Tender For Estimate For Providing 100 Kva Dtr S/S For 38 Kw Cl Connection For Multi Consumer Complex Ev Charging Station At Guna Under Guna (T) D/C O&M Division Guna.Estimate No. & Date :- 21-905-120665-23-0002 Dt. 27.04.2023, W/O No. & Date :- Stc No. 18, Guna-Madhya Pradesh

Madhya Pradesh Madhya Kshetra Vidyut Vitaran Company Limited-MPMKVVCL has published Tender For Estimate For Providing 100 Kva Dtr S/S For 38 Kw Cl Connection For Multi Consumer Complex Ev Charging Station At Guna Under Guna (T) D/C O&M Division Guna.Estimate No. & Date :- 21-905-120665-23-0002 Dt. 27.04.2023, W/O No. & Date :- Stc No. 18. Submission Date for this Tender is 07-08-2023. Electrification Work Tenders in Guna Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38651778
Corrigendum : Tender For Estimate For Providing 100 Kva Dtr S/S For 38 Kw Cl Connection For Multi Consumer Complex Ev Charging Station At Guna Under Guna (T) D/C O&M Division Guna.Estimate No. & Date :- 21-905-120665-23-0002 Dt. 27.04.2023, W/O No. & Date :- Stc No. 18
Open Tender
Indian
Madhya Pradesh
Guna
07-08-2023

Tender Details

Estimate For Providing 100 Kva Dtr S / S For 38 Kw Cl Connection For Multi Consumer Complex Ev Charging Station At Guna Under Guna ( T ) D / C O&M Division Guna.Estimate No. & Date :- 21-905-120665-23-0002 Dt. 27.04.2023, W / O No. & Date :- Stc No. 188 Dt. 03.07.2023, O&M No. :- 12533 / 08 Dt. 30.06.2023, Erp No. :- 891567. 1 Provision :- Schedule A :- 100 Kv Dtr S / S On H-Beam - 01 No.Schedule B :- Lt Line On Ab Cable 2 Dtr 11 / 0.4 Kv Bis Ee-Level-2 100 Kva 3 Dtr 11 / 0.4 Kv Bis Ee-Level-2 100 Kva ( Handling & Installation Of Distribution Transformer ( Dtr ) On Dp, Tightening With Turn Buckles On Both Sides, Poles Clamping And Boting Of Base Jumpering On Ht Side ] 4 H-Beam 152X152 Mm., 37.1 Kg / Mtr 11 Mtr. Long 5 H-Beam 152X152 Mm., 37.1 Kg / Mtr 11 Mtr. Long Erection 6 11 Kv Ab Switch Polymer Type 400 Amp With Complete Fitting 7 Labour Charges For Fixing Of 11 Kv Ab Switch Polymer Type 400 Amp With Complete Fitting 8 11 Kv Composite Polymer Disc Insulators 9 11 Kv. D.O. Fuse Unit Polymer Type ( 1Set=3No. ) 10 Labour Charges For Fixing Of 11 Kv. D.O. Fuse Unit Polymer Type ( 1Set=3No. ) 11 11 Kv Polymer Lightening Arrestor Gapless Type ( 1Set=3No. ) 12 Labour Charges For Fixing Of 11 Kv Polymer Lightening Arrestor Gapless Type ( 1Set=3No. ) 13 11 Kv Strain Hardware ( T&C Type ) Fittings 14 Aaac Rabbit Conductor 0.05 Sq. Inch For Jumper 15 Aluminium Paint 16 Anti Climbing Device ( Barbed Wire ) Gs 2.24 Mm Dia ( 14 Swg ) 17 Labour Charges For Fixing Of Anti Climbing Device ( Barbed Wire ) Gs 2.24 Mm Dia ( 14 Swg ) 18 Bimetalic Clamp Distribution Transformers Bushing 19 Bi-Metallic Clamps Suitable For 12 Mm Dia Stud And 80 Sqmm Aaac 20 Concreting Of Stay @ 0.2 Cmt. Per Stay 21 Labour Charges For Concreting Of Stay @ 0.2 Cmt. Per Stay 22 Concreting Of Structures & Foundation ( 1:3:6 ) 23 Labour Charges For Concreting Of Structures & Foundation ( 1:3:6 ) 24 Dc Cross-Arms 8 Channel ( 100X50x6mm ) 25 Labour Charges For Fixing Of Dc Cross-Arms 8 Channel ( 100X50x6mm ) With Plates, 06 Nos. H / Ws, 06 Nos. Disc Insulators And Fixing Of Supporting Clamps On Both The Poles 26 D.O.Mounting Channel 75X40x6mm 27 Labour Charges For Fixing Of Do Channel With Support Clamp / Back Clamp 28 Dtr S / S Fencing ( 37 Feet ) Of 6 With On Ms Angle ( 50X50x6mm ) 7No, 7Height 29 Labour Charges For Dtr S / S Fencing ( 37 Feet ) Of 6 With On Ms Angle ( 50X50x6mm ) 7No, 7Height 30 Danger Board Enamelled 11 Kv 31 Labour Charges For Danger Board Enamelled 11 Kv 32 Double Gate ( 2No.-2.5X5x ) Set Of Ms Angle ( 25X25x4mm. ) With Mesh & Locking 33 Labour Charges For Double Gate ( 2No.-2.5X5x ) Set Of Ms Angle ( 25X25x4mm. ) With Mesh & Locking 34 Earthing Of Dtr As Per G1 Schedule G1 For Black Cotton Soil 35 H-Beam Clamps 65X8 Mm Flat 36 H-Beam Back Clamps 65X8 Mm Flat ( In Numbers ) 37 Lt Distribution Box With Isolator & Hrc Fuse -3 Phase 20-80 Amps, 100 Kva 38 Handling & Installation Of Dist. Box On Dp, Complete Wiring, Connecting Lt Cable On Bushing And Lt Feeders, 100 Kva 39 M.S. Nut And Bolts 40 Red Oxide Paint 41 Stay Wire 7 / 3.15 Mm ( 7 / 10 Swg ) 42 Stay Set Complete Without Stay Wire 16 Mm. ( Painted ) 43 Stay Set 16Mm Complete Without Stay Wire ( Painted ) A ) . Stay Pit Digging ( 16 Mm ) Size ( 5X2.5X5 ) = 62.50 Cu. Feetb ) . Stay Set Erection ( Complete With Binding Of Stay Wire At Eye Bolt, Stay Insulator And Anchor Rod ) 44 Stone Block / Pre Cast Block For Basepedding ( 450X450x75mm ) 45 Transformer Belting Set 50X50x6 Mm Angle With Two Cross Fixing Channel 46 Three Phase Static Energy Meters 20-80 Amps With L.S. & Tod Facility With Box 47 Three Phase Static Energy Meters 20-80 Amps With L.S. & Tod Facility With Box ( Labour Only For Installation Of Three Phase Meter On 12X16 Poly Carbonate / Wooden Board ( Excluding The Cost Of Board, Fixing The Board On The Wall, Screwing The Meter On The Board, Screwing Incoming & Outgoing Terminals Including ) 48 Transformer Mounting Channel ( 100X50x6 Mm ) 49 Labour Charges For Fixing Of Transformer Mounting Structure Complete With Base Channel, Supporting Clamps And Belting Of Fixing By Turn Buckles. 50 Xlpe 1 Core Unarmoured 70 Sqmm Aluminium Conductor 1100 Volts 51 Xlpe 1 Core Unarmoured 150 Sqmm Aluminium Conductor 1100 Volts 52 3 Ph Service Conn. Box With One Incmng Up To 35 Mm2 And 4No Outgng Up To16 Mm2 53 A.B. Cable Hanging Clamps / Tension Clamps ( Galvanized ) As Per Enclosed Drawing 54 Clamp For Neuteal For Ab Cable 55 Earthing Coil Of 115 Turns Of 50 Mm.Dia And 2.5 Mtr Lead Of 4.0 Mm G.I Wire 56 Lt Xlpe Cable Ab 3X120+1X16+ 1 X70 Sqmm.Al. Alloy Insulated Messenger Wire 1100 Volt 57 Stringing Of Lt Xlpe Cable Ab 3X120+1X16+ 1 X70 Sqmm.Al. Alloy Insulated Messenger Wire 1100 Volt 58 Piercing Connector Type-I, 1P / 3P ( Main 16-50Sqmm Tap-Off 16-50Sqmm 59 Piercing Connector Type-Ii ( Main 16-50 Sqmm Tap-Off 16-50 Sqmm ) 60 Suspension Clamp For Lt Ab Cable 61 Labour Charges For Suspension Clamp For Lt Ab Cable 62 Stay Clamp A Type 65X8 Mm Ms Flat Rs Joist 63 Gst @ 18%

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Jul-2023 Extended by Tender Date 01.08.2023 Date 31-07-2023
2 01-Aug-2023 Tender Extended Date 07-08-2023

Key Value

Document Fees
INR 236 /-
EMD
INR 3000.0 /-
Tender Value
INR 1.49 Lakhs /-

BOQ Items

Name of work :- Estimate for Providing 100 KVA DTR S/s for 38 KW CL Connection for Multi Consumer Complex EV Charging Station at Guna under Guna (T) D/C O&M Division Guna. Estimate No. & Date :- 21-905-120665-23-0002 dt. 27.04.2023, W/o No. & Date :- STC No. 188 dt. 03.07.2023, O&M No. :- 12533/08 dt. 30.06.2023, ERP No. :- 891567
Sl. No. Item Description
1Provision :- Schedule A :- 100 KV DTR S/s on H-Beam - 01 No. Schedule B :- LT Line on AB Cable
2DTR 11/0.4 KV BIS EE-Level-2 100 KVA
3DTR 11/0.4 KV BIS EE-Level-2 100 KVA (Handling & Installation of Distribution Transformer (DTR) on DP, tightening with Turn buckles on both sides, poles clamping and boting of base jumpering on HT Side]
4H-Beam 152x152 MM., 37.1 KG/Mtr 11 Mtr. Long
5H-Beam 152x152 MM., 37.1 KG/Mtr 11 Mtr. Long Erection
611 KV AB Switch Polymer type 400 Amp with complete fitting
7Labour Charges for Fixing of 11 KV AB Switch Polymer type 400 Amp with complete fitting
811 KV Composite Polymer Disc insulators
911 Kv. D.O. fuse Unit Polymer type (1Set=3No.)
10Labour charges for Fixing of 11 Kv. D.O. fuse Unit Polymer type (1Set=3No.)
1111 KV Polymer Lightening arrestor Gapless type (1Set=3No.)
12Labour charges for Fixing of 11 KV Polymer Lightening arrestor Gapless type (1Set=3No.)
1311 KV Strain Hardware (T&C type) Fittings
14AAAC Rabbit Conductor 0.05 Sq. inch for Jumper
15Aluminium Paint
16Anti climbing device (Barbed Wire) GS 2.24 MM Dia (14 SWG)
17Labour charges for Fixing of Anti climbing device (Barbed Wire) GS 2.24 MM Dia (14 SWG)
18Bimetalic clamp Distribution transformers Bushing
19Bi-metallic Clamps Suitable for 12 MM Dia stud and 80 Sqmm AAAC
20Concreting of stay @ 0.2 Cmt. per stay
21Labour charges for Concreting of stay @ 0.2 Cmt. per stay
22Concreting of Structures & Foundation (1:3:6)
23Labour Charges for Concreting of Structures & Foundation (1:3:6)
24DC Cross-arms 8" Channel (100x50x6MM)
25Labour Charges for Fixing of DC Cross-arms 8" Channel (100x50x6MM) with Plates, 06 Nos. H/Ws, 06 Nos. Disc Insulators and fixing of Supporting clamps on both the poles
26D.O.Mounting channel 75x40x6mm
27Labour Charges for Fixing of DO Channel with Support clamp/Back Clamp
28DTR S/s fencing (37 feet) of 6" with on MS Angle (50x50x6mm) 7No, 7"Height
29Labour Charges for DTR S/s fencing (37 feet) of 6" with on MS Angle (50x50x6mm) 7No, 7"Height
30Danger Board Enamelled 11 KV
31Labour charges for Danger Board Enamelled 11 KV
32Double Gate (2No.-2.5"x5x) Set of MS angle (25x25x4mm.) with Mesh & locking
33Labour charges for Double Gate (2No.-2.5"x5x) Set of MS angle (25x25x4mm.) with Mesh & locking
34Earthing of DTR As per G1 schedule G1 for Black cotton soil
35H-Beam clamps 65x8 MM Flat
36H-Beam Back Clamps 65x8 MM Flat (in Numbers)
37LT Distribution box with Isolator & HRC Fuse -3 Phase 20-80 amps, 100 KVA
38Handling & Installation of Dist. Box on DP, Complete wiring, Connecting LT Cable on Bushing and LT Feeders, 100 KVA
39M.S. Nut and bolts
40Red oxide paint
41Stay wire 7/3.15 mm (7/10 SWG)
42Stay set complete without Stay wire 16 mm. (Painted)
43Stay set 16mm Complete without stay wire (painted) a). Stay Pit Digging (16 MM ) Size (5"x2.5"x5")= 62.50 Cu. Feet b). Stay Set erection ( Complete with Binding of Stay Wire at eye Bolt, Stay insulator and Anchor Rod)
44Stone Block/Pre cast block for base pedding (450X450X75MM)
45Transformer Belting set 50x50x6 MM Angle with Two Cross Fixing Channel
46Three phase static Energy Meters 20-80 Amps With L.S. & TOD Facility with box
47Three phase static Energy Meters 20-80 Amps With L.S. & TOD Facility with box (Labour only for Installation of three phase meter on 12""x16"" Poly Carbonate/Wooden board (Excluding the cost of board,fixing the board on the wall, Screwing the meter on the board, Screwing incoming & Outgoing terminals including)
48Transformer Mounting Channel (100x50x6 MM)
49Labour Charges for Fixing of Transformer Mounting Structure Complete With base Channel, Supporting Clamps and Belting of Fixing by turn buckles.
50XLPE 1 core unarmoured 70 sqmm Aluminium conductor 1100 Volts
51XLPE 1 core unarmoured 150 sqmm Aluminium conductor 1100 Volts
523 Ph Service conn. Box with one incmng up to 35 mm2 and 4no outgng up to16 mm2
53A.B. Cable hanging Clamps/Tension Clamps (Galvanized) as Per Enclosed Drawing
54Clamp for Neuteal for AB Cable
55EARTHING COIL OF 115 TURNS OF 50 MM.DIA AND 2.5 MTR LEAD OF 4.0 MM G.I WIRE
56LT XLPE Cable AB 3X120+1X16+ 1 X70 Sqmm.al. alloy insulated Messenger wire 1100 Volt
57Stringing of LT XLPE Cable AB 3X120+1X16+ 1 X70 Sqmm.al. alloy insulated Messenger wire 1100 Volt
58PIERCING CONNECTOR TYPE-I, 1P/3P (MAIN 16-50SQMM TAP-OFF 16-50SQMM
59PIERCING CONNECTOR TYPE-II (MAIN 16-50 SQMM TAP-OFF 16-50 SQMM)
60Suspension Clamp for LT AB Cable
61Labour charges for Suspension Clamp for LT AB Cable
62Stay Clamp A type 65x8 MM MS Flat RS Joist
63GST @ 18%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail