Bharat Sanchar Nigam Limited-BSNL has published Tender For Shifting And Itc Ofexisting2 X 7Tr Hpac Package Units From3rd Floor Dwd Ac Pkg Ac Plantmts Bldg Jalandharat1st Floor Mw Bldgofc Ntr Jalandhar.. Submission Date for this Tender is 28-07-2023. Air Conditioner Tenders in Jalandhar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

38701129
Tender For Shifting And Itc Ofexisting2 X 7Tr Hpac Package Units From3rd Floor Dwd Ac Pkg Ac Plantmts Bldg Jalandharat1st Floor Mw Bldgofc Ntr Jalandhar.
Open Tender
Indian
Punjab
Jalandhar
28-07-2023

Tender Details

Shifting And Itc Ofexisting2 X 7Tr Hpac Package Units From3rd Floor Dwd Ac Pkg Ac Plantmts Bldg Jalandharat1st Floor Mw Bldgofc Ntr Jalandhar. 1 Details 2 Dismantling Of Existing7 Tr Package Type Hpac Unit At 3Rd Floor Dwd Ac Plant Room At Mts Bldg Jalandharalong With All Accessories I / C Air Cooled Condensor Units , Refrigerant Piping, Cabling Disconnection From Plenum Etc Complete As Required. 3 Shifting Of 2 Nos 7 Trpackage Type Ac Units Along With All Accessoriesi / C Air Cooled Condensor Units , Refrigerant Piping Etcfrom 3Rd Floor Te Bldg Mts Nagar Jalandharto Ist Floor Ofc Ntrplant Room At Mw Bldg Atte Bldg Mts Nagar Jalandhari / Ccrain Charges For Loading, Unloading, Shifting In Same Bldg , Labour Chargesand Placing The Package Units At Ist Floor In Ac Plant Mw Te Bldg Mts Nagar Complete As Required. 4 Dismantling Of Existingold 7 Tr Package Type Ac Unit Along With All Accessories From Ist Floor Ofc Ntr Ac Plant Mts Nagari / C Air Cooled Condensor Units , Refrigerant Piping, Cabling , Lt Panel , Disconnection From Plenum Etc Complete As Required.& Placing The Equipment At A Suitable Specified Space As Informed By Building Incharge Completeas Reqd. 5 Installation , Testing And Commissioning Of Following Capacities Ac Package Units Complete With All Components , Air Cooled Condenserscharging Of Required Quantity Of Refrigerant , Condensers , Cable Between Units, Lt Panelas Required On The Existing Framework . 6 7 Tr Hp Ac Package Units 7 Supplying & Installing 16 Gauge Hard Drawn Copper Tube Cuting , Bending , Jointing , Brazing Etc. As Required. 8 Hot Gas Line ( Size 5 / 8 ) 9 Liquid Gas Line ( Size 5 / 8 ) 10 Supplying & Fixing Followingsize Xlpe Insulated, Pvc Sheathed Copper Conductor Armoured Cable For Condensor Units On Existing Tray, End Termination Glands, Lugs Etc. As Reqd. 11 3X2.5 Sqmm 12 S / F Ofms Angle Iron Frame Of Following Sizefor Housing Condensor Units Including Cutting, Welding, Grouting And Painting I / C Minor Civil Worketc As Required. 13 50Mmx50mmx5mm 14 Supplyingandinstallingfollowingsizeofperforatedpainted With Powder Coating M.S. Cable Trays With Perforation Not More Than17.5%, Inconvenientsections, Joinedwithconnectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. 15 ( A ) 150Mm Width X 50Mm Depth X 1.6Mm Thickness 16 Dismantling Of Existingsplit Typeac Units Located In Te Bldg Focal Point Jalandhari / C Dismantling Of Indoor Unit, Copper Pipings, Outdoor Units, Pumping Down The Refrigerant, Stands For Outdoor Units And Keeping The Same To A Safe Location As Per The Directions Of The Engineer In Charge. 17 Shifting Of The Already Dismantled 3 Nos Split Type Ac Unitsfrom Te Bldg Focal Point Jalandharto Dwd Ntr Room 3Rd Floor Mts Bldg Jalandhar Complete With Indoor, Outdoor, Cable, Stand, Piping, Insulation Etc. 18 Installation, Testing & Commissioning Of The 1.5 Tr Split Type Ac Unit At Dwd Switch Room 3Rd Floor Mts Bldgby Mounting / Fitting Indoor And Outdoor Units At Their Respective Locations , Laying And Fixing Of Both Liquid And Hot Gas Lines, Inter Connecting Wiring For Both Indooroutdoor Units, Interconnecting The Indoor Unit And Outdoor Unit Withrefrigerant Piping, Insulating The Refrigerant Pipe With Expandable Polyethylene Foam Tubing Unit , Leak Testing Entire System , Charging Existing Refrigerantin Theunit , Making Power Supply Connections From The Existing Power Point Etc Complete As Required. 19 Suppying And Fixing Additional Copper Refrigerant Piping Of Sizes 1 / 2 & 1 / 4 For Liquidand Hot Gasline, Insulating The Refrigerant Pipe With Nitrolon Rubber Sleev Insulation Material , Taping , Clamping I / C Cutting, Bending, Jointing, Brazing, Flaring, Etc Comp.As Reqd. 20 Supplying And Laying 3 Core 2.5 Sqmm Pvc Insulated And Pvc Sheathed Flexible Copper Cable Along With Refrigerant Pipe Or Alongwith Existing Conduit / Cable Tray I / C Binding With Plastic Tags For Extending Supply From Indoor Unit To Outdoor Unit Etc, As Required . ( Make: Any / Isi Mark ) 21 Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32 A 240 V C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 22 S / F 2X 4 Sqmm Size Pvc Insulated Pvc Sheathed Copper Conductor Armouredcable On Wall With The Help Of Saddles I / C Making Interconnection With Existing Db / Ac Etc Complete As Required. 23 Supplying And Fixing Of Mimimum 20Mm Dia. Pvc Pipe Of Supperior Quality For Drainage Water Of Split Type Ac Unitsi / C Elbow, Tee, Socket, Union, Adhesive, Cutting And Jointing Etc. Complete As Required. 24 Provision Of Top Up Of R-22 Gas In Existing Split A.C Unitsi / C Flushing, Testing Etc. As Required. 25 Important Note :- 1 ) Gst Is Implemented. The Tax Will Be Regulated Accordingly And The Credit Will Be Transferred To Bsnl As Per New Rules.2.For Claiming Gst Payment The Vendor Should Raise Gst Invoice As Per Point No. 8 ( Gst Invoice ) Of Vendor Contract Clauses Of This Nit.

Key Value

Document Fees
INR 590 /-
EMD
INR 6142.0 /-
Tender Value
INR 3.07 Lakhs /-

BOQ Items

Name of Work: Shifting and ITC ofexisting2 x 7TR HPAC package units from3rd floor DWD AC Pkg AC PlantMTS bldg jalandharat1st Floor MW bldgOFC NTR Jalandhar.
Sl. No. Item Description
1Details
2Dismantling of existing7 TR package type HPAC unit at 3rd floor DWD AC plant room at MTS bldg jalandharalong with all accessories i/c air cooled condensor units ,refrigerant piping,cabling disconnection from plenum etc complete as required.
3Shifting of 2 nos 7 Trpackage type AC units along with all accessoriesi/c air cooled condensor units ,refrigerant piping etcfrom 3rd floor TE Bldg MTS Nagar jalandharto Ist floor OFC NTRplant room at MW bldg atTE Bldg MTS Nagar jalandhari/ccrain charges for loading,unloading, shifting in same bldg ,labour chargesand placing the package units at Ist floor in AC plant MW TE bldg MTS Nagar complete as required.
4Dismantling of existingold 7 Tr package type AC unit along with all accessories from Ist floor OFC NTR AC Plant MTS Nagari/c air cooled condensor units ,refrigerant piping,cabling ,LT panel ,disconnection from plenum etc complete as required.& placing the equipment at a suitable specified space as informed by building incharge completeas reqd.
5Installation , Testing and commissioning of following capacities ac package units complete with all components , air cooled condenserscharging of required quantity of refrigerant , condensers , cable between units, LT Panelas required on the existing framework .
67 TR HP AC Package units
7Supplying & Installing 16 gauge hard drawn copper tube cuting , bending ,jointing ,brazing etc. as required.
8Hot gas line ( size 5/8")
9Liquid gas line ( size 5/8 ")
10Supplying & fixing followingsize XLPE insulated, PVC sheathed copper conductor armoured cable for condensor units on existing tray, end termination glands, lugs etc. as reqd.
113x2.5 sqmm
12S/F ofMS angle iron frame of following sizefor housing condensor units including cutting, welding, grouting and painting i/c minor civil worketc as required.
1350mmx50mmx5mm
14Supplyingandinstallingfollowingsizeofperforatedpainted with powder coating M.S. cable trays with perforation not more than17.5%,inconvenientsections,joinedwithconnectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
15(a) 150mm width x 50mm depth x 1.6mm thickness
16Dismantling of existingSplit typeAC units located in TE bldg Focal point jalandhari/c dismantling of indoor unit, copper pipings, outdoor units, pumping down the refrigerant, stands for outdoor units and keeping the same to a safe location as per the directions of the engineer in charge.
17Shifting of the already dismantled 3 Nos Split type AC unitsfrom TE bldg Focal point Jalandharto DWD NTR room 3rd Floor MTS bldg Jalandhar complete with indoor, outdoor, cable, stand, piping, insulation etc.
18Installation, Testing & Commissioning of the 1.5 TR Split type AC unit at DWD switch room 3rd floor MTS bldgby mounting/fitting Indoor and Outdoor units at their respective locations , laying and fixing of both liquid and hot gas lines, inter connecting wiring for both indooroutdoor units, interconnecting the indoor unit and outdoor unit withrefrigerant piping, insulating the refrigerant pipe with expandable polyethylene Foam tubing unit , Leak testing entire system ,charging existing refrigerantin theunit , making power supply connections from the existing power point etc complete as required.
19Suppying and fixing additional copper refrigerant piping of sizes 1/2" & 1/4" for liquidand hot gasline, insulating the refrigerant pipe with Nitrolon Rubber Sleev insulation material , taping , clamping i/c cutting, bending, jointing, brazing, flaring, etc comp.as reqd.
20Supplying and laying 3 core 2.5 sqmm PVC insulated and PVC sheathed flexible copper cable along with refrigerant pipe or alongwith existing conduit / cable tray i/c binding with plastic tags for extending supply from indoor unit to outdoor unit etc, as required . ( Make: any/ISI mark)
21Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
22S/F 2X 4 Sqmm size PVC insulated PVC sheathed copper conductor armouredcable on wall with the help of saddles i/c making interconnection with existing DB/ AC etc complete as required.
23Supplying and fixing of mimimum 20mm dia. PVC pipe of supperior quality for drainage water of split type AC unitsi/c elbow, tee, socket, union, adhesive, cutting and jointing etc. complete as required.
24Provision of Top up of R-22 gas in existing Split A.C unitsi/c flushing, testing etc. as required.
25IMPORTANT NOTE :- 1) GST is implemented. The tax will be regulated accordingly and the credit will be transferred to BSNL as per new rules.2.For claiming GST payment the vendor should raise GST invoice as per point No. 8 (GST invoice) of Vendor Contract Clauses of this NIT.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail