| 1 | DRAINAGE |
| 2 | Soil Testing and Design |
| 3 | Submission of design, drawing to construct as per tenderer\"s own seismic proof design and drawings (approved by the department) complete and supply of all material, labour, T&P etc. to constructSump Well (storage capacity of 1100 KL), Screening Chamber, R.C.C. Drains & Trunk Mainas per tenderer\"s own seismic proof design with R.C.C. raft & wall. The design shall be based on safe bearing capacity of soil at site i.e. 8.0 Tonne/M2 . BC is tentative, contractor will have to test the B.C. and design of Sump Well will be on actual B.C. found. |
| 4 | Sump Well with Pump House |
| 5 | Excavation in foundation & plinth in ordinary soil (sand, loam or clay) or kankar mixed soil with lift up to 1.50M and lead up to 50M including refilling watering ramming of excavated earth into the trenches, or into the space between the building and sides of foundation trenches or into the plinth and disposal of surplus earth upto a distance of 50m from the center of foundation trenches. |
| 6 | 0.00 M to 1.50 M below G.L. |
| 7 | Laying of concrete with 40mm gauge Stone ballast, Coarse sandand cement in ratio of 8:4:1 in foundation including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 8 | R.C.C. work in Raft with cement, approved coarse sand and 20mm gauge stone grit in proportion of 1:1.5:3 excluding supply of reinforcement and its bending but including 0.50mm gauge wire and fixing in position also centering, shuttering, all materials, labour, T&P etc. required for proper completion of work. |
| 9 | R.C.C. work in sump well walls with cement, approved coarse sand and 20mm gauge stone grit in proportion of 1:1½:3 in the following works excluding supply of reinforcement and its bending but including 0.50mm gauge wire and fixing in position also centering, shuttering, all materials, labour, T&P etc. required for proper completion of work. |
| 10 | R.C.C. work in following structure members with cement, approved coarse sand and 20mm gauge stone grit for M-30 Grade excluding supply of reinforcement and its bending but including 0.50mm gauge wire and fixing in position also centering, shuttering, all materials, labour, T&P etc. required for proper completion of work. |
| 11 | In Column |
| 12 | In Heavier Beam |
| 13 | In Slab |
| 14 | TOR steel iron work in R.C.C. work wrought to required shape as necessary including its bending and wastage including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 15 | 25mm thick 1:2:4 plain cement concrete floor with cement, coarse sand and 2 cm gauge approved stone grit, laid in panels, finished with 3mm thick floating coat of neat cement over 7.5cm thick base concrete consisting of cement and fine sand and first class brick ballast 4 cm gauge in proportion of 1:4:8 and removing any over lapping mortar in the joints of the panels if any and giving team an uniform finish including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 16 | 1st class brick work for 1 brick thick walls in 1:4 cement & Coarse mortar in superstructure including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 17 | Supply and fix of all materials, labour, T&P etc. required for making door shutters by M.S. sheet 18 gauge, M.S. angle 45x45x6mm size also including angle iron chaukhat with hold fast as instructed by Engineer Incharge including cement, concrete for fixing the same in the walls complete. |
| 18 | 12mm thick plaster in cement & Coarse sand mortar in ratio of 1:4 over brick work minimum thickness not to be less than 10mm including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 19 | 12 mm thick cement plaster to ceiling of mix 1:4 cement, coarse sand mortar including supply of all materials, labour, T&P etc. required for completion of work. |
| 20 | Apex paint (approved quality) in two coats of approved shade over one primary coat of white putty including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 21 | Painting or varnishing of new iron work with one coat of primer and two coat of approved paint and varnish including supply of all materials, labour, T&P etc. complete in all respect in all floors. |
| 22 | Supply and fixing of 32 mm thick S.S. 304 Grade pipe railing 16 gauge on drain wall and walk ways including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 23 | Sinking of Well (12.00 m Dia) |
| 24 | 1.50 to 3.00 m deep in Ordinary Soil |
| 25 | 3.00 to 6.00 m deep in Ordinary Soil |
| 26 | 6.00 to 9.00 m deep in Ordinary Soil |
| 27 | 9.00 to 12.00 m deep in Ordinary Soil |
| 28 | Supply and laying complete 4 cm thick insulation layer of sand and clay over reinforecement concrete roof and supply and fixing of birck tiles over insulation layer. |
| 29 | Bailing out/pumping out of water including of all labour material T&P etc.complete |
| 30 | Supply, Carting, Laying & Jointing of 900 mm dia R.C.C. N.P. 4 hume pipe |
| 31 | Screen Chamber |
| 32 | Excavation in foundation & plinth in ordinary soil (sand, loam or clay) or kankar mixed soil with lift up to 1.50M and lead up to 50M including refilling watering ramming of excavated earth into the trenches, or into the space between the building and sides of foundation trenches or into the plinth and disposal of surplus earth upto a distance of 50m from the center of foundation trenches. |
| 33 | 0.00 M to 1.50 M below G.L. |
| 34 | 1.50 M to 3.00 M below G.L. |
| 35 | 3.00 M to 4.50 M below G.L. |
| 36 | Laying of concrete with 40mm gauge Stone ballast, fine sand (1.25 FM) and cement in ratio of 8:4:1 in foundation including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 37 | R.C.C. work in Raft with cement, approved coarse sand and 20mm gauge stone grit in proportion of 1:1.5:3 excluding supply of reinforcement and its bending but including 0.50mm gauge wire and fixing in position also centering, shuttering, all materials, labour, T&P etc. required for proper completion of work. |
| 38 | R.C.C. work in chamber walls with cement, approved coarse sand and 20mm gauge stone grit in proportion of 1:1½:3 in the following works excluding supply of reinforcement and its bending but including 0.50mm gauge wire and fixing in position also centering, shuttering, all materials, labour, T&P etc. required for proper completion of work. |
| 39 | TOR steel iron work in R.C.C. work wrought to required shape as necessary including its bending and wastage including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 40 | Making screen with 25 mm x 10 mm Stainless Steel (304 Grade) flatwith channel. |
| 41 | Supply, Carting and Fixing of C.I. Sluice Gate at opening of drain as per design and U.P. Jal Nigam Specification or direction of Engineer In-charage including supply of all material, labour, T&P etc. |
| 42 | Boundry Wall,Drain and Campus Development |
| 43 | Excavation in foundation & plinth in ordinary soil (sand, loam or clay) with lift up to 1.50M and lead up to 50M including refilling watering ramming of excavated earth into the trenches, or into the space between the building and sides of foundation trenches or into the plinth and disposal of surplus earth upto a distance of 50m from the center of foundation trenches. |
| 44 | Laying & concrete with 40mm gauge Stone ballast, fine sand (1.25 FM) and cement in ratio of 8:4:1 in foundation including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 45 | R.C.C. work in Raft and plinth beam with cement, approved coarse sand and 20mm gauge stone grit in proportion of 1:1.5:3 excluding supply of reinforcement and its bending but including 0.50mm gauge wire and fixing in position also centering, shuttering, all materials, labour, T&P etc. required for proper completion of work. |
| 46 | 1st Class brick work in cement & Coarse sand mortar in ratio 1:4 in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 47 | Sand filling in plinth including supply of necessary quantity of sand including loading, unloading and cartage of sand, filling, watering, ramming, dressing & leveling, labour, T&P etc. complete as per direction ofEngineer Incharge. |
| 48 | 1st Class brick work for 1 brick thick walls in 1:4 cement & Coarse sand mortar in superstructure including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 49 | Mild steel or iron work in heavy sizes wrought to required form including drilling holes,rivetted or welding here necessary and also nuts bolts etc.and their fixing required for prper completion of work. |
| 50 | Mild steel or iron work in R.C.C. work wrought to required shape as necessary including its bending and wastage including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 51 | Earth filling in water works compound including supply of necessary quantity of earth from the site of work including loading, unloading and cartage of earth, filling, watering, ramming, dressing & leveling, labour, T&P etc. complete as per direction of Incharge. |
| 52 | Mild steel work of small sizes and section ,supply & fixing of all materials, labour, T&P etc. required for making door shutters by M.S. sheet 18 gauge, M.S. angle 45x45x6mm size also including angle iron chaukhat with hold fast as instructed by Engineer Incharge including cement, concrete for fixing the same in the walls complete. |
| 53 | 12mm thick plaster in cement & Coarse sand mortar in ratio of 1:4 over brick work minimum thickness not to be less than 10mm including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 54 | Provide,laying and jointing of 80mm thick C.C. interlocking tiles on 10 cm thick base concrete of 1:4:8 (Cement: Sand: 20 mm Stone ballast including supply of all materials, labour, T&P etc. required for proper completion of work. |
| 55 | Apex paint (approved quality) in two coats of approved shade over one primary coat of putty including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 56 | Painting or varnishing of new iron work with one coat of primer and two coat of approved paint and varnish including supply of all materials, labour, T&P etc. complete in all respect in all floors. |
| 57 | Trunk Main |
| 58 | Supply of 600 mm dia DI K-7 pipe confirming to latest IS complete in all respect including railway freight, insurance charges & special fittings F.O.R etc. complete. |
| 59 | Excavation of earth for pipeline in all types of soil, including lift upto 1.50 m and lead upto 50 m from center of trench, giving one meter cover from top of pipe, refilling of earth after laying pipe line in 20 cm layer with watering, ramming including all labour, T&P etc. complete. |
| 60 | Carting, laying of 600 mm dia DI K-7 pipe into the trenches as per required true alignment & gradient including jointing, testing of pipeline & all jointing materials such as nut bolts, rubber insertion, white lead etc. labour, T&Petc complete. |
| 61 | RCC for thrust block in 1:2.4 cement, coarse sand & stone grit 12~20mm dia. For proper completion of work. |
| 62 | TOR steel or Iron work in plain work such as RCC work complete. |
| 63 | Connection for Pumping Station to Trunk mains including cost of specials complete for 600 mm Dia. K-7 |
| 64 | Drains |
| 65 | Dismantling of cement concrete road or cement structures and making the same on the alignment of proposed drains in all respect as directed by Engineer Incharge. |
| 66 | Dismantling of Interlocking Tile road and reinstatement of the same including supply & fixing of I-shaped Rubber Moulded interlocking tile complete in all respect. |
| 67 | Earthwork in excavation by mechanical means ( Hydraulic excavator ) / manual means over areas (exceeding 30cm in depth 1.5m in width ) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed for all kind of soil. |
| 68 | 0.0~1.5 m |
| 69 | 1.5~3.0 m |
| 70 | 3.0~4.5 m |
| 71 | Concrete with 4cm gauge stone ballast, coarse sand of 1.25 FM and cement in proportion of 8:4:1 in foundation and under floors including supply of all materials , labour, T&P etc. complete required for proper completion of work. |
| 72 | RCC work in drain with cement, coarse sand and approved stone grit in the proportion 1:1.5:3,following works excluding supply of reinforcement and its bending but including 0.50mm gauge wire and fixing in position also centering, shuttering, all materials, labour, T&P etc. required for proper completion of work. |
| 73 | RCC work in Footing in 1:1.5:3 |
| 74 | RCC work in Wall in 1:1.5:3 |
| 75 | RCC work in Slab in 1:1.5:3 |
| 76 | Centering & Shuttering including strutting, propping etc. and removal of form for : |
| 77 | Foundations, footing etc. for mass concrete. |
| 78 | Columns, Piers, Abutments, Posts & Struts |
| 79 | Mild steel or Iron work in RCC wrought to required shape as necessary including bending for proper completion of work and authorized overlapping shall be measured. |
| 80 | Provision of Manhole chamber 900x800x1000 mm |
| 81 | Provision for laying of RCC Hume Pipe : |
| 82 | 600mm dia. |
| 83 | Provision for laying of Trenchless pipe for crossing of canal : |
| 84 | 600mm dia. |
| 85 | Cost of Weep Holes |
| 86 | Bailing out of water during construction at site during the execution of the entire work till its completion including of the pump, fuel, labour T&P etc. |
| 87 | Crossing Culverts : |
| 88 | RCC work with cement, coarse sand and 40mm stone ballast approved stone grit in the proportion 1:1.5:3 |
| 89 | RCC work in Wall in 1:1.5:3 |
| 90 | RCC work in Slab in 1:1.5:3 |
| 91 | Mild steel or Iron work in RCC wrought to required shape as necessary including bending for proper completion of work and authorized overlapping shall be measured. |
| 92 | Miscellaneous Items : |
| 93 | Shifting of RCC or MS Pole |
| 94 | Two pole jointing each other |
| 95 | Single pole |
| 96 | Providing & erecting 2.0 m high temporary barricading at site. |
| 97 | Mild Steel Work In Bar Screen Racks |
| 98 | Provision of Electricity |
| 99 | ELECTRICAL & MECHANICAL |
| 100 | SUBMERSIBLE PUMP SET: |
| 101 | Non clog sewagesubmersible pump coupled with submersible motor for 400±10% V AC, 3phase 50 Hz. suitable to pump storm water with specific gravity of 1.05 and also capable to handle solids up to 100mm size having following material of construction.Casing- CI FG 260: IS 210 , 1.5 TO 2% NickelImpeller-CF8M- SS 316Shaft & Shaft sleeve- ASTM SS 410 RPM : 960130 LPS, 12 m Head, 40 HP |
| 102 | GUIDE RAIL SYSTEM(Automatic Coupling system)(i) Guide rail system comprises of Pedestal, bracket, upper guide rail holder etc. - 5 Set(ii) Guide pipe/Rail for above 5 sets pumps @ 6 Meter/ pump. - 30 Mt |
| 103 | CAPACITOR:Provision for supply of shunt type power factor improvement capacitor of suitable KVAR to boost the power factor up to 0.95. |
| 104 | L.T. Pannel with starterA - 40 HP Soft Starter-5 Nos (4 W+1S) B -Supply of 1 no. panelextensible typeswitchboard suitable for 0.415 KV3 phase 50 HZ. A.C. supply in cubical pattern, floor mountingcompletewith insulatedbus bars of suitable size , 2nos bus coupler forrequiredload. The switch board shall consist of the following :(a) 03no.Incoming Panelcomprisingofsuitable capacity ACB/MCCB indoor vertical isolation horizontally drawouttype withrelays as per ISS.Panelwill be comprisingof voltmeterwith selector switch, power factor meter,frequencymeter. KWH meter and ammetercomplete with selector switch, motor protection relay etc to operate 05 nos. of above required motor. (b) 09 Nos. outgoing panelsfor pumping plants. 05 Nos. Of Pump, 01 No. for light & fixature, 03 nos spare Each panelhavingsuitable capacity MCCB with ammeter and C.T.with selectorswitch,KWmeter, single phasingpreventer, capacitoretc to operate 5 nos. of above required motor. |
| 105 | MAIN PIPING & VALVES: |
| 106 | Piping-Supply of Main Piping complete with common header outside the pump house alongwith all neessary nuts, bolts, rubber packing etc., as per following details - (i) 600x300x600 mm dia DI A/F Tee - 5 Nos(ii) 600x300x600 mm dia DI A/F Tee - 1 No(iii) 600 mm dia Blind Flange- 1 No(iv) 600 mm dia DI D/F Pipe x 0.5 mtr long - 1 No(v) 600 mm dia DI D/F Pipe x 3 mtr long - 1 No(vi) 600 mm dia DI D/F Pipe x 2 mtr long- 1 No(vii) 600 mm dia DI D/F Pipe x 1 mtr long- 1 No(viii) 600 mm dia DI D/F Pipe x 1.5 mtr long - 5 Nos(ix) 300 mm dia DI D/F Pipe x 0.5 mtr long - 5 Nos(x) 300 mm dia DI D/F Pipe x 1 mtr long - 5 Nos(xi) 300 mm dia DI D/F Pipe x 2 mtr long - 5 Nos(xii) 300 mm dia DI D/F Pipe x 3 mtr long - 5 Nos(xiii) 600 mmx400mm size reducer - 5 Nos(xiv) 300 mm 90 degree bend- 1 No(xv) 600 mm 90 degree bend- 1 No(xvi) SS Nut Bolts -(xvii) Rubber Packing, insertions and other required material |
| 107 | Provision for main piping and valves for 300 mm delivery and 600 mm dia common header line |
| 108 | Valves - Valves confirming to relevant IS codes: |
| 109 | Sluice Valve |
| 110 | DI 300 mm ø |
| 111 | DI 600 mm ø |
| 112 | Reflex Valve |
| 113 | DI300 mm ø |
| 114 | DI600 mm ø |
| 115 | Dismantling joint |
| 116 | DIDF300 mm ø |
| 117 | DIDF600 mm ø |
| 118 | Direct on line electromagnetic type flow meter cum totalizer of 600 mm dia in common header for measuring dischargeofpumpswithsignal transmitter device. Digitalflowindicatorshallbe installedin pump house on instrument control panel. |
| 119 | Size 600 mm (Common header) |
| 120 | LIFTING TACKLE: |
| 121 | Supply,erecting,testing & commissioning of 5 ton capacityH.O.Tcomplete in all respect with travelling trolly and girder etc. complete |
| 122 | Tools & Plants: |
| 123 | Supply of Tools(i) HT Megger- 1 no.(ii) LT Megger- 1 no.(iii) Hydraulic crimping tool- 1 no.(iv) Manual crimping tool- 1 no.(v) Clamp multimeter- 1 no.(vi) Chain wrench(vii) Pipe wrench(viii) Screw wrench(ix) Ring spanners(x) Double ended spanners(xi) Insulated pliers(xii) Hammer with handle(xiii) Measuring tape of different size(xiv) Sprit level set |
| 124 | Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher. |
| 125 | 12/20 mm. thick rubber electric resistance rubber sheet as per ISS. |
| 126 | Installation & Commissioning:Installation & Commissioning of all 5 Nos. pump sets, piping & valves, guide rail, lifting tackle etc. complete. |
| 127 | Testing Provision for testing of each pump set, valves etc. at manufacturer works and at site. |
| 128 | PaintingProvision for painting of all pumps, piping and valves with two coat enamel paint |
| 129 | Light Wiring :- Light wiring of Pump House, L.T. control room, Meter room, D.G. room, Store and Staff Quarters: |
| 130 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq.mm FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) of approved make in surface / recessed ISI marked medium duty PVC conduit & it\"s accessories, round tiles,18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point. 6 A switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. |
| 131 | Wiring point for HPMV/sodium vapor lamp/ power plug with 2.5 sq mm PVC insulated multi core cable in heavy gauge rigid PVC conduit concealed in wall complete with 1/18 copper wire. Earth continuity wire with 16 Amp. metal clad SPN switch/ 15 Amp. piano type switches complete in all respect. |
| 132 | Provision for supply & fixing of main suitable distribution boards with MCBs for controlling the lighting system. |
| 133 | Supply and fixing of factory wired industrial fluorescent tube fitting with reflector fabricated from CRCA sheet and finished with powder coating / vitreous enamelled complete with accessories complete including tube etc. on wall. |
| 134 | Supply and fixing of HPSV/MV 125 watt fixture with lamp and its all accessories. |
| 135 | Supply & fitting of steel swaged tubular poles of9M length as per I.E. rules. |
| 136 | Supply and laying of 50 sq mm Al conductor XLPE insulated 3 core armored submersible cable from Composite panel to pumps |
| 137 | Aluminium Junction Box |
| 138 | Exhaust fans of suitable sweep/capacity |
| 139 | 1 - Diesel Generating sets. - 250 KVA Supply of DG Set complete with 1500 RPM Diesel Engine of suitable BHP & AC Brush less SPDP Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage). Engine shall have residential silencer, up to 10 M exhaust piping , electronic / Mechanical governor, Manual & electric Start ,Batteries, Fuel tank ( with Stand) & piping , control panel (16 G) with MCCB (4P; 25 KA), Ammeter, Voltmeter, Frequency Meter, Energy Meter & Hour Meter, Engine instrumentsPanel, AVM and with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 2.0 mmCRCA sheet steel (structure) with side wall fabricated from 2.0 mm CRCA sheet & filled with 100mm thick glass wool(96Kg/m3) as per IS 8183 the doors of 100 mm thick and fabricated from 1.6mm CRCA sheet packed with accoustic material, floor of MS chequrred plate 5.0mmthick, canopy fixed with axial flow fan of Alstom, CG, Almonard make. All doors/ opening are sealed with neoprene/EPDN gaskets. The enclosure has residential silencer (isolated from main DG chamber) with protection and tripping of DG set against temperature of more than 50 degree centigrade. All controls for operation of DG set are from outside theenclosure with DG control panel mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level is less than 74 db(A) at a distance of 1 Mtrs. Complete in all respect of 500 kVA at 0.8 pf(lag) 415 V, 3 Ø, 50 Hz capacity .Method of cooling- Water.Method of aspiration - Turbo Charged2 - Control panel :- The control panel will be dust and vermin proof of sheet metal construction, floor mounting type suitable for indoor use in IP- 41 Enclosure. The control panel will comprises of Ø Voltmeter with selector switch.Ø Frequency meterØ KWH meterØ Kilowatt meterØ MOCB with overload shord circuit & under voltage protection starting push button & key switch ( ON/OFF)Ø Audio/ Visual alarm shut down for engine, protection for low lube oil pressure and high coolant temperature indicting lamps for low lube oil pressure high coolant temperature indicating lamps for low lube oil pressure high coolant temperature, set running and load on set be control on.Ø Instrument FusesØ 1.5 class CTs of suitable ratio.Ø Bus bar. AluminiumØ Cable entry gland without cable gland. |
| 140 | Auto Mains Failure Panel - Provision for PLC based AMF Panel fabricated from CRCA sheet steel 2 mm thick, powder coated finish, START & STOP commands, control relays, selector switches for Ammeter and Voltmeter, Ammeter & Voltmeter, Control & Power contactors, timers, electronic hooters, Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for above DG setFuel Tank : - Fuel tank 225 lit. capacity.Battery :- Batteries 12 volt180AH dry and uncharged with battery leads and battery charger |
| 141 | Earthing- Double earthing of DG set and all electrical equipment as per IS and IER |
| 142 | POWER CABLE/BUS BAR |
| 143 | Supplying and laying of Power cable of 185 sq. mm size of 1100 Volt grade 3.5 core armoured XLPE sheathed aluminium conductor from alternator of DG to AMF panel to LT panel |
| 144 | Supply and making end termination/joints of the above cable |
| 145 | INSTALLATION, COMMISSIONING AND TESTING |
| 146 | Installation of D.G. set, cable, AMF panel etc.at site |
| 147 | Commissioning of the above including supply of diesel and oil for trial |
| 148 | Testing of D.G set at manufacturer works |
| 149 | Provision of copper wound ISI marked Transformer 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type with Standard accessories like, conservator, Silicagel breather, radiator, fins, HT & LT cable end boxes or Bus Duct flange, Lifting lugs, Bi-directional Plain /Flanged Rollers,Earthing terminal,Air relaese plug, Off load tap changer (+5% to -10% in steps of 2.5%) , winding / Top oil temperature rise of 45°C/40°C, ISI marked drain valves, Dial type temperature gauge, first fill oil, Epoxy based paint etc conforming to IS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 BEE star level - I as per Govt. of India, Ministry of power notification Dated 16th Dec., 2016. Transformers described as above and as per the following continuous rating: 250 kVA |
| 150 | Supply of 11KV/800 amp. 3 phase, 3 wire 50 Hz H.T. VCB panel with all accessories including followingA- Incoming panel - 1 No.11 KV/800 Amp. 3 phase 50 Hz H.T. incoming panel in draw out version vacuum circuit breaker fitted with¨ 3 nos single phase current transformer of suitable ratio as per IS 2705¨ 1 no. 3 phase potential transformer of ratio 11KV/110 Volt as per IS 3156¨ 1 set of closing and tripping coil of suitable ratio¨ Mechanical ON/OFF indicator¨ Emergency Mechanical tripping through push lever¨ Rear/side entry cable box to accommodate suitable size of cable¨ Current, Voltage, KWH, P.F. meters¨ Indicating lamp assembly for breaker ON/OFF, tripping, spring charge.¨ Mechanical and electrical interlock¨ Over current and Earth fault relay etc. completeB- Out going panel - 2 NosH.T. out going panel for feeding two transformers similar to incoming panel but without following accessories¨ Volt meter, KWH meter, potential transformerC- Battery Charger with battery bank - 1 SetSelf-contained FCB charger suitable for operation from single phase 230 volts 50 C/S A.C. supply should be comprising ofPilot lamp.Transformer double wound with copper conductor vacuum impregnated.Rectifier Full wave single phase bridge connected selenium rectifier.Ammeter, Voltmeter, control ON/OFF cum selector switch.Fuses for necessary protection, test circuit for battery charger etc. complete.Suitable capacity battery bank |
| 151 | Power wiring |
| 152 | Supplying and laying of Power cable of 185 sq. mm size of 1100 Volt grade 3.5 core armoured XLPE sheathed aluminium conductor from transformers to LT panel. |
| 153 | Supply and making end termination/joints of the above cable |
| 154 | Supplying and laying of Power cable of 70 sq. mm size of 11000 Volt grade 3 core armoured XLPE sheathed aluminium conductor from UPPCL metering panel to transformers |
| 155 | Supply and making end termination of the above cable |
| 156 | Earthing of electrical equipments as per IS/ IER |
| 157 | Proper fencing of sub-station portion as per IE Rules |
| 158 | Charges of Electrical safety clearance. |
| 159 | Supply of 5 kg Capacity Dry Powder/ABC type fire extinguisher. |
| 160 | 12/20 mm. thick rubber electric resistance rubber sheet as per ISS. |
| 161 | Commissioning and testing including type test of the sub station equipment including first filling and centrifuging of oil in the installed equipment wherever necessary. |
| 162 | Battery and Battery Charger |
| 163 | Installation of H.T. panel, transformer, laying & jointing of H.T. cables from UPPCL meter to H.T. panel, from HT panel to individual transformers, LT cables from individual transformers to L.T. main panel etc. complete in all respect. |
| 164 | Testing at manufacturer works |
| 165 | Gravelling, provision of pathways, Platform for Transformers, sand filling in the trenches and providing chequered plates to cover the cable trenches. |
| 166 | 3 Month Trial Run |
| 167 | Diesel |
| 168 | Lubricants |