}

Tender Document For Supply, Installation, Testing Of Equipment For Environmental Lab At Civil Department, SANGLI-Maharashtra

Walchand College Of Engineering has published Tender Document For Supply, Installation, Testing Of Equipment For Environmental Lab At Civil Department. Submission Date for this Tender is 18-07-2023. Fluid Mechanics Equipment Tenders in SANGLI Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

38600543
Tender Document For Supply, Installation, Testing Of Equipment For Environmental Lab At Civil Department
Open Tender
Indian
Maharashtra
SANGLI
18-07-2023

Tender Details

Tender Document For Supply, Installation, Testing Of Equipment For Environmental Lab At Civil Department-1 Atomic Absorption Spectrophotometer with Software Optics: Double Beam (Chopper Mirror); Graphite furnace; Monochromator: Czerny-Turner configuration; Wavelength Range: 190nm - 900nm; Wavelength Accuracy: ±0.25nm; Wavelength Repeatability: 0.15nm; Slit: 0.2 nm, 0.7 nm Manual Setting; Frequency: 100 Hz; Power: AC220V, 230V, 50/60Hz, 300VA; Burner Head of 10cm slot. Nebulizer assembly. Deuterium lamp. Drain tube PTFE tube for sample suction. Hose assembly for Air. Hose assembly for C2H2. Hose band RS-232C connection cable (9P-9P). AC cable for 220, 230V ; Air Compressor, with Hollow Cathode Lamps and Standard Solutions for the elements - Copper, Zinc, Nickel, Manganese, Iron, Lead, Cadmium, Chromium, Cobalt, Boron, Tin , Lithium, Selenium , Mercury , Aluminum, and Arsenic. 2 Sound Level Meter – SLM400-KIT, Measurement Ranges: Low: 35 to 100dB; High: 65 to 130dB, Bandwidth: 31.5Hz to 8kHz, Resolution: 0.1dB, Accuracy: ±1.5dB Standards: Meets Type 2 ANSI S1.4-1983; IEC 60651, EN60651, Frequency Weighting: A and C (selectable), Response Time Fast: 125ms With Power battery Software & data logger 3 Prana Real-Time Air Quality Monitor: Measures PM1, PM2.5, PM10, and IAQ parameters Advanced Sensors: TVOCs, HCHO, CO, O3, and CO2 Historic AQI Data: Analyze the past air quality graph on the screen USB Power Supply: Smart-edge air monitoring device with type-C USB cable, No battery inbuilt Connectivity: No Internet, No WiFi Prana Air Sensible Indoor Air Quality Monitor - IAQ detects the presence of PM1, PM2.5, PM10, CO, CO2, O3, TVOC, and HCHO. It gives the real-time and historic AQI graph on the screen. Type-C USB charging type is supported by the monitor, with inbuilt battery with software. 4 Digital vibration meter: measuring Acceleration, Velocity, Displacement, Crest Factor, Bearing condition in PK, PK-PK, RMS, Audio signal. Color display with ISO10816 on screen indicators, memory of 100 time stamped entries with PCconnectivity, sturdy body, 20 hours battery life, rechargeable battery, 2 years warranty. 5 Portable Flue Gas Analyzer FEM 7 Microprocessor based Portable Flue Gas Analyzer with standard accessories, and digital display with self-calibration capability; built in memory and RS 232 interface for temperature measurement and following: Gas Sensor/ Range Resolution O2 Electrochemical 0-25% 0.1 % CO Electrochemical 0-2000 PPM 1PPM CO2 Calculated 0-25% 0.1% Nox Electrochemical 0-2000 PPM 1PPM So2 Electrochemical 0-2000 PPM 1PPM HC NDIR 0-100 % V/V 0.1% usable at automobile exhaust analysis, including supplementary accessories such as Printer, Case, Gas pump, Condense trap, Filter, User manual , Calibration certificate, Battery / charger, standard Gas probes etc. with 3 years warranty 6 Digi-Sense Environmental Meter; Wind Speed, Humidity, Temperature, and Light Meter Max Air Velocity (ft/min) 5910; Min Air Velocity (ft/min)80 Air Velocity Resolution1 ft/min, 0.1 m/s, 0.1 km/hr, 0.1 mph, 0.1 knots; Air Velocity Accuracy≤ 20 m/s: ± 3% F.S.; > 20 m/s: ± 4% F.S. Number Of Temperature Channels1;Types Of Probes Accepted Type K thermocouple with mini-connector; Min Temperature (° C) 0 Max Temperature (° C) 50;Temperature Accuracy Internal sensor: ±2.5°F (±1.2°C); External sensor: ± (1% of reading +2°F) from -148 to 2372°F or ± (1% of reading + 1°C) from -100 to 1300°C; Temperature Resolution 0.1°F (0.1°C); Max RH (%) 95; Min RH (%) 10 RH Resolution 0.1% RH; H Accuracy< 70% RH: ±4% RH; ≥ 70% RH: ± (4% or reading + 1.2% RH); Data Logging Battery: One 9 V battery 7 Stack Monitoring Kit Envirotech Model VSS3 (Equipment specially to monitor Dioxins &amp; Furan emissions) with Normal Stack Monitoring facilities like PM, Sox, NOx etc. Stack temperature Range: Ambient to 600 deg C read on a Digital Pyrometer, Stack Velocity Range :3 to 60 m/sec, Thermocouple: T/C sensor in SS 304 casing, length of insertion: 1 m with 2m long cable. Manometer: Digital with 0-1060 mm of H2O range Pitot Tube: Calibrated S-type fabricated -SS 304, 1m long; Particulate Sampling: 0 –30 lpm collection on thimble type filter up to 0.3micron rating Gaseous Sampling: 0 – 3 lpm collection in a set of Borosilicate glass impingers Rotameter: Acrylic body with 2% FSD accuracy, 0 – 30 lpm for PM and 0-3 lpm for GAS. Sampling Probe: 1m long SS tube with inside lining of Teflon & provision for controlled at 120 deg C heating Filter Holder: Glass filter holder with heating provision suitable to hold either cellulose filtration thimble (size 28mm lD X 100mm long) or glass fibre thimble (size 19mm lD X 90mm long). Nozzles: A set of 5 glass nozzles Digital Clock: 0-60 minutes, 1 second readout with start and stop switches Temp. Controller: Digital type temperature controller Dry Gas Meter: Range 0 to 60 LPM connected to SPM line Sampling Train: 4 Nos. of 275 ml cap glass impinger, 1 No. condenser glass coil, 1 No. moisture bottle 750 ml & 1 No. cartridge tube accommodated in separate ice tray with instrument panel with a provision to cool down flue gas temperature. Vacuum Pump: Monoblock Rotary Vane type, oil free, 0.5 HP single phase motor (230V) with more than 50 lpm free flow capacity. DESIRABLE ACCESSORIES, SPARES &amp; CONSUMABLES FOR SMK I. Heated Probe system suitable for use in high moisture conditions II. Orsat Apparatus III. Fluorine Kit IV. Cyclone Assembly ENVIROTECH V. Glass NOX Collection Assembly VI. A Reagent Kit for Sampling and Analysis Consisting of essential reagents for sampling SO 2 and NOx, Tools, essential accessories and standard methods) for SOURCE EMISSION MONITORING - approximately 80 Monitoring VII. Extension Vacuum Hose Pipe metal braided 10mtr. long VIII. Carbon Monoxide Bottle IX. Filtration thimbles Whatman make in a sealed packet of 25 thimbles:  Cellulose, size 28 x 100mm, (suitable up to 150oC)  Glass microfiber, size 19 x 90mm (suitable up to 500oC) X. Glass Impinger 240 ml. capacity (SPM) PVC end XI. Glass Impinger 120 ml. capacity PVC end XII. Glass Impinger 120 ml. capacity (Silica gel) PVC end 8 CO Analyzer with internal pump - Ecotech Pty Ltd, Australia; Model: Serinus 30; based on Non Dispersive Infra -Red-Gas Filter Correlation methodology Range:0 to 200 ppm (auto ranging) Concentration units: mg/m3, μg/m3, ng/m3, ppm, ppb or ppt Noise:< 0.02 ppm or 0.2 % of concentration reading whichever is greater Lower detectable limit:< 0.04 ppm Linearity:< 1 % of full scale (0 - 50 ppm) Precision:0.1 ppm or 0.1 % of reading whichever is greater Zero drift:24 hours: < 0.1 ppm Span drift:7 days: < 0.1 ppm Response time:7 days: < 0.5 % of reading or 0.1 ppm whichever is greater STP reference:60 seconds to 95 %0 °C, 20 °C, 25 °C at 101.3 kPa Sample flow rate:1000 cc/min Temperature range:0 to 40 °C Power:100 - 240 VAC, 50 - 60 Hz (auto ranging Power consumption:260 VA (max at start-up)150 VA (nominal) Dimensions:429 x 175 x 638 mm Rack Spacing:3.5 RU Weight:) 17.8 kg 1.Calibration Gas Cylinder for CO with Regulator and accessories 1 set 2 47mm Filters, 5μm size 1 Pack 3. Systems Integration, Testing, Installation, &amp; Commissioning at site 9 Heavy Metal Sampler Envirotech Model APM 586 Filter Holder and Filter Media Filter holder assembly is designed for convenient installation and removal of 47 mm diameter EPM 2000 filter discs Sample Volume: Air flow rate is maintained at 3 LPM with the help of a critical orifice 0-99999.99 h Time Totalizer to record the instrument run time. 0.016 m3/h to 2.5 m3/h Diaphragm Gas Meter to record the total volume of air sampled. Power Requirements: 15 Volt AC operated. 8-10 h battery backup available. Dimensions (cm) : 30 cm (W) X 20 cm (D) X 80 cm (H)Enter your text here... Weight: 7.8 Kg Extra SPARES & CONSUMABLES FOR APM 586 (Useable with APM 586) i) EPM 2000 Filter Paper for Heavy Metals Sampling 47 mm dia in a sealed packet of 100 discs Imported ‘Whatman’ make 1 pack ii) Filter Carrier with Cover 1 10 Ultrafine PM1 Particulate Sampler Envirotech model APM 577M Particle Size: Omni-directional air inlet with PM1 separation through an impactor designed and perfected by IIT Kanpur Sampling Rate: Constant sampling rate of 10 liter per minute, unaffected by voltage fluctuation maintained by critical orifice system Filter Media: Filter holder designed to accept any standard 47 mm diameter PTFE Sample Volume: Dry Gas meter records the total air volume sampled Automatic sampling control: 24hour programmable timer is provided to automatically start and shut off sampler as per requirement Power Requirement: Single phase AC 220 volts, 50 Hertz supply. Sampler unaffected by +/- 10% fluctuation in supply voltage. Extra SPARES & CONSUMABLES (Useable with APM 577 M) PTFE filter with identification number for each filter, Pore Size 2μm, dia 46.2mm with PP ring supported. Suitable for Monitoring of Pm 2.5 dust. Sealed packet of 50 discs a) Imported ‘Whatman’ make b) Indigenous make ii)Filter carrier with cover iii) Whatman GF/A Grade Glass Microfiber filters 25 mm diameter in a sealed packet of 100 discs for Measurement of particulates iv) Silicon Oil in 100 ml bottle 11 Serinus 10 Ozone analyzer Ranges: Auto ranging 0-20ppm (Analogue ranges 0-50 ppb to 0-20 ppm) Concentration display: User selectable mg/m3, μg/m3, ppm, ppb, ppt Noise: < 0.25 ppb Lower detectable limit: < 0.5 ppb Linearity: < 1% of full scale Precision: 0.5 ppb at < 100ppb otherwise 0.2% of reading whichever is greater Zero drift: 24 hours: < 0.3 ppb; 7 days: < 0.3 ppb Span drift: 7 days: < 0.5% of reading Response time: 30 seconds to 95% STP reference: 0°C, 20°C, 25°C at 101.3 kPa Sample flow rate: 500 cc/min (optional 750 cc/min) Temperature range: 0 - 40°C Power: 198-264 VAC 47-63 Hz 255VA (max startup), 180 VA (nominal) Dimensions: 3.5 RU, 429 x 175 x 638 mm Weight: 17.2 kg Communications:USB, RS 232, TCP/IP, Bluetooth Data logging: Removable USB flash memory drive that stores instantaneous data as well as average data from 1 minute up to 24 hours. 1 minute data can be stored for 10 years 1. 47mm Filters, 5μm size 1 Pack 2. Systems Integration, Testing, Installation, &amp; Commissioning at site 1 12 AERMOD upgrade AERMOD View v11.2 Single User Academic LicenseSampling Rate: Constant sampling rate of 10 liter per minute, unaffected by voltage fluctuation maintained by critical orifice system Filter Media: Filter holder designed to accept any standard 47 mm diameter PTFE Sample Volume: Dry Gas meter records the total air volume sampled Automatic sampling control: 24hour programmable timer is provided to automatically start and shut off sampler as per requirement Power Requirement: Single phase AC 220 volts, 50 Hertz supply. Sampler unaffected by +/- 10% fluctuation in supply voltage. Extra SPARES & CONSUMABLES (Useable with APM 577 M) PTFE filter with identification number for each filter, Pore Size 2μm, dia 46.2mm with PP ring supported. Suitable for Monitoring of Pm 2.5 dust. Sealed packet of 50 discs a) Imported ‘Whatman’ make b) Indigenous make ii)Filter carrier with cover iii) Whatman GF/A Grade Glass Microfiber filters 25 mm diameter in a sealed packet of 100 discs for Measurement of particulates iv) Silicon Oil in 100 ml bottle 11 Serinus 10 Ozone analyzer Ranges: Auto ranging 0-20ppm (Analogue ranges 0-50 ppb to 0-20 ppm) Concentration display: User selectable mg/m3, μg/m3, ppm, ppb, ppt Noise: < 0.25 ppb Lower detectable limit: < 0.5 ppb Linearity: < 1% of full scale Precision: 0.5 ppb at < 100ppb otherwise 0.2% of reading whichever is greater Zero drift: 24 hours: < 0.3 ppb; 7 days: < 0.3 ppb Span drift: 7 days: < 0.5% of reading Response time: 30 seconds to 95% STP reference: 0°C, 20°C, 25°C at 101.3 kPa Sample flow rate: 500 cc/min (optional 750 cc/min) Temperature range: 0 - 40°C Power: 198-264 VAC 47-63 Hz 255VA (max startup), 180 VA (nominal) Dimensions: 3.5 RU, 429 x 175 x 638 mm Weight: 17.2 kg Communications:USB, RS 232, TCP/IP, Bluetooth Data logging: Removable USB flash memory drive that stores instantaneous data as well as average data from 1 minute up to 24 hours. 1 minute data can be stored for 10 years 1. 47mm Filters, 5μm size 1 Pack 2. Systems Integration, Testing, Installation, &amp; Commissioning at site 1 12 AERMOD upgrade AERMOD View v11.2 Single User Academic License

Key Value

Document Fees
INR 500 /-
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail