| 1 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 2 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishing and reinforcement-1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stoneaggregate 20 mm nominal size) |
| 3 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars,piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 4 | Centering shuttering including struttings, propping etc. and removal of form work for:a. Lintels, beams, plinth beams, girders, bressumers andcantilevers with wooden plank |
| 5 | Centering shuttering including struttings, propping etc. and removal of form work for:b Suspended floors, roofs, landings, balconies and access platform with timber planks |
| 6 | Centering shuttering including struttings, propping etc. and removal of form work for: C Columns, Pillars, Piers, Abutments, Posts and Struts withwooden plank |
| 7 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 8 | 12 mm cement plaster of mix : In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 9 | 15 mm cement plaster on the rough side of single or half brick wall of mix: Cement mortar 1:4 (1 cement : 4 fine sand) |
| 10 | 6 mm cement plaster of mix :Cement mortar 1:4 (1 cement : 4 fine sand) |
| 11 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622 - 2017, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with greycement slurry @ 3.3 kg/ sqm including grouting the jointwith white cement & matching pigments etc. complete Soluble Salt Stainfree vitrified tilesSize of tile 60x60 cm |
| 12 | Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade complete. |
| 13 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622 - 2017, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement: 4 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 14 | Providing wood work in frames of doors, windows,clerestory windows and other frames, wroughtframed and fixed in position :Karai wood |
| 15 | Providing and fixing panelled / or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked bright finished /black enamelled M.S butt hinges with necessary screws excluding panelling and or glazing, which will be paid for separately but including the woodenbeading of 20 × 12 mm for fixing panelling and or glazing as per direction of Engineer-In-Charge.Gamair Wood 35 mm thick shutters |
| 16 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of TestCertificate issued by the Manufacturer] : New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture |
| 18 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade[Payment shall be made after submission of TestCertificate issued by the Manufacturer] : New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 19 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 20 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sectionsand other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up ofgaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleatangle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction ofEngineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :- For fixed portion of approved quality:- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 21 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required includingthe cost of EPDM rubber / neoprene gasket required ( Fittings shall be paid for separately ):- Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 22 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition etc. with EPDM rubber / neoprene gasket etc.complete as per architectural drawing and the direction of Engineer-in-charge (Cost of snap beading shall be paid in basic item) :- With float glass panes of 4.0 mm thickness ( weight notless than 10.0 kg / sqm ) |
| 23 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer usingsteel etc. complete as required:-In grating, frames, guard bar, railing, brackets, gates and similar works, all complete. |
| 24 | 30mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a UPVC profile section of size 30mm x 60mm and wall thickness 2mm ± 0.2mm with inbuilt decorative moulding edging on one side. The styles and rails with plastic brackets of size 75×220 mm mitred and welded at the corners. The styles of the shutter reinforced by inserting galvanised MS tube of size 25×20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of \"H\" Section, a UPVC profile section of size 30×100 mm and 2 mm ± 0.2 mm wall thickness welded to the shutter style with a UPVC profile section single panel of size not less than 620 mm, having overall thickness of 20 mm and 1 mm ± 0.1 mm wall thickness with 20 mm panel beading of suitable size/Glass (4 mm thick plain glass)/ louver section, louver frame of suitable size, complete as per manufacturer\"s specification and direction of Engineer-In-Charge. (for W.C. and Bathroom door shutter). |
| 25 | Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm,made out of extruded 5mm rigid PVC foam sheetmitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19×19mm MS square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame . The door frame to be fixed to the wall usuing MSscrews of 65/100 mm size complete as per manufacturers\" specification and direction of Engineer-In-Charge. |
| 26 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 27 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 28 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width78mm and effective height of 88mm, weighing not less than 190gms. |
| 29 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing notless than 106 gms. |
| 30 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete |
| 31 | Providing and fixing brass stop cock of approvedquality :15 mm nominal bore |
| 32 | Providing and fixing brass bib cock of approvedquality :15 mm nominal bore |
| 33 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushingcistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 34 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type Aincluding jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion Single socketed pipe - 75 mm OD : |
| 35 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type Aincluding jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansionSingle socketed pipe - 110 mm OD |
| 36 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:(a) Coupler 75 mm |
| 37 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:(a) Coupler 110mm |
| 38 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:( b)Bend 87.5\" 75 mm |
| 39 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:( b)Bend 87.5\" 110 mm |
| 40 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: (c)Single equal tee without door 75x75x75 mm |
| 41 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: (c)Single equal tee without doo 110x110x110mm |
| 42 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: (d) Single equal tee with door 110x110x110mm |
| 43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. i.15 mm nominal outer dia .Pipes. |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. ii. 25 mm nominal outer dia .Pipes. |
| 45 | Demolishing brick work including stacking of serviceable materials and disposal of unserviceable materials with all lifts and upto a lead of 50m etc. complete as per direction of the Engineer- in-charge:-In cement mortar. |