Tender For Installation Of New Tubewell Size Of 200Mm Id With 250 Mtr Depth At Water Supply Scheme In Village Ganaru And Gara 2 Nos. Mh Pc Bifurcation From Existing Water Supply Scheme Agampur 05 Nos Block Sri Anandpur Sahib Distt. Rupnagar
Tender Overview
Project Description
Installation Of New Tubewell Size Of 200Mm Id With 250 Mtr Depth At Water Supply Scheme In Village Ganaru And Gara 2 Nos. Mh Pc Bifurcation From Existing Water Supply Scheme Agampur 05 Nos Block Sri Anandpur Sahib Distt. Rupnagar
BOQ
| Sl. No. | Item Description |
| 1 | TUBEWELL |
| 2 | Providing and installing 200 mm i/d straight tubewell drilling of 500 mm (20) of suitable sizeborehole where in stony strata/boulders are some times encounted in this area while dirlling which makes drilling purely by Reverse rotary mehtod immpossible. While mostly is done by Reverse rotary method, but when stony/boulder strata appear, then other methods i.e. direct rotary etc. are used. So drilling by any suitable rig in this area including the cost of consumable store fuel, oil & transportation of rig to the site of proposed bore. Complete in all respect upto full depth (0 to 250 mtr depth BGL).1. Erection and dismantliing of boring plant including all arrangement for the transportation of the boring equipment to site of work from the store of contractor at site and back are to be made by the contractor at his own cost. All rates should be quoted for supplying the material at site of work . Pits for collection of water and water for drilling tubewell be arranged by the firm / contractor at site at his own cost.2. In case the bore is converted into a tubewell payment of bore shall be made up to the bail plug plus margin (7% of main bore drilling or as actual as per field requirement whichever is less) required for sustaining the main bore. The test bore beyond margin shall be paid at the rate of test bore drilling\". |
| 3 | Supplying & lowering MS Pipe as per IS 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strenght to lower the pipe into tubewell bore. |
| 4 | 200mm nominal diameter (wight 41.6 kg per meter) 8.00 mm thickness. |
| 5 | Supplying, lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI Marked, duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore. |
| 6 | 200 mm steel stainer (Slot size 0.75 mm) 8.00mm |
| 7 | Supplying, fixing and lowering of stainless steel socket as per IS 8110: 2000 or latest, ISI marked duly welded with suitable grade SS welding electrode to lower the strainer into tubewell bore complete in all respects. |
| 8 | 200 mm internal diameter |
| 9 | Supplying and fixing of bail plug of M.S. Pipe complete with inverted U-hook attached to the bottom plug complete in all respects. |
| 10 | 200 mm internal diameter (Weight41.6 kg per meter) 8.00 mm thickness. |
| 11 | Supplying & fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects. |
| 12 | Supplying and fixing of well cap having threads to fix on housing pipe complete in all respects. |
| 13 | 200mm internal diameter |
| 14 | Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. |
| 15 | 200mm internal diameter |
| 16 | Supplying and fixing M.S. Clamps of size 150mm x 12mm made out of MS Flat 1.52m long, suitable to fit Housing Pipe including the cost Nut & Bolts of Suitable size complete in all respects. |
| 17 | Supplying at site wooden box of suitable size with Lid & lockign arrangement for preserving strata sample collected from the bore. |
| 18 | Supplying at quarry site of gravel of 1/16\" to 1/8\" sizes including pouring and packing in the annular space between the pipe assembly and the bore. The gravel should be free from, dust, dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) |
| 19 | Development and stabilizing of the tubewell with Air compressor or required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 20 | Capacity of Air Compressor 500 cfm at 150 PSI |
| 21 | Development and stabilizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge. |
| 22 | Collection of water samplefrom different strata and testing of sample from approved laboratory (Physical & chemical Analysis) |
| 23 | Testing of water sample for Heavy metal from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.) |
| 24 | Making electric Logging of borehole with electronic well logger including cost of equipment at site etc.complete in all respect. |
| 25 | Supplying at site Tibba sand etc. including pouring and packing in the annular space between the pipes assembly and the bore above clay seal complete in all respect. |
| 26 | Providing & Fixing Clay seal in graval packminimum 3 Mtr. (As per BIS Cose 2800-2020) |
| 27 | Providing & Fixing Sanitery Seal (As per BIS Cose 2800-2020) |
| 28 | Sterilization of Well (As per BIS Cose 2800-2020) |
| 29 | PUMP CHAMBER |
| 30 | Construciton of pump chamber having 3.05 x 3.70 mtr. plinth area including cost of electric wiring & sanitary installation as per standard design complete in all respect including construction of toilet as per DWSS design & drawing. |
| 31 | PUMPING MACHINERY |
| 32 | Providing, installing, testing and commissioning of 1 no. Electrically driven pumping set of reputed make , capable ofdeleviring 285lpm/4.80lps against a head of 67 mtr.(10 BHP)Complete in all respects |
| 33 | Supplying lowering of 65 mm dia GI pipe as per IS 1239 (B - class) premim makesuch (as Jindal Hisar) including cost of specials such as tees, bends , sockets elbow etc, cutting , treading and testing in trenches in the ground. Complete in all respects |
| 34 | Providing and fixing of submerssible of 4.00 mm ² core cable, complete in all respect |
| 35 | Providing installing, testing and commissioning of1 no. control panelwith closed transition star delta with enclosure consisting of electrical appliances such as contactor, furses, MCCB\"s over load relays, isolator switches wiring and connnections. Complete in all respect. |
| 36 | C.IFITTING INSIDE PUMP CHAMBER |
| 37 | Providing and installing 100mm dia delivery main (From Tube well to Duck Foot bend including cost of C.I/D.F Pipes, D/F Sluice valves, D/F NRV & Specials as C.I Bends, Tail Piece Tees etc.. inside the pump chamber as per standard design complete in all respects |
| 38 | Construction of V- Notch Houdi (Size 1.80 x 0.90 m) including cost of v – notch as per standard design & drawings of Public health Department |
| 39 | CARRIAGE OF MATERIAL |
| 40 | Extra for Carriage of Fine & Course aggregate i.e. Sand & Bajri from query to water works site beyond 5 km (Qty as worked out for the components to be constructed detail 1.9 & rate as per lead on CSR + Ceiling Premium for the applicable lead beyond first 5 km) 40 km. |
| 41 | Sand & BAJRI |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender