}

Tender For Repair/Maintenance To Lt Network System In The Aor Of Cph Area Under Ge (Utilities) Udhampur., udhampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair/Maintenance To Lt Network System In The Aor Of Cph Area Under Ge (Utilities) Udhampur.. Submission Date for this Tender is 05-08-2023. Electrical Maintenance Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38659040
Corrigendum : Tender For Repair/Maintenance To Lt Network System In The Aor Of Cph Area Under Ge (Utilities) Udhampur.
Open Tender
Indian
Jammu And Kashmir
udhampur
05-08-2023

Tender Details

Tender For Repair / Maintenance To Lt Network System In The Aor Of Cph Area Under Ge ( Utilities ) Udhampur. 1 Laying, Jointing, Fixingor Passing Through Pipe, Trenches Or Duct Frls, Xlpe Insulated Screenedand Pvc Sheathed Armouredelectric Powerl Tcable Heavy Duty With Aluminium Conductor 3.5 Core Nominal Cross Sectional Area 25 Sqmm All As Specified And As Directed. Note : Cable For Srl Item Nos 1 To 1.07 Shall Be Issued Under Sch B. 2 All As Per Serial Item No 1 Here-In-Before But Of Size 35 Sqmm 3.5 Core. 3 All As Per Serial Item No 1Here-In-Before But Of Size 50 Sqmm 3.5 Core. 4 All As Per Serial Item No 1 Here-In-Before But Of Size 70 Sqmm 3.5 Core. 5 All As Per Serial Item No 1 Here-In-Before But Of Size 120 Sqmm 3.5 Core. 6 All As Per Serial Item No 1 Here-In-Before But Of Size 150 Sqmm 3.5 Core. 7 All As Per Serial Item No 1 Here-In-Before But Of Size 240 Sqmm 3.5 Core. 8 All As Per Serial Item No 1 Here-In-Before But Of Size 300 Sqmm 3.5 Core. 9 Excavation In Trenches Not Exceeding 1.5 M Wide And Not Exceeding 1.5 M Deep For Foundations Of Poles / Stays Etc .Not Exc 10 Sqm Area On Plan And Getting Out In Soft / Loose Soil Complete All As Specified And As Directed By Engr-In-Charge. 10 Returning, Filling In Excavated Soil In Trenches Including Spreading, Leveling, Watering And Well Rammingin Layers N. Exc. 25 Cm Thick Complete All As Specified And Directed By Engr-In-Charge. 11 Removing Of Excavted Soil To A Distance N. Exc. 50 Mtr And Deposited Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified And Directed By Engr-In-Charge. 12 Opening, Maintenance And General Servicing Of Servo Voltage Stablizers Of Different Makes ( Rating From 100 Kva To 400 Kva ) Including Removal Of Sludge From Disserstate Coils, Buck Boost Transfromers, Tightening Of All Nut Bolts, Cleaning Of Stablizer Coils, Checking And Servicing Of Servo Mechanism, Gear Synchronising System, Automatice Voltage Regulator Circuits And Other Allied Electrical Components Complete All As Specified And Directed By Engr-In-Charge. Note:- Rate Quoted By Contractor Is Inclusive Of Following Items:- ( A ) Servo Motorwith Rc Net Work Having Torque Of 3 Kg / Cm -1 No ( B ) Servo Motorwith Rc Net Work Having Torque Of 10 Kg / Cm -1 No ( C ) Electronic Control Card For Automatic Voltageregulation - 1 No ( D ) Transformer Oil - 35 Ltr ( E ) Volt Meter 0-500 Capacity -1 No ( F ) Ammeter Ct Operated-1 No ( G ) Circuit Plate 30 Kva - 400 Kva - 1 No ( H ) Pulse Transformer Of Cap 30 Kva - 400 Kva - 1 No ( I ) Rewinding For Copper Coil -25 Kg ( J ) Shifting Of Stablizer From Aor Of Mph To Workshop ( Tro / Fro ) ( K ) Oem Service Engineer Shall Be Engage For Rectification Of Defects ( L ) Minor Items Like Carbon Brush, Push Buttons, Auto / Manual / Micro Press Switch, Indicators Lamps, Voltmeter / Ammeter Selector Switch. ( M ) Contractor Must Provide Replacement Of Suitable Stablizer For Use Until It Get Repaired From Workshop. 13 Decarbonising Of Lt Panel Board / Feeder Pillar Boxes By Ctc ( Carbon Tetra Chloride ) , Removing The Carbon Deposited Inside The Panel, Cleaning The Panel With Cotton Waste, Applying One Coat Of Becktol Red Solution, Checking The Faults Inside The Panel Board And Charging The Lt Panel Post Completion Of Decarbonisation Complete All As Specified And Directed By Engr-In-Charge. Note : ( A ) Proper Shut Down Shall Be Taken Prior The Commencement Of Work . ( B ) Contractor Shall Provide 2 Bottles Of ( 250Ml ) - Ctc . Cotton Waste Of Not Less Than -1Kg And Dr Bectol Solution ( 250Ml ) - 1 No For Performing The Decarbonisation. ( C ) Fabrication Of Lt Panels For Broken Hinges Shall Be Rectified. ( D ) Lt Panel Shall Be Painted Withtwo Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer. ( E ) Marking On Lt Panels Shall Be Done As Per Sources Of Power Supply ( 1100 Volts ) And Outgoing Area By 10Cm Glow Sign / Paint All As Directions Of Engr-In-Charge. 14 Supply And Laying And Fixing In Replacement Of Along The Poles Or Passing Through Pipes Or Laid Under Floor Of Through Walls Etc Jointing And Testing Ltcross Linked Polythene Insulated ( Xlpe Insulated ) Galvanized Steel Striparmoured Electric Cable 1100Volt Grade Heavy Duty Size Of 10 Sqmm 2 Core, Isi Marked With Aluminium Conductor And Overall Served With An Outer Sheath Of Pvc, Of Cross Sectional Areaincluding Taking Down As Under:-Note : ( I ) .Excavation, Earthwork, Sand Cushioning, Cable Covers, Pipe For Cable Protection To Be Measured And Paid For Separately ) ( Ii ) .Retrived Lt Cable Scrap ( Lumpsum ) Shall Be Deposited Age E / Mstoreyard With Own Arrangement By The Contractor . 15 All As Per Serial Item No 7.00 Here-In-Before But Of Size 16 Sqmm 2Core. 16 All As Per Serial Item No 7.00 Here-In-Before But Of Size 16 Sqmm 4 Core. 17 All As Per Serial Item No 7.00Here-In-Before But Of Size 25 Sqmm 4 Core. 18 All As Per Serial Item No 7.00 Here-In-Before But Of Size 35 Sqmm 4 Core. 19 All As Per Serial Item No 7.00 Here-In-Before But Of Size 50 Sqmm 3.5 Core. 20 All As Per Serial Item No 7.00 Here-In-Before But Of Size 70 Sqmm 3.5 Core. 21 All As Per Serial Item No 7.00 Here-In-Before But Of Size 95 Sqmm 3.5 Core. 22 All As Per Serial Item No 7.00 Here-In-Before But Of Size120 Sqmm 3.5 Core. 23 All As Per Serial Item No 7.00 Here-In-Before But Of Size 150 Sqmm 3.5 Core. 24 All As Per Serial Item No 15.00 Here-In-Before But Of Size 240 Sqmm 3.5 Core. 25 All As Per Serial Item No 15.00 Here-In-Before But Of Size 400 Sqmm 3.5 Core. 26 M&L Earthing With Galvanised Steel Earth Plate Electrode 60Cm X 60Cm X 6 Mm Thick, With Earth Strip 25 Mm X 4 Mm Protected By Galvanised Iron Or Steel Pipe 40 Mm Bore Light Grade With Watering Pipe 20 Mm Bore Gimedium Grade.The Rate Of Earthing Shall Be Inclusive Of Necessary Earth Work In Any Type Of Soil, Charcoal, Salt, Funnel, Pcc Pit And Rcc Cover With Handle Complete As Per Electrical Plate No. 3 Of Mes Ssr Part-I Complete All As Specified And Directed By Engr-In-Charge. 27 M&L For Acsr Conductor Of Required Size For Over Head Lines On Poles Including Streching, Tighting Of Poles Insulator With Binding Wire Of Sutable Size With Insulator / Streching Of Acsr Conductor, Including Taking Down Complete All As Specified And Diected By Engr-In-Charge. 28 Taking Down / Dismantling Of Old Unserviceable / Corroded Acsr Conductor Of Any Size From Existing Over Head Lines Completed And Supply, Lay And Fix Aerial Bunched Cable 1.1Kv Grade Stranded And Compact Aluminium Phase Conductor Of Size 4X95 Sqmm + 1X70 Sqmm ( Bare Messenger ) With Aluminium Alloy And Junction Box The Phase Conductor Shall Be Insulated With Xlpe ( Sioplas ) Compound Aluminium As Per Is-14225-1995Including All Fittings Such As Anchor Clamp, Suspension Clamp, Line Connector, Service Clamp, Including End Joints Insulator Piercing Connectors, For Taps From Bare Line Etc Complete All As Specified And As Directed By Engr-In-Charge. 29 Taking Down / Dismantling Of Old Unserviceable / Corroded Acsr Conductor Of Any Size From Existing Over Head Lines Completed And Supply, Lay And Fix Aerial Bunched Cable 1.1Kv Grade Stranded And Compact Aluminium Phase Conductor Of Size 4X70sqmm + 1X50 Sqmm ( Bare Messenger ) With Aluminium Alloy And Junction Box The Phase Conductor Shall Be Insulated With Xlpe ( Sioplas ) Compound Aluminium As Per Is-14225-1995Including All Fittings Such As Anchor Clamp, Suspension Clamp, Line Connector, Service Clamp, Including End Joints Insulator Piercing Connectors, For Taps From Bare Line Etc, Complete All As Specified And As Directed By Engr-In-Charge. 30 Taking Down / Dismantling Of Old Unserviceable / Corroded Acsr Conductor Of Any Size From Existing Over Head Lines Completed And Supply, Lay And Fix Aerial Bunched Cable 1.1Kv Grade Stranded And Compact Aluminium Phase Conductor Of Size 4X 50Sqmm + 1X35 Sqmm ( Bare Messenger ) With Aluminium Alloy And Junction Box The Phase Conductor Shall Be Insulated With Xlpe ( Sioplas ) Compound Aluminium As Per Is-14225-1995Including All Fittings Such As Anchor Clamp, Suspension Clamp, Line Connector, Service Clamp, Including End Joints Insulator Piercing Connectors, For Taps From Bare Line Etc, Complete All As Specified And As Directed By Engr-In-Charge. 31 Taking Down / Dismantling Of Old Unserviceable / Corroded Acsr Conductor Of Any Size From Existing Over Head Lines Completed And Supply, Lay And Fix Aerial Bunched Cable 1.1Kv Grade Stranded And Compact Aluminium Phase Conductor Of Size 4X35sqmm + 1X25 Sqmm ( Bare Messenger ) With Aluminium Alloy And Junction Box The Phase Conductor Shall Be Insulated With Xlpe ( Sioplas ) Compound Aluminium As Per Is-14225-1995Including All Fittings Such As Anchor Clamp, Suspension Clamp, Line Connector, Service Clamp, Including End Joints Insulator Piercing Connectors, For Taps From Bare Line Etc. Complete All As Specified And As Directed By Engr-In-Charge. 32 M&L For Boring For Laying Of Cable / Pipe And Making Good The Disturbed / Excavated Surface As Per Existing Road Including Refilling The Excavated Material, Compacting, Wbm And Black Top Carpeting With Bitumen & Aggregate Following The Stone / Sand On Top Complete All As Specified By Engr-In-Charge. 33 S&F Tubing Lightgrade Galvanised Iron Size Of 80 Mm Bore With All Fittings And Fixed To Poles, Walls Etc. With Flat Iron Clamps / Bolts / Nuts / Washers Or Laid In Floors / Under Roads Complete All As Specified And Directed By Engr-In-Charge. 34 All As Per Serial Item No 15.00 Here-In-Before But Of Size 50 Mm Bore. 35 All As Per Serial Item No 15.00 Here-In-Before But Of Size 100 Mm Bore. 36 Lopping / Prooning Of Tree Branches Upto The Extend To Obtain Clearance All Around The Ht / Lt Over Headlines Conductor Upto 3 Mtr From Farthest Conductor On Pole Including Removing Of Cut Branches & Cleaning Of Site Compleall As Specified And Directed By Engr-In-Charge. Note:- ( A ) The Trees Branches Etc Will Be Left As It Is & Will Not Be Carried Away By The Contractor / Del As The Wood Belongs To Ceo / Deo & They Will Be Responsiblr To Lift The Wood. ( B ) Pruning Of All Tree Branches In One Tree Shall Be Measured As One Job. ( C ) Contractor Will Employ Sufficient Labour To Complete The Job With In Time As Directed. ( D ) Contractor Will Be Responsible For Any Type Mis-Happening / Accident While Pruning The Trees. ( E ) Contractor Supervisor Will Take Proper Shut Down From Mes Installation Before Starting The Work & Clear It Before Resuming Power Supply. However, Full Assistance Will Be Provided By Mes Staff. ( F ) The Contractor Will Provide Proper Tools & Safety To His Staff For Purning Of Trees. 37 S&F Straight Through Joint Kit, Heat Shrinkable Type Suitable For 70To 95 Sqmm Lt Ug Cable Complete All As Specified And Directed By Engr-In-Charge. 38 S&F Straight Through Joint Kit, Heat Shrinkable Type Suitable For 120 To 185 Sqmm Lt Ug Cable Complete All As Specified And Directed By Engr-In-Charge. 39 S&F Straight Through Joint Kit, Heat Shrinkable Type Suitable For 240 To 400 Sqmm Lt Ug Cable Complete All As Specified And Directed By Engr-In-Charge. 40 Disconnecting & Taking Out The Existing Unserviceable Mccb From Panel And S&F New Mccb 63 Amp, 25Ka Breaking Cap Of Suitable Frame Size, 4 Pole, 415 V, 50 Hz, 3 Phase Including Extension Terminals And Connecting Using Suitable Fasteners, Modification / Fabrication If Anycomplete All As Required At Site Complete All Asspecified And Directed By Engr-In-Charge. 41 All As Per Serial Item No 20.00 Here-In-Before But Of Size 100 Amp, 25 Ka. 42 All As Per Serial Item No 20.00 Here-In-Before But Of Size 125 Amp, 25 Ka. 43 All As Per Serial Item No 20.00 Here-In-Before But Of Size 160 Amp, 25 Ka. 44 All As Per Serial Item No 20.00 Here-In-Before But Of Size 200 Amp, 25 Ka. 45 All As Per Serial Item No 20.00 Here-In-Before But Of Size 250 Amp, 25 Ka. 46 All As Per Serial Item No 20.00 Here-In-Before But Of Size 320 Amp, 25 Ka. 47 All As Per Serial Item No 20.00 Here-In-Before But Of Size 400 Amp, 25 Ka. 48 All As Per Serial Item No 20.00 Here-In-Before But Of Size 630 Amp, 25 Ka. 49 Disconnecting & Taking Out The Existing Unserviceable Acb From Panel And S&F New Acb 800 Amp, 50 Ka Breaking Cap Of Suitable Frame Size, 4 Pole, 415 V, 50 Hz, 3 Phase Including Extension Terminals And Connecting Using Suitable Fasteners, Modification / Fabrication If Anycomplete All As Required At Site Complete All As Specified And Directed By Engr-In-Charge. 50 Disconnecting & Taking Out The Existing Unserviceable Acb From Panel And S&F New Acb 1000 Amp, 50 Ka Breaking Cap Of Suitable Frame Size, 4 Pole, 415 V, 50 Hz, 3 Phase Including Extension Terminals And Connecting Using Suitable Fasteners, Modification / Fabrication If Anycomplete All As Required At Site Complete All As Specified And Directed By Engr-In-Charge. 51 M&L For Aluminium Thimble Cable ( Lugs ) Suitable For Cable Of Size 25 Sqmm To 70Sqmm Complete All As Specified And Directed By Engr-In-Charge. 52 All As Per Serial Item No 23.00 Here-In-Before But Of Size 95 Sqmm To 120 Sqmm. 53 All As Per Serial Item No 23.00 Here-In-Before But Of Size 150 Sqmm To 240 Sqmm. 54 All As Per Serial Item No 23.00 Here-In-Before But Of Size 300 Sqmm To 400 Sqmm. 55 Supply, Install, Testing And Commissioning And Testing Factory Made And Tested Cpri Type Test Certified ) Junctionboxout Door Type, Floor Mounted, Compertmantalised Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet With Digital Volt Meter, Ammeter, With Cts , Led Lamps Ryb For All Incomers & Outgoings Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Having Front And Rear Openeable Hinged Double Door Shutters With Aprons For Cable Entryand Locking Arrangement Complete Including Taking Downold U / S Busbar With Following :-Incoming ( A ) Mccb 200 Amps, 4 Pole, 50Hz , 415 V With Rupturing Capacity 35 / 36 Ka-01 No. 56 Outgoing :- ( A ) Bus Bar Electrolytic Grade Copper300 Amps 4 Pole And Supported On Non-Hygroscopic, Non Carbonising, Corrosion Resistance Smc Insulators Not Less Than 1 Mtr Long Mounted On Insulators For Incomming Supply 01 No.Note :- ( I ) Rate Quoted Is Deemed To Be Inclusive Of Pcc Foundation / Pedestrian And Connected Earth Work. ( Ii ) Panels Shall Be Placed Above 0.6 Mtr Of Ground Level. ( Iii ) Outgoing Mccbs Shall Be Fed With Solid Busbar Connectors. ( Iv ) Cables Shall Be Terminated Using Gun Metal / Ss Glands. ( V ) Cable Glands For Suitableincomingand Out Going Cablesfixed Is Including Rate Quated By Vendor. 57 Supply, Install, Testing And Commissioning And Testing Factory Made And Tested Cpri Type Test Certified ) Junctionboxout Door Type, Floor Mounted, Compertmantalised Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet With Digital Volt Meter, Ammeter, With Cts , Led Lamps Ryb For All Incomers & Outgoings Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Having Front And Rear Openeable Hinged Double Door Shutters With Aprons For Cable Entryand Locking Arrangement Complete Including Taking Downold U / S Busbar With Following :-Incoming:- ( A ) Mccb 4 Pole , Ics=100%Icu- 35 / 36 Ka, 415 Volts, 160 Amps , With Thermal Adjustable And Fixed Magnetic Setting With Extended Terminals-01 Nos. 58 Outgoing :- ( A ) Bus Bar Electrolytic Grade Copper And Supported On Non-Hygroscopic, Non Carbonising, Corrosion Resistance Smc Insulators 300 Amp, 4 Pole - 01 Set.Note :- ( I ) Rate Quoted Is Deemed To Be Inclusive Of Pcc Foundation / Pedestrian And Connected Earth Work. ( Ii ) Panels Shall Be Placed Above 0.6 Mtr Of Ground Level. ( Iii ) Outgoing Mccbs Shall Be Fed With Solid Busbar Connectors. ( Iv ) Cables Shall Be Terminated Using Gun Metal / Ss Glands. ( V ) Includingsuitable Thimbles / Lugs, Nut Bolts , Washersfitted The Cables. ( Vi ) Cable Glands For Incoming Lt Cable 120 Sqmm -03 Nos And Out Going Cables 95 Sqmm -03 Nos And 50 Sqmm - 02 Nos Is Including Rate Quated By Vendor. 59 Supply, Install, Testing And Commissioning And Testing Factory Made And Tested Cpri Type Test Certified ) Junctionboxout Door Type, Floor Mounted, Compertmantalised Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet With Digital Volt Meter, Ammeter, With Cts , Led Lamps Ryb For All Incomers & Outgoings Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Having Front And Rear Openeable Hinged Double Door Shutters With Aprons For Cable Entryand Locking Arrangement Complete Including Taking Downold U / S Busbar With Following :-Incoming:- ( A ) On Loadchange Over 100 A4 Pole, With Thermal Adjustable And Fixed Magnetic Setting With Extended 50Hz , 415 V With Rupturing Capacity 35 Ka-01 No. ( B ) Bus Bar Electrolytic Grade Copper And Supported On Non-Hygroscopic, Non Carbonising, Corrosion Resistance Smc Insulators 200 Amp, 4 Pole, Not Less Than 1 Mtrlong Mounted On Insulators 01 Set. 60 Outgoing:- ( A ) Mccb 125 A4 Pole, With Thermal Adjustable And Fixed Magnetic Setting With Extended 50Hz , 415 V With Rupturing Capacity 35 Ka-01 No. ( B ) Mccb 4 Pole , Ics=100%Icu-25 / 26 Ka, 415 Volts, 63 Amps , With Thermal Adjustable And Fixed Magnetic Setting With Extended Terminals-04Nos.Note :- ( I ) Rate Quoted Is Deemed To Be Inclusive Of Pcc Foundation / Pedestrian And Connected Earth Work. ( Ii ) Panels Shall Be Placed Above 0.6 Mtr Of Ground Level. ( Iii ) Outgoing Mccbs Shall Be Fed With Solid Busbar Connectors. ( Iv ) Cables Shall Be Terminated Using Gun Metal / Ss Glands. ( V ) Cable Glands For Incoming Lt Cable 95 Sqmm -01 Nos And Out Going Cables 70 Sqmm -02 Nos And 50 Sqmm - 01 Nosand 25 Sqmm -04 Nos Is Including Rate Quated By Vendor. 61 Supply, Install, Testing And Commissioning And Testing Factory Made And Tested Cpri Type Test Certified ) Junctionboxout Door Type, Floor Mounted, Compertmantalised Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, Dust And Vermin Proof, Made Of 3.15Mm Crca Ms Sheet With Digital Volt Meter, Ammeter, With Cts , Led Lamps Ryb For All Incomers & Outgoings Base Frame Of 50X50x6mm Angle Iron , Powder Coated, Having Front And Rear Openeable Hinged Double Door Shutters With Aprons For Cable Entryand Locking Arrangement Complete Including Taking Downold U / S Busbar With Following :-Incoming:- ( A ) Mccb100 A 4 Pole , Ics=100%Icu- 25 Ka, 415 Volts, With Thermal Adjustable And Fixed Magnetic Setting With Extended Terminals-01. 62 Outgoing:- ( A ) Bus Bar Electrolytic Grade Copper 200 Amp, 4 Pole, Not Less Than 1.5 Mtr Long Smc Insulators Mounted On Insulators - 01 Set.Note :- ( I ) Rate Quoted Is Deemed To Be Inclusive Of Pcc Foundation / Pedestrian And Connected Earth Work. ( Ii ) Panels Shall Be Placed Above 0.6 Mtr Of Ground Level. ( Iii ) Outgoing Mccbs Shall Be Fed With Solid Busbar Connectors. ( Iv ) Cables Shall Be Terminated Using Gun Metal / Ss Glands. ( V ) Cable Glands For Incoming Lt Cable 240 Sqmm -03 Nos And Out Going Cables 95Sqmm -02 Nos And 50 Sqmm-2 Nos Is Including Rate Quated By Vendor. 63 S&F Of Steel Tubular Swaged Poles Erected To Truly Vertical Or Planted As Strut Complete With 6 Mm Thick Mild Steel Base Plate, Welded To Pole, B-118 Finial Taper Cap, Bolts, Nuts And Screws, Poles Made Out Of Erw Ms Tubing Conforming To Is-2713 Part-Ii Type 410-Sp-31 ( 9M Long ) Including Drilling Of Holes Of Required Size For Fixing Of Cross Arms, Painting The Exposed Surfaces Of Pole With Two Coats Of Aluminum Paint Over A Coat Of Red Oxide Zinc Chrome Primer And With Two Coats Of Black Bituminous Paint On The And Portion Embedded In Concrete, Making Five Black And White Bands At Lower Portion Of Pole Above Ground Level / Coping Each300 Mm Wide Alternately And Marking Pole Number. With Black Paint At Suitable Height All As Specified And Directed By Engineer-In-Charge. Note:- The Earthwork, Pcc Foundation, Steel Clamps, Ms Cross Arms & Bracing Of Angle Iron Etc Will Be Measured And Paid Separately Under Relevant Items Of Sch ‘A’. 64 M&L For Replacement Of Earthing With Copperearth Plate Electrode 600 X 600 X 3 Mm Buried Directly In Ground ( Earth Pit Not Less Than 2.25 M Deep Below Ground Level ) With Top Edge Of The Earth Plate Not Less Than 1.5 M Below Ground Level Connected To Copperstrip 20X3 Mm Thick For Earthing Lead Fixed By Means Of Nuts, Bolt, Washers Etc Connected To Earth Test Point Complete All As Specified In Electrical Plate No 3 Of Ssr-2009 Part 1, Including Necessary Excavation And Earth Work In Any Type Of Soil, Comman Salt, Charcoal Dust, 40 Mm Dia Light Grade Gi Pipe For Protection To Earth Lead, Gi Water Pipe20mm Dia With Funnel &Wire Mesh, Pcc Pit With Ci Cover And Frame Etc Complete All As Specified And Directed By Engr-In-Charge.Note: - ( I ) All The Joints Shall Be Made With Welding To Get Proper Conductivity. ( Ii ) On Testing After Completion Of Earthing, If Desired Earth Resistance Is Not Obtained, The Earthing Will Be Re-Done By The Contractor At His Own Risk & Cost To The Entire Satisfaction Of Engr-In-Charge. 65 Supply, Install, 150 Amp Copperbus Barwith Enclouser Wall Mounted Size 300 Mmx250 Mm , Suitable For 415 Volts 3 Phase 4 Wire, 50 Hz Ac Supply System, Dust And Vermin Proof, Made Of 2 Mm Crca Ms Sheet For Cable Entryand Locking Arrangement Complete All As Specified And Directed By Engr-In-Charge. 66 M&L Plain Cement Concrete 1:3:6 Type C-2 As In Foundations Filling And Mass Concrete Using 40 Mm Graded Stone Aggregate Complete All As Specified And Directed By Engr-In-Charge. 67 M&L Plain Cement Concrete 1:2:4 Type B-1 Using 20 Mm Graded Stone Aggregate For Coping Of Poles Complete All As Specified And Directed By Engr-In-Charge. 68 S & F Stay Assembly For Lt Steel Tubular Poles Comprising Of 7 / 10 Swg Galvanized Ms Stranded Stay Wire Of Required Length, Minimum Tensile Strength 70 Kg / Mm ( Grade-2 Quality ) Fixed To Pole With And Including Fi Clamps Bolts, Nuts, Washers, Galvanized Steel Stay Rod 16Mm Dia 180 Cm Long Bow 400X14mm Nuts / Bolts, Washers All Galvanized And Two Nos Thimble, Loop Insulator Of Size 65X90mm Vitreous, Clearance Dia Of Hole 16Mm, Stayplate Of Size 230X230x6mm Including Necessary Excavation And Earth Work Pcc 1:3:6 Type C-2 Using 40Mm Graded Crushed Stone Aggregate In Foundation And Disposal Of Surplus Spoil, Upto 50 M All As Specified And Shown In Plate No 1 Of Mes Ssr Pt -I, Complete All As Specified And Directed By Engr-In-Charge. 69 Supply , Fabricating Andfixing In Repairs Cross Arms ( Any Type ) Supports, Bracing, Stiffeners Anti Climbing Spikes Etcmade Out Of Ms Channel, Angle Iron, Flat Of Any Sizeincluding Drillingof Holes Making Clamps Including Eye Hooks, Nuts Bolts And Washers Etc Welding Ifrequired Including Painting With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer Complete All As Specified And Directed By Engr-In-Charge. 70 M & L For Painting To Steel Tubular Swaged Pole Of Overhead Lines ( 9 Mtr Long ) Complete With And Including Comprising The Following Works :- ( A ) Scraping Out Wornout Old Paint And Making The Surface Smooth. ( B ) Painting The Pole And All Ms Work Mounted Onpole With Two Coats Of Syntheticenameled Paint ( Aluminium Shade ) As Directed By Engg.-In-Charge. ( C ) Forming Five Nos Coloured Bands At Lower Portion Of Pole Each 300 Mm Wide Alternatively With White And Black Colour ( Or Any Colour As Approved By Engg.-In-Charge ) Synthetic Enameled Paint And Marking Pole No. With Black And White Paint Complete All As Specifie And Directed By Engr-In-Charge. 71 Supply And Fixing Pvc Insulation Tape Red, Yellow, Blue Colour 25 Mm 25 Mtr Length Tape Roll Complete All As Specified And Directed By Engr-In-Charge. 72 S&F Double Walled Corrugated ( Dwc ) Pipe Of Size 120 Mm Including Snap Fit Coupler Conforming To Is14930 ( Pt-Ii ) / Is16205 Pt-Ii For Protection Of Ht Cable In Under Ground Complete All As Specified And Directed By Enger-In-Charge. 73 S&F Double Walled Corrugated ( Dwc ) Pipe Of Size 77 Mm Including Snap Fit Coupler Conforming To Is14930 ( Pt-Ii ) / Is16205 Pt-Ii For Protection Of Ht Cable In Under Ground Complete All As Specified And Directed By Engr-In-Charge. 74 S&F Double Walled Corrugated ( Dwc ) Pipe Of Size 50 Mm Including Snap Fit Coupler Conforming To Is14930 ( Pt-Ii ) / Is16205 Pt-Ii For Protection Of Ht Cable In Under Ground Complete All As Specified And Directed By Engr-In-Charge. 75 M&L For Surface Cleaning By Removing The Roots Completely From The Earth, Shrubs, Vegetation, Grass, Bushes, Weeds By Excavation Not Exceeding 30Cm And Averaging 15Cm Deep Including Sweeping Removing The Same To Distance Not Exceeding 50M Away From The Installation And Burning The Complete All As Specified And Directed By Engr-In-Charge. 76 1100 Volts Grade Heavy Duty Cable Pvc ( In Replacement ) Insulated Stranded Aluminium Conductor Served With Inner Sheathing Of Pvc Tape And Over All Pvc Sheathed In Service Conncetions One Twin Core 10 Sqmm Cable Flat Or Round Complete All As Specified And Directed By Engr-In-Charge.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-08-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair/maint to LT network system in the AOR of CPH area under GE (Utilities) Udhampur.
Sl. No. Item Description
1Laying, jointing, fixingor passing through pipe, trenches or duct FRLS, XLPE insulated screenedand PVC sheathed armouredelectric powerL Tcable heavy duty with aluminium conductor 3.5 core nominal cross sectional area 25 Sqmm all as specified and as directed. Note : Cable for Srl item Nos 1 to 1.07 shall be issued under Sch "B".
2All as per serial item No 1 here-in-before but of size 35 sqmm 3.5 core.
3All as per serial item No 1here-in-before but of size 50 sqmm 3.5 core.
4All as per serial item No 1 here-in-before but of size 70 sqmm 3.5 core.
5All as per serial item No 1 here-in-before but of size 120 sqmm 3.5 core.
6All as per serial item No 1 here-in-before but of size 150 sqmm 3.5 core.
7All as per serial item No 1 here-in-before but of size 240 sqmm 3.5 core.
8All as per serial item No 1 here-in-before but of size 300 sqmm 3.5 core.
9Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundations of poles/stays etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and as directed by Engr-in-Charge.
10Returning, filling in excavated soil in trenches including spreading, leveling, watering and well rammingin layers n. exc. 25 cm thick complete all as specified and directed by Engr-in-Charge.
11Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
12Opening, maintenance and general servicing of Servo voltage stablizers of different makes (Rating from 100 KVA to 400 KVA) including removal of sludge from disserstate coils, Buck Boost Transfromers, tightening of all nut bolts, cleaning of stablizer coils,checking and servicing of servo mechanism, gear synchronising system, automatice voltage regulator circuits and other allied electrical components complete all as specified and directed by Engr-in-Charge. Note:- Rate quoted by contractor is inclusive of following items:-(a) Servo motorwith RC net work having torque of 3 kg/cm -1 No (b)Servo motorwith RC net work having torque of 10 kg/cm -1 No (c) Electronic control card for automatic voltageregulation - 1 No ( d) Transformer oil - 35 Ltr( e) Volt meter 0-500 capacity -1 No( f) Ammeter CT Operated-1 No (g) Circuit plate 30 KVA - 400 KVA - 1 No (h) Pulse transformer of cap 30 KVA - 400 KVA - 1 No( i) Rewinding for copper coil -25 Kg (j) Shifting of stablizer from AOR of MPH to workshop (Tro/Fro) (k) OEM Service engineer shall be engage for rectification of defects (l) Minor items like Carbon Brush, Push buttons,Auto/Manual/Micro press switch,indicators Lamps, Voltmeter/Ammeter selector switch. (m) Contractor must provide replacement of suitable Stablizer for use until it get repaired from Workshop.
13Decarbonising of LT Panel board / Feeder pillar boxes by CTC( Carbon Tetra Chloride), removing the carbon deposited inside the panel, cleaning the panel with cotton waste,applying one coat of becktol red solution, checking the faults inside the panel board and charging the LT Panel post completion of decarbonisation complete all as specified and directed by Engr-in-Charge. Note : (a) Proper shut down shall be taken prior the commencement of work . (b) Contractor shall provide 2 bottles of (250ml) - CTC . Cotton waste of not less than -1kg and Dr Bectol solution (250ml) - 1 no for performing the decarbonisation. (c) Fabrication of LT Panels for broken hinges shall be rectified. (d)LT Panel shall be painted withtwo coats of synthetic enamel paint over a coat of red oxide primer. (e)Marking on LT panels shall be done as per sources of power supply (1100 volts) and outgoing area by 10cm glow sign/paint all as directions of Engr-in-Charge.
14Supply and Laying and fixing in replacement of along the poles or passing through pipes or laid under floor of through walls etc jointing and testing LTCross Linked Polythene Insulated(XLPE insulated) galvanized steel striparmoured electric cable 1100volt grade heavy duty size of 10 Sqmm 2 core, ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional areaincluding taking down as under:- Note : (i).Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately)(ii) .Retrived LT cable scrap ( Lumpsum ) shall be deposited AGE E/Mstoreyard with own arrangement by the contractor .
15All as per serial item No 7.00 here-in-before but of size 16 sqmm 2core.
16All as per serial item No 7.00 here-in-before but of size 16 sqmm 4 core.
17All as per serial item No 7.00here-in-before but of size 25 sqmm 4 core.
18All as per serial item No 7.00 here-in-before but of size 35 sqmm 4 core.
19All as per serial item No 7.00 here-in-before but of size 50 sqmm 3.5 core.
20All as per serial item No 7.00 here-in-before but of size 70 sqmm 3.5 core.
21All as per serial item No 7.00 here-in-before but of size 95 sqmm 3.5 core.
22All as per serial item No 7.00 here-in-before but of size120 sqmm 3.5 core.
23All as per serial item No 7.00 here-in-before but of size 150 sqmm 3.5 core.
24All as per serial item No 15.00 here-in-before but of size 240 sqmm 3.5 core.
25All as per serial item No 15.00 here-in-before but of size 400 sqmm 3.5 core.
26M&L earthing with galvanised steel earth plate electrode 60cm x 60cm x 6 mm thick, with earth strip 25 mm x 4 mm protected by galvanised iron or steel pipe 40 mm bore light grade with Watering pipe 20 mm bore GImedium grade.The rate of earthing shall be inclusive of necessary earth work in any type of soil, charcoal, salt, funnel, PCC pit and RCC cover with handle complete as per electrical plate No. 3 of MES SSR Part-I complete all as specified and directed by Engr-in-Charge.
27M&L for ACSR conductor of required size for over head lines on poles including streching,tighting of poles insulator with binding wire of sutable size with insulator/streching of ACSR conductor, including taking down complete all as specified and diected by Engr-in-Charge.
28Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1.1KV grade stranded and compact aluminium phase conductor of size 4x95 sqmm + 1x70 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc complete all as specified and as directed by Engr-in-Charge.
29Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1.1KV grade stranded and compact aluminium phase conductor of size 4x70sqmm + 1x50 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc, complete all as specified and as directed by Engr-in-Charge.
30Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1.1KV grade stranded and compact aluminium phase conductor of size 4x 50sqmm + 1x35 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc, complete all as specified and as directed by Engr-in-Charge.
31Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1.1KV grade stranded and compact aluminium phase conductor of size 4x35sqmm + 1x25 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and as directed by Engr-in-Charge.
32M&L for Boring for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified by Engr-in-Charge.
33S&F tubing "lightgrade" galvanised iron size of 80 mm bore with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed by Engr-in-Charge.
34All as per serial item No 15.00 here-in-before but of size 50 mm bore.
35All as per serial item No 15.00 here-in-before but of size 100 mm bore.
36Lopping/prooning of tree branches upto the extend to obtain clearance all around the HT/LT over headlines conductor upto 3 mtr from farthest conductor on pole including removing of cut branches & cleaning of site compleall as specified and directed by Engr-in-Charge. Note:- (a) The trees branches etc will be left as it is & will not be carried away by the contractor/DEL as the wood belongs to CEO/DEO & they will be responsiblr to lift the wood. (b) Pruning of all tree branches in one tree shall be measured as one Job. (c ) Contractor will employ sufficient labour to complete the Job with in time as directed. (d) Contractor will be responsible for any type mis-happening/accident while pruning the trees. (e) Contractor supervisor will take proper shut down from MES installation before starting the work & clear it before resuming power supply. However, full assistance will be provided by MES staff. (f) The contractor will provide proper tools & safety to his staff for purning of trees.
37S&F straight through joint kit, heat shrinkable type suitable for 70to 95 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
38S&F straight through joint kit, heat shrinkable type suitable for 120 to 185 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
39S&F straight through joint kit, heat shrinkable type suitable for 240 to 400 sqmm LT UG Cable complete all as specified and directed by Engr-in-Charge.
40Disconnecting & taking out the existing Unserviceable MCCB from panel and S&F new MCCB 63 amp, 25KA breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase including extension terminals and connecting using suitable fasteners, modification/fabrication if anycomplete all as required at site complete all asspecified and directed by Engr-in-Charge.
41All as per serial item No 20.00 here-in-before but of size 100 amp, 25 KA.
42All as per serial item No 20.00 here-in-before but of size 125 amp, 25 KA.
43All as per serial item No 20.00 here-in-before but of size 160 amp, 25 KA.
44All as per serial item No 20.00 here-in-before but of size 200 amp, 25 KA.
45All as per serial item No 20.00 here-in-before but of size 250 amp, 25 KA.
46All as per serial item No 20.00 here-in-before but of size 320 amp, 25 KA.
47All as per serial item No 20.00 here-in-before but of size 400 amp, 25 KA.
48All as per serial item No 20.00 here-in-before but of size 630 amp, 25 KA.
49Disconnecting & taking out the existing Unserviceable ACB from panel and S&F new ACB 800 amp, 50 KA breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase including extension terminals and connecting using suitable fasteners, modification/fabrication if anycomplete all as required at site complete all as specified and directed by Engr-in-Charge.
50Disconnecting & taking out the existing Unserviceable ACB from panel and S&F new ACB 1000 amp, 50 KA breaking cap of suitable frame size, 4 Pole, 415 V, 50 Hz, 3 phase including extension terminals and connecting using suitable fasteners, modification/fabrication if anycomplete all as required at site complete all as specified and directed by Engr-in-Charge.
51M&L for aluminium thimble cable (Lugs) suitable for Cable of size 25 sqmm to 70Sqmm complete all as specified and directed by Engr-in-Charge.
52All as per serial item No 23.00 here-in-before but of size 95 sqmm to 120 sqmm.
53All as per serial item No 23.00 here-in-before but of size 150 sqmm to 240 sqmm.
54All as per serial item No 23.00 here-in-before but of size 300 sqmm to 400 sqmm.
55Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) Junctionboxout door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete including taking downold U/S busbar with following :- Incoming (a) MCCB 200 amps, 4 pole, 50Hz ,415 V with rupturing capacity 35/36 KA-01 No.
56Outgoing :- (a)Bus bar electrolytic grade copper300 amps 4 pole and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators not less than 1 Mtr long mounted on insulators for incomming supply 01 No. Note :-(i) Rate quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. (ii)Panels shall be placed above 0.6 mtr of ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) Cable glands for suitableincomingand out going cablesfixed is including rate quated by vendor.
57Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) Junctionboxout door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete including taking downold U/S busbar with following :- Incoming:- (a) MCCB 4 pole ,Ics=100%Icu- 35/36 KA, 415 Volts, 160 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals-01 Nos.
58Outgoing :- (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 300 Amp,4 pole - 01 set. Note :-(i) Rate quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. (ii)Panels shall be placed above 0.6 mtr of ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) includingsuitable thimbles/lugs, nut bolts ,washersfitted the cables. (vi) cable glands for incoming LT cable 120 sqmm -03 Nos and out going cables 95 sqmm -03 Nos and 50 sqmm - 02 Nos is including rate quated by vendor.
59Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) Junctionboxout door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete including taking downold U/S busbar with following :- Incoming:- (a) ON LoadChange over 100 A4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No. (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 200 Amp,4 pole, not less than 1 MTRlong mounted on insulators 01 set.
60Outgoing:- (a)MCCB 125 A4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No. (b) MCCB 4 pole , Ics=100%Icu-25/26 KA, 415 Volts, 63 Amps ,with thermal adjustable and fixed magnetic setting with extended terminals-04Nos. Note :-(i) Rate quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. (ii)Panels shall be placed above 0.6 mtr of ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) cable glands for incoming LT cable 95 sqmm -01 Nos and out going cables 70 sqmm -02 Nos and 50 sqmm - 01 Nosand 25 sqmm -04 Nos is including rate quated by vendor.
61Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified) Junctionboxout door type, floor mounted,compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs ,Led lamps RYB for all incomers & outgoings base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entryand locking arrangement complete including taking downold U/S busbar with following :- Incoming:- ( a) MCCB100 A 4 pole ,Ics=100%Icu- 25 KA, 415 Volts,with thermal adjustable and fixed magnetic setting with extended terminals-01.
62Outgoing:- (a)Bus bar electrolytic grade copper 200 Amp,4 pole, not less than 1.5 Mtr long SMC insulators mounted on insulators - 01 set. Note :-(i) Rate quoted is deemed to be inclusive of PCC foundation/pedestrian and connected earth work. (ii)Panels shall be placed above 0.6 mtr of ground level. (iii) Outgoing MCCBs shall be fed with solid busbar connectors. (iv) Cables shall be terminated using gun metal /SS glands. (v) Cable glands for incoming LT cable 240 sqmm -03 Nos and out going cables 95sqmm -02 Nos and 50 Sqmm-2 Nos is including rate quated by vendor.
63S&F of Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each300 mm wide alternately and marking pole number. with black paint at suitable height all as specified and directed by Engineer-in-Charge. Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’.
64M&L for replacement of earthing with Copperearth plate electrode 600 x 600 x 3 mm buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the earth plate not less than 1.5 M below ground level connected to Copperstrip 20X3 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR-2009 part 1, including necessary excavation and earth work in any type of soil, comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe20mm dia with funnel &wire mesh, PCC pit with CI cover and frame etc complete all as specified and directed by Engr-in-Charge. Note: - (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engr-in-Charge.
65Supply, install,150 amp copperBus barwith enclouser wall mounted size 300 mmX250 mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system,dust and vermin proof, made of 2 mm CRCA MS sheet for cable entryand locking arrangement complete all as specified and directed by Engr-in-Charge.
66M&L Plain cement concrete 1:3:6 type C-2 as in foundations filling and mass concrete using 40 mm graded stone aggregate complete all as specified and directed by Engr-in-Charge.
67M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping of poles complete all as specified and directed by Engr-in-Charge.
68S & F stay assembly for LT steel tubular poles comprising of 7/10 SWG galvanized MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps bolts, nuts, washers, galvanized steel stay rod 16mm dia 180 cm long bow 400x14mm nuts/bolts, washers all galvanized and two nos thimble, loop insulator of size 65x90mm vitreous, clearance dia of hole 16mm, stayplate of size 230x230x6mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregate in foundation and disposal of surplus spoil, upto 50 M all as specified and shown in plate No 1 of MES SSR Pt -I, complete all as specified and directed by Engr-in-Charge.
69Supply ,fabricating andfixing in repairs cross arms ( any type) supports, bracing, stiffeners anti climbing spikes etcmade out of MS channel, angle iron, flat of any sizeincluding drillingof holes making clamps including eye hooks, nuts bolts and washers etc welding ifrequired including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
70M & L for painting to steel tubular swaged pole of Overhead lines (9 Mtr long) complete with and including comprising the following works :- (a)Scraping out wornout old paint and making the surface smooth. (b) Painting the pole and all MS work mounted onpole with two coats of syntheticenameled paint (Aluminium shade) as directed by Engg.-in-charge. (c) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engg.-in-charge)synthetic enameled paint and marking pole no. with black and white paint complete all as specifie and directed by Engr-in-Charge.
71Supply and fixing PVC insulation tape red,yellow, blue colour 25 mm 25 mtr length tape Roll complete all as specified and directed by Engr-in-Charge.
72S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Enger-in-Charge.
73S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
74S&F double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of HT cable in under ground complete all as specified and directed by Engr-in-Charge.
75M&L for Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 30cm and averaging 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the complete all as specified and directed by Engr-in-Charge.
761100 Volts grade heavy duty cable PVC (in replacement ) insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service conncetions one twin core 10 Sqmm cable flat or round complete all as specified and directed by Engr-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail