| 1 | Part A - Cost of Pole,Breaker,Transformer & Other Material) |
| 2 | Supply,Erection,testing & commissioning of 63 KVA transformer 11/0.4 KV , BIS level-II star 1 as per technical specification & direction of EIC. |
| 3 | Supply,Erection,testing & commissioningof 150×150 Mtr RS Joist Pole (11mtr long)(34.6kg/mtr) including excavation of pole pit in all kind of soil and rock up to a depth of 1.5 mtr from ground level as required as per technical specification & direction of EIC. |
| 4 | Supply,Erection,testing & commissioningof 9 mtr long PSC Pole for 11 kV Line including excavation of pole pit in all kind of soil and rock up to a depth of 1.5 mtr from ground level as required as per technical specification & direction of EIC. |
| 5 | Supply,Erection,testing & commissioning of Accessories for Tapping Arrangement for conductor on 11 KV Feeder as per technical specification & direction of EIC. |
| 6 | SITC of75x40x6mm. Channel for Straight Cross-arm(1.2mtr.X 4nos.) as per technical specifications and direction of EIC. |
| 7 | SITC of11KV T&C Disc Insulator as per technical specifications and direction of EIC. |
| 8 | SITC of11KV T&C Hardware Fitting as per technical specifications and direction of EIC. |
| 9 | SITC of11KV Pin Insulator as per technical specifications and direction of EIC. |
| 10 | SITC of11KV G.i Pin as per technical specifications and direction of EIC. |
| 11 | SITC ofH.T. Stay Set Complete as per technical specifications and direction of EIC. |
| 12 | SITC ofHT Stay Insulator as per technical specifications and direction of EIC. |
| 13 | SITC ofStay clamp as per technical specifications and direction of EIC. |
| 14 | SITC of7/10 SWG Stay Wire as per technical specifications and direction of EIC. |
| 15 | SITC ofG.I. Nuts, bolt & Washer as per technical specifications and direction of EIC. |
| 16 | SITC of concrete materials for Stay Anchor plate as required and as per the direction of EIC. |
| 17 | SITC of Padding and Concreting material for support to pole as required and as per the direction of EIC. |
| 18 | SITC ofEarthing of support (Coil Type) as per technical specifications and direction of EIC. |
| 19 | Supply,Erection,testing & commissioning of 11 KV line on 11mtr RS Joist pole 150x150mm with 100mm2 AAAC conductor (except cost of pole) as per technical specification & direction of EIC. |
| 20 | SITC of 100mm²AAAC as per technical specification & direction of EIC. |
| 21 | SITC of Top Channel 100x50x6mm as per technical specification & direction of EIC. |
| 22 | SITC ofBracing Channel 75x40x6mm as per technical specification & direction of EIC. |
| 23 | SITC of Bracing Angle 50x50x6mm as per technical specification & direction of EIC. |
| 24 | SITC of 11 KV V- Cross Arm (MS) (10.2 Kg each) as per technical specification & direction of EIC. |
| 25 | SITC ofBack Clamp for \"V\" Cross Arm (1.7kg) as per technical specification & direction of EIC. |
| 26 | SITC of 11 KV F Clamp 2.9 Kg. Eachas per technical specification & direction of EIC. |
| 27 | SITC of 11KV Disc Insulator (B & S) as per technical specification & direction of EIC. |
| 28 | SITC of 11KV H/W Fitting (B & S type) as per technical specification & direction of EIC. |
| 29 | SITC of 11KV Pin Insulator as per technical specification & direction of EIC. |
| 30 | SITC of 11KV GI Pin as per technical specification & direction of EIC. |
| 31 | SITC of H.T.Stay set complete as per technical specification & direction of EIC. |
| 32 | SITC of Stay Insulatoras per technical specification & direction of EIC. |
| 33 | SITC of Stay clamp as per technical specification & direction of EIC. |
| 34 | SITC of 7/10 SWG Staywire as per technical specification & direction of EIC. |
| 35 | SITC of Earthing of support (Coil Type)as per technical specification & direction of EIC. |
| 36 | SITC of concrete materials for Stay Anchor plate as required and as per the direction of EIC. |
| 37 | SITC of Padding and Concreting material for support to pole as required and as per the direction of EIC. |
| 38 | SITC of G.I. Nuts, bolt & Washer as per technical specification & direction of EIC. |
| 39 | SITC of Sundries (Paint, danger Board, Clamp, Connectors, Anticlimbing device, Binding Tape, etc.) as required and as per the direction of EIC. |
| 40 | Supply,Erection,testing & commissioning of 11 KV Line with 400 AMP AB switch (D.P. Structured) as per technical specification & direction of EIC. |
| 41 | SITC of 11KV G.I. Pin as per technical specifications and direction of EIC. |
| 42 | SITC of 11KV Pin Insulator as per technical specification & direction of EIC. |
| 43 | SITC of Top channel 100x50x6mm.2.8mtr. Long,2Nos. (9.2kg./mtr.) as per technical specifications and direction of EIC. |
| 44 | SITC of A/B switch mounting Channel 75x40x6mm.2x2.8mtr. Long(6.8kg/mtr.) |
| 45 | SITC of Bracing Channel 75x40x6mm.-2x3mtr. Long, (6.8Kg./mtr.) |
| 46 | SITC of Bracing angle 50x50x6mm.-2x4mtr. Long, (4.5Kg./mtr.) |
| 47 | SITC of Cantilever Channel for supporting A/B switch arm 75x40x6mm. 1.5mtr. Long,2Nos. (6.8Kg./mtr.) |
| 48 | SITC of Angle for Cantilever arrangement for A/B switch 50x50x6mm. 1.5mtr.,2Nos. (4.5Kg./mtr.) |
| 49 | SITC of 75x40x6 mm Channel 1.5 mtr. Long 1 No.(6.8 kg/mtr) for supporting of AB Switch handel. |
| 50 | SITC of 11KV Disc Insulator (T&C Type) as per technical specifications and direction of EIC. |
| 51 | SITC of 11KV H/W Fitting (T&C Type) as per technical specifications and direction of EIC. |
| 52 | SITC of 11KV A/B Switch 3Pole (400Amp) as per technical specifications and direction of EIC. |
| 53 | SITC of H.T Stay Set Complete as per technical specifications and direction of EIC. |
| 54 | SITC of H.T Stay Insulator as per technical specifications and direction of EIC. |
| 55 | SITC of H.T Stay Clamp as per technical specifications and direction of EIC. |
| 56 | SITC of G.I. Pipe Earthing, 40mm. Dia medium gauge 2.5mtr. Longas per technical specification & direction of EIC. |
| 57 | SITC of Earthing of Support (Coil type)as per technical specification & direction of EIC. |
| 58 | SITC of G.I. Nuts, bolt & Washer as per technical specification & direction of EIC. |
| 59 | SITC of Clamp for bracing Channel as per technical specifications and direction of EIC. |
| 60 | SITC of No. 6 G.I.wire for earthing as per technical specifications and direction of EIC. |
| 61 | SITC of 7/10 SWG Stay wire as per technical specifications and direction of EIC. |
| 62 | SITC of Fixing of Stay set with 0.5 cum cement concreting foundation 1:3:6 size (900mm×600mm×900mm) using 40 mm BHG metal with all labour and material except stay set,stay wire,stay insulator as per technical specifications and direction of EIC. |
| 63 | SITC of Concreting of support CC 1:4:8 using 40 mm BHG metal size 5×2×2 = 20 CFT = 0.570 CUM, Padding 900×600×150mm =0.081 as per technical specifications and direction of EIC. |
| 64 | SITC of Material for masonary work for earth pit as required and as per the direction of EIC. |
| 65 | SITC of Charcol, Salt etc. for earthing as required and as per the direction of EIC. |
| 66 | SITC of Sundries (Anticlimbing device, Paint. Danger Board ect.) as required and as per the direction of EIC. |
| 67 | Supply,Erection,testing & commissioning of 3PH 11 KV Line DP Cut-Point (Double Pole Structure on RS Joist Pole(except cost of pole) as per technical specification & direction of EIC. |
| 68 | SITC of 11KV G.I. Pin as per technical specifications and direction of EIC. |
| 69 | SITC of 11KV Pin Insulator as per technical specification & direction of EIC. |
| 70 | SITC of Top channel 100x50x6mm.2.8mtr. Long,Nos.(9.2kg./mtr.) as per technical specifications and direction of EIC. |
| 71 | SITC of Bracing Channel 75x40x6mm.-2x3mtr. Long, (6.8Kg./mtr.) as per technical specifications and direction of EIC. |
| 72 | SITC of Bracing angle 50x50x6mm.-2x4mtr. Long, (4.5Kg./mtr.) as per technical specifications and direction of EIC. |
| 73 | SITC of 11KV Disc Insulator (T&C Type) as per technical specifications and direction of EIC. |
| 74 | SITC of 11KV H/W Fitting (T&C Type) as per technical specifications and direction of EIC. |
| 75 | SITC of H.T Stay Set Complete as per technical specifications and direction of EIC. |
| 76 | SITC of Stay Insulatoras per technical specification & direction of EIC. |
| 77 | SITC of Stay clamp as per technical specification & direction of EIC. |
| 78 | SITC of Earthing of support (Coil Type)as per technical specification & direction of EIC. |
| 79 | SITC of G.I. Nuts, bolt & Washer as per technical specification & direction of EIC. |
| 80 | SITC of Clamp for bracing Channel as per technical specifications and direction of EIC. |
| 81 | SITC of 7/10 SWG G.I. Stay wireas per technical specifications and direction of EIC. |
| 82 | SITC of Fixing of Stay set with 0.5 cum cement concreting foundation 1:3:6 size (900mm×600mm×900mm) using 40 mm BHG metal with all labour and material except stay set,stay wire,stay insulator as per technical specifications and direction of EIC. |
| 83 | SITC of Concreting of support CC 1:4:8 using 40 mm BHG metal size 5×2×2 = 20 CFT = 0.570 CUM, Padding 900×600×150mm =0.081 as per technical specifications and direction of EIC. |
| 84 | SITC of Sundries (Anticlimbing device, Paint. Danger Board ect.) as required and as per the direction of EIC. |
| 85 | Supply,Stringing,testing & commissioning of11 KV line on 11mtr long RS Joist pole with 3Cx35 mm2 11KV XLPE Cable (except cost of pole)as per technical specifications and direction of EIC. |
| 86 | Supply,Stringing,testing & commissioning of55 Sqmm AAAC conductor for supporting 35 sqmm XLPE Cableas per technical specifications and direction of EIC. |
| 87 | Supply,installation,testing & commissioning of Outdoor Jointing kit for 3Cx35 mm2 11KV XLPE Cable as per technical specifications and direction of EIC. |
| 88 | Supply,Erection,testing & commissioning of Tapping Arrangement for XLPE cable on 11 KV Line(except cost of pole) as per technical specifications and direction of EIC. |
| 89 | SITC of 75x40x6mm. Channel for Straight Cross-arm(1.2mtr.X 4nos.) as per technical specifications and direction of EIC. |
| 90 | SITC of 11KV T&C Disc Insulator as per technical specifications and direction of EIC. |
| 91 | SITC of 11KV T&C Hardware Fitting as per technical specifications and direction of EIC. |
| 92 | SITC of 11KV Pin Insulator as per technical specification & direction of EIC. |
| 93 | SITC of 11KV G.i Pin as per technical specifications and direction of EIC. |
| 94 | SITC of H.T. Stay Set Complete as per technical specifications and direction of EIC. |
| 95 | SITC of HT Stay Insulator as per technical specifications and direction of EIC. |
| 96 | SITC of Stay clamp as per technical specification & direction of EIC. |
| 97 | SITC of 7/10 SWG Stay Wire as per technical specifications and direction of EIC. |
| 98 | SITC of G.I. Nuts, bolt & Washer as per technical specifications and direction of EIC. |
| 99 | SITC of Fixing of Stay set with 0.5 cum cement concreting foundation 1:3:6 size (900mm×600mm×900mm) using 40 mm BHG metal with all labour and material except stay set,stay wire,stay insulator as per technical specifications and direction of EIC. |
| 100 | SITC of Concreting of support CC 1:4:8 using 40 mm BHG metal size 5×2×2 = 20 CFT = 0.570 CUM, Padding 900×600×150mm =0.081 as per technical specifications and direction of EIC. |
| 101 | SITC of Earthing of support (Coil Type)as per technical specification & direction of EIC. |
| 102 | Supply,Stringing,testing & commissioning of 3x50+1x35mm2 LT Aerial bunched Cable (AB Cable)as per technical specification & direction of EIC. |
| 103 | Supply,installation,testing & commissioning of EYE hook for (XLPE Aerial bunched Cable) as per technical specification & direction of EIC. |
| 104 | Supply,installation,testing & commissioning ofPole clamp for EYE hook for (XLPE Aerial bunched Cable)as per technical specification & direction of EIC. |
| 105 | Supply,Erection,testing & commissioning of Accessories for 11/0.4kV DP mounted 63kVA S/S on 9 mtr long 300KG PSC Pole with double disc arrangement alongwith LT Distribution box with MCCB arrangement (except cost of pole and T/F) as per technical specification & direction of EIC. |
| 106 | SITC of Pressure Channel 100X50X6mm.2.8mtr.Long 2Nos. (9.2kg/mtr.) as per technical specification & direction of EIC. |
| 107 | SITC of Transformer mounting Channel 100x50x6mm. 2.8mtr.Long 2nos.(9.2kg./mtr.) as per technical specification & direction of EIC. |
| 108 | SITC of A/B switch and H.G. Fuse Mounting Channel 75x40x6mm. 2.8mtr.Long 4Nos.(6.8kg./mtr.) as per technical specification & direction of EIC. |
| 109 | SITC of Cantilever Channel for supporting A/B switch and HG fuse arm 75x40x6mm.1.5mtr.Long 4Nos. (6.8kg./mtr.) as per technical specification & direction of EIC. |
| 110 | SITC of Angle for cantilever arrangement for A/B switch & H.G. fuse 50x50x6mm. 1.5mtrEach , 4Nos. (4.5Kg/mtr.) as per technical specification & direction of EIC. |
| 111 | SITC of Transformer belting 50x50x6mm.angle - 2.8mtr. Long, 2Nos.(4.5Kg./mtr.)with side angle (Total 7 mtrs) as per technical specification & direction of EIC. |
| 112 | SITC of Angle for mounting L.T.Distribution box 50x50x6mm.-2.5mtr.Long,2Nos.(4.5Kg./mtr,) as per technical specification & direction of EIC. |
| 113 | SITC of 75x40x6 mm Channel 1.5 mtr. Long 1 No.(6.8 kg/mtr) for supporting of AB Switch handel as per technical specification & direction of EIC. |
| 114 | SITC of 11KV Disc Insulator (T & C) as per technical specification & direction of EIC. |
| 115 | SITC of 11KV H/W Fitting (T & C Type) as per technical specification & direction of EIC. |
| 116 | SITC of 11KV A/B Switch 3 pole as per technical specification & direction of EIC. |
| 117 | SITC of 11KV H/G Fuse 3pole as per technical specification & direction of EIC. |
| 118 | SITC of 11KV Lightning Arrestor as per technical specification & direction of EIC. |
| 119 | SITC of H.T.Stay set complete as per technical specification & direction of EIC. |
| 120 | SITC of HT Stay Insulator as per technical specifications and direction of EIC. |
| 121 | SITC of HT Stay Clamp as per technical specification & direction of EIC. |
| 122 | SITC of 7/10 SWG Staywire as per technical specification & direction of EIC. |
| 123 | SITC of G.I.Pipe Earthing, 40mm. Dia medium gauge 2.5mtr. Long as per technical specification & direction of EIC. |
| 124 | SITC of Earthing of support(Coil type) as per technical specification & direction of EIC. |
| 125 | SITC of No.6 G.I. wire for Earthing as per technical specification & direction of EIC. |
| 126 | SITC of Fixing of Stay set with 0.5 cum cement concreting foundation 1:3:6 size (900mm×600mm×900mm) using 40 mm BHG metal with all labour and material except stay set,stay wire,stay insulator as per technical specifications and direction of EIC. |
| 127 | SITC of Concreting of support CC 1:4:8 using 40 mm BHG metal size 5×2×2 = 20 CFT = 0.570 CUM, Padding 900×600×150mm =0.081 as per technical specifications and direction of EIC. |
| 128 | SITC of Material for masonary work for earth pit as required and as per the direction of EIC. |
| 129 | SITC of Charcoal, Salt etc. for earthing as required and as per the direction of EIC. |
| 130 | SITC of Clamp, Connector & Jumpering material as required and as per the direction of EIC. |
| 131 | SITC of G.I. .Bolts, Nuts & Washers as per technical specification & direction of EIC. |
| 132 | SITC of Sundries (Aluminium Binding tap, insulating tap, fencing metal spreading, Anticlimbing device, Paint. Danger Board ect.) as required and as per the direction of EIC. |
| 133 | SITC of L.T. distribution boxwith MCCB and busbar arrangement as per technical specification & direction of EIC. |
| 134 | SITC of L.T. 3½core PVC Cable:9mtrs.35mm.sq. for 25KVA @ 179.36/-mtrs.50mm.sq. for 63KVA @ 239.54/-mtr. 95mm.sq. for 100KVA @ 392.94/-mtr as per technical specification & direction of EIC. |
| 135 | SITC of Socket & other Cable Accessories as required and as per the direction of EIC. |
| 136 | Part B - Cost of Civil Work |
| 137 | Construction of boundary wall with barbed wire fencing type with provision of gate as required and as per the direction of EIC. |
| 138 | Metals spreadingas required and as per the direction of EIC. |