Housing Urban and Rular Development Government Departments Closing in 0 days TDR #38691540

Tender For Construction Of A New 2 Pump Fire Station At Dainhat In Purba Bardhaman District Fe222374531s000

Issued by Government Departments · katwa, West Bengal
Tender Value
3.25 Crore
Estimated cost
Bid Submission
14 Aug 2023
0 days left
EMD
6.50 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
katwa → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Construction Of A New 2 Pump Fire Station At Dainhat In Purba Bardhaman District Fe222374531s000

BOQ

Name of Work: Construction of a new 2-Pump Fire Station at Dainhat in Purba Bardhaman District. (FE222374531S000).
Sl. No. Item Description
1Part - A (Structural Part)Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm.
2Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
3Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.)
4Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
5Brick soling with picked jhama bricks including preparation of bed as necessary with brick joints properly filled in and packed with powdered earth and including necessary cushion of similar material below the soling (and in between layers when more than one layer is used) completes as per direction. Single brick flat soling (thickness 75 mm.)
6Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor(A) [Pakur Variety]1:3:6 proportion
7Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and einforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineerin charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade Pakur VarietyGround Floor
81st Floor
92nd Floor
103rd Floor
11Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.For works in foundation, basement and upto roof of ground floor/upto 4 mTor steel/Mild SteelSAIL/TATA/RINLGround Floor
121st Floor
132nd Floor
143rd Floor
15Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof)25 mm to 30 mm shuttering without staging in foundationGround Floor
16Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete workGround Floor
171st Floor
182nd Floor
193rd Floor
20Brick work with 1st class bricks in cement mortar (1:6) In foundation and plinth
21In superstructure, ground floorGround Floor
221st Floor
232nd Floor
243rd Floor
25125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
261st Floor
272nd Floor
283rd Floor
2975 mm. thick brick work with 1st class bricks set in cement, sand mortar (1:4) in ground floor including H.B. netting in every alternate layers.Ground Floor
301st Floor
312nd Floor
323rd Floor
33Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)Do-By fine sand
34Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). [Excluding cost of chipping over concrete surface]With 1:6 cement mortar20 mm thick plaster (Internal plaster)Ground Floor
35Ground Floor (External plaster)
361st Floor
372nd Floor
383rd Floor
39With 1:6 cement mortar15 mm thick plaster (External plaster)Ground Floor
401st Floor
412nd Floor
423rd Floor
43With 1:4 cement mortar10 mm thick plaster (Internal plaster)Ground Floor
441st Floor
452nd Floor
463rd Floor
47Extra for Rusticated plaster (over rate of corresponding item of plaster) With sand plus cement (Cement 0.053 Cu.m/100Sq.m)
48Labour for Chipping of concrete surface before taking up Plastering work.
4918 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]Ground Floor
501st Floor
512nd Floor
523rd Floor
53Extra cost of labour for grinding Kota Stone Floor in treads and riser of Steps
54Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floorArea of each Granite slab upto 0.60 Square meter.
55Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.Ground Floor
561st Floor
572nd Floor
583rd Floor
59WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m Area of each tile upto 0.09 Sq.mColoured decorative
601st Floor
612nd Floor
623rd Floor
63Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge.(White cement, synthetic adhesive and grout material to be supplied by the contra concWith application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.Light colour, Ground Floor
641st Floor
652nd Floor
663rd Floor
67M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
681st Floor
692nd Floor
703rd Floor
71Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.
72Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
73Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.66mm x 90mm
74Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. 32 mm thick
75Supplying fitting & fixing frames for Fire resistant door shutters made of 1st class Malaysian Hardwood (densified to 810 kg/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section120 mm X 70 mm spray quoted...etc
76Supplying & fitting of 55mm thick asbestos free - fire, heat and smoke resistant composite Fire check Door Shutter complying with fire performanceFD120 as per IS:3614 (part -II)-comprising of 2x8 mm Calcium Silicate boards over Chemically treated (with Fire retardant chemicals in pressure impregnation vessels under 160 psi pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141) internal timber (Malaysian Hard Wood, densified to...etc.
77Supplying, fitting and fixing cast iron heavy type spiral staircase of approved design with 50 mm.dia. Stem and C.I. Steps 150 mm as per design 900 mm. high C.I, railing including necessary M.S. tie of suitable section embedded to wall with cement concrete (1:2:4) including cost of intermediate C.I. platform secured with necessary tie to stem and wall with cement concrete (1:2:4) including fixing the stem in ground with cement concrete (1:3:6) complete in all respect with all labour and materials.i) 900 mm dia well
78Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).Sal : MalayasianGround Floor
791st Floor
802nd Floor
813rd Floor
82Supplying solid flush type doors of deluxe decorative (both side) quality, conforming to I:S 2202 timber frame consisting of top and bottom rail and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 27.5mm wide battens places both ways in order to made the door of solid core and internal lipping with teak, mahogony or rose wood approved decorative veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing the shutters in position but excluding the cost of hinges and other fittings in ground floor:35mm thick shutter (single leaf)Ground Floor
831st Floor
842nd Floor
853rd Floor
86Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
87Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
88Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :On timber or plastered surface : With super gloss (hi-gloss) - Two coats (with any shade except white)
89On steel or other metal surface :With super gloss (hi-gloss) - Two coats (with any shade except white)
90Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)40mm X 6mm, 200mm Length
91Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.100mm. X 75mm. X 3.50mm.
92100mm. X 58mm. X 1.90mm.
93Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to i.S. 204/74 fitted and fixed with cadmium plated screws:300mm long x 12mm dia. bolt.
94Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.300mm long.
95Iron door ring of approved quality fitted and fixed with nut and washer75mm dia
96Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.
97Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two Coats
98Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. One Coat
991st Floor
1002nd Floor
1013rd Floor
102Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer.
1031st Floor
1042nd Floor
1053rd Floor
106Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick)
107Godrej Hydraulic door closer fitted and fixed completeMedium type
108Supplying, fitting & fixing UPVC pipes A-Type and fittings conforming to IS:13592- 1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) completeA) UPVC Pipes:110 mm. Dia.
109Plain Tee110 mm. Dia.
110Shoe110 mm. Dia.
111M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof.For built up sections / structural member of specified sections weighing not less than 22.5 kg/ m
112Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples, straining bolt and binding wire where necessary(Payment to be made on the length of individual lines of wire.)
113Supplying galvanised straining bolts (with eye at one end with double nuts and washers) fitted and fixed complete.12 mm. dia. 200 mm.
114Supplying galvanised staples fitted and fixed complete.32.5 mm. to 37.5 mm. size
115Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur variety
11625mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer\"s specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing aspolymer based paint]
117Suppling, fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT (Base Metal Thickness) (0.50mm TCT (Total coated thickness excluding paint), G550 (min 550 yield strength), of Zincalume metallic coating (IS15965) with high Solar Reflectance Index (SRI) value for better colling as per thermatech technology, 1000-1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg.The steel sheet shall be fastened with 40 micron zinc coated or 25 micron zinc-tin alloy coated, hex head, self-drilling screw as per IS 3566-2002 Class 3 fastener. The base steel shall be coated with zinc-aluminium alloy Zincalume (AZ150 )(i.e. 55% Al, 43.4% Zinc, 1.6% Si) minimum of 150 g/m2 coating total on both sides, pre-painted with colorbond XRW (xterior roofing, walling) paint system of 35 micron Super Durable Polyester paint (SDP) with stable inorganic pigment with no lead contents confirming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinity of the material. (i) in Roof a) With 0.5 mm thick sheet
118Supplying and Laying in the specified pattern of interlocking concrete Block Pavement (ICBP) with concrete blocks (with concrete grade as specified as per Table 1 of IS 15658 : 2006) manufactured from BIS license manufacturer with spacer nib (Small pratruding profiles on the vertical face of a paver block used as a device for keeping minimum joint gap in between the paving blocks, as per Cl. No. 3.26 of IS : 15658) and of specified size and shape with aspect ratio (The ratio of length to thickness of a paver block, as per Cl No.3.3 of IS: 15658) as per Table 2 of IS : 15658 with flexural strength/ breaking load as per Annexure G of IS: 15658, on the prepared base course of specified CBR as per Table 1 of IRC SP 63 (2018) or else as mentioned in design and drawing with a cushion of campacted bedding sand of 25-35 mm thick (grading of the bedding sand as per clause 6.5.1 of IRC SP-63) and filling up the gaps in between paver blocks with joint filling sand (the grading of the joint filling sand will be as per clause 6.5.2 of IRC SP 63) and completing the edges with cut blocks as per Cl. No. 8.7 of IRC SP-63(2018) with proper confinement of bedding and joint filling sand, compaction, levelling and filling up of the edge gap60mm thickCloured Decorative
119Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charge....etc.For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr.Ground floor
1201st Floor
1212nd Floor
1223rd Floor
123Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) 4 mm thick
124Iron catch hook of approved quality fitted and fixed to shutter and chowkat6mm dia x 225mm long.
125Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed completeWith continuous plate base (Hexagonal/ Round rod)100 mm grip x 10 mm dia rod.
126Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt , specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /Mineral...etc
127Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes
128Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) 25 mm thick
129Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) With carried earth arranged by the contractor within a radius of 3 km. including cost of carried earth.
130Part- B : (Sanitary & Plumbing )Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer2000 litre capacity
1311000 litre capacity
132Labour for hoisting plastic water storage tank.Upto 1500 litre capacity.Upto 1st story from G.L.
133Extra for each additional story
134Above 1500 litre upto 5000 litre capacity.Upto 1st story from G.L.
135Extra for each additional story
136Labour for punching hole in plastic water storage tank upto 50 mm dia.
137Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. For Exposed WorkCPVC Pipes Class-1, SDR-11,50 mm dia
13850mm dia 3rd floor
13940 mm dia
14032 mm dia
14125 mm dia
14215 mm dia
143Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For 50 usersWith Pakur variety.JSW/JSPL
144Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.With Pakur variety.JSW/JSPL
145Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.(JSW/JSPL)
146Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992A) I) Single socketed 3m length.110 mm dia. (internal)
147Fittings.Plain tee-110mm
148iv) Door Tee(LH) & (RH)-110mm
149vi) Door Y (LH) & (RH)-110mm
150viii) Double Y with Door-110mm
151x) Bend 87.5º-110mm
152xii) Door Bend (LH) & (RH)-110
153xviii) W.C. Connector (450 mm long) W / lipring
154Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete...etc110 mm dia.
155Supplying,fitting and fixing cast iron \"P\" or \"S\" trap conformimg to I.S. 3989 / 1970 and 1729 / 1964 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). 100 mm dia. \"P\" Trap
156S\" Trap
157Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
158Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.630 mm X 450 mm size
159Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.Sink only630 mm X 550 mm size
160Supplying, fitting and fixing Flat back urinal (half stall urinal) in whitevitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.470 mm X 280 mm X 340 mm
161Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).450 mm X 350 mm
162Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding \"P\" or \"S\" trap (excluding cost of concrete for fixing).580 mm X 440 mm
163Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.With \"S\" trap (with vent)Ground Floor
164With \"P\" trap (with vent)
165Supplying, fitting and fixing Half round channel with or without outlet as required set in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).600 mm X 100 mm, White Vitreous Chianaware
166Supplying, fitting and fixing liquid soap container.Cromium plated.
167Supplying, fitting and fixing porcelain soap tray of approved make.Recessed soap tray of size 150 mm X 150 mm
168Supplying, fitting and fixing bathroom shelf of approved make of size 580 mm X 150 mm (porcelain).
169Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only).50 mm dia
17040 mm dia
17125 mm dia
172Supplying, fitting and fixing towel rail with two brackets.C.P. over brass25 mm dia. and 750 mm long
173Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
174Supplying, fitting and fixing shower of approved brand and make.Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system(Equivalent to Code No.542(N) & Model - Tropical / sumthing special of ESSCO or similar brand )
175Chromium plated Hand shower with Flexible Tube & fittings(Equivalent to Code No. Hsh-1937 & ( Equivalent to Code No 5037 & Model - Florentine of Jaquar or similar) )
176Supplying, fitting and fixing bib cock or stop cock.Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar).
177Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar).
178Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar).
179Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etcWith \"P\" trap
180With \"S\" trap
181Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.600 mm long
182Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.1050 mm long
183Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. Polythene Flush Pipe
184Supplying, fitting and fixing C.I. round grating.100 mm
185Labour for boring through any type of soil for sinking tube well of required dia. with top enlargement by rig boring system (either by reserve circulation or by direct rotary method) including hire charges and labour for rig machine, tools and plants, staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes, strainers, blind pipes etc. complete.For depth upto 250 metre for 150 mm dia. Tube well with top enlargement of 250 mm dia.(upto 50 metre).First 50 metre
186Next 50 metre
187Next 20 metre
188Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge150 mm nominal dia6.0 mm wall thickness(2X30M)
189Supplying M.S. male / female adopter of approved make and brand for coupling of M.S. pipe and fibre glass strainers, as per direction of the Engineer - in - Charge.150 mm
190Supplying, fitting and fixing steel cutter piece upto 450 mm long with socket.75 mm dia
191Supplying, fitting & fixing G.I. cap at top. 300 mm
192Supply of PVC pipe and fittings Schedule 80 ( Medium duty) conforming to ASTMD - 1785 and threaded to match with G.I. pipe as per IS - 1239 (part-I) .PVC pipes 150 mm dia (2X120M)
193250 mm dia (2X40M)
194Sypply of E.R.W.M.S.(Electrical Resistant Welded M.S.) black pipe of of TATA make(heavy quality) as per standard specification, 5 mm thick.250 mm dia. (internal)
195Washing and developing tube well with air compressor pump and engine for eight (8) hours pumping per day with necessary arrengement for testing the yield in gallons per hour with \"V\" notch including hire and labour charges for all toos & plants and scaffolding as required .
196Labour for making arrangement for showing verticality test including the cost for hire charges of toos & plants, scaffolding, labour etc. all complete .
197Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire & labour charges for tools & plants and sterilising the equiments, paying all charge and fees, testing etc. complete in all respect as per direction.
198Packing the annular space between the out side of tube well pipes and strainers and the bore with pea size washed gravel of approved quality having size from 2.00mm to 5.00mm or the size approved by the E.I.C. including cost of all materials labour and equiment complete.
199Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.
200Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.For depth upto 150 metre.40 mm dia. boring
201Part- C : (Compound Road & Culvert)Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.Depth of excavation not exceeding 1,500 mm.
202Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
203Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
204Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor(A) [Pakur Variety]
205Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
206Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.TATA/ SAIL/RINL
207Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and einforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineerin charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture] (b) M 25 Grade
208Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(ii) With carried earth arranged by the contractor within a radius of 3 km. including cost of carried earth.
209Part-D (Electrical Installation work )S&F 3 nos. 100 A. porcelain type kit kat fuses & 1 no. porcelain insulator based neutral link on wooden board incl. S&F suitable size of wooden board fixed on wall. (Havells) - N.S.
210Supply and Installation of Cubical panel suitable for 415V, 50 HZ, AC , 3 Phase and neutral system,made from CRCA MS sheet metal (14 SWG) incorporated the following main switches with IP-42/43 protection. The panel should have necessary interconection with incoming and outgoing main switch with busbar by suitable size of conductor and proper earthing attachment.The panel should be powder coated painted and all necessary Shrouds,Cable terminals, Nut-bolts and required accessories. (Panel should CPRI approved)Incoming : 125 A. 415V TPN On-LoadFront operated (open execution type main switch)--- 1 no. (Make-L&T)Outgoing : 100 A, 415V TPN On-LoadFront operated (open execution type main switch)--- 2 nos. (Make-L&T)63A, 415V TPN On-LoadFront operated (open execution type main switch)--- 2 no. (Make-L&T)32A, 415V TPN On-LoadFront operated (open execution type main switch)--- 4 nos. (Make-L&T)Digital Multifunction Meter with selector switch --- 1 no.R,Y,B indicating lamp --- 3 nos.30/5 A. CT coils --- 3 nos.Danger Board --- 2 no.Make: L&T,ABB,C&S,HPL(NS)Interconnection - i. From Input Main switch to Busbars - 4 x 20mm x 5mm Copper bars covered by coloured PVC Heat shrink.ii. From Busbars to 100 A. output Main switch - 4 x 15mm x 3mm Copper bars covered by coloured PVC Heat shrink.iii. From Busbars to 63 A. output Main switch - 25 sq.mm. Copper wires (1.1 KV voltage grade single core stranded \"FR\" PVC insulated & unsheathed copper wire).iv. From Busbars to 32 A. output Main switch - 10 sq.mm. Copper wires (1.1 KV voltage grade single core stranded \"FR\" PVC insulated & unsheathed copper wire). N.S.
211S&F 415V. TPN SFU with sheet steel enclosure on angle iron frame on wall incl. S & F 3 nos. DIN type HRC fuse & necy. connection as per GS. - (L&T/ Siemens) - D -3/ 4.a. 100 A.
212S&F 415V. TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall incl. necy. Connection as per GS. (L&T/ Siemens) - D - 2/ 3.a.125 A.
213Supplying and fixing double door VTPN MCB DB with IP-42/43 protection, concealed in wall incl. necy. connection as per GS.8 way- 1 no. 415 V. 100 A. FP MCCB & 4 nos. 415 V. 40 A. TP MCBs, 3 nos. 415 V. 32 A. TP MCBs & 3 nos. 6-32 A. SP MCBs as required (Legrand/ Siemens/ Cabtree/ L&T) - D-11/15 & D-6/ 7. & D-8/ 10.
214Supplying and fixing double door VTPN MCB DB with IP-42/43 protection, concealed in wall incl. necy. connection as per GS.4 way- 1 no. 415 V. 63 A. FP MCCB & 3 nos. 415 V. 32 A. TP MCBs & 3 nos. 6-32 A. SP MCBs as required (Legrand/ Siemens/ Cabtree/ L&T) - D-11/15 & D-6/ 7. & D-8/ 10.
215Supplying and fixing double door Horizontal TPN MCB DB with IP-42/43 protection, concealed in wall incl. necy. connection as per GS.4 way- 1 no. 415 V 32 A. FP MCB & 12 nos. 240 V 6-32 A. SP MCBs as required (Legrand/ Siemens/ Cabtree/ L&T) - D-10/14 & D-6/ 7.
216S&F double-door SPN MCB DB with IP-42/43 protection, concealed in wall incl. necy. connection as per GS.2+12 way Enclosure - 1 no. 240 V, 32 A DPMCB & 10 nos. 240 V, 6-32 A SPMCBs as required (Legrand/ Cabtree/ L&T) - D-9/13 & D-6/ 7.
217Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Finolex/ Polycab/ KEI) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish - E-20/ 1.Average run 8 mtr
218Do-do-do- on Board 6 A. Modular type socket & switch as per GS. - E-20/ 3.
219S&F PVC Rigid Conduit \"FR\" [Precision Make] on wall, ceiling with saddles and other accessories as required as per GS. - E-16/ 7.20 mm dia
22025 mm dia
221S&F 19 mm dia polythene pipe with 3 mm thick complete with fittings as necy. under ceiling/beam, bound with S&F 22 SWG GI binding wire as per GS. (synchronizing with roof/beam casting work of building construction) - E-2/1.
222Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F 19 mm dia 3 mm thick heavy gauge polythene pipe as per GS. incl. mending good damages to building works. - E-3/6.
223Supplying and Laying 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire ((Finolex/ Polycab/ KEI)) of the following sizes in the prelaid Polythene pipe and making necy. connection as required - E-9/1.2 x2.5 sqmm + 1 x1.5 sqmm as ECC (For P.P. & computer Board point & for main line of Low bay lights)
2243 x 1.5 sqmm (for Separate 6 A. & others)
2252 x 1.5 sqmm (for Call bell points)
2262 x 4 sqmm + 1 x 2.5 sqmm as ECC (for A.C.)
2272 x 10 sqmm + 1 x 4 sqmm as ECC (from TPN DB to SPNBDB) - N.S.
2284 x 10 sqmm + 2 x 4 sqmm as ECC (from VTPN DB/ Panel to TPN DB) - N.S.
2294 x 10 sqmm. (from VTPN DB to Timer)
2304 x 35 sq.mm. (from Meter to Normal Panel via Cut outs) - N.S.
231Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with switch - 2 set, on S&F 6 Module GI Modular type switch board flushed in wall with top cover plate incl. making necy. connections as per GS. (Legrand/ Cabtree)
232Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with switch - 1 set on S&F 3 Module GI Modular type switch board flushed in wall with top cover plate incl. making necy. connections as per GS. (Legrand/ Cabtree)
233Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket with switch - 3 set with 240 V, 16 A, 3 pin Modular type plug socket with switch - 1 set, with Modular type Indicator & 1 no. Modular type 16 A. SP MCB and 4 nos. blank plates without plug top on S&F 18 Module GI Modular type switch board flushed in wall with top cover plate incl. making necy. connections as per GS. (Legrand/ Cabtree)
234Supply & Fixing 240 V, 25/ 20 A, 3 pin Modular type plug socket on S&F 2 Module GI Modular type switch board flushed in wall with top cover plate incl. making necy. connections as per GS. (Legrand/ Cabtree) - E-17/ 5.a.
235S&F 240 V, 20/ 25 A, Modular type starter with 10/ 16 A. Modular switch type SP MCB (C Curve) and 4 Module GI Modular type switch board and 1 no. Blank Plate flushed in wall with top cover plate incl. necessary connection as per GS. (Legrand/ Cabtree) - E-19/ 17.
236Supply & Fixing 240 V, 16 A, 3 pin Modular typeswitch - 1 no. & 1 no. blank plate on S&F 2 Module GI Modular type switch board flushed in wall with top cover plate incl. making necy. connections as per GS. (Legrand/ Cabtree)
237Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall as per GS. - E-4/11.240 mm x 200 mm x 65 mm
238200 mm x 150 mm x 65 mm
239100 mm x 100 mm x 65 mm
240150 mm x 100 mm x 65 mm
241300 mm x 200 mm x 65 mm
242Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws - E-5/13.240 mm x 200 mm x 65 mm
243200 mm x 150 mm x 65 mm
244100 mm x 100 mm x 65 mm
245150 mm x 100 mm x 65 mm
246300 mm x 200 mm x 65 mm
247Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. - F-5/9.4 sq. mm.
2482.5 sq.mm.
24910 sq.mm.
25035 sq.mm.
251Supplying of 4\" long twin LED Tube light fitting, complete with all accessories & 2 nos. 230V. 20 W. T-LED Tubes of PC body. (Philips - TMC 501 2xT-LED 20 W with two nos. LED tubes - MAS LED tube 1200 mm 18W865 T8, CG - IGP162LT8-16 & 2 nos. LT8-20-865-(2)) - N.S. with 3years warranty
252Supplying of 4\" long single LED Tube light fitting, complete with all accessories & 1 no. 230V. 20 W. T-LED Tubes of PC body. (Philips - TMC 501 1xT-LED 20W with one no. LED tube - MAS LED tube 1200 mm 18W865 T8, CG - IGP161LT8-16 & 1 no. LT8-20-865-(2)) - N.S. with 3years warranty
253Fixing only single/ twin Tube light with fitting complete with all accessories directly on wall and suitable size of MS fastener as per G.S. - C-2/ 14.d.
254Fixing only Single/twin Tube light with fitting complete with all accessories suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp as per G.S. - C-2 /17.
255S&F of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet incl. S&F 12mm dia 600mm long MS rod duly bent as per GS. - D-14/31.
256Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) on existing Modular GI switch board with top cover plate incl. making necy. connections etc as per G.S. (Legrand/ Cabtree) - E-18/ 10.
257Supplying of ceiling fan of following size with complete accessories like blades, canopy, fork, rubber bush etc. (Orient (PSPO) /Usha stricker/ Crompton Aura) - N.S.48\"
25856\"
259Fixing only ceiling fan incl. necy. connection as per G.S. - C-3/ 21.
260Supplying of following Heavy duty exhaust fan with blades & others accessories. (E.P.C. / Crompton make) - N.S.9\" Heavy duty exhaust fan.
26112\" Heavy duty exhaust fan.
262Fixing only of following exhaust fan after making hole in wall as per G.S. incl. necy. connection as per G.S. - C-4/ 28.9\"
26312\"
264Supply & Fixing GI sheet (20 SWG) metal Cowl for following exhaust fan with MS flat iron frame & GI wire mesh on wall as per GS. - D-14/ 33.9\"
26512\"
266S&F 230 V. 9 W pin type LED bulb (Philips, CG Make) on holder. - N.S.
267Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on 3 mm thick bakelite board on wall incl. S&F bakelite board. - D-13/ 20.a.
268S&F LED Mirror light fittings on wall incl. necy connection as per GS. (Philips - 31165/CG - LCL-07-CDL) - N.S.with 3years warranty
269S&F outdoor type LED bulkhead light fittings on wall incl. necy. Connection as per GS. (Make:-Philips - WT202W LED6S NW PSU S2 PC/ CG - LBHP-10-CDL) - N.S.with 3years warranty
270S&F LED Step Lamp in wall incl. necy connection as per GS. (Philips - BWG150 LED50/NW PSU 220-240V IP67 7043/ CG - LSL-6-CDL) - N.S.with 3years warranty
271S&F of 230V. 40 W LED Lowbay Luminaries with all accessories on structure/ surface including necessary connection as per GS & hanging arrangement as per direction of EIC. (Make Crompton - CIP-311-40-57-HL4-CP-NSG/ Philips). - N.S. with 3years warranty
272Excavation of soil for installation of Earth Electrode and filling & ramming. - Soft soil. - G-1/1.
273Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long as per GS. - G-1/2.a.By TATA-Medium GI pipe
274Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar as per GS. - G-2/4.a.
275Connecting the equipments to earth busbar incl. S & F 10 SWG GI (Hot Dip) wire on wall/floor as per GS. - G-2/5. iv.10 SWG
2764 SWG
277S&Delivery of the following sizes 1.1 kv grade XLPE/PVC cable (Make: Havells/ Gloster/ Polycab/ Finolex) - N.S.2 core x 10 sqmm. Al. armoured cable
2784 core x 35 sqmm. Al. armoured cable
2794 core x 16 sqmm.Al. armoured cable
2804 core x 70 sqmm.Al. armoured cable
2813 core x 2.5 sqmm.Copper. Unarmoured cable
282Laying of following cables on wall/surface incl. S & F MS saddles with earthing attachment,as per GS. - F-1/2.2 core x 10 sqmm. Al. armoured cable with 1 no. 10 SWG GI wire
2834 core x 35 sqmm. Al. armoured cable with 2 nos. 10 SWG GI wires
2844 core x 16 sqmm.Al. armoured cable with 2 nos. 10 SWG GI wires
2854 core x 70 sqmm.Al. armoured cable with 2 nos. 10 SWG GI wires
2863 core x 2.5 sqmm.Copper. Unarmoured cable
287Supplying and fixing compression type gland complete of following XLPE/PVC armoured cables as below. F-4/7.2 core x 10 sqmm. Al. armoured cable
2884 core x 35 sqmm. Al. armoured cable
2894 core x 16 sqmm.Al. armoured cable
2904 core x 70 sqmm.Al. armoured cable
291Finishing the end of following XLPE/PVC armoured cables as per GS incl. supplying and fixing solderless socket (Dowels make) etc. F-5/8.b.2 core x 10 sqmm. Al. armoured cable
2924 core x 35 sqmm. Al. armoured cable
2934 core x 16 sqmm.Al. armoured cable
2944 core x 70 sqmm.Al. armoured cable
295Supplying & fixing 40 mm dia medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required - F-6/11.
296S&F timer box consisting with 1 no. 230 V. 32 A. FP MCB, 1 no. 32 A. 4 pole Power contactor, 1 no. toggle switch, 1 no. timer clock, Inditating lamps etc. incl. suitable size of interconnecting wire (power line by 10 sq.mm. wire, control circuit by 1.5 sq.mm., indicating circuit by 1.5 sq.mm.) as reqd. as per GS. - N.S.
297S&F 80 mm dia x 1.5 mts. long GI Pipe (ISI-Medium)pole inl S&F of 1 no G.I sole plate incl. necy. holes as required and providing cement concrete (6:3:1) muffing around the pole of dimension 600X600X600 mm on the roof of the building after chipping the roof incl. 3mm thick net cement finish and providing G.I. earth bolt after making drilled hole etc on pole incl. painting as per G.S. - N.S.
298S / F single arm header fabricated with 100 mm dia G.I. pipe (pole cap) of 10\" height welded with 1.5 m long 40 mm dia. G.I. pipe at an suitable angle incl. S / F nuts, bolts washer etc incl. painting as per G.S. - N.S.
299S&D 230 V. 90 W. LED Street light fittings (Philips - BRP410 LED 091 CW HE MR PC S2 PSU GR/ CG - CRP-411-90-57-SL-GL-NSG) - N.S.with 3years warranty
300S&D 230 V. 72 W. LED Street light fittings (Philips - BRP 409 LED 074 CW HE MR FG S1 PSU GR/ CG - CRP-409-70-57-GL-NSG)with 3years warranty
301Fixing only LED street light fittings on pole incl. necy. Connection as reqd. as per GS. - N.S.
302Supplying & Fixing 200x150x100 mm GI waterproof type looping cable box on pole having 4 mm thick comprising of one 250 V 16 A kit-kat fuse unit, one NL on porcelain insulator as per GS. incl. necy. Connection & painting with anticorrosive paint as per GS - H-5/5.
303S&laying 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core 3 x 1.5 sq.mm. copper wire as Loop wire. (from loop box to fittings) - E-9/1.
304S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) - J-1/ 1.
305Supply & fixing GI (Hot Dip) strips 40 mm x 6 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good as per GS. - N.S.
306Supply & fixing of GI (Hot Dip) strips 40 mm x 6 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work - N.S.
307Making soldered joints between conductors, conductors and air terminals for strips as per GS. J-1/ 5.
308Making soldered joints between conductors and down pipes/ other metallic objects for strips as per GS. J-1/ 6.
309Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation. J-1/ 7.
310Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: J-1/4.Length above 0.5 Mtr
311Supply & Fixing of Testing Joints by 40 mm x 6 mm thick GI (Hot Dip) strip 125 mm long grouted in wall having clearance of 6 mm from wall for making connection as per GS - J-2/ 13.
312Connecting the Earth pit to Testing Joint including S & F 40 mm x 6 mm galvanised (Hot Dip) MS flat in wall/floor incl. drilling holes as per GS. - N.S.
313S&F 230 V. 40 W. LED post top type Gate light on S & F 40 mm dia 2\" length GI Pipe grouted in pillar (CG- LPTC-40-CDL/Philips/ Wipro) after cutting the pillar and mending goods damages incl. Necessary connection with S& F suitable size Net Guard on Gate light.- N.S. With 3 years warranty
314Supply & installation of angle frame mounting rectangular shape Glow sign board size of ( 12\"x4\"x6\") fabricated with 25 x 25 x 6 mm M.S. angle and 25 x 6 mm M.S. flat. Front side of the board making arrangement for hinged type door with locking arrangement made with M.S. angle incl. provision for fixing the Poly carbonate sheet facial approved colour(2 mm thick) with computerised lettering in blue base white lettering rigidly fixed on angle iron frame. The sign board should be glow by 10 nos. 20 W. LED Tube light ( Make- Philips/CG/Havells) and incl. necy. arrangements & connections. Back side of the board should be covered with 14 SWG GI sheet to protect rain water. The sign board should be fixed on roof by 4 nos. 40x40x6 mm angle bar which will be fixed on wall by fust nuts, necessary nuts bolts etc. & painting as per direction of E.I.C. The cost of transportation and scaffolding charges are included with the rate. The sign board must be inscripted as per the authority with bishwa bangla logo as per direction of EIC.. - N.S.
315Add GST @ 18%
316Add Labour Welfare Cess @ 1%

AI Tender Summary

OUR REF NO 38691540
AUTHORITY Government Departments
TENDER VALUE 3.25 Crore
LAST DATE 14-08-2023
Authority
Authority Name Public Works Department
Work Description Tender For Construction Of A New 2 Pump Fire Station At Dainhat In Purba Bardhaman District Fe222374531s000
Basic Detail
Tender No WBPWD/SE/WC-I/ENIT-08/2023-24
Bidding Type Tender
Location
City katwa
State West Bengal
Key Dates
Publish Date 18 Jul 2023
Submission Date 14 Aug 2023
Open Date 16 Aug 2023
Finance
Tender Value 3.25 Crore
Tender Fee Ref. Documents
EMD 6.50 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
5fca7dff-7554-47ba-b93a-28c3c3e3d224.html
2911.pdf
BOQ_1139951.xls
Special_Conditions_of_Con.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 18, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 14, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 16, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

5fca7dff-7554-47ba-b93a-28c3c3e3d224.html

pdf

2911.pdf

xls

BOQ_1139951.xls

pdf

Special_Conditions_of_Con.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders