| 1 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : Of area of 3 sqm. and belowand Of area beyond 3 sqm |
| 2 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 4 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead 14.1.1 With cement mortar 1:4 (1 cement : 4 fine sand) |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 6 | Brick work with F.P.S. bricks ofclass designation 75 in super structure in:1cement : 6 coarse sand mortar |
| 7 | 15mm thick cement plaster of 1 cement: 6 fine sand mix. |
| 8 | Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position :2nd class kail wood |
| 9 | Providing and fixing 12 mm thick flat pressed 3 layer medium density particle board or graded particle board (Grade I) IS: 3087 marked, in ceiling with necessary nails etc. complete (frame work to be paid separately) : |
| 10 | Wooden planking, tongued and grooved in flooring including fixing with iron screws complete: 18 mm thick second class Deodar wood |
| 11 | Providing and fixing decorative high pressure laminated sheet of plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S including cost of adhesive of approved quality 1.5mm thick |
| 12 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 13 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 14 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats |
| 15 | Polishing on wood work with readymade wax polish of approved brand and manufacture on old work. |
| 16 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture on New work |
| 17 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 18 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Zsections and other sections of approved make conforming to IS: 733 andIS:1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall besmooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portionAnodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 19 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Zsections and other sections of approved make conforming to IS: 733 andIS:1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall besmooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 20 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm) |
| 21 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in charge.side and balancing lamination on other side Pre-laminated particle board with decorative lamination on both sides |
| 22 | Providing and fixing Aluminium beading |
| 23 | Providing and fixing aluminum tubular handle bar 32mm outer dia, 3.0mm thick & 2100mm long with SS screw etc. complete as per direction of Engineer-in-charge. Anodized (AC 15)aluminum tubular handle bar |
| 24 | Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 25 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). 35mm second class kail wood |
| 26 | Providing and fixing decorative high pressure laminated sheet of plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S including cost of adhesive of approved quality 1mm thick |
| 27 | Installation of two number ceiling light 2 ft x 2ftincluding installation ( LMR) |
| 28 | Providing 5 number VIP Chairs (LMR) |
| 29 | Installation one number Split AC including all fitings and installation (LMR) |
| 30 | Carriage of construction material: Sand |
| 31 | Carriage of construction material:Agg |
| 32 | Carriage of construction material: Bricks |