}

Tender For Annual Rate Contract For Rental Daq And Sensors For 12 Months, Manesar-Haryana

International Centre For Automotive Technology-ICAT has published Tender For Annual Rate Contract For Rental Daq And Sensors For 12 Months. Submission Date for this Tender is 04-08-2023. Strain Gauges Tenders in Manesar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

38647287
Tender For Annual Rate Contract For Rental Daq And Sensors For 12 Months
Open Tender
Indian
Haryana
Manesar
04-08-2023

Tender Details

Tender For Annual Rate Contract For Rental Daq And Sensors For 12 Months. 1 Accelerometer Single Axis With Cables Any Make Any Model Dc Type 10G , 50 G , 100 G ( Frequency Range 2000 Hz ) 2 Nos Preferably Pcb Make. Accelerometer Should Compatible With E-Daq & Any Other Data Logger. It Should Have Accuracy Of 0.5 % Of Full Scale. 2 Accelerometer Tri Axial With Cables Any Make Any Model Dc Type 10G , 50 G , 100 G ( Frequency Range 2000 Hz ) 2 Nos Preferably Pcb Make. Accelerometer Should Compatible With E-Daq & Any Other Data Logger. It Should Have Accuracy Of 0.5 % Of Full Scale. 3 Accelerometer Single Axis With Cables Any Make Any Model Icp Type 10G , 50 G , 100 G ( Frequency Range 2000 Hz ) 2 Nos Preferably Pcb Make. Accelerometer Should Compatible With E-Daq & Any Other Data Logger. It Should Have Accuracy Of 0.5 % Of Full Scale. 4 Accelerometer Tri Axial With Cables Any Make Any Model Icp Type 10G , 50 G , 100 G ( Frequency Range 2000 Hz ) 2 Nos Preferably Pcb Make. Accelerometer Should Compatible With E-Daq & Any Other Data Logger. It Should Have Accuracy Of 0.5 % Of Full Scale. 5 Lvdt Any Make Any Model 100 / 300 / 250 Mm 4 Nos Lvdt Should Compatible With Edaq .It Should Have Accuracy Of 0.5 % Of Full Scale 6 Thermocouple Module Any Make Any Model 4 Channel 1 No Module Should Be Can Based & It Should Compatible With E-Daq Data Logger .Dbc File Of Each Module Should Be Provided At The Time Of Delivery 7 Thermocouple Module Any Make Any Model 8 Channel 1 No Module Should Be Can Based & It Should Compatible With E-Daq Data Logger .Dbc File Of Each Module Should Be Provided At The Time Of Delivery 8 Thermocouple Module Any Make Any Model 16 Channel 1 No Module Should Be Can Based & It Should Compatible With E-Daq Data Logger .Dbc File Of Each Module Should Be Provided At The Time Of Delivery. 9 Thermocouple Module Any Make Any Model 32 Channel 1 No Module Should Be Can Based & It Should Compatible With E-Daq Data Logger .Dbc File Of Each Module Should Be Provided At The Time Of Delivery 10 Thermocouple Module Any Make Any Model 48 Channel 1 No Module Should Be Can Based & It Should Compatible With E-Daq Data Logger .Dbc File Of Each Module Should Be Provided At The Time Of Delivery 11 Thermocouple Module Any Make Any Model 64 Channel 1 No Module Should Be Can Based & It Should Compatible With E-Daq Data Logger .Dbc File Of Each Module Should Be Provided At The Time Of Delivery 12 Data Acquisition System ( Preferred System From Hbk, Imc, Dewetron ) Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require D Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require ( Edaq, Cansas Modules , Uni8, Bridge Module ) 16 Channels 1 No Data Acquisition System Should Be Compatible To Measure Parameters Such As Strain ( 350 Ohm, 120 Ohm ) , Accelerations, Voltage. Distributed And Modular Data Acquisition System In Split Of 8, 16 Channels And Either Stackable With Existing System Or Should Synchronies With The Existing Data Logger As And When Required. Should Have Can Compatibility So As To Map Vehicle Level Can Parameters As And When Required. 13 Data Acquisition System ( Preferred System From Hbk, Imc, Dewetron ) Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require D Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require ( Edaq, Cansas Modules , Uni8, Bridge Module ) 32 Channels 1 No Data Acquisition System Should Be Compatible To Measure Parameters Such As Strain ( 350 Ohm, 120 Ohm ) , Accelerations, Voltage. Distributed And Modular Data Acquisition System In Split Of 8, 16 Channels And Either Stackable With Existing System Or Should Synchronies With The Existing Data Logger As And When Required. Should Have Can Compatibility So As To Map Vehicle Level Can Parameters As And When Required. 14 Data Acquisition System ( Preferred System From Hbk, Imc, Dewetron ) Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require D Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require ( Edaq, Cansas Modules , Uni8, Bridge Module ) 64 Channels 1 No Data Acquisition System Should Be Compatible To Measure Parameters Such As Strain ( 350 Ohm, 120 Ohm ) , Accelerations, Voltage. Distributed And Modular Data Acquisition System In Split Of 8, 16 Channels And Either Stackable With Existing System Or Should Synchronies With The Existing Data Logger As And When Required. Should Have Can Compatibility So As To Map Vehicle Level Can Parameters As And When Required. 15 Data Acquisition System ( Preferred System From Hbk, Imc, Dewetron ) Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require D Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require ( Edaq, Cansas Modules , Uni8, Bridge Module ) 48 Channels 1 No Data Acquisition System Should Be Compatible To Measure Parameters Such As Strain ( 350 Ohm, 120 Ohm ) , Accelerations, Voltage. Distributed And Modular Data Acquisition System In Split Of 8, 16 Channels And Either Stackable With Existing System Or Should Synchronies With The Existing Data Logger As And When Required. Should Have Can Compatibility So As To Map Vehicle Level Can Parameters As And When Required. 16 Data Acquisition System ( Preferred System From Hbk, Imc, Dewetron ) Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require D Any System Compati Ble With Existing Daq Or Matchin G The Test Require Ment As An When Require ( Edaq, Cansas Modules , Uni8, Bridge Module ) 96 Channels 1 No Data Acquisition System Should Be Compatible To Measure Parameters Such As Strain ( 350 Ohm, 120 Ohm ) , Accelerations, Voltage. Distributed And Modular Data Acquisition System In Split Of 8, 16 Channels And Either Stackable With Existing System Or Should Synchronies With The Existing Data Logger As And When Required. Should Have Can Compatibility So As To Map Vehicle Level Can Parameters As And When Required. 17 Pressure Transducer Any Make ( Pl Specify ) Any Make ( Pl Specify ) 0-50 Bar , 0-100 Bar , 0-25 Bar, 0-500 Bar 2 Nos It Should Compatible With Data Logger & Have Output In Voltage .Accuracy Should Be In +- 0.5 % Of F.S. 18 Flow Meter Any Make Any Make Coolant Flow Meter ( 0-50, 0-100, 0-200 Lpm ) 1 Nos It Should Compatible With Data Logger & Have Output In Pulse Or Voltage . 19 Fuel Flow Meter Any Make ( Preffere D – Kistler / Onosok Ki / Avl / Peisler ) Any Make Range 20-150 Lpm, 1 % Of Reading Accuracy 1 Nos Compatible With Diesel & Gasoline Engine Vehicle. Should Have Can Output And Should Be Compatible With Existing Logger 20 Rpm Sensor Any Make Any Make Upto 12000 Rpm 2 Nos With Pulse Output 21 Current Clamp Meter With Analog Output Any Make Any Make Measure Dc As Well As Ac Current. Range Upto 2000 Ampere 1 Nos It Should Have Analog Output Of 5- 10 V . 22 Strain Gauge Installation With Gauge Hbm / S Howa Hbm / S Howa Quarter Linear Gauge ( 1.5 Mm, 3Mm , 6Mm ) 5 Nos 23 Strain Gauge Installation With Gauge ( Full Bridge ) ( Torsion , Bending ) Hbm / S Howa Hbm / S Howa Full Bridge 5 Nos 24 Strain Gauge Rosette Installation With Gauge Hbm / S Howa Hbm / S Howa 45 Deg Or 60 Deg 5 Nos 25 Torque Telemetry Any Make Any Make Torque Measurement 1 Nos Telemetry System Should Be With Voltage Output Corresponding To Measured Parameters. 26 Slip Ring Any Make Any Make Torque Measurement 1 Nos Slip Ring Should Compatible With Edaq Data Logger. 27 Strain Smart Module ( Signal Conditioner ) Hbk Hbk 120 Ohm Or 350 Ohm 5 Nos Modules Should Compatible With Edaq 28 Engineer Support Charges For Rlda 1 Day Engineer Should Have Experience In The Field Of Validation & Testing, Rlda. Capable Of Handling The Sensor & Daq Individually.

Key Value

Document Fees
Refer document
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail