Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments For Water Supply Scheme Wani Mohalla Balhama, srinagar-Jammu And Kashmir

Public Health Engineering Department-PHED has published Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments For Water Supply Scheme Wani Mohalla Balhama. Submission Date for this Tender is 10-08-2023. Water Supply Project Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38662205
Corrigendum : Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments For Water Supply Scheme Wani Mohalla Balhama
Open Tender
Indian
Jammu And Kashmir
srinagar
10-08-2023

Tender Details

Tender For Supply, Installation, Testing And Commissioning Of Electro-Mechanical Equipments For Water Supply Scheme Wani Mohalla Balhama-0 1 Supply, Installation, Testing & Commissioning Of Submersible Pumping Unit As Per Is 8034 With Following Specification Are As Under:Pump:Efficiency=Not Less Than 50%Speed=2900 Rpmtype Of Pump = Mixed Flow. Type Of Fluid To Be Handled= Clear Water Discharge:4000Gphhead:70M ( Rest Technical Specifications As Per Annexure A ) 2 Fabrication, Providing, Fitting And Lowering Of B Class G.I Column Pipe 80Mm Nb Conforming To Is: 1239 Of Length 10 Rft Into The 250 Mm Casing Dia. Production Well Up To The Desired Depth. The Job Includes Providing And Welding Of Flanges Conforming To Is: 6392, Table-17 And Pn 16 To These Pipes And Welding Of Flanges In Two Layers To Make The Flanged Joint Strong And Leak Proof. The Pipe Of 10 Ft Length Is To Be Welding On Both Sides With Flanges Using Welding Rod Of Reputed Make. The Job Includes All Types Of Skilled Labours, Arrangement Of Power Supply / Diesel Generator Set Etc Required For The Job Including P / F Of Suitable Size Nuts, Bolts And R.I Gasket In The Flanged Joints Of Column Pipes. The Job Further Includes Cutting Of 2 No. Rectangular Cable Slots In Each Flange. 3 Fabrication, Providing And Fitting Of Split Type Ms Clamps 10 Mm Thick, 2 Ft Long And 65Mm Wide For Lowering And Holding Of Pumping Unit Fitted. The Job Includes The Cost Of Required Size Of Nuts And Bolts. 4 Fabrication, Providing And Fitting Of 80Mm, 90–120-Degree Bend / Elbow To Be Fabricated Out Of Class B And C G.I Pipe, ( 1 M ) Length And Flanged On Both Ends A To Make It Leak Proof. The Flanges Shall Be M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) And Welded On Both Sides. The Job Includes Nuts, Bolts, Gaskets Etc As Per Site Requirement. 5 Fabrication, Providing And Fitting Of Washout Tee With Arm Length 1.2 Feet Each. The Tee Shall Be Fabricated Out Of G.I C-Class Pipe With M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends. The Size Of The Tee & Dia. Of Pipe: 80Mm 6 Providing And Fitting Of Ductile Iron Double Flanged, Slanted Seat Swing Check Valve ( Nrv ) 80Mm As Per Is 5312. The Body Shall Be Of Ductile Cast Iron With Fully Encapsulated Vulcanized Epdm Rubber ( Approved For Drinking Water ) .The Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions.It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.S Flanges Perfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fitted With Rising Main Of The Pumping Unit At Appropriate Spots As Per Site Requirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required Forthe Job. Preferably Makes : Vag / Sigma Flow 7 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seated Glandless Gate / Sluice Valves 80Mm As Per Is14846 For Regulating The Water Supply Outside The Pumping Units. The Body And Bonnet Of The Valve Shall Be Of Ductile Iron, Wedge With Fully Vulcanized Epdm Rubber ( Approved For Drinking Water ) And Nbr Seal. The Gate / Sluice Valve Shall Be Compatible For Buried Applications And Shall Be Safe To Install In Both Horizontal And Vertical Positions It Shall Have Electrostatic Epoxy Coating ( Approved For Drinking Water ) Both Inside And Outside Of The Valve. The Valve Shall Be Supplied Along With Hand Wheel.Cost On Account Of Nuts, Bolts, Gaskets, Etc Required For The Job Is Included In The Scope Of Work. The Job Includes Providing And Fitting Of 02 Nos.M.S Flanges Perfectly Adaptable To The Inbuilt Flanges Of The Valve Which Shall Be Fitted With Rising Main Of The Pumping Unit At Appropriate Spots As Per Site Requirement.The Job Includes The Cost On Account Of P / F Of Nuts, Bolts And Gasket Required For The Job.Preferably Makes : Vag / Sigma Flow 8 Fabrication Of Gantry Mechanism By Way Of Providing Of Structural Steel In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Primer Coat Of Approved Steel Primer All Completely Welded. The Job Also Includes Painting Of Complete Structure In One Coat Of Red Oxide And 02 Coats Of Enamel Metal Paint. Vertical Posts=Ismc 200 No. Of Vertical Posts=02 Nos. Vertical Channel Section Each Post =02 Nos ( Seam Welded Face To Face ) . Vertical Post Bracing=Ismc 100 Sole / Matching Plates=500X300x12 Thick Height Of Vertical Posts=5 M Size Of Vertical Post Concrete Blocks=600X600x900 Mm ( Depth ) Concrete Grade=M20 Welding Electrode= Over Cord Ss Of Adore / Esab / L&T / Advani Monorail Section=Ishb 250 Length Of Monorail=5M Steel Detail :Ismc 200I 5Mx2x2=20 M @ 22.3Kg / M = 446 Kgiiismc100 ( 0.25Mx8x2x2 ) =8 M@ 9.2Kg / M=73.60Kgiiiplate 0.500X0.300X8 ( 12Mm ) =1.20 M² ( 12Thk ) = 112.80 Kgivmonorail 5 M @ 51.4 Kg / M Ishb250=257Kgsv Bolts / Nuts ( L.S ) =30Kgstotal=919.4 Kgsay 920 Kg. 9 Supply, Installation And Testing Of Motorized Chain Hoist With Hook Suspension Along With Travelling Trolley Of Proper Specifications ( Rest Technical Specifications As Per Annexure A ) 10 Tool Kit For Maintenance: The Tool Kit For Maintenance Shall Comprise Of The Following Items: I. Double Ended Spanner ( Chrome Plated ) Of All Sizes ( 01 Set Complete ) Ii. Double Ended Ring Spanners ( Chrome Plated ) Of All Sizes ( 01 Set Complete ) Iii. Allen Key Set Black Finish Of All Sizes ( 01 Set Complete ) Iv. Combination Pliers Insulated With Thick C.A Sleeve; Size In Mm 165, 210, 255 ( 01 No Each ) V. Long Nose Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 ( 01 No Each ) Vi. Side Cutting Plier Insulated With Thick C.A Sleeve; Size In Mm 165, 205 ( 01 No Each ) Vii. Insulated Screw Drivers ( Different Size ) – ( 06 Nos ) Viii. Hammer With Handle Weight – 110 Gm, 340 Gm, And 600 Gm ( 01 No Each ) Ix. Heavy Duty Pipe Wrench Length In Mm - 200, 300, 600 ( 01 No Each ) X.Electric Multimeter =1No Xi. Digital Multimeter – 1No. Xii. Digital Clamp Tester Capable To Measure Up To 400A - 1 No. Xiii. Hack Saw Frame With Hack Saw Blade – 01 No. Xiv. S-16 Mxl, S- 16 H X L Socket Set ( 19 Sockets + 6 Accessories ) – ( 01 No Each ) 11 Gravel Hooperproviding, Fabricating And Fitting Of Gravel Hooper Fabricated Out Of Angle Iron Isa ( 50*50*5 ) And Ms Plates, Chequered Plate 8Mm Sheeting All Over On All Five Sides Including Cover At Top And Excluding Bottom Side; Of Size 3’ X 3’ From Top And 2’ X 2’ At Bottom Having 3’ Depth ( Frustum Type ) . The Top Cover Is To Be Split In To Two Parts With Making / Cutting Of Circular Hole Having Overall Diameter Of 12 Inch And Hinged With The Two Sides Of The Hooper By Way Of P / F Of Required Size Of Moveable Hinges With Locking Arrangement At The Top Of The Hooper. The Job Includes Earth Work Excavation From The Top Of The Well Casing / Flooring Up To The Ground Level For Making Of Gravel Pit To Accommodate Gravel Hooper. The Job Includes All Head Loads And Lifts. 12 Fabrication, Providing And Fitting Of Modular Motor Control Panel Of Appropriate Size Fabricated Out Of 14 Swg Sheet Having Required Openings / Vents And Protection Class: Ip-55 & Fitted ( Rest Technical Specifications As Per Annexure A ) 13 Providing, Fitting, Testing And Commissioning Of 40Kva Voltage Stabilizer ( Rest Technical Specifications As Per Annexure A ) 14 Providing And Fitting Of 3.5 Core 70 Sq Mm, Xlpe 1.1 Kv And 11 Kv Grade Armored Aluminium Cable Conforming To Latest Is Code 1St As Service Line From The Ht Transformer To Mccb And Then From Mccb To Control Panel Including Necessary Thimbling, Crimping, Taping Etc. The Job Also Includes P / F Of Aluminium Thimbles, Lugs Of Various Sizes As Per Size Requirement Including Crimping And Taping. 15 Providing And Fitting Of 10 Sq.Mm 3-Core Flat Submersible Copper Cable Conforming To Is: 694 ( Part 1St ) – 1964 & Is: 694 ( Part 2Nd ) - 1964 For Submersible Pumping Unit And Other Electrical Equipment. The Cable Connection Terminals Shall Be Fitted With Copper Thimbles Of Required Size. 16 P / I Of Earthing Station For Electric Substation, Lt Panel And Stabilizer Comprising Of Company Fabricated Earthing Electrode As Per Is: 3043. The Job Includes Auguring Of Bore Of Required Dia / Depth For Installation Of Electrode Along With Backfill Compound Mixed With Soil And All Other Items Required Thereof For Achieving The Best Result. The Job Includes Connecting Of Electric Gadgets Through Gi Strip As Per Relevant Standards.Safe Earthing Electrode Size : 80 Mm Dia Length : 2000 Mm Back Fill Compound : 30 Kg 17 Providing, Laying And Connection Of 2Cx16 Mm² Flat, Pvc Sheathed Copper, Armoured Cable For Connecting Of High Mast Pole To The Stabilizer As Per Latest Relevant Is Code. The Job Includes Underground Laying Or Overcharging As Per Requirement And Directions Of Site Incharge. 18 Supply, Installation, Testing & Commissioning Of 950Va Full Sine Wave Power Inverter Including Providing / Installation Of 12V, 180Ah Automotive Battery With Trolley And Cover. With 2-Core 4 Mm2 Cu ( 25 M ) Wiring As Per Site Requirement Along Withotheraccessorieslikess-Combine ( 02 No’S ) , 3-Pin Plugs Etc Of Reputed Make For Proper Fitment And Installation Of The Item. 19 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro- Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen Due To Possible Leakage Of Current & Short Circuit. The Floor Surface Shall Be Made Good & Shall Be Free From Dust, Grease, Foreign Material & Moisture Free. The Mats Shall Be As Per Is 15652:2006 & Shall Have The Following Specifications: Composition: Rubber ( Synthetic Mats For Electrical Purpose ) Thickness: - 2.5Mm Size: - 1M Wide. The Rubber Mats Shall Be Accepted With Manufacturers Test Certificate. 20 Supply, Installation, Commissioning And Creation Of Pole Mounted, Outdoor Type 63Kva Capacity ( Level-2 ) Electric Sub Station ( Rest Technical Specifications As Per Annexure A ) 21 Providing And Fitting Of 9 Ft. Long Ismc ( 100X50x5 ) Channel Including Clamps ( As Per Site Requirement ) ( 2 No. ) 22 Providing And Fitting Of 9 Ft. Long Ismc ( 75X40x4.8 ) Channel Including Clamps ( As Per Site Requirement ) ( 7 No. ) 23 Supply, Installation, Testing And Commissioning Of Polymeric Gang Operated Air Break Switch, Outdoor Type, Triple Pole, Suitable For Vertical Installation, Single Break Provided With Locking Arrangement At Both On And Off Position Consisting Ofht Post Double Insulator, Copper Or Copper Alloy High Pressure Heavy Contact Assembly, Rod With Bearings , Operating Handle And 2 Length Of 32Mm Dia. Gi Pipe Conforming To Is 1818 1961, 06 No. Of Insulators, Rated Voltage 11Kv 200A Complete As Per Is Specs. 24 Supply, Installation, Testing And Commissioning Of 11Kv Polymer Fuses Set Horn Gap 3-Phase 200 A Suitable For Vertical Installation. 25 Supply, Installation, Testing And Commissioning Of Gapless Surge Arrestor Station Class, 10Ka, 9Kv, La With Polymer Housing, Station Type 26 Supply, Installation, Erection Of 9 Mtrs Long H.T Pole Of Specifications St- 410 ( Sp-33 ) . The Job Further Includes Drilling Of Holes For Installation Of Various Accessories Wherever Required The Job Further Includes G.I Wire Earthing Of Pole As Per Rec Standard. 27 P / F Of Galvanized Nuts, Bolts Of Various Sizes As Per Site Requirement. 28 P / F Danger Plate With Clamps 29 Providing And Fitting Of Pg Clamps 30 Providing And Fitting Of Galvanized Stay Set With 50 X 8 Mm Stay Clamp, Guy Insulator ( 2No. ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts , 2 N0- Turn Buckle , 1.8 M Long , 16 Mm Diameter Solid G.I Stay Rod & 7 / 3.15 Mm Dia. G.I Stranded Wire Complete. 31 Painting Of Poles With Red Oxide 32 Painting Of Poles With Aluminum Paint 33 Providing And Fitting Of Acsr As Per Is 398 ( Part-2 ) 1996 For 50 Sq.Mmacsr ( Galvanised Steel Reinforced ) For Fitment Of Various Accessories. 34 Supply, Installation, Testing Of 35 Sq Mm Xlpe Ht Cable ( Abc Type ) Of 11 Kv Grade With Following Specifications Size Cross Sectional Area In Square Mm ) =3X35 Phases Red, Yellow , Blue 35 P / F Of 11 Kv Cable Termination Kit For Connecting 35 Sq Mm Xlpe Cable ( Abc Type ) With The Existing Ht Line Near Tapping Point And Ht Transformer. 36 P / F Of The Arrangement ( Belt ) To Hold The Transformer Firmly And Securely To The Sub- Station. It Is To Be Fabricated Out Of Isa ( 40X40x5 ) Mm C / W Nuts And Bolts. 37 S / I / T / C Of Three Phase Lt Prodigy Meter On The Service Line At The Sub-Station ( Rest Technical Specifications As Per Annexure A ) 38 Providing Of Good Quality Bedding For Night Stay / Shift Consisting Of: -I ) Mattress With Warm Cover Size 6X3 ( 6Kg ) - 02 No’Sii ) Quilt With Warm Cover Size 5X8 ( 6Kg ) - 02 No’Siii ) Pillows With Covers - 02 No’Siv ) Single Bed Warm Blankets With One Sided Fur- 02 No’Sthe Filling Material For Mattress, Quilt And Pillow Shall Be Of Good Quality Cotton ( White ) . The Job Also Includes Providing Of Pressure Cooker 5Ltr ( 02 No’S ) , Steel Patella ( Utensil ) 5Ltrs ( 02 No’S ) , Cooking Heater ( 01 No. ) , Room Heater 01 No., Steel Buckets 10 Litre Capacity ( 01 No. ) , Plastic Bucket 10 Litre Capacity With Mug 0 ( 2 No’S ) Each, Steel Glasses ( 06 No’S ) , Steel Plates With Large Spoons And Bowls 03 No’S Each, Cup And Saucer Set ( 01 No. Set ) And, 5Kg Gas Cylinder With Burner / Stove. The Job Also Includes Providing Of Thermo- Cool 15’X12’ Along With Excel Matting Of 15’X12’ Size. The Job Also Includes Providing Of Unbreakable Plastic Chair Table Set Consisting Of Chairs 04 No’S, Extra Heavy Table 01 No. The Job Also Includes Providing Of Good Quality Safety Door Locks ( 03 No’S ) Of Reputed Make 39 Fabrication Of ( 6 X 6 ) Ft.Angle Iron Bed ( 02 Nos. ) By Way Of Providing And Fitting Of Structural Steel In Built Up Sections And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Welded 40 Supply, Installation Of 6 Kg Co2 Type Fire Extinguisher Manufactured As Per Is: 15683 Of 2006 With Is Mark And Comply With Dgms ( Approval ) . The Co2 Extinguisher Should Be Suitable For Class B & C Type Fire And Also For Fire Involving Electrical Equipment. The Cylinder Used For Fire Extinguisher Shall Be Approved By Petroleum And Explosive Safety Organization ( Peso ) As Per Gas Cylinder Rules 2004 And As Per Is: 7285 Of 2004. The Body Should Be Made Of Seamless Steel ( Manganese ) Confirming To Is: 7285 With Is Mark And Should Be Provided With Squeeze Grip Nozzle And Should Be Filled With Co2 Confirming To Is: 15222 Of 2002 With Certificate.The Extinguisher Shall Be Provided With Manufactures Test Certificate And Hydraulic Test Certificate By Bis From Peso. 41 Providing And Fitting Of Mccb Under Following Specifications:Type:Dn2-250Dthermal Release Range: 100-250Abreaking Capacity At 415V, 50 Hz : 36 Kano. Of Poles: 04The Mccb Has To Fitted Between Ht Transformer And Control Panel Near Ht Transformer By Fixtures As Per Site Requirement.The Mccb Should Be Housed In Metallic Enclosure For Preventing Moisture 42 Supply And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole ( Single Section ) With Bottom 200Mm, Top 90Mm Wide, Thickness 3Mm With 70 Microns Zinc Coating With Inside Arrangement For Providing Of Power Connection With Following Items.2 No Terminal Connector 60 Amp.2 No Mcb Dp 16 Amp. Required Size Lugs Duly Crimped.1 Set ( 4 No. ) Foundation Bolts Of Required Size 7 Length With Nuts.Cement Concreting Of Required Size Not Less Than 2’X2’X4 In Ratio Of 1:2:4.Required Length Of Pvc Copper Flexible Multi Stand Wire 1.5Mm Fitting To Terminal Conductor With The Light.Mounting Clamps For Fixing Of Flood Lights On Opposite Direction Made With Pole Of Ms & Gi Pipe Of Required Size Including Cost Of Nuts & Bolts.Mounting Arrangements For Fixing Of Gear Box Of Flood Lights With Pole.Earthing In Gi Electrode Pvc Pipe Hdpe Of Required Size & Length For Inlet And Out For Cable In Connection Block. 43 Supply, Installation, Testing And Commissioning Of 120 Watt Led ( Street Light Type ) Input; 90-240 V, 50 Hz.Power Factor; >0.9Colour Temperature: 4K – 6.5Kbeam Angle: 120°- 170°Lumens: >12000Operating Temperature:-20° To 60°The Led Shall Have Pressure Die Cast Aluminium Housing With Power Coated Finish And Having Ingress Protection Upto Ip-68.The Led Shall Be Properly Fitted On The Arm Of The Pole And Connected To The Copper Wire As Provided In Item Above And Made Functional. 44 Supply, Laying, Testing & Commissioning Of 2X16 Mm² Xlpe Aluminium Armoured Cable ( Havells Make ) . 45 Supply, Installation Testing & Commissioning Of Dp, 32 Amp. Mcb Of Required Size Enclosed In Steel Enclosure Including Cost Of Lugs, Cable Gland Etc. 46 P / F Of Lighting / Fan Points In 1.5 Mm Sq. Multi Strand Pvc Wire As Conducted To Be Laid / Carried In Pvc Channel / Conduit As Per Site Requirement. The Job Includes Providing And Fitting Of 5 Amp. Switch, Angle Holders To Be Fitted With 9 Watt Led Lamps Inside The Pump House. 47 P / F Of Heating Points In 2.5 Sq.Mm ( Of Any Reputed Make ) Multi Stand Conductor To Be Laid Carried In Pvc Channel / Conduit As Per Site Requirement. The Job Includes Providing And Fitting Of 16 Amp. Switch Socket Combine.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 26-Jul-2023 Corrigendum for Extension Date 03-08-2023
2 03-Aug-2023 Corrigendum-II for Extension Date 10-08-2023

Key Value

Document Fees
INR 200 /-
EMD
INR 58781.0 /-
Tender Value
INR 19.59 Lakhs /-

BOQ Items

Name of Work:S/I/T/C OF ELECTRO-MECHANICAL WORKS FOR WSS WANI MOHALLAH BALHAMA (DISTRICT - SRINAGAR) UNDER JJM
Sl. No. Item Description
1Supply, Installation, Testing & Commissioning of Submersible Pumping Unit as per IS 8034 with following specification are as under: PUMP: Efficiency=Not less than 50% Speed=2900 Rpm Type of pump = Mixed flow. Type of fluid to be handled= Clear Water Discharge:4000GPH Head:70m (Rest Technical Specifications as per Annexure "A")
2Fabrication, providing, fitting and lowering of B Class G.I column pipe 80mm NB conforming to IS: 1239 of length 10 rft into the 250 mm casing dia. production well up to the desired depth. The job includes Providing and welding of flanges conforming to IS: 6392, Table-17 and PN 16 to these pipes and welding of flanges in two layers to make the flanged joint strong and leak proof. The pipe of 10 ft length is to be welding on both sides with flanges using welding rod of reputed make. The job includes all types of skilled labours, arrangement of power supply/ diesel Generator set etc required for the job including P/F of suitable size nuts, bolts and R.I Gasket in the flanged joints of column pipes. The job further includes cutting of 2 no. rectangular cable slots in each flange.
3Fabrication, providing and fitting of split type MS clamps 10 mm thick, 2 ft long and 65mm wide for lowering and holding of pumping unit fitted. The job includes the cost of required size of nuts and bolts.
4Fabrication, Providing and fitting of 80mm, 90–120-degree bend/elbow to be fabricated out of Class B and C G.I pipe, (1 m) length and flanged on both ends a to make it leak proof. The flanges shall be M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) and welded on both sides. The job includes nuts, bolts, gaskets etc as per site requirement.
5Fabrication, providing and fitting of washout Tee with arm length 1.2 feet each. The Tee shall be fabricated out of G.I C-class pipe with M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) fastened with weld joints on three ends. The size of the Tee & Dia. of pipe: 80mm
6Providing and fitting of Ductile Iron double flanged, Slanted seat swing check valve (NRV) 80mm as per IS 5312. The body shall be of ductile cast iron with fully encapsulated vulcanized EPDM rubber (Approved for drinking water).The valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions. It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Preferably makes : VAG /SIGMA FLOW
7Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seated glandless gate/ sluice valves 80mm as per IS14846 for regulating the water supply outside the pumping units. The body and bonnet of the valve shall be of ductile iron, wedge with fully vulcanized EPDM rubber (Approved for drinking water) and NBR seal. The Gate/Sluice valve shall be compatible for buried applications and shall be safe to install in both horizontal and vertical positions It shall have electrostatic epoxy coating (approved for drinking water) both inside and outside of the valve. The valve shall be supplied along with hand wheel. Cost on account of Nuts, bolts, gaskets, etc required for the job is included in the scope of work. The job includes providing and fitting of 02 nos.M.S flanges perfectly adaptable to the inbuilt flanges of the valve which shall be fitted with rising main of the pumping unit at appropriate spots as per site requirement.The job includes the cost on account of P/F of nuts, bolts and gasket required for the job. Preferably makes : VAG /SIGMA FLOW
8Fabrication of gantry mechanism by way of providing of Structural steel in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a primer coat of approved steel primer all completely Welded. The job also includes painting of complete Structure in one coat of red oxide and 02 coats of enamel metal paint. Vertical Posts=ISMC 200 No. of vertical posts=02 Nos. Vertical channel section each post =02 Nos (seam welded face to face). vertical post bracing=ISMC 100 Sole / Matching plates=500x300x12 thick Height of vertical posts=5 M size of vertical post concrete blocks=600x600x900 mm(Depth) Concrete grade=M20 welding Electrode= Over cord SS of Adore/ESAB/L&T/Advani Monorail Section=ISHB 250 length of monorail=5M Steel Detail :ISMC 200 i 5Mx2x2=20 M @ 22.3kg/m = 446 kg iiISMC100 ( 0.25Mx8x2x2) =8 M@ 9.2kg/m=73.60kg iiiPlate 0.500x0.300x8 (12mm)=1.20 M²(12thk) = 112.80 kg ivMonorail 5 M @ 51.4 kg/M ISHB250=257kgs v Bolts/Nuts(L.S)=30kgs Total=919.4 Kgsay 920 Kg.
9Supply, Installation and testing of motorized chain hoist with hook suspension along with travelling trolley of proper specifications(Rest Technical Specifications as per Annexure "A")
10TOOL KIT For Maintenance: The Tool Kit for maintenance shall comprise of the following items: i. Double ended Spanner (Chrome plated) of all sizes (01 set complete) ii. Double ended Ring spanners (Chrome plated) of all sizes (01 set complete) iii. Allen key set black finish of all sizes (01 set complete) iv. Combination Pliers insulated with thick C.A sleeve; size in mm 165, 210, 255 (01 No each) v. Long nose plier insulated with thick C.A sleeve; size in mm 165, 205 (01 No each) vi. Side cutting plier insulated with thick C.A sleeve; size in mm 165, 205 (01 No each) vii. Insulated screw Drivers (different size ) – (06 Nos) viii. Hammer with handle weight – 110 gm, 340 gm, and 600 gm (01 No each) ix. Heavy duty pipe Wrench length in mm - 200, 300, 600 (01 No each) x.Electric Multimeter =1No xi. Digital multimeter – 1No. xii. Digital Clamp tester capable to measure up to 400A - 1 No. xiii. Hack saw frame with hack saw blade – 01 no. xiv. S-16 MXL, S- 16 H X L Socket Set (19 sockets + 6 Accessories) –(01 No each)
11Gravel Hooper Providing, fabricating and fitting of gravel Hooper fabricated out of Angle iron ISA (50*50*5) and MS plates, Chequered plate 8mm sheeting all over on all five sides including cover at top and excluding bottom side; of size 3’ x 3’ from top and 2’ x 2’ at bottom having 3’ depth (frustum type). The top cover is to be split in to two parts with making/ cutting of circular hole having overall diameter of 12 inch and hinged with the two sides of the Hooper by way of P/F of required size of Moveable hinges with locking arrangement at the top of the Hooper. The job includes earth work excavation from the top of the well casing/flooring up to the ground level for making of gravel pit to Accommodate Gravel Hooper. The job includes all head loads and lifts.
12Fabrication, Providing and fitting of Modular motor control panel of appropriate size fabricated out of 14 SWG sheet having required openings/vents and protection Class: IP-55 & fitted (Rest Technical Specifications as per Annexure "A")
13Providing, fitting, testing and commissioning of 40KVA voltage stabilizer (Rest Technical Specifications as per Annexure "A")
14Providing and Fitting of 3.5 core 70 sq mm, XLPE 1.1 KV and 11 KV grade Armored Aluminium cable conforming to latest IS code 1st as service line from the HT transformer to MCCB and then from MCCB to control panel including necessary thimbling, crimping, taping etc. The job also includes P/F of Aluminium thimbles, lugs of various sizes as per size requirement including crimping and taping.
15Providing and fitting of 10 Sq.mm 3-Core flat submersible copper cable conforming to IS: 694 (Part 1st) – 1964 & IS: 694 (Part 2nd) - 1964 for Submersible Pumping Unit and other electrical Equipment. The cable connection terminals shall be fitted with copper thimbles of required size.
16P/I of earthing station for electric substation, LT panel and stabilizer comprising of company fabricated earthing electrode as per IS: 3043. The job includes Auguring of bore of required dia/depth for installation of electrode along with backfill compound mixed with soil and all other items required thereof for achieving the best result. The job includes connecting of electric gadgets through GI strip as per relevant standards. Safe earthing electrode size : 80 mm dia Length : 2000 mm Back fill compound : 30 kg
17Providing, laying and connection of 2CX16 mm² FLAT, PVC sheathed copper, Armoured cable for connecting of high mast pole to the stabilizer as per latest relevant IS code. The job includes underground laying or overcharging as per requirement and directions of site incharge.
18Supply, installation, Testing & commissioning of 950VA Full Sine wave power inverter including Providing / Installation of 12V, 180AH Automotive Battery with trolley and cover. with 2-core 4 mm2 Cu ( 25 m) wiring as per site requirement along withotheraccessorieslikeSS-Combine(02 No’s), 3-pin plugs etc of reputed make for proper fitment and installation of the item.
19Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro- mechanical machinery for safeguarding the life & limb of the workmen due to possible leakage of current & short circuit. The floor surface shall be made good & shall be free from dust, grease, foreign material & moisture free. The mats shall be as per IS 15652:2006 & shall have the following specifications: Composition: Rubber (synthetic mats for electrical purpose) Thickness: - 2.5mm Size: - 1M wide. The rubber mats shall be accepted with manufacturers test certificate.
20Supply, installation, commissioning and creation of pole mounted, outdoor type 63kva capacity (level-2) Electric Sub Station (Rest Technical Specifications as per Annexure "A")
21Providing and fitting of 9 Ft. Long ISMC (100X50X5) Channel including clamps (As per Site Requirement) (2 No.)
22Providing and fitting of 9 Ft. Long ISMC (75X40X4.8) Channel including clamps (As per Site Requirement) (7 No.)
23Supply, Installation, Testing and commissioning of Polymeric Gang operated Air break switch, outdoor type, triple pole, suitable for vertical installation, single break provided with locking arrangement at both ON and OFF position consisting ofHT post double insulator, copper or copper alloy high pressure heavy contact assembly, rod with bearings , operating handle and 2 length of 32mm dia. GI pipe conforming to IS 1818 1961, 06 No. of insulators, rated voltage 11KV 200A complete as per IS specs.
24Supply, Installation, Testing and commissioning of 11KV polymer fuses Set Horn Gap 3-phase 200 A suitable for vertical installation.
25Supply, Installation, Testing and commissioning of Gapless Surge arrestor station class, 10KA, 9KV, LA With polymer housing, Station Type
26Supply, installation, erection of 9 mtrs long H.T pole of specifications ST- 410 (SP-33) . The job further includes drilling of holes for installation of various accessories wherever required the job further includes G.I wire earthing of pole as per REC standard.
27P/F of Galvanized nuts, bolts of various sizes as per site requirement.
28P/F Danger Plate with clamps
29Providing and fitting of PG clamps
30Providing and fitting of Galvanized stay set with 50 X 8 mm Stay Clamp, Guy insulator (2no.), Anchor plate (200X200X6mm), nuts and bolts , 2 N0- turn buckle , 1.8 m long , 16 mm diameter solid G.I stay rod & 7/3.15 mm dia. G.I stranded wire complete.
31Painting of poles with Red oxide
32Painting of poles with Aluminum paint
33Providing and fitting of ACSR as per IS 398 (part-2) 1996 for 50 sq.mmACSR (Galvanised steel reinforced) for fitment of various accessories.
34Supply, installation, testing of 35 sq mm XLPE HT cable (ABC type) of 11 KV Grade with following specifications size cross sectional area in square mm )=3x35 phases Red, Yellow , Blue
35P/F of 11 KV cable termination kit for connecting 35 Sq mm XLPE cable (ABC type) with the existing HT line near tapping point and HT transformer.
36P/F of the arrangement (Belt) to hold the transformer firmly and securely to the Sub- station. It is to be fabricated out of ISA (40X40X5) mm C/W nuts and bolts.
37S/I/T/C of three phase LT prodigy meter on the service line at the Sub-station (Rest Technical Specifications as per Annexure "A")
38Providing of good quality bedding for night stay/Shift consisting of: - i) Mattress with warm cover size 6"x3" (6Kg)- 02 No’s ii) Quilt with warm cover size 5"x8" (6Kg)- 02 No’s iii) Pillows with covers - 02 No’s iv) Single bed warm blankets with one sided Fur- 02 No’s The filling material for mattress, quilt and pillow shall be of good quality cotton (white). The job also includes providing of pressure cooker 5ltr (02 No’s), Steel patella (utensil) 5ltrs (02 No’s), cooking heater (01 No.), room heater 01 No., steel buckets 10 litre capacity (01 No.), Plastic bucket 10 litre capacity with Mug 0(2 No’s) each, steel glasses (06 No’s), steel Plates with large spoons and bowls 03 No’s each, Cup and Saucer set (01 No. Set) and, 5kg Gas cylinder with burner/ stove. The job also includes providing of thermo- cool 15’x12’ along with excel matting of 15’x12’ size. The job also includes providing of unbreakable Plastic Chair table set consisting of chairs 04 No’s, extra heavy Table 01 No. The job also includes providing of good quality safety Door locks (03 No’s) of reputed make
39Fabrication of (6 x 6) ft.angle iron bed (02 Nos.) by way of providing and fitting of Structural steel in built up sections and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete welded
40Supply, installation of 6 kg CO2 type fire extinguisher manufactured as per IS: 15683 of 2006 with IS mark and comply with DGMS (Approval). The CO2 extinguisher should be suitable for class B & C type fire and also for fire involving electrical equipment. The cylinder used for fire extinguisher shall be approved by petroleum and explosive safety organization (PESO) as per gas cylinder rules 2004 and as per IS: 7285 of 2004. The body should be made of seamless steel (manganese) confirming to IS: 7285 with IS mark and should be provided with squeeze grip nozzle and should be filled with co2 confirming to IS: 15222 of 2002 with certificate.The extinguisher shall be provided with manufactures test certificate and hydraulic test certificate by BIS from PESO.
41Providing and fitting of MCCB under following specifications: Type:DN2-250D Thermal Release Range: 100-250A Breaking Capacity at 415V, 50 Hz : 36 KA No. of poles: 04 The MCCB has to Fitted between HT transformer and Control Panel near HT Transformer by fixtures as per site requirement. The MCCB should be housed in Metallic enclosure for preventing moisture
42Supply and erection of 9 Mtr long Hot Dip Galvanized octagonal pole (single Section) with bottom 200mm, top 90mm wide, thickness 3mm with 70 Microns Zinc coating with inside arrangement for providing of power connection with following items. 2 No Terminal Connector 60 Amp. 2 No MCB DP 16 Amp. Required size lugs duly crimped. 1 Set (4 No.) Foundation Bolts of required size 7 length with Nuts. Cement concreting of required size not less than 2’x2’x4 in ratio of 1:2:4. Required length of PVC copper flexible multi stand wire 1.5mm fitting to terminal conductor with the light. Mounting clamps for fixing of flood lights on opposite direction made with pole of MS & GI pipe of required size including cost of Nuts & Bolts. Mounting arrangements for fixing of Gear box of flood lights with pole. Earthing in GI Electrode PVC pipe HDPE of required size & length for inlet and out for cable in connection block.
43Supply, Installation, testing and commissioning of 120 Watt LED (Street Light Type) Input; 90-240 V, 50 Hz. Power factor; >0.9 Colour Temperature: 4K – 6.5K Beam angle: 120°- 170° Lumens: >12000 Operating Temperature:-20° to 60° The LED shall have pressure die cast aluminium housing with power coated finish and having Ingress Protection upto IP-68. The LED shall be properly fitted on the arm of the pole and connected to the copper wire as provided in item above and made functional.
44Supply, laying, testing & commissioning of 2x16 mm² XLPE Aluminium Armoured Cable (Havells make).
45Supply, installation testing & commissioning of DP, 32 Amp. MCB of required size enclosed in steel enclosure including cost of lugs, Cable Gland etc.
46P/F of lighting/fan points in 1.5 mm Sq. multi strand PVC wire as conducted to be laid /carried in PVC channel /conduit as per site requirement. The job includes providing and fitting of 5 Amp. Switch, angle holders to be fitted with 9 watt LED lamps inside the Pump house.
47P/F of heating points in 2.5 sq.mm (of any reputed make) multi stand conductor to be laid carried in PVC channel / conduit as per site requirement. The job includes providing and fitting of 16 Amp. Switch socket combine.