass concrete all as specified and as directed. Note : Reinforcement and form workshall be measured and paid separately. |
| 6 | Material and labour for reinforced cement concrete M-30 design mix using 20 mm graded stone aggregate as in as in beams, cantilever, lintels over 1.5M span etc complete all as specified and as directed. Note : Reinforcement and form workshall be measured and paid separately. |
| 7 | Material and Labour for reinforced cement concreteM30 design mix using 20mm graded stone aggregate in Columns, pillars, piers, posts and struts complete all as specified and as directedNote : Reinforcement and form workshall be measured and paid separately. |
| 8 | Material and labour forRCC M-30 design mix using 20 mm gradedstone aggregate as in slabs supported on wall, beams and columns, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.Note : Reinforcement and form workshall be measured and paid separately. |
| 9 | Material and labour for TMT bars(CRS/HCR), 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed. |
| 10 | Material and Labour for TMT(CRS/HCR) bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and as directed. |
| 11 | Use and waste for form work to sides and soffits of floor or roof beams, beam haunch-ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc,fair finished flat surfaces of concrete all as specified and as directed. |
| 12 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings, and similar work, not exceeding 200 mm thick etc, fair finshed surfaces of concrete (Horizontal or sloping) complete all as specified and as directed. |
| 13 | Use and waste of formwork to sides of foundation footing, forrough finished surfaces, flat complete all as specified and as directed. |
| 14 | Material and Labour for 0.8mm thk GI deck shest confirming to IS-277-1992 as in permanent shuttering over which MS wire mesh shall be laid at 100x100mm grid including egde trim covered with concrete. This metak deck will be supported on structural steel beam with shear stuck (Structural steel like Beam, column, Joist etc and concrete of different grade as per design complete all as specified and as directed by Engr in Charge |
| 15 | Supply and fix rolled mild steel in Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to Fe-410W(Gde E-250) quality Acomplete all as specified and as directed. |
| 16 | Material and Labour for Granite 18 mm thick of any type work (table rubbed and polished including moulding,grindingect), and laidoverin steps, treads jambs, pillars, window- cills, cooking platforms, other plateforms and like inover and including 15 mm thick backing coat in CM 1:4 andpointing in white cement or colour cement(1:2) using marble dust with admixture of pigment to match withshade of granite complete all as specified and directed. NOTE: Material and Labour for rounding to edges of Granite slabs shall be measured and paid separately. |
| 17 | Supply and fix aluminium powder coated frame for doors,windows, ventilators with one or more rebates with joint clip and using rubber beading etc complete all as specified and directed.Note:Glass panel/particle board panel filling shall be measured and paid separately. |
| 18 | Supply and fix Aluminium Powder coated sliding window shutter using aluminium section weighing 0.55kg/m, 20mm thick using standard vertical handle section, interlocking section, top and bottom rails, U channels for all -around for gauge shutters. All sections are of medium weight series of approved makein three track sliding window in whichtwo shuttersof with and including of 4mm thick Modi guard or equivalent float glass and one shutter fixed with inclusive ofstainless steel wire mesh of size 0.30mm nominal dia and average with of aperture 1.40mm, including necessary jointing cleats, glazing clips , good quality bearing rollers, Neoprene rubber Gasket and rubber beadingof any type, screws , aluminium fitting such as Gasket, handle (01 Nos on each shutter), interlocking arrangements complete all as specified and asdirected by Engr in Charge. Note: The quoted rate shall be inclusive of 4mm thickfloat glass and Stainless steel wire cloth. |
| 19 | Supply and fix powder coated aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, and sliding tower bolt 150mm long anodised aluminium snap beading, screws etc. complete all as specified and as directed. |
| 20 | Supply and fix 10mm thick toughened glass, crystal polished in squares exceeding 0.5 Sqm in each pane as cubical cabin /working table top fixed with adhesive of high quality complete all as specified and asdirected by Engineer in Charge. |
| 21 | Supply and fix Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium ally sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.Make: SANDHU, EVEREST |
| 22 | Supply and fixing venetian blind(vertical blind) using nylon fabric of approved colour and size of blind 100mm wide and length as per requirement including powder coated aluminium channel with operating rope etc and making good disturbed surface including removal of old venation blind and its frame complete all as directed. |
| 23 | Supply and Fixing 5.5 mm thick sheet glass ordinary quality in square exceeding 0.5 Sqm in each pane for fixing in aluminium joinery with rubber gasket as specified and as directed. |
| 24 | Supply and fix 5mm thick figured glass, pin headed type andglazing fixed on aluminium jionery with glazing clips in squareexc 0.5 sq. m in each pane complete all as specified and as directed. |
| 25 | Material and Labour for pre-laminated particle board 12 mm thick, interior grade, prelaminated on both side decorative laminationfixed with screws to frame work complete all as specified and directed. |
| 26 | Supply and fix in repairs door closer hydraulically regulated cast iron body, designation No 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 Kg and fixed complete all as specified and as directed. |
| 27 | Supply and fix in 100 mm size mild steel body Mortice lock, vertical type, with 4 brass liver, fixed to aluminium door complete all as specified and as directed. |
| 28 | Material and labour for precast cement concrete solid block masonry using SolidPCC block type C4 exceeding 10 Cm width, built in cement mortar 1:4 all as specified and as directed. |
| 29 | Material and Labour for Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks laid with special adhesive as recommended by manufatures in steel structures of any description and in any position complete all as specified and as directed by Engr in Charge |
| 30 | Material and labour for rendering 15mm on fair faces of brick or concrete surfaces in CM 1:6, finished even and fair without using extra cement complete all as specified and directed. |
| 31 | Material and Labour for rendering 5 mm thick in cement mortar 1: 3 on fair faces of concrete surfaces of ceilingfinished even and smooth with out using extra cement, complete all as specified. |
| 32 | Material and labour for 15 mm thick renderingon brick/concrete surfaces in CM 1:4, finished even and smooth without using extra cement complete all as specified and as directed. |
| 33 | Material and labour for providing 25mm thick plain cement concrete 1:2:4 mix type B0, using 12.5mm graded stone aggregate as in under layer to flooringfinished rough to reiceve toping complete all as specified and as directed. |
| 34 | Material and labour for applying oil based bitumen primer conforming to IS 3384-1986 at 0.20 kg/Sqm on prepared surface and applying of one coat of blown grade hot bitumen 85/25 conforming to IS 702 @ 1.20 kg / sqm and applying roof treatment with APP modified waterproofing membrane weighing not less than 3kg/sqm, reinforced withnon woven polyster matt weighing not less than 160 gm/sqm having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 650N/Sqm cm, tearing strength of 180N(Minimum), applied bytorch-on application including minimum 10 cmover lap and 15 cm end lap and applying of one coat of blown grade hot bitumen 85/25 conforming to IS 702 @ 1.20 kg / sqm over the membrane and then applying solar reflective bituminous aluminiumpaint for thermal insulation @ 0.10 kg/sqm complete all as specified and directed. NOTE:All necessary safety measures shall be ensured by the contractor during execution of work at site and quoted rate shall be deemed to be inclusive of the same. |
| 35 | Material and labour for preparation of new plastered/concrete surfaces of walls, providing one or more coats of Birla white wall care putty to achieve smooth surfaces and applying two coats ofdistemper oil emulsion of approved shade/tint over a coat of compatiable priming paint complete all as specified. |
| 36 | Material and labour for preparation of new plastered/concrete surfaces ofceiling and applying two coats ofacrylic distemperof approved shade/tint over a coat of primerall as specified and as directed. |
| 37 | Materialand Labour for preparation of plastered surfaces of wall and applyingtwo coats of weather proof anti fungal exterior emulsion paint over a coat of primer complete all as specified and as directed. Make: Apex Ultima Protek of Asian/Exel of Nerolac/Weather Coat of Berger |
| 38 | Excavation in post holes (or similar holes) each not exceeding0.5 cum and getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surface in soft/loose soil complete all as specified and directed. |
| 39 | Material and Labour for Plain Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in foundations filling and mass concrete for stays foundation/ filling and mass concrete and removing and depositing surplus concrete to clear off the site complete all as specified and as directed. |
| 40 | Supply and Fixing Mild steel work such as joist, channel, angle or tee section fixing independentlywithout connecting plates, cut to ordinary length ie, within 20mm of the length indicated conforming to Grade E-250, Fe 410 W quality B all as specified and as directed. |
| 41 | Supply and fix mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washers andone hexagonal or square nut, length of bolt exceeding 15 cm and not exceeding 22.5 cm and dia 11 to 15 mm complete all as specified and as directed. |
| 42 | Supply and fix Mild steel flat iron section as in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165complete all as specified and directed. |
| 43 | Material and Labour for 100mm thick Plain Cement Concrete 1:3:6 type C2 using40 mm graded stoneaggregate as in plinth protection, floors, pavings and hardstanding etc, finished even smooth without using extra cement etc including necessary forwork, complete all as specified and as directed. |
| 44 | Material and Labour for vitrified tiles 10mm thick (square/rectangular) light coloured, area of each tile exceeding 1 sqm and not exceeding 1.5 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed of 15mm thick in CM 1:6 complete all as specified and as directed.Note:- (i) The colour, shade and pattern shall be approved by the GE during execution work. (ii) No extra cost shall be allowed for Removing and refixing and necesary cutting of door etcif any required during execution of work. |
| 45 | Material and Labour for Vitrified tiles 10mm thick (square/rectangular) light coloured as in skirting. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including backing coat of 15mm thick in CM 1:4 complete all as specified and as directed. |
| 46 | Material and labour for seamless plaster of paris false ceiling comprising of Gl frame work with Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including necessary hangers 6mm dia GI adjustable strip suspenders up to 1200mm long fixed to roof slab(using concrete drill) by suitable GI fasten with and including panel for ceiling (12mm thick Plaster of Paris board seamless 1200mmx1800mm size) with self-tapping screw finishing covering the joints with fiber tape and ceiling compound 48 mm wide fibre tape to provide seam less finish and surface finish as specified (particular specification 18.2 ) completely all as specified and as directed.Note: The rate is inclusive of frame work, POP panel and surface finish nothing extra shall be paid on this account |
| 47 | Supply and fix Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including necessary hangers 6mm dia GI up to1200mm length adjusting level fixed to roof slab by means of cleats made out of FI 40x3mm size 60 cm long and expansion holdfast 12.5mm dia 40mm long with and including PVC profile ceiling of surface laminated any pattern and any shade of 7 to 10 mm thickness and any colour completely all as specified and as directed. |
| 48 | Excavation over areas n. exc 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed. |
| 49 | Material and labour for hard core with broken stone or boulders of gauge not exceeding 63 mm, deposited, spread, and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface all as specified and as directed. |
| 50 | Material and Labour for 100mm thick Plain Cement Concrete 1:3:6 type C2 using40 mm graded stoneaggregate as in plinth protection, floors, pavings and hardstanding etc, finished even smooth without using extra cement etc including necessary forwork, complete all as specified and as directed. |
| 51 | Material and labour formachine pressed precast concrete interlocking paver block, any shape and size of 80mm thickness M-40 grade conforming to IS 15658-2006 with grey cement and pigment laid over and including 50mm thick cushion of river sand screen bed, compacted with mechanical surface vibrator complete all as specified and directed. |
| 52 | Supply and fix structural steel work in tubular trusses including special shaped washer complete using ERW or induction butt welded tubes conforming to IS - 1161-1979 grade St.-240 all as specified and as directed. |
| 53 | Material and labour forpreparation of newor previously untreated steel surface over 10 cm width or girth and applying two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 54 | Supply and fixing pre-colour coated high tensile strength galvalume sheet roofing with yield strength (550 MPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer\"s instructions through specialist agency complete all as specified and as directed. |
| 55 | Supply and fixing Pre-painted galvalume aluminum zinc coating GI based Plain sheet roofing with yield strength (550 MPA) prepainted with aluminium (55%) and zinc (45%) alloy coating applied through continous hot dip process having tatal coated thickness (TCT) of 0.50mm with minimum coating mass on both sides @ 150gms/sqm in length and width as per site condition fixed with complete acessories as per manufacturer\"s instructions throughthrough specialist agency and complete all as specified and as directed. |
| 56 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding25 cm complete all as specified and as directed. |
| 57 | Removing excavated soil to a distance not exceeding 50 metre away and depositing where as directed at a level not exceeding 1.5m above the starting point, complete all as specified and as directed. |
| 58 | Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FRLS) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable(FRLS) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-. (a ) onelight point controlled by one switch 5 Amps |
| 59 | Supply and fix Modular switch one way 6A, 1 Module complete all as specified and as directed. |
| 60 | Supply and fixing square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling includingconnecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Make: Havells/ Philips/Bajaj |
| 61 | Supply and fix MCB SP 6-32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed. |
| 62 | Supply and fix MCB SPN 40 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 63 | Supply and fixing distribution board in sheet metal enclosure(CRCA sheet), dust and vermin proof, powder coated, factory made, IP 43 protection, double door type SPN 4 way with 200 Amps, 240 Volt rated copper bus bar neutral and earth connected bars, fixed properly at directed place by using suitable required fixing arrangement complete all as specified and as directed.Note: MCB shall be mesured and paid separately. |
| 64 | Material and labour for Sub main wiring using two runs of single corePVC insulated cable(FRLS) 2.5 sqmm copper conductor multi stranded and one run of 2.5 sqmm copper conductor insulated cable (FRLS)using as earth wire drawn through and including suitable size non metallic rigid PVC conduit not less than 20mm dia with accessories including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note- 3 run of 4 sqmm PVC copper wire and One run of PVC conduitshall be measured and paid as oneunit. |
| 65 | Schedule of Credit (Minus) Rs.2800.00NOTE: Bidder shall insert credit amount of Rs. 2800.00 as ratein Green field under Col-13. |
AI Tender Summary
Tender Timeline
Jul 19, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedAug 02, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 09, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender