Tender For Estimate For Renovation Of Electrification Of Two Blocks Of S-Quarter In The Institute. 1 Wiring For Light Point / Fan Point / Exhaust Point / Call Bell Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit With Modular Switch, Modular Plate, Suitable Gi Box & Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable Etc As Required.A ) Groupc 2 P / F Of High Lumen22w Led6500k ( 4 Ft ) Wall Mounted Led Batten, Extruded Aluminum Heat Sink Provided For Efficient Heat Dissipation & Integrated Electronic Driver Complete In All Respects. The Specification Of The Luminaries Is As Follows:1 ) System Efficacy >100 Lm / W, Up To 40% Energy Saving With Same Lighting Level.2 ) Color Rendering ( Cri>80 ) 3 ) Input Volt Range140v - 270V Ac4 ) T Ambient ( Max ) 45 Deg C, Pf > 0.9 Thd < 20 %.5 ) Sdcm <5, Cri >80 Complete In All Respects. 3 P / F Of Bolt Round 15W Led 6500K Ip 65 Surface / Recess Mounted Round Shaped Led Down-Lighter With Durable Housing With Al Heat Sink With Diffuser To Give Glare Free Light With Removable Driver. Complete In All Respects. 4 Supplying & Fixing Following Modular Switch Of 16 Amp, Socket Outlet Of 3 Pin 16 Amp And Pvcbox Along With Modular Base & Cover Plate Of4 Module , 2 Module Switch 16A In Surface Including Connections Etc As Required. Complete The Job In All Respects. 5 Supplying & Fixing Following Modular Switch Of 10 Amp, Socket Outlet Of 3 Pin 10 Amp And Pvcbox Along With Modular Base & Cover Plate Of3 Module , 1 Module Switch 10A In Surface Including Connections Etc As Required. Complete The Job In All Respects. 6 Supplying & Fixingof 2 Way 5 / 6 A Switch In Existing Modular Plate . Complete In All Respects. 7 Supplying And Fixing 5A To 32 A Rating, 240 / 415 V, 10 Ka, “C”Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.A ) Single Pole. 8 Supplying And Fixing 40 A Rating, 240 / 415 V, 10Ka “C” Curve, Double Pole Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 9 Wiring For Circuit / Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 10 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire. 11 2 X 10 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 12 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) A ) 8 Way Double Door 13 P / F Of 400 Mm Sweep Swing Wall Fan, 120 Ribs Guard. Oscillation Degree : 60°, Speed: 1350 Rpm, Air Delivery: 72 Cmm , Thermal Overload Protector ( Top ) Helps In Protecting The Motor In Case Of Any High Voltage Fluctuation ; Guard: 120 Spokes , Noise Level: 63.2 Db ; Power Consumption: 50 W, Rated Voltage: 230 V, Rated Frequency: 50 Hz With 300 Watt % Step Regulator Complete In All Respects 14 P / F Of 150 Mm Sweep Heavy Duty Exhaust Fan, With Shutter ( Pvc Type ) In Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Complete In All Respects. 15 P / F Of 200 Mm Sweep Heavy Duty Exhaust Fan, With Shutter ( Pvc Type ) In Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. Complete In All Respects. 16 Supplying And Fixing Of Following Sizes Of Heavy Duty Class Pvcconduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required 32Mm 40 Mm 32 Mm 17 40 Mm 18 Sitc Of2000 Watt 50 Liters 5 Star Rating Geyser With Following Specifications : Input Voltage Range 170-240V Current Leakage Protection Device• Multi Functional Safety Valve• Non- Corrosive Storage Tank Thick Material Of Pure Copper.• High Precision Thermostat Control• Preset Thermal Output• High Working Pressure 0.8Mpa Ideal For High Rise Buildingvertical Mounting The Geyser Includes Bracket, Fasteners, Input And Output Pipes, Drain Pipe And Other Related Accessories. Complete In All Respects. 19 Supplying, Installation, Testing & Commissioning Of 1700Mm ×1700Mmindoor Panel Factory Assembled Dust & Vermin Proof Lt Cubical Type Compartmentalizedpanel Of 400A Tpn Aluminum Busbar ( 10Mm Thickness ) Panel ( Cpri Approved ) Fabricated Out Of2 Mm Thick Ms Sheet, 400 Mm Deepwith Locking Arrangement, Cable Alleys, Bus Bar Chamberetc Powder Coated Self Supported Suitable For 3 Phase 4 Wire, Ac Supply, I / C Supplying & Fixing Following Accessories As Detailed Below, I / C Bus Bars Connections / Inter Connections To Mccb Compartments , Arrangement For Cable Entry, Supports, End Terminations, 2 Nos. Earthing Stud Inter Connection With 25Mm X 5Mm Gi Strip ( Externally ) , Painting, Etc. Complete As Required.1. Tpn Al Busbar: 1 No2.P / F Of 4- Pole, 250 Amp. Mccb ( Adjustable Type ) Easy Pact Cvs, Lcu= 36Ka With With Ics = 100% Icu As Per Iec 60947-2, With Rotatory Handle : 1 No 3. Energy Meters : 12 Nos ( Hpl Make ) 4. Panel Compartments 12 Nos For Housing Of Energy Meters. 5. 40A Mcb Dp 10Ka C Curve In Each Compartment. : 12 Nos6. 3-Phase Multifunction Meter Mounted On Panel: 1 No ( Panel Should Be 1.5 Feetabovegroundincluding Iron Stand As Per Requirement & As And When Required ) 20 Supplying And Laying Of One Xlpe Insulated & Pvc Sheathed Aluminum Conductor Armoured Power Cable Of 1.1Kv Grade Of Following Size In The Existing Rcc / Hume / Stoneware / Metal Or Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. Complete In All Respects. 3.5C × 95 Sq Mm 21 Supplying And Laying Dwc Hdpe Pipe As Per Is14930 ( Part-Ii ) Complete With Fitting And Accessories In Ground At The Depth Of 75Cm Laying Of Cable Includingexcavation And Refilling The Trench Etc As Required. ( Od ) / ( Id ) 90Mm / 76 Mm 22 Supply , Installation , Testing And Commissioning Of 70W Smart Bright Led Flood Light ( White Light ) Input Volt ( Ac 90-300V ) >120 Lumens Per Watt With Aluminum And Thermoplastic Glass Housing And Having Long Life Span Of Upto 50, 000 Hrs. Complete In All Respects. 23 P / F Of Maintenance Free Chemical Earthing Using Copper Electrode Of Size 76 Mm Dia, 03 Meter Long Connected With 50X6 Mm Copper Internal Strip Complete With Excavation, Civil Works, Cast Iron Cover With Back Fill Compound Along With 60 Kg Bag Of Back Fill Compound / Sor Compound ( Highly Conductive, Non Corrosive Moisture Retaining Chemical ) Complete. The Voltage Between Neutral & Earth Not To Exceed 0 Volts & Ir Value Less Than 1 Ohm. The Earth Resistance Shall Be As Per Is 3043. Copper Strip Of Size 32 Mm X 5 Mm Be Connected To Main Distribution Board. 24 Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection / Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. ( Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm ) 25 P / F Of Utp Cat-6E Cable In 25Mm Pvc Pipe Of Suitable Size. Complete In All Respect. Make Dlink / Finolex Or Eqv 26 P / F Of Computer Socket-Rj-45 With Key Stone / Face Plate For Internet Connection Of Dlink / Legrandmake With Suitable Connections. Complete In All Respects.