| 1 | Earth work excavation in all kinds of soil except hard rock requiringblasting inclusive of shoring, strutting and bailing out water wherever necessary refillingthe sides of foundation withexcavated earth in layer of 15 mm thickwell rammed and consolidated depositing the surplus earth within compound, clearing and leveling the site with initial lead of 10m etc., and lift of 2m etc., complete. |
| 2 | Supplying and filing in foundation and basement withQuarry dustin layers of 15 cm thick well rammed and consolidation including watering complying with Std specificationetc. |
| 3 | Plain Cement concrete 1:4:8 (One cement four sand and eight aggregates) using 40 mm gauge hard broken granite jelly for foundation wherever necessary etc. complete 1 cum based on SI.No.127 |
| 4 | Centering for soffits of RCC slabs of plane surface like lintels,beams,etc.,includingstrutting3mhigh using mild steel sheets of size 90cm X60cm X and B.G 10 stiffenedwithM.Sanglesofsize25mmX25mmX 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 (Rectangular or Square Column) |
| 5 | Supplying fabricating and placing in position of MS grills for reinforcement rate inc. the cost of steel for all works (the rate to include cost of binding wire also) |
| 6 | Supplying and erecting shuttering with Necessary supports for plinth beam with all cross bracings etc. complete (RCC column footing plinth beam and lintel sider) Using steelplater and angles S.I.No.155 -10m2 |
| 7 | Reinforced cement concrete 1:1 1/2:3 (One cement One and Half Sand and Three aggregate) using 20mm machine broken gauge bard granite jelly for RCC works the rate excludingthe cost of reinforcement grills,centering and shuttering etc., complete |
| 8 | Supplying and erecting shuttering for size soffits supports for plain surface such as reinforced cement slap rectangular beams tee or L beamslintela bed blocks stair and landing beams beams etc cop in all any height (the retrived materials should be taken back by the contractor) the payment for centering shall be given after the concrete is las aid (bottom only) portion using steel plates -10m2 |
| 9 | Brick work in CM 1:5 (one cement five sand) using 2nd class bricks in foundationbasement |
| 10 | Brick work in CM 1:5 (one cement five sand) using 2nd class bricks in Super Structure in Ground Floor. |
| 11 | Supplying and filing in foundation and basement withQurrydustin layers of 15 cm thick well rammed and consolidation including watering complying with Std specificationetc. |
| 12 | Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 610x610x10mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work. |
| 13 | Fabrication and Supply and fixing of steel doorshutter made out of 40 x 40 x 6 mm MS angle section with necessary stiffeners 32 x 6 mm and flats at30 cm intervals and necessary cross diagonals MS flats. The shutter frame shall be fully covered by 18G CC sheet and provided with required locking facilities and hinges including cost of red oxide primers. |
| 14 | Supply and fixing of steel windows using F 7 D2 section for outer frame with mullion of F4B section the shutter shall be provided with roller of 6mm dia including safety bar or 12mm sq. rod at equal interval of 10cm center to center the shutter shall be fitted with 18 G or sheet one handle batch and adjustable winds lay made cut of 20 x 10 mm m.s channel with fixing bracket pegs .Necesasary 4mm hold cyast of 10cm long etc. comp. the window will be finished with one coat of red oxide primer |
| 15 | Supplying and fixing Weld mesh 7.5cm x2.5cm ,10mm Gauge For windows Including Priming Coat Red Oxide Primer etc complete |
| 16 | Dadooing walls withGlazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (one cement, two sand) over 10mm base layer plastering and pointing with white cement neatly as directed etc., complete as per standard specification |
| 17 | Picking the existing Damaged Cement plaster surface etc complete |
| 18 | Plastering with CM1:5(one cement and five sand) 20mm thick10m2. |
| 19 | Plastering with CM1:3(one cement and threesand) 10mm thick10m2. |
| 20 | Plastering with Cement 1:5 (one cement and five sand) 12mm thick etc complete |
| 21 | Weathering course with concrete Broken brick (s.i no 278) &P.D data 54 jelly 20mm gauge in pure slaked lime (no sand to be added ) over roof slab the proportion of brick jelly to lime being 32 to12.5 well beated for giving required slope and thickness as directed by the departmental officers etc complete - |
| 22 | Finishing the top with one course of machine pressed tiles of size 200mm x200mmx20mmof approved quality in c.m 1.3 (one cement add three sand) 12mm tk mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed to full depth of tiles with the same c.m with red oxide and water proffing including curingetc complete |
| 23 | White washing two coats using freshly burnt shell lime, in all floors, including cost of lime and other materials such as brushes, kanjee, scaffolding charges etc., complete |
| 24 | Painting Two Coats on New Iron Work with best synthetic enamal paint of approved colour and quality etc., 10M2. |
| 25 | Painting two coats with ready mixed Plastic Emulsion Paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. - 10 sq.m |
| 26 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point.etc, complete as per standard specificationsSD 38 |
| 27 | Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour.etc, complete as per standard specifications SD 54 |
| 28 | Supply and fixing of single box type 4\"36 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting etc, complete as per standard specificationsSD 87 |
| 29 | Earthing as per P.W.D. standard with an earth electrode of 2Mtr. Class \"B\" GI pipe of dia not less than 32mm complete with necessary masonry work. etc, complete as per standard specificationsSD 234 |
| 30 | Supply and fixing of 3 phase 4 wire 4 way ICDB of 32 A per way with 100 A TPN MC switch with suitable trunking box Ms cable entry boxes and internal connection on suitable angle iron frame work with earth connection etc, complete as per standard specificationsSD. 175 |
| 31 | Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40 A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB\"s should be with the ISI mark etc, complete as per standard specificationsSD.179 |
| 32 | Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5m etc, complete as per standard specifications SD.75 |
| 33 | Supply and fixing of TNEB Board suitable for 3 Phases 63A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2\" x 1 1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 63A fuse units(500V) 1 No. Neutral link, copper earth flat of size 1\" x 1/4\" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete.SD 129 |
| 34 | To provide LPG gas room to store about 50 cylinders with common pipeline to retrofit 3 numbers of cremation chambers, in which high pressure burners – each 6 numbers with required control valves and safety measures to be provided and also upgrade and recoverthe existing gasifier and biomethanation plant to make alternate fuel for the crematorium.About the existing crematoriumThepresentMoolakkarai anjali mayanamcrematoriumishaving3numbersofcremationfurnaceswitha backupofindividual100KWbiomassgasifiersusingfirewoodasafuelandonebiomethanation plant of 5 tons capacity using market and food waste as feedstock.Due to handling and inadequate maintenance of machineries, the furnaces are getting fully damaged along with the gasifiers, exhaust systems and biomethanation plant also.These machineriesarerequiredfullreconditioningandupgradation,whichismustastheyprovide alternative fuel for the crematorium.About the Biomass GasifiersBiomass gasification is a process in which firewood undergoes partial combustion resulted in the emission of combustible gases.The gas composition is as follows:H2 = 20%, CO = 22%, CH4 = 3%, CO2 = 15%, N2 = 40%.Thesegasesareusedforcremationthroughtheburnersplacedinsidethecremation chambers.1.Providing LPG connectionEstimateforproviding50cylindersgasmanifold,pipes,regulators,flexiblehoses, connected controls, safety valves and fittings. Then providing connection pipelines to 4 cremationchamberswithpressurevalves,safetyvalvesandcontrols. Connectingof6 numbers high pressure gas burners for each furnace with controls, providing modification in the furnaces with complete |
| 35 | 2.Furnace maintenanceEstimate for removal and reconstruction of cremation chamber, ash chamber, secondary chamber using high alumina refractory of various sizes of standard, end arch, stew, grate, slabsandalsoinsulationbricksandceramicblancket.Repaireandreconditioningof furnacemaindoor,bodychargingtrolly,exhaustscrubbers,FDblowerandpipeline connectiontochimney.Repaire,replacementandupgradationof100KWbiomass gasifierwithconnectedgasdeliverychamber,gaspipelinesandburners |
| 36 | 3.Biomethanation plantEstimate for removal and cleaning of digester providing required repaire and recoveries in the areas of digester, pipelines, input and outlet, feeding chambers, slurry outlet chambers, gas delivery valves, pipelines upto the furnace.Replacement of shredder for the capacity of5tons/daywithsuitabletable,foundationandchargingmechanism,providinghigh temperaturewithhighcombustionratiobiogasburnersinthefurnace |
| 37 | Add GST 18% |