Tender For Construction Of Various Buildings For Establishment Of Strawberry Research Station At Mahabaleshwar Under Rkvy Project For Mahatma Phule Krishi Vidyapeeth, Rahuri
Tender Value
1.50 Crore
Estimated cost
Bid Submission
08 Aug 2023
0 days left
EMD
1.50 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
mahabaleshwar → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Various Buildings For Establishment Of Strawberry Research Station At Mahabaleshwar Under Rkvy Project For Mahatma Phule Krishi Vidyapeeth, Rahuri
BOQ
| Sl. No. | Item Description |
| 1 | Construction of Various buildings for establishment of strawberry Research Station at Mahabaleshwar under RKVY Project for Mahatma Phule Krishi Vidyapeeth, Rahuri |
| 2 | Construction of working shed for Nursery at Strawberry Research Station under RKVY Project at Mahabaleshwar, Dist. Satara.Removinggrass,gazergrassand disposingoffoutofbuildingpremisesincludingmaking clean the ground by shovel and phavaras etc. complete. |
| 3 | Hiring 76 HP JCB machine on Machine Hrs. Basis for preparation of formation of play ground including cutting thorny bushesh, removing big boulders & conveying, dozing, Levelling as directed by Engineer in charge including Diesel, Operator, transportation including all machinery, labour and taxes etc. complete. |
| 4 | Excavationforfoundationinearth,soil ofalltypes,sand,gravelandsoft murum,includingremovingtheexcavated material upto adistanceof50m.beyond the building area & stacking and spreading asdirected,dewatering,preparingthebed forthefoundationandnecessaryback filling,ramming,wateringincludingshoring andstruttingetc.complete. (Liftupto1.5 m.)By Manual Means Spec. No.: Bd.A.1 Page No. 259 |
| 5 | ExcavationforfoundationinHard murumandbouldersincludingremoving the excavated materials upto a distance 50 metres,beyondthebuildingareaand stackingandspreadingasdirected dewateringpreparingthebedforthe oundationandnecessarybackfilling, ramming,wateringincludingshoringand strutting etc. complete. (Lift upto 1.5m.)By Manual Means Spec. No.: Bd.A.3 Page No. 259 |
| 6 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering,preparingthebedforthefoundationandnecessarybackfillingwithavailableearth/murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m)By Mechanical Means |
| 7 | Providingandlayinginsitu, cementconcretein M-10 oftrap/granite/quartzite/gneissmetalfor foundationand bedding includingbailingout water, formwork, compacting and curing complete, withfullyautomaticmicroprocessorbasedPLC with SCADA enabled reversible Drum Type mixer, with natural sand. Spec. No.: Bd. E. 1 Page No. 287 |
| 8 | Providingandlayinginsitu cement concreteM-20of trap /granite/quartzite/ gneissmetalforR.C.C.work in foundationslikeraft,stripfoundations, grillageandfootingsofR.C.C.columns and steel stanchionsetc. including bailing outwater,formwork,coverblocks compactionandcuringrougheningthe surfaceifspecialfinishistobeprovided (Excludingreinforcementandstructural steel)complete,Withfullyautomaticmicro processor based PLC with SCADA enabled reversibledrumtypeconcretemixer. With natural sand. Spec.No.:Bd.F.3PageNo.298andB.7, Page No.38 |
| 9 | Providingandcastinginsitucement concreteM-20 oftrap/granite/quartzite/ gneissmetal forR.C.C.columns asper detailed designs and drawing or as directed includingcentering,formwork,coverblocks compactingandrougheningthesurfaceif specialfinishistobeprovidedandcuring complete.(Excludingreinforcement).With fullyautomaticmicroprocessorbasedPLC withSCADA enabledreversibledrumtype concrete mixer. With natural sand. Spec.No.:Bd.F.5PageNo.300andB.7, Page.No. 38 |
| 10 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) |
| 11 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 12 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.chajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) |
| 13 | Filling in plinth and floors with approved excavatedmaterials in15cmto20cm layersincludingwateringandcompaction complete.Spec. No.: Bd.A.10 Page No. 262 |
| 14 | Fillinginplinthandfloorswith contractors soil sand or murum in 15 cm to20cm,layersincludingwateringandcompaction complete.Spec. No.: Bd.A.11 Page No. 263 |
| 15 | Providingdry/trap/ granite/quartzite/ gneissrubblestonesoling 15cmto20 cmthickincludinghandpackingand compacting complete. Spec. No.: Bd.A. 12 Page No. 264 |
| 16 | Providingandcastingin situcementconcreteinM-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sillof doors and windows moulded as per detailed drawings or chamfered as approved by the Engineerincluding centering, formwork,cover blocks compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement).withConcrete concretemixerWith ------ sand. Spec. No.: Bd. F. 12 Page No. 304 & B-7, Pg 38 |
| 17 | Providing and fixing in position TMT - FE - 500Metric bar reinforcement ofvarious diameters for Tonne R.C.C.pile caps, footings,foundations, slabs, beams columns, canopies, staircase,newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending,hooking the bars, binding withwires or tackwelding and supporting as required complete.Spec. No.: Bd.F.17, Page No. 306 (Page No. 52, I.No.8/5 BDE 17) |
| 18 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6 insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete |
| 19 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mmthickincementmortar1:4using waterproofingcompoundat1kgper cementbagcuringthesamefornotless than 2 days and keeping the surface of the basecoatroughtoreceivethesandfaced treatment 6 to 8 mm thick in cement mortar 1:4finishingthesurfacebytakingout grainsandcuringforfourteendays scaffolding etc.complete. Spec. No.: Bd.L.7 Page No. 369 |
| 20 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:4without neerufinish,to concrete,bricksurface,inallpositionsincludingscaffoldingandcuring etc.complete. |
| 21 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gusset platesetc.asperdetaileddesignsanddrawingsorasdirectedincluding cutting,fabricating,hoisting, erecting fixing in position, Making riveted/ bolted/ weldedconnection and onecoatofanticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. |
| 22 | Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt.totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength,metallichotdipcoatedwith Aluminium-Zincalloy(55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality superdurablepolyesterpaintcoat(withinorganic pigment). The paint shall have a total coating thicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center.The endribshallbedesignedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) |
| 23 | ProvidingandfixingOrissatypewhiteglazedearthenware575mmwaterclosetpan including S trap withearthenware footrests,castironsoilandventpipe uptooutside face ofthe wall 1:2:4brick batlime concrete bedding without flushing tank and its accessories etc. complete. |
| 24 | Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006(Group-BIIA)forantiskidflooringinrequiredpositionlaidonabedof1:4cementmortar including cement float, filling joint with cement slurry cleaning curing etc. complete. |
| 25 | Providing and laying ceramic tileshaving size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
| 26 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and patternfordadoandskirting inrequiredpositionfixedin1:4cementmortarincludingneatcementfloat, filling joints, curing and clearingetc. complete |
| 27 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequired widthinplain/diamondpatternonbed of1:6 C.M.including cementfloat, filling joints withneat cement slurry, curing, polishing and cleaningetc. complete. |
| 28 | Providing and fixing steel frame of angle 50 x 50 x 6 mm size for window with 16 mm with mild steel bars horizontally at 10 cm c/c for ventilator portion and at 15 cm c/c for remaining portion with M.S. flat of size 40 x 6 mm vertical at center including iron hold fast boxes for fixing40x6mmverticalatcenterincluding iron hold fastboxesforfixing40 x 6 mm verticalat centerincluding ironholdfastboxes forfixing shutters including welding finishing painting etc. complete. |
| 29 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldingsandlipping,wroughtironholdfasts,chromiumplated fixtures and fastenings, with brass mortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete. |
| 30 | Providingandfixingfiberglassreinforcedpolysterdoorshutter30mmthickasperIS14856(2000) (Reaffirmed2006)withoutventilatorincluding chromiumplatedfixturesandfasteningwith chromium plated handles on both sides, etc. complete |
| 31 | Providing andfixing mild steelgrill workfor windows,ventilators etc.20 Kilogram/Square Metre as per drawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete. |
| 32 | Providing andfixing in position powder coated aluminium louvered windows / ventilator of varioussizes withpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38 mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. |
| 33 | Providing andfixing inposition.(asperI.S.1868/ 1982)Aluminium sliding window oftwo tracks with rectangularpipe having overalldimension63.50x38.10x1.02mm atweight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight 0.695Kilogram/Running metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.As per detailed drawings and as directed by Engineer in chargewithallnecessaryAluminiumsections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section ofshutterincluding 5mm thickplainglasswithallrequiredscrewsandnutsetc,complete.Withpowder coating with box |
| 34 | Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSYPAVING BLOCKSof60millimeterthicknessofhavingastrengthof400Kilogram/sq.mofapprovedqualityand shapeonabedofcrushedsandof25to30millimeterthickincludingstrikingjointsandcleaning etc. complete. (using 100% crushed sand) |
| 35 | ProvidingandfixingwhiteglazedearthenwareWashHandBasinof55cm.x40cm.size including coldwaterpillartap/coldandhotwaterpillartapbrackets,rubberplugsandbrasschain,stoptapand necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. |
| 36 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. As directed by Engineer Incharge |
| 37 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 38 | Providingandfixing15mm dia.screwdownbib/stoptapofbrassincluding necessarysocketunionnut complete. |
| 39 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and builtcorrugatedinclusiveofdeliveryuptodestinationhoistingand fixing of accessories such as inlet,outletoverflowpipeinclusiveofalltankscapacity between 200 to 1000 liters |
| 40 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparingthesurfacebythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete. |
| 41 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old andnewsurfaces intwocoatsincludingscaffolding,preparingthesurface.(excludingthe primer coat)etc. complete. |
| 42 | Providingand applyingtwocoatsof waterproofcementpaintofapproved manufactureandofapprovedcolourto theplasteredsurfacesincluding scaffoldingifnecessary,cleaningand preparing the surface, watering for two days complete.Spec. No.: Bd.0.8 Page No. 406 |
| 43 | Add for Royalty Charges |
| 44 | Quality Control Charges - CEMENT. - i) Compressive Strength. ii) Initial Setting Time. iii) Final setting Time. iv) Specific Gravity. v) Soundness.vi)Fineness vii)Workability. |
| 45 | BRICK.- i) Compressive Strength. ii) Water absorption. |
| 46 | Footing, Column, Beam -Compressive Strength OF C.C. Cube(Set of 3 cubes). |
| 47 | STEELi) Ultimate Tensile Stress. ii) Percentage Elongation iii) (Yeild Stress) Proof Stress. iv) Weight per meter. |
| 48 | Construction of Packing and Grading shed at Strawberry Research Station under RKVY Project at WRRS, Mahabaleshwar, Dist. Satara.Excavationforfoundationinearth,soil ofalltypes,sand,gravelandsoft murum,includingremovingtheexcavated material upto adistanceof50m.beyond the building area & stacking and spreading asdirected,dewatering,preparingthebed forthefoundationandnecessaryback filling,ramming,wateringincludingshoring andstruttingetc.complete. (Liftupto1.5 m.)By Manual Means Spec. No.: Bd.A.1 Page No. 259 |
| 49 | ExcavationforfoundationinHard murumandbouldersincludingremoving the excavated materials upto a distance 50 metres,beyondthebuildingareaand stackingandspreadingasdirected dewateringpreparingthebedforthe oundationandnecessarybackfilling, ramming,wateringincludingshoringand strutting etc. complete. (Lift upto 1.5m.)By Manual Means Spec. No.: Bd.A.3 Page No. 259 |
| 50 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering,preparingthebedforthefoundationandnecessarybackfillingwithavailableearth/murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m)By Mechanical Means |
| 51 | Providingandlayinginsitu, cementconcretein M-10 oftrap/granite/quartzite/gneissmetalfor foundationand bedding includingbailingout water, formwork, compacting and curing complete, withfullyautomaticmicroprocessorbasedPLC with SCADA enabled reversible Drum Type mixer, with natural sand. Spec. No.: Bd. E. 1 Page No. 287 |
| 52 | Providingandlayinginsitu cement concreteM-20of trap /granite/quartzite/ gneissmetalforR.C.C.work in foundationslikeraft,stripfoundations, grillageandfootingsofR.C.C.columns and steel stanchionsetc. including bailing outwater,formwork,coverblocks compactionandcuringrougheningthe surfaceifspecialfinishistobeprovided (Excludingreinforcementandstructural steel)complete,Withfullyautomaticmicro processor based PLC with SCADA enabled reversibledrumtypeconcretemixer. With natural sand. Spec.No.:Bd.F.3PageNo.298andB.7, Page No.38 |
| 53 | Providingandcastinginsitucement concreteM-20 oftrap/granite/quartzite/ gneissmetal forR.C.C.columns asper detailed designs and drawing or as directed includingcentering,formwork,coverblocks compactingandrougheningthesurfaceif specialfinishistobeprovidedandcuring complete.(Excludingreinforcement).With fullyautomaticmicroprocessorbasedPLC withSCADA enabledreversibledrumtype concrete mixer. With natural sand. Spec.No.:Bd.F.5PageNo.300andB.7, Page.No. 38 |
| 54 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) |
| 55 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal forR.C.C.chajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) |
| 56 | Filling in plinth and floors with approved excavatedmaterials in15cmto20cm layersincludingwateringandcompaction complete.Spec. No.: Bd.A.10 Page No. 262 |
| 57 | Fillinginplinthandfloorswith contractors soil sand or murum in 15 cm to20cm,layersincludingwateringandcompaction complete.Spec. No.: Bd.A.11 Page No. 263 |
| 58 | Providingdry/trap/ granite/quartzite/ gneissrubblestonesoling 15cmto20 cmthickincludinghandpackingand compacting complete. Spec. No.: Bd.A. 12 Page No. 264 |
| 59 | Providingandcastingin situcementconcreteinM-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sillof doors and windows moulded as per detailed drawings or chamfered as approved by the Engineerincluding centering, formwork,cover blocks compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement).withConcrete concretemixerWith ------ sand. Spec. No.: Bd. F. 12 Page No. 304 & B-7, Pg 38 |
| 60 | Providing and fixing in position TMT - FE - 500Metric bar reinforcement ofvarious diameters for Tonne R.C.C.pile caps, footings,foundations, slabs, beams columns, canopies, staircase,newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending,hooking the bars, binding withwires or tackwelding and supporting as required complete.Spec. No.: Bd.F.17, Page No. 306 (Page No. 52, I.No.8/5 BDE 17) |
| 61 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6 insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete |
| 62 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mmthickincementmortar1:4using waterproofingcompoundat1kgper cementbagcuringthesamefornotless than 2 days and keeping the surface of the basecoatroughtoreceivethesandfaced treatment 6 to 8 mm thick in cement mortar 1:4finishingthesurfacebytakingout grainsandcuringforfourteendays scaffolding etc.complete. Spec. No.: Bd.L.7 Page No. 369 |
| 63 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:4without neerufinish,to concrete,bricksurface,inallpositionsincludingscaffoldingandcuring etc.complete. |
| 64 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gusset platesetc.asperdetaileddesignsanddrawingsorasdirectedincluding cutting,fabricating,hoisting, erecting fixing in position, Making riveted/ bolted/ weldedconnection and onecoatofanticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. |
| 65 | Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt.totalon each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength,metallichotdipcoatedwith Aluminium-Zincalloy(55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality superdurablepolyesterpaintcoat(withinorganic pigment). The paint shall have a total coating thicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center.The endribshallbedesignedforanti-capillarygroove.andreturnleg.Thefeed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/Square Metre) |
| 66 | Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness andconfirming to IS. 15622-2006( groupBla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneat cementfloat,fillingjoints,curingandclearing etc. complete. |
| 67 | Providing and fixing steel frame of angle 50 x 50 x 6 mm size for window with 16 mm with mild steel bars horizontally at 10 cm c/c for ventilator portion and at 15 cm c/c for remaining portion with M.S. flat of size 40 x 6 mm vertical at center including iron hold fast boxes for fixing40x6mmverticalatcenterincluding iron hold fastboxesforfixing40 x 6 mm verticalat centerincluding ironholdfastboxes forfixing shutters including welding finishing painting etc. complete. |
| 68 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldingsandlipping,wroughtironholdfasts,chromiumplated fixtures and fastenings, with brass mortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete. |
| 69 | Providing andfixing mild steelgrill workfor windows,ventilators etc.20 Kilogram/Square Metre as per drawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete. |
| 70 | Providing andfixing inposition.(asperI.S.1868/ 1982)Aluminium sliding window oftwo tracks with rectangularpipe having overalldimension63.50x38.10x1.02mm atweight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight 0.695Kilogram/Running metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.As per detailed drawings and as directed by Engineer in chargewithallnecessaryAluminiumsections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section ofshutterincluding 5mm thickplainglasswithallrequiredscrewsandnutsetc,complete.Withpowder coating with box |
| 71 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparingthesurfacebythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete. |
| 72 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old andnewsurfaces intwocoatsincludingscaffolding,preparingthesurface.(excludingthe primer coat)etc. complete. |
| 73 | Providingand applyingtwocoatsof waterproofcementpaintofapproved manufactureandofapprovedcolourto theplasteredsurfacesincluding scaffoldingifnecessary,cleaningand preparing the surface, watering for two days complete.Spec. No.: Bd.0.8 Page No. 406 |
| 74 | Add for Royalty Charges |
| 75 | Quality Control Charges- CEMENT. - i) Compressive Strength. ii) Initial Setting Time. iii) Final setting Time. iv) Specific Gravity. v) Soundness.vi)Fineness vii)Workability. |
| 76 | BRICK.- i) Compressive Strength. ii) Water absorption. |
| 77 | Footing, Column, Beam -Compressive Strength OF C.C. Cube(Set of 3 cubes). |
| 78 | STEELi) Ultimate Tensile Stress. ii) Percentage Elongation iii) (Yeild Stress) Proof Stress. iv) Weight per meter. |
| 79 | Construction of Training cum Demonstration Hall at Strawberry Research Station under RKVY Project at , Mahabaleshwar, Dist. Satara.Removinggrass,gazergrassand disposingoffoutofbuildingpremisesincludingmaking clean the ground by shovel and phavaras etc. complete. |
| 80 | Hiring 76 HP JCB machine on Machine Hrs. Basis for preparation of formation of play ground including cutting thorny bushesh, removing big boulders & conveying, dozing, Levelling as directed by Engineer in charge including Diesel, Operator, transportation including all machinery, labour and taxes etc. complete. |
| 81 | Excavationforfoundationinearth,soil ofalltypes,sand,gravelandsoft murum,includingremovingtheexcavated material upto adistanceof50m.beyond the building area & stacking and spreading asdirected,dewatering,preparingthebed forthefoundationandnecessaryback filling,ramming,wateringincludingshoring andstruttingetc.complete. (Liftupto1.5 m.)By Manual Means Spec. No.: Bd.A.1 Page No. 259 |
| 82 | ExcavationforfoundationinHard murumandbouldersincludingremoving the excavated materials upto a distance 50 metres,beyondthebuildingareaand stackingandspreadingasdirected dewateringpreparingthebedforthe oundationandnecessarybackfilling, ramming,wateringincludingshoringand strutting etc. complete. (Lift upto 1.5m.)By Manual Means Spec. No.: Bd.A.3 Page No. 259 |
| 83 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering,preparingthebedforthefoundationandnecessarybackfillingwithavailableearth/murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m)By Mechanical Means |
| 84 | Providingandlayinginsitu, cementconcretein M-10 oftrap/granite/quartzite/gneissmetalfor foundationand bedding includingbailingout water, formwork, compacting and curing complete, withfullyautomaticmicroprocessorbasedPLC with SCADA enabled reversible Drum Type mixer, with natural sand. Spec. No.: Bd. E. 1 Page No. 287 |
| 85 | Providingandlayinginsitu cement concreteM-20of trap /granite/quartzite/ gneissmetalforR.C.C.work in foundationslikeraft,stripfoundations, grillageandfootingsofR.C.C.columns and steel stanchionsetc. including bailing outwater,formwork,coverblocks compactionandcuringrougheningthe surfaceifspecialfinishistobeprovided (Excludingreinforcementandstructural steel)complete,Withfullyautomaticmicro processor based PLC with SCADA enabled reversibledrumtypeconcretemixer. With natural sand. Spec.No.:Bd.F.3PageNo.298andB.7, Page No.38 |
| 86 | Providingandcastinginsitucement concreteM-20 oftrap/granite/quartzite/ gneissmetal forR.C.C.columns asper detailed designs and drawing or as directed includingcentering,formwork,coverblocks compactingandrougheningthesurfaceif specialfinishistobeprovidedandcuring complete.(Excludingreinforcement).With fullyautomaticmicroprocessorbasedPLC withSCADA enabledreversibledrumtype concrete mixer. With natural sand. Spec.No.:Bd.F.5PageNo.300andB.7, Page.No. 38 |
| 87 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) |
| 88 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 89 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal forR.C.C.chajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) |
| 90 | ProvidingandlayingCastinsitu/ReadyMixcementconcretein M-20oftrap/quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawingsoras directedincludingsteelcentering, formwork,steelprops,laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface orrougheningthesurfaceifspecialfinish istobeprovided andcuringetc.complete.(Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.)withfully automaticmicro processorbasedPLCwithSCADAenabledreversibleDrum Typemixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 91 | Filling in plinth and floors with approved excavatedmaterials in15cmto20cm layersincludingwateringandcompaction complete.Spec. No.: Bd.A.10 Page No. 262 |
| 92 | Fillinginplinthandfloorswith contractors soil sand or murum in 15 cm to20cm,layersincludingwateringand compaction complete.Spec. No.: Bd.A.11 Page No. 263 |
| 93 | Providingdry/trap/ granite/quartzite/ gneissrubblestonesoling 15cmto20 cmthickincludinghandpackingand compacting complete. Spec. No.: Bd.A. 12 Page No. 264 |
| 94 | Providingandcastingin situcementconcreteinM-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sillof doors and windows moulded as per detailed drawings or chamfered as approved by the Engineerincluding centering, formwork,cover blocks compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement).withConcrete concretemixerWith ------ sand. Spec. No.: Bd. F. 12 Page No. 304 & B-7, Pg 38 |
| 95 | Providing and fixing in position TMT - FE - 500Metric bar reinforcement ofvarious diameters for Tonne R.C.C.pile caps, footings,foundations, slabs, beams columns, canopies, staircase,newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending,hooking the bars, binding withwires or tackwelding and supporting as required complete.Spec. No.: Bd.F.17, Page No. 306 (Page No. 52, I.No.8/5 BDE 17) |
| 96 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6 insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete |
| 97 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mmthickincementmortar1:4using waterproofingcompoundat1kgper cementbagcuringthesamefornotless than 2 days and keeping the surface of the basecoatroughtoreceivethesandfaced treatment 6 to 8 mm thick in cement mortar 1:4finishingthesurfacebytakingout grainsandcuringforfourteendays scaffolding etc.complete. Spec. No.: Bd.L.7 Page No. 369 |
| 98 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:4without neerufinish,to concrete,bricksurface,inallpositionsincludingscaffoldingandcuring etc.complete. |
| 99 | Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness andconfirming to IS. 15622-2006( groupBla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneat cementfloat,fillingjoints,curingandclearing etc. complete. |
| 100 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and patternfordadoandskirting inrequiredpositionfixedin1:4cementmortarincludingneatcementfloat, filling joints, curing and clearingetc. complete |
| 101 | Providing and fixing steel frame of angle 50 x 50 x 6 mm size for window with 16 mm with mild steel bars horizontally at 10 cm c/c for ventilator portion and at 15 cm c/c for remaining portion with M.S. flat of size 40 x 6 mm vertical at center including iron hold fast boxes for fixing40x6mmverticalatcenterincluding iron hold fastboxesforfixing40 x 6 mm verticalat centerincluding ironholdfastboxes forfixing shutters including welding finishing painting etc. complete. |
| 102 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldingsandlipping,wroughtironholdfasts,chromiumplated fixtures and fastenings, with brass mortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete. |
| 103 | ProvidingandfixingM.S.grilldoor24Kilogram/SquareMetreofvarioussizeasperdetaileddrawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc |
| 104 | Providing andfixing mild steelgrill workfor windows,ventilators etc.20 Kilogram/Square Metre as per drawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and two coats of oil painting complete. |
| 105 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / OceanBrown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. |
| 106 | Providing andfixing inposition.(asperI.S.1868/ 1982)Aluminium sliding window oftwo tracks with rectangularpipe having overalldimension63.50x38.10x1.02mm atweight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight 0.695Kilogram/Running metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.As per detailed drawings and as directed by Engineer in chargewithallnecessaryAluminiumsections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section ofshutterincluding 5mm thickplainglasswithallrequiredscrewsandnutsetc,complete.Withpowder coating with box |
| 107 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparingthesurfacebythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete. |
| 108 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old andnewsurfaces intwocoatsincludingscaffolding,preparingthesurface.(excludingthe primer coat)etc. complete. |
| 109 | Providing and applying two coats of exteriorweather shield paint of approved manufacture andofapproved colourtotheplasteredsurfacesincludingcleaning,preparingtheplaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etccomplete. NOTE: For Item Number 15 to 18 prior approval of Superintending Engineer will be necessary |
| 110 | Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSYPAVING BLOCKSof60millimeterthicknessofhavingastrengthof400Kilogram/sq.mofapprovedqualityand shapeonabedofcrushedsandof25to30millimeterthickincludingstrikingjointsandcleaning etc. complete. (using 100% crushed sand) |
| 111 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laidinrequiredslopetodrainthewaterforanyspanaftercleaningthebasesurface.Applyingacoatof cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layerfor3days,applyingcementslurryoverthislayerjointsofbrickbatswithC.M.1:3admixedwith approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed withapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldat thejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofness onCourtfeestamppaperofRs.500/- including ponding test etc. complete. |
| 112 | ProvidingandfixingP.V.C.Rainwaterpipesof110mmouterdiameterandhavingwall thicknessof2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.or masonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings andadditional 2 piece socket clips shall be got approvedfrom engineer in charge etc. complete. |
| 113 | Add for Royalty Charges |
| 114 | Quality Control Charges-CEMENT. - i) Compressive Strength. ii) Initial Setting Time. iii) Final setting Time. iv) Specific Gravity. v) Soundness.vi)Fineness vii)Workability. |
| 115 | BRICK.- i) Compressive Strength. ii) Water absorption. |
| 116 | Footing, Column, Beam -Compressive Strength OF C.C. Cube(Set of 3 cubes). |
| 117 | STEELi) Ultimate Tensile Stress. ii) Percentage Elongation iii) (Yeild Stress) Proof Stress. iv) Weight per meter. |
| 118 | Constructon of Trainees Hostel at Strawberry Research Station under RKVY Project at WRRS, Mahabaleshwar.Removinggrass,gazergrassand disposingoffoutofbuildingpremisesincludingmaking clean the ground by shovel and phavaras etc. complete. |
| 119 | Hiring 76 HP JCB machine on Machine Hrs. Basis for preparation of formation of play ground including cutting thorny bushesh, removing big boulders & conveying, dozing, Levelling as directed by Engineer in charge including Diesel, Operator, transportation including all machinery, labour and taxes etc. complete. |
| 120 | Excavationforfoundationinearth,soil ofalltypes,sand,gravelandsoft murum,includingremovingtheexcavated material upto adistanceof50m.beyond the building area & stacking and spreading asdirected,dewatering,preparingthebed forthefoundationandnecessaryback filling,ramming,wateringincludingshoring andstruttingetc.complete. (Liftupto1.5 m.)By Manual Means Spec. No.: Bd.A.1 Page No. 259 |
| 121 | ExcavationforfoundationinHard murumandbouldersincludingremoving the excavated materials upto a distance 50 metres,beyondthebuildingareaand stackingandspreadingasdirected dewateringpreparingthebedforthe oundationandnecessarybackfilling, ramming,wateringincludingshoringand strutting etc. complete. (Lift upto 1.5m.)By Manual Means Spec. No.: Bd.A.3 Page No. 259 |
| 122 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering,preparingthebedforthefoundationandnecessarybackfillingwithavailableearth/murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m)By Mechanical Means |
| 123 | Providingandlayinginsitu, cementconcretein M-10 oftrap/granite/quartzite/gneissmetalfor foundationand bedding includingbailingout water, formwork, compacting and curing complete, withfullyautomaticmicroprocessorbasedPLC with SCADA enabled reversible Drum Type mixer, with natural sand. Spec. No.: Bd. E. 1 Page No. 287 |
| 124 | Providingandlayinginsitu cement concreteM-20of trap /granite/quartzite/ gneissmetalforR.C.C.work in foundationslikeraft,stripfoundations, grillageandfootingsofR.C.C.columns and steel stanchionsetc. including bailing outwater,formwork,coverblocks compactionandcuringrougheningthe surfaceifspecialfinishistobeprovided (Excludingreinforcementandstructural steel)complete,Withfullyautomaticmicro processor based PLC with SCADA enabled reversibledrumtypeconcretemixer. With natural sand. Spec.No.:Bd.F.3PageNo.298andB.7, Page No.38 |
| 125 | Providingandcastinginsitucement concreteM-20 oftrap/granite/quartzite/ gneissmetal forR.C.C.columns asper detailed designs and drawing or as directed includingcentering,formwork,coverblocks compactingandrougheningthesurfaceif specialfinishistobeprovidedandcuring complete.(Excludingreinforcement).With fullyautomaticmicroprocessorbasedPLC withSCADA enabledreversibledrumtype concrete mixer. With natural sand. Spec.No.:Bd.F.5PageNo.300andB.7, Page.No. 38 |
| 126 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) |
| 127 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/ quartzite/ gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessorbasedPLCwithSCADAenabledreversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 128 | Providing and laying Cast in situ/Ready Mixcement concrete M-20 of trap/ granite/ quartzite/ gneiss metal forR.C.C.chajjaasperdetaileddesignanddrawingsincludingsteelcentering,formwork,coverblocks, laying/pumping,compactingand rougheningthesurfaceif specialfinishistobeprovidedandcuring complete. (Excluding reinforcement and structural steel). withfullyautomaticmicroprocessorbasedPLC with SCADAenabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade) |
| 129 | Filling in plinth and floors with approved excavatedmaterials in15cmto20cm layersincludingwateringandcompaction complete.Spec. No.: Bd.A.10 Page No. 262 |
| 130 | Fillinginplinthandfloorswith contractors soil sand or murum in 15 cm to20cm,layersincludingwateringand compaction complete.Spec. No.: Bd.A.11 Page No. 263 |
| 131 | Providingdry/trap/ granite/quartzite/ gneissrubblestonesoling 15cmto20 cmthickincludinghandpackingand compacting complete. Spec. No.: Bd.A. 12 Page No. 264 |
| 132 | Providingandcastingin situcementconcreteinM-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sillof doors and windows moulded as per detailed drawings or chamfered as approved by the Engineerincluding centering, formwork,cover blocks compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement).withConcrete concretemixerWith ------ sand. Spec. No.: Bd. F. 12 Page No. 304 & B-7, Pg 38 |
| 133 | Providing and fixing in position TMT - FE - 500Metric bar reinforcement ofvarious diameters for Tonne R.C.C.pile caps, footings,foundations, slabs, beams columns, canopies, staircase,newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending,hooking the bars, binding withwires or tackwelding and supporting as required complete.Spec. No.: Bd.F.17, Page No. 306 (Page No. 52, I.No.8/5 BDE 17) |
| 134 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6 insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete |
| 135 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop ironstrips25mm X1.6mm placed ateverythirdcourse,properlybentandbondedatendsscaffolding, racking out joints and watering etc. complete. |
| 136 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mmthickincementmortar1:4using waterproofingcompoundat1kgper cementbagcuringthesamefornotless than 2 days and keeping the surface of the basecoatroughtoreceivethesandfaced treatment 6 to 8 mm thick in cement mortar 1:4finishingthesurfacebytakingout grainsandcuringforfourteendays scaffolding etc.complete. Spec. No.: Bd.L.7 Page No. 369 |
| 137 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:4without neerufinish,to concrete,bricksurface,inallpositionsincludingscaffoldingandcuring etc.complete. |
| 138 | Providing and laying vitrified mirror / glossy finish tiles decorative typehaving size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness andconfirming to IS. 15622-2006( groupBla) of approved make, shade and pattern for flooring in required position laid on a bed of1:4cementmortarincludingneat cementfloat,fillingjoints,curingandclearing etc. complete. |
| 139 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and patternfordadoandskirting inrequiredpositionfixedin1:4cementmortarincludingneatcementfloat, filling joints, curing and clearingetc. complete |
| 140 | Providing and fixing steel frame of angle 50 x 50 x 6 mm size for window with 16 mm with mild steel bars horizontally at 10 cm c/c for ventilator portion and at 15 cm c/c for remaining portion with M.S. flat of size 40 x 6 mm vertical at center including iron hold fast boxes for fixing40x6mmverticalatcenterincluding iron hold fastboxesforfixing40 x 6 mm verticalat centerincluding ironholdfastboxes forfixing shutters including welding finishing painting etc. complete. |
| 141 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldingsandlipping,wroughtironholdfasts,chromiumplated fixtures and fastenings, with brass mortiselock,chromiumplatedhandlesonboth sides, and finishing with French Polish etc. complete. |
| 142 | Providing andfixing mild steelgrill workfor windows,ventilators etc.20 Kilogram/Square Metre as per drawing including fixtures,necessarywelding andpainting withone coatsof anticorrosive paint and twocoats of oil painting complete. |
| 143 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / OceanBrown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing,etc. complete. |
| 144 | Providing andfixing inposition.(asperI.S.1868/ 1982)Aluminium sliding window oftwo tracks with rectangularpipe having overalldimension63.50x38.10x1.02mm atweight 0.547 Kilogram/Running metre. and window frame bottom track section 61.85 x 31.75 x 1.20 mm atweight 0.695Kilogram/Running metre.Topandside track section61.85x31.75x 1.30 mm at weight 0.659 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. And handle section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Runningmetre.As per detailed drawings and as directed by Engineer in chargewithallnecessaryAluminiumsections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section ofshutterincluding 5mm thickplainglasswithallrequiredscrewsandnutsetc,complete.Withpowder coating with box |
| 145 | ProvidingandfixingOrissatypewhiteglazedearthenware575mmwaterclosetpan including S trap withearthenware footrests,castironsoilandventpipe uptooutside face ofthe wall 1:2:4brick batlimeconcrete bedding without flushing tank and its accessories etc. complete. |
| 146 | Providing and laying Antiskid Ceramic tiles of approved qualityof size 30 cm x 30 cm and confirming to IS 15622-2006(Group-BIIA)forantiskidflooringinrequiredpositionlaidonabedof1:4cementmortar including cement float, filling joint with cement slurry cleaning curing etc. complete. |
| 147 | Providing and laying ceramic tileshaving size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
| 148 | Providingandfixingfiberglassreinforcedpolysterdoorshutter30mmthickasperIS14856(2000) (Reaffirmed2006)withoutventilatorincluding chromiumplatedfixturesandfasteningwith chromium plated handles on both sides, etc. complete |
| 149 | Providing andfixing in position powder coated aluminium louvered windows / ventilator of varioussizes withpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38 mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete. |
| 150 | ProvidingandfixingwhiteglazedearthenwareWashHandBasinof55cm.x40cm.size including coldwaterpillartap/coldandhotwaterpillartapbrackets,rubberplugsandbrasschain,stoptapand necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Makinggood the damaged surface, testing etc. complete. |
| 151 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 152 | Providingandfixing15mm dia.screwdownbib/stoptapofbrassincluding necessarysocketunionnut complete. |
| 153 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and builtcorrugatedinclusiveofdeliveryuptodestinationhoistingand fixing of accessories such as inlet,outletoverflowpipeinclusiveofalltankscapacity between 200 to 1000 liters |
| 154 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparingthesurfacebythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete. |
| 155 | Providingandapplyingwashableoil-bounddistemperofapproved colourand shadetooldand new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. |
| 156 | Providingandapplyingtwocoatsofwaterproofcementpaintofapprovedmanufactureandofapproved colourtotheplasteredsurfacesincludingscaffoldingifnecessary,cleaningandpreparingthesurface, watering for two days etc.complete. |
| 157 | Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSYPAVING BLOCKSof60millimeterthicknessofhavingastrengthof400Kilogram/sq.mofapprovedqualityand shapeonabedofcrushedsandof25to30millimeterthickincludingstrikingjointsandcleaning etc. complete. (using 100% crushed sand) |
| 158 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laidinrequiredslopetodrainthewaterforanyspanaftercleaningthebasesurface.Applyingacoatof cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layerfor3days,applyingcementslurryoverthislayerjointsofbrickbatswithC.M.1:3admixedwith approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed withapprovedwaterproofingcompound.Markingfinishedsurfacewithfalse squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for requiredheight,withdripmouldat thejunctionofplasterandparapetandcuringand covering10yearsGuaranteeagainstleakproofness onCourtfeestamppaperofRs.500/- including ponding test etc. complete. |
| 159 | ProvidingandfixingP.V.C.Rainwaterpipesof110mmouterdiameterandhavingwall thicknessof 2.2to2.7mmconfirmingtoI.S.13592-1992includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket withsolventcementandproperlyrestingtheshoeofpipesonC.C.or masonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings andadditional 2 piece socket clips shall be got approvedfrom engineer in charge etc. complete. |
| 160 | Royalty Charges |
| 161 | Quality Control Charges- CEMENT. - i) Compressive Strength. ii) Initial Setting Time. iii) Final setting Time. iv) Specific Gravity. v) Soundness.vi)Fineness vii)Workability. |
| 162 | BRICK.- i) Compressive Strength. ii) Water absorption. |
| 163 | Footing, Column, Beam -Compressive Strength OF C.C. Cube(Set of 3 cubes). |
| 164 | STEELi) Ultimate Tensile Stress. ii) Percentage Elongation iii) (Yeild Stress) Proof Stress. iv) Weight per meter. |
| 165 | Construction of Glass House with Fogger Unit at Strawberry Research Station under RKVY Project at Mahabaleswhar, Dist. Satara.Removinggrass,gazergrassand disposingoffoutofbuildingpremisesincludingmaking clean the ground by shovel and phavaras etc. complete. |
| 166 | Hiring 76 HP JCB machine on Machine Hrs. Basis for preparation of formation of play ground including cutting thorny bushesh, removing big boulders & conveying, dozing, Levelling as directed by Engineer in charge including Diesel, Operator, transportation including all machinery, labour and taxes etc. complete. |
| 167 | Excavationforfoundationinearth,soil ofalltypes,sand,gravelandsoft murum,includingremovingtheexcavated material upto adistanceof50m.beyond the building area & stacking and spreading asdirected,dewatering,preparingthebed forthefoundationandnecessaryback filling,ramming,wateringincludingshoring andstruttingetc.complete. (Liftupto1.5 m.)By Manual Means Spec. No.: Bd.A.1 Page No. 259 |
| 168 | ExcavationforfoundationinHard murumandbouldersincludingremoving the excavated materials upto a distance 50 metres,beyondthebuildingareaand stackingandspreadingasdirected dewateringpreparingthebedforthe oundationandnecessarybackfilling, ramming,wateringincludingshoringand strutting etc. complete. (Lift upto 1.5m.)By Manual Means Spec. No.: Bd.A.3 Page No. 259 |
| 169 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering,preparingthebedforthefoundationandnecessarybackfillingwithavailableearth/murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m)By Mechanical Means |
| 170 | Providingandlayinginsitu, cementconcretein M-10 oftrap/granite/quartzite/gneissmetalfor foundationand bedding includingbailingout water, formwork, compacting and curing complete, withfullyautomaticmicroprocessorbasedPLC with SCADA enabled reversible Drum Type mixer, with natural sand. Spec. No.: Bd. E. 1 Page No. 287 |
| 171 | Providingandlayinginsitu cement concreteM-20of trap /granite/quartzite/ gneissmetalforR.C.C.work in foundationslikeraft,stripfoundations, grillageandfootingsofR.C.C.columns and steel stanchionsetc. including bailing outwater,formwork,coverblocks compactionandcuringrougheningthe surfaceifspecialfinishistobeprovided (Excludingreinforcementandstructural steel)complete,Withfullyautomaticmicro processor based PLC with SCADA enabled reversibledrumtypeconcretemixer. With natural sand. Spec.No.:Bd.F.3PageNo.298andB.7, Page No.38 |
| 172 | Providingandcastinginsitucement concreteM-20 oftrap/granite/quartzite/ gneissmetal forR.C.C.columns asper detailed designs and drawing or as directed includingcentering,formwork,coverblocks compactingandrougheningthesurfaceif specialfinishistobeprovidedandcuring complete.(Excludingreinforcement).With fullyautomaticmicroprocessorbasedPLC withSCADA enabledreversibledrumtype concrete mixer. With natural sand. Spec.No.:Bd.F.5PageNo.300andB.7, Page.No. 38 |
| 173 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteM-20oftrap/granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or asdirected including steel centering, formwork, cover blocks, laying/pumping,compactionand roughening thesurfaceifspecialfinishistobeprovidedand curingetc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushedsand VSI Grade) |
| 174 | Filling in plinth and floors with approved excavatedmaterials in15cmto20cm layersincludingwateringandcompaction complete.Spec. No.: Bd.A.10 Page No. 262 |
| 175 | Fillinginplinthandfloorswith contractors soil sand or murum in 15 cm to20cm,layersincludingwateringand compaction complete.Spec. No.: Bd.A.11 Page No. 263 |
| 176 | Providingdry/trap/ granite/quartzite/ gneissrubblestonesoling 15cmto20 cmthickincludinghandpackingand compacting complete. Spec. No.: Bd.A. 12 Page No. 264 |
| 177 | Providingandcastingin situcementconcreteinM-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C.coping to plinth or parapet and sillof doors and windows moulded as per detailed drawings or chamfered as approved by the Engineerincluding centering, formwork,cover blocks compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement).withConcrete concretemixerWith ------ sand. Spec. No.: Bd. F. 12 Page No. 304 & B-7, Pg 38 |
| 178 | Providing and fixing in position TMT - FE - 500Metric bar reinforcement ofvarious diameters for Tonne R.C.C.pile caps, footings,foundations, slabs, beams columns, canopies, staircase,newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules including cutting, bending,hooking the bars, binding withwires or tackwelding and supporting as required complete.Spec. No.: Bd.F.17, Page No. 306 (Page No. 52, I.No.8/5 BDE 17) |
| 179 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar 1:6 infoundationsandplinthofinnerwalls/inplinthexternalwallsincludingbailingoutwatermanually, striking joints on unexposedfaces, raking out joints on exposedfaces and watering etc. Complete. |
| 180 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6 insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. Complete |
| 181 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15mmthickincementmortar1:4using waterproofingcompoundat1kgper cementbagcuringthesamefornotless than 2 days and keeping the surface of the basecoatroughtoreceivethesandfaced treatment 6 to 8 mm thick in cement mortar 1:4finishingthesurfacebytakingout grainsandcuringforfourteendays scaffolding etc.complete. Spec. No.: Bd.L.7 Page No. 369 |
| 182 | Providing internal cement plaster 20mm thick inSingle coats in cement mortar 1:4without neerufinish,to concrete,bricksurface,inallpositionsincludingscaffoldingandcuring etc.complete. |
| 183 | Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick andrequired widthinplain/diamondpatternonbed of1:6 C.M.including cementfloat, filling joints withneat cement slurry, curing, polishing and cleaningetc. complete. |
| 184 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing,gusset platesetc.asperdetaileddesignsanddrawingsorasdirectedincluding cutting,fabricating,hoisting, erecting fixing in position, Making riveted/ bolted/ weldedconnection and onecoatofanticorrosive paint andover it 2 coats of oil painting approved quality and shade etc. complete. |
| 185 | Providing and fixing sheet glass of 24 oz. for all size including putty etc. complete |
| 186 | Providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600 mm x 450mm sizeasperdetailed drawingincludingverticalboth sidepolished kadappahstone25to30mmthick supportswithkadappah top35to 40mm thickandpolishedgranite 16to 20mm topwithside stripsof granite at front and both sides of platform raised with two verticalgranitesupports15cmheightandtop graniteof75x40cmincludingcutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) |
| 187 | ProvidingandfixingM.S.grilldoor24Kilogram/SquareMetreofvarioussizeasperdetaileddrawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc |
| 188 | Providing and erecting chain link fencing 1.6 M. height withG.I. chainlink of size 50 x 50 mm, 8 gauge thickandfixed75mmabovegroundlevelonverticalM.S.Anglesof40x40x6mmsize,includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top andbottom of 25 x 25 x 5 mm size andvertical M.S. flat 35 x 5 mm and25 x 5mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. |
| 189 | Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc.complete.(weight18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.Number: As directed by Engineer- in-charge. |
| 190 | Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated withkynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats,weather silicon sealent,backer rods etc .overall weight of the ACP shall not be less than 7.5 Kilogram/Square Metre) |
| 191 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 192 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 193 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and builtcorrugatedinclusiveofdeliveryuptodestinationhoistingand fixing of accessories such as inlet,outletoverflowpipeinclusiveofalltankscapacity between 200 to 1000 liters |
| 194 | Providing andconstructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raftinB.C.soil area includingcost of reinforcement, 1:2:4 cement concretechannels halfroundG.S.W.pipes,Brick Masonry,plasteringfrominsideandairtight75mmthickR.C.C.covermediumduty100Kilogrametc. complete. |
| 195 | Providing, laying and fixing P.V.C. pipe of 110mm .dia .with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipeline if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 196 | Add for Royalty Charges |
| 197 | Quality Control Charges- STEELi) Ultimate Tensile Stress. ii) Percentage Elongation iii) (Yeild Stress) Proof Stress. iv) Weight per meter. |
| 198 | BRICK.- i) Compressive Strength. ii) Water absorption. |
| 199 | CEMENT. - i) Compressive Strength. ii) Initial Setting Time. iii) Final setting Time. iv) Specific Gravity. v) Soundness. vi)Fineness vii)Workability. |
| 200 | Footing, Column, Beam -Compressive Strength OF C.C. Cube(Set of 3 cubes). |
AI Tender Summary
Tender Timeline
Jul 17, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedAug 10, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender