Tender For Electrical Work Of Sbi Surat Main Branch (00488), Chowk Bazaar, Surat, Surat-Gujarat

State Bank Of India has published Tender For Electrical Work Of Sbi Surat Main Branch (00488), Chowk Bazaar, Surat. Submission Date for this Tender is 24-07-2023. Electrical Maintenance Tenders in Surat Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

38686806
Tender For Electrical Work Of Sbi Surat Main Branch (00488), Chowk Bazaar, Surat
Tender
Indian
Gujarat
Surat
24-07-2023

Tender Details

Tender For Electrical Work Of Sbi Surat Main Branch (00488), Chowk Bazaar, Surat PART - A :::: BRANCH A INTERNAL WIRING :Phase wire must be Red colour for LDB, Yellow colour for PDB & Blue for ACDB, Neutral Wire of Black colour & Green Wire for Earthing. Color code must be maintained. Tagging from DB MCB and Switch board must be done. 1 SITC of point wiring in concealed in walls, furnitures & for above false ceiling, or on ceiling, on beams shall be fixed with saddles & spacers etc., with conduits taken in slab with 20 mm dia PVC Rigid conduits 1.5 mm thick ISI mark with 2 nos. of 1.5 sq. mm. phase & neutral & 1 nos. of 1.0 sq. mm. earthing with modular switch with company made flush metal box/surface PVC box etc. comp. with nec. main lines for switch board from LDB of mains of 2 nos. of 2.5 sq.mm wire and 1 no. of 1.0 sq mm pvc Insulated copper conductor wire FRLS type laying in with 20 mm/25 mm dia PVC rigid conduits 1.5 mm thick ISI mark .These will be used with point wiring of light, fan, ex. fan, call bell points, etc { Max. 3 Switchboards in one circuit - One Sp MCB }.Phase wire must be Red colour, Neutral Wire must be Black color & Green Wire for Earthing. Color code must be maintained. Tagging from Lighting DB MCB and Switch board must be done. 1.1 One 5A switch controlling one light / fan point. 6 nos 1.2 One switch controlling Two light points . 5 nos 1.4 5A socket outlet with 5A switch ( on common board ) (1 FOR WATER COOLER). 3 nos 1.5 5A socket outlet with 5A SP switch (as an independent point ) [ for ex. Fan, wall fan , QMS, Token M/C Display, etc. points.] 3 nos 1.7 SITC of loop light points 0f 2 nos. of 1.5 sq. mm. off wires & 1 nos. of 1.0 sq. mm. earth wire from Main panel timer of mains of 2 nos. of 2.5 sq.mm wire and 1 no. of 1.0 sq mm pvc Insulated copper conductor earth wire laying in with 20 mm/25 mm dia type PVC rigid conduits 1.5 mm thick ISI mark. ( This point is for Signage and Down Lighter Points at Entrance). 6 nos 2.2 SITC of 6/16 Amp. Switch and socket complete with necessary require wiring from PDB of 2 no of 4.0 sq mm wires and 1 no of 2.5 sq mm PVC Insulated copper conductor earth wire laying in with 20 mm/25 mm dia PVC rigid conduits 1.5 mm thick ISI mark. These will be used with point wiring of power points ,etc. . No Looping of Neutral or earthing is allowed. Each point needs to provide separate circuit. This Points Need to Be Connected through PDB. ( For Printer, Water Cooler, Freeze, Motor, Note Counting Machine points ). 1 nos 3 SITC of 20 A/ 25 A , 230 V, with DP ELCB, 100 mA all enclosed in a prefabricated M S boxes complete to the satisfaction of E.I.C. For SPLIT AC 1.5TR / 2.0 TR unit with necessary require wiring from ACDB of 2 no of 4.0 sq 3 nos mm wires and 1 no of 2.5 sq mm PVC Insulated copper conductor wire FRLS type laying in with 20 mm/25 mm dia PVC rigid conduits 1.5 mm thick ISI mark. These will be used with point wiring of A.C. points ,etc . Server Room AC Supply need to be given through Main Panel. Color code must be maintained. Tagging from DP MCB and AC point must be done. This point should be installed near Split / window AC in concealed manner. No Looping of Neutral or earthing is allowed. Each point needs to provide separate circuit. For Cassette AC power supply indoor or outdoor need to be given as per AC vendors requirement. The height of switchboard must be at reachable point for easily operation. from that point to Split AC, empty conduit + necessary bends must in concealed mode by ele. contractor. THE ENCLOSURE SHOULD BE SAME MAKE AS MCB MAKE. B LIGHTING FIXTURES : (NOTE : ANY OF FIXTURES AND FITINGS SHALL BE RE-CONFIRMED WITH THE ARCHITECTS / CONSULANTS BEFOTE ORDERING THEM. 4 SITC of (including supply and fixing flexible wires from holder to fixtures hardwares etc.) of…. - The LED lamps should be of same make as fixture make. - The marking & cutting of fixtures should be in ele. contractors scope.. fixtures should be approved by banks ele. engineer / ele. consultant / architect. from the given make list before installations. LM 79 & LM 80 test reports to be submitted. nichia / LUmileds / cree - LED should be used by manufacture. Lighting Luminaries of LED for Office single piece die cost aluminium M24 housing complete with driver unit, mirror optic and other accessories Lamps of about 100 lumen/W injection moulded PC diffusers with high brightness complete unit complying with international standard (LU49, LH801) - operative on 190V - 270 V 50 Hz with Mini 3 years warranty complete with mounting system and lamp dully wired and tested Details as under. 4.1 SITC of LED 1 x 31 W ( 3100 lumens ) ( 2 X 2) RECESS MOUNTED LUMINAIRE with 2KV surge protection, making earthing connection complete to be recessed in false ceiling with all necessary hardware, hanging - die cast frame arrangement, chains or hook arrangement with ceiling, connected to supply wire with PVC connector. Earthing connection with lugging need to given to body of Fixture, etc. complete. (Crompton Model ORION II Cat Ref No: LCTLRN-36-FO-CDL, CCT 6000 K and CRI > 80, lumen O/P > 3300 lumen, Syatem wattage (LED + Driver) < 40 Watt. or Equivalent in GE/ Philips / Havells / Wipro make) . 5 nos 4.1 Removal & reinstallation of existing LED 1 x 31 W ( 2 X 2) RECESS MOUNTED LUMINAIRE with making earthing connection complete to be recessed in false ceiling with all necessary hardwares, hanging - die cast frame arrangement, chains or hook arrangement with ceiling, connected to supply wire with PVC connector. Earthing connection with lugging need to given to body of Fixture, etc. complete. 2 nos 4.2 SITC of 1x12 W Square / Round LED DOWN LIGHT pressure die cast fixture with 2KV surge protection ( 950 lumens ) to be recessed in false ceiling with all necessary hardwares, chains, hook etc. complete.( CROMPTON make cat no. Crompton Model CROM LCDD-15-CDL/TL/ WW ,CCT 6000 K and CRI > 80,Lumen output1450 lumen, System wattage( LED + Driver ) 12 Watt or Equivalent in GE / Philips / Havells / Wipro make ). Energy Efficient round recessed mounted LED down lighter with premium white 6 nos powder coating and die cast aluminium housing. as per details above. Die casting material should not be CRCO type material. should be connected to supply wire with PVC connector. Earthing connection with lugging need to given to body of Fixture. 4.2 Removal & reinstallation of existing 1x12 W Square / Round LED DOWN LIGHT pressure die cast fixture with to be recessed in false ceiling with all necessary hardwares, chains, hook etc. complete. should be connected to supply wire with PVC connector. Earthing connection with lugging need to given to body of Fixture. 3 nos 4.3 SITC of Exhaust fan of 300 mm, fresh air ventilator type complete & 6 Amp. 3 pin TOP. (Crompton/ Khaitan / Havells make) [Wooden mounting frame should be fixed in coordination with carpenter - furniture contractor.] - Two Ex. Fan is of heavy duty industrial for Ups room. 2 nos 4.4 SITC of Decorative 3 W ( 180 lumens ) LED DOWN LIGHT PANEL with its driver also. ( Wipro make or Philips or equivalent co. make). (Approved by Architect) basic rate of fixture Rs. 900/-. ( This is for down lighter in ACP work near entrance ). 6 nos C COMPUTER POWER SUPPLY & NETWORKING - TELE. SYSTEM.: Phase wire must be Yellow colour for UPS O/P DB, Red colour for PDB , Neutral Wire of Black colour & Green Wire for Earthing. Color code must be maintained. Tagging from DB MCB and Switch board must be done. 5 SITC of 2 nos. of 6 A, 5 pin Sockets and 1 no. of 6 16 A socket below table outlets with one 16 A switche with indicator Computer power supply with concealed company made metallic boxes or PVC flush box on walls / furnitures / trunking etc complete all respect with necessory wiring of mains of 2 no of 2.5 sq mm and 1 no of 1.5 sqmm pvc insulated copper conductor multi-stranded flexible wire with 20/25 dia. PVC conduits with accessories duly burried under floor with necessary chasing / breaking in floor and to be refinished with all necessary civil material etc. complete from UPSDB to Computer power supply boards.{Maxi. 3 computers in one circuit}. complete with necessary termination etc. complete.[ White Colour Outer Plate For These Switchboards]. LOOP POINTS MUST BE OF SAME SIZED WIRES. Phase wire must be Red colour, Neutral Wire must be Black color & Green Wire for Earthing. Color code must be maintained. Tagging from UPS O/P DB MCB and Switch board must be done. 10 nos 6 SITC of 2 nos. of 6 A, 5 pin Sockets and 1 no. of with one 6 A switches raw power supply with concealed company made metallic boxes or PVC flush box on walls / furnitures / trunking etc complete all respect with necessary wiring of mains of 2 no of 2.5 sq mm and 1 no of 1.5 sq mm pvc insulated copper conductor multi-stranded flexible wire with 20/25 dia. PVC conduits with accessories duly burried under floor with necessary chasing / breaking in floor and to be refinished with all necessary civil material etc. complete from PDB to Computer power supply boards.{Maxi. 3 Raw Power Points in one circuit}. complete with necessary termination etc. complete.. [ Black Colour Outer Plate For These Switchboards].LOOP POINTS MUST BE OF SAME SIZED WIRES. Phase 4 nos wire must be Red colour, Neutral Wire must be Black color & Green Wire for Earthing. Color code must be maintained. Tagging from PDB MCB and Switch board must be done. 7 SITC of CAT 6, RJ 45 information outlet (I/O) of D-link make with front modular cover plate, flush box metallic or PVC for trucking system etc. complete with terminations etc complete. with Providing, installing, testing, commissioning of CAT 6 UTP pvc insulated copper conductor data cable of D-link make with 20/25 dia. PVC conduits with accessories duly burried under floor with necessary chasing / breaking in floor and to be refinished with all necessary civil material etc. or to be cleated on wall / ceiling with saddles / spacer etc. necessary termination etc. with ferrule numbering at both ends of each of piece of cable etc. complete as per the requirement from data rack to I/O points below tables. etc. ( One for LCD & Two for ATM & one for IP phone in BM cabin). Dual jack plate will not be allowed. Cross Ferruling need to be provided for each point. on Data point tagging must be done). 16 nos 8 Supply & fixing the Patch cord 1 m Long (factory built) .-When supplying , then first ask to BM / Consultant / Architect / Bank Authority. 16 nos 9 Supply & fixing the Patch cord 2 m Long (factory built) .-When supplying , then first ask to BM / Consultant / Architect / Bank Authority. 9 nos D DISTRIBUTION BOARD AND PANELS : 10 SITC of metallic double door type distribution board with all necessary connection complete to be installed concealed in wall / surface mount complete to the satisfaction of the Engineer in charge. The DB should be of same make as MCB make. 10.1 12 - WAY SPN DB : ( ATMDB ). All MCB should be C type. NEW. 1 nos incoming : 40 A FP MCB - 1 NO . outgoing : 20 A / 25 A DP MCB (1 nos ) for HI- WALL SPLIT AC points. outgoing : 20 A / 25 A DP MCB (1 nos ) for UPS I/P DB. Outgoing : 10 to 20 A SP MCB (1 nos ). For raw power point. outgoing : 10 to 20 A SP MCB (1 nos ). For lighting sb of E Lobby. 10.2 4 WAY SPN DB . (For ATM ups points - UPS O/P DB - in ATM AREA. ). 1 nos outgoing : 25 A. DP MCB - 1 NO FOR UPS OUTPUT. outgoing : 10 A / 20 A. SP MCB - 2 Nos. 10.3 4 WAY SPN DB . (For ATM UPS DB. AT UPS ROOM). 1 nos outgoing : 25 A. DP MCB - 1 NO FOR UPS INPUT. outgoing : 25 A. DP MCB - 1 NO FOR UPS OUTPUT. F CABLES & CABLE TERMINATIONS: 11 Supply, Laying, installation, testing and commissioning of following sizes of PVC insulated PVC sheathed copper / aluminum conductor armored cable to be laying in existing cable trench or to be laid in existing pipes of with necessary clamps, spacers with cleating on wall ceiling etc. complete to the satisfaction of EIC. All types of cable excavation works should be in contractors scope.( LENTH TO BE VERIFY AT SITE ) with end termination of following PVC insulated armoured cables including supply and fixing of brass single compression type cable glands and crimping type aluminum / copper lugs suitable for terminations of armored cables of following overall diameters, incl. 12 4 C x 16.0 sq mm Alu. Conductor AYFY cable. ( Main Panel to ATM DB.) 30 m 13 3 C X 4.0 sq. mm flexible Cu. cable with 20 mm/25 mm dia PVC rigid conduits 1.5 mm thick ISI mark . ( UPS to UPS O/P DB & UPS I/P DB to UPS). - for ATM. 20 m G MISCELLANEOUS ITEMS : 14 Supply an installation of 24 Hr, 7 days A/C timer with 2 nos. power connector of M.D.S, L & T ,SEIMENS,THEBEN ( indoasian) Make. All enclosed in sheet steel powder coated enclosure of 400 X 400 mm complete with all necessary termination for E lobby AC. Here Ready made Cyclic Timer Will not be permitted. 1 nos 15 Supply an installation of 24 Hr, 7 days A/C timer with 2 nos. DP power connector of M.D.S, L & T ,SEIMENS,THEBEN (indoasian) Make. All enclosed in sheet steel powder coated enclosure of 400 X 400 mm complete with all necessary termination for ups room ex. fans. Here Ready made Cyclic Timer Will not be permitted. 1 nos 16 Removal of old wiring in area which will be proposed to be redesigned & providing Necessary plug points & light points for tube lights (including necessary wiring) at various locations as required by various contractors for execution of various works / to run equipments such as drill / cutter etc. during the entire execution process. The accessories used for this purpose shall be of temp. nature (anchor piano or eq.) & the contractor has to take back the same on completion of the project. The supply for this shall be taken from the temporary connection provided at / from nearby general meter under coordination with the LANDLORD. & also providing temporary power supply for computers and data connection for computers with wiring, switchboard, Comp. I/O Points, etc. for smoothly running of the branch with removing & re-shifting of the computers , printers, etc. bank hardware accessories. 1 job

Key Value

Document Fees
Refer document
EMD
INR 1000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail