Road And Building Division has published Tender For Construction Of Biomedical Waste Management At Koida Chc Under Koida Block For The Year 2021-22. Submission Date for this Tender is 19-07-2023. Bio Medical Waste Tenders in rourkela Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earth Workinexavationoffoundation in hard soil within initial leads of 50m & lifts of 1.5m including dressing and levelling of bed etc. and adding contractor"s profit and over head charges, etc. complete in all respect. |
2 | Supplying & filling of foundation with course sand well watered and rammed including cost, cost of all labour, carriage, royalty complete in all respect.(As Per A/R Page No-1, Item No-2) |
3 | Cement Concrete (1:3:6) using 40mmsize hard granite C.B. metal approved quality from approved quarry including cost, carriage, royalty, cost of all labour. etc complete and as directed by E.I.C. |
4 | Cement Concrete (1:2:4) using 12mmsize hard granite C.B. chips approved quality from approved quarry including cost, carriage, royalty, cost of all labour. etc complete and as directed by E.I.C. |
5 | R.C.C. M-20 grade with 20mm and down grade C.B. chips of approved quality from approved quarry including hoisting, laying hire charges of concrete mixture, vibrator, watering, curing and cost of all materials and labour, centering shuttering etc complete but excluding cost of reinforcement. |
6 | (A) Plinth Band |
7 | (B) Lintel Band |
8 | (C)Chajja |
9 | (D) Beam |
10 | (D) Roof Slab |
11 | Straightening, cutting, bending bent up or coiled rods, including cranking, hooking, welding or jointing the M.S. rods or tor confirming to I.S. 432 (Plain) and 1785 (Tor) steel and binding, tying the grills, hoisting, lowering and placing in proper position required for R.C.C. works including cost, conveyance and taxes of M.S. rods or tor steel and binding wires of 18 to 20 gauge and cost of all labour etc.complete in all respect. |
12 | Random Rubble stone masonry in cm (1:6) in foundation & plinth using gh stones of app quality, including splays, cuttings, circular moldings, watering, curing, cost, conveyance, taxes, royalties of all materials & labour with T&P etc. complete in all respect. |
13 | Brick work with Flyash Bricks 25cm x 12cm x 8cm size having crushing strength not less than 75Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:6) in Super Structure including watering curing, cost of carriage, royalty and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
14 | (A) Steps 1 Side Slopes |
15 | (B) Main Wall Partition wall |
16 | 20mm thick C.P. With C.M. (1:6) over stone masonary with cost & conveyance of all materials, cost of all labour, etc complete. |
17 | 12mm thick C.P.(1:6) on brick masonary to the smooth surface including watering, curing, cost, carriage, royalty of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
18 | 16mm thick C.P. (1:6) over brick masonary to the smooth surface including watering, curing cost, carriage, royalty, and taxes of all materials, cost of all labour, etc complete as per the direction of E.I.C. |
19 | 6 mm thick C.P. (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment , watering, curing cost, carriage & royaltyof all materials, cost of all labour,etc complete as per the direction ofE.I.C.Ref(A/R-2006,P-103,Item no-27) |
20 | Supplying, fitting & fixing of 600x600 mm size & 10 mm thick Vitrified floor tileslaid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all materials, etc. required for the work all complete as per direction ofE.I.C. |
21 | Fixing of10 mm thick& sizeof Ceramic wall tilesin dados skirting and risers of steps on 12mm thick CP (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the tiles including cost, carriage, cost of all labour etc. complete. |
22 | Priming 1 coat with wallprimer water bond cement primer including all labour, materials etc. complete. |
23 | Finishing wall surface with Cement based wall putty (water based) of approved make and finished smooth & even surface to receive painting including cost of scaffolding etc. with cost of all materials, labour etc. complete. |
24 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint etc complete. |
25 | Wall painting two coat with any approved weather coat paintincluding cost of all materials, labour and T&P require for the work etc. complete as directed by the E.I.C. |
26 | Supplying of M.S. Door, Window with grills, Grills made out of M.S. Angle frame, M.S. Flat, Sheetetc of approved section & design, electrically welded properly with all necessary locking arrengement, and 1 coat red oxide primer including cost of all materials, labour charges, carriage of materials to site etc. complete. |
27 | (A) DOOR & WINDOW SHUTTERS |
28 | (B) GRILLS |
29 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50 mm dia of 2 mm thick circular pipe with Balustrade of size 32 mm x 32mm x 2mm @ 0.90 mtr C/C and stainless aquare pipe bracing of size case as per approved design and specification, buffing, polishing etc. with the cost, conveyance taxses of all material, cost of all labour etc. complete in all respect. |
30 | Priming one coat with any approved primer including cost of primmer & labour to give an even shade excluding cost of primer.(As per A.R. 93/1) |
31 | Painting two coats with approved enamel paints of approved colour, shade over a coat ofprimer including sand papering, polishing the surface, cost, conveyances of all materials and cost of all labour etc, complete as per specification & direction of E.I.C. |
32 | 25mm thick CC 1:2:2 with 6mm size CB chips for grading concret over roof slab etc. complete. |
33 | Providing, fitting, fixing of Chequered tiles & filling the joints with sand of approved quality including rubbing & polishing etc. complete including cost of all materials, labour with T&P etc complete in all respect. |
34 | EI |
35 | Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5Amp, 250V modular type switch ISI marked and ceiling rose ISI marked mounted on Modularbox having modular base &cover of suitable size, MSbox with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection as per direction of Engineer in Charge(Make of wire-Finolex/L&T/Anchor/Havells/V-Guard/HPL/Mescab) |
36 | Group A |
37 | Group B |
38 | Group C |
39 | S/F of modular boxes |
40 | 12 module |
41 | Supplying and fixing of following modular type switch/socket on the existing switch box/cover including connection etc. as required |
42 | 5 / 6 Amp switch |
43 | 15 / 16 Amp switch( 3 for patholab and 4 Immunization room) |
44 | 3 pin 5 / 6 Amp socket outlet |
45 | 6 pin 15/16 Amp socket outlet |
46 | 5/6 a switch,2 way |
47 | Recessed submain wiring alongwith earth wire with the following sizes of PVC insulated single core multistrand copper conductor ISI marked conforming to IS-694/1990 in 20mm dia non metallic heavy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire -Finolex/L&T/Anchor/Havells/V-Guard/Great White/Mescab/HPL) |
48 | 1 X 2.5sq.mm +1 X 1.5sqmm ( for Invertor Wiring ) |
49 | 2 X 2.5sq.mm +1 X 1.5sqmm |
50 | 2 X 4sq.mm +1 X 1.5sqmm. |
51 | 4 x 6 sq.mm + 2 x 2.5 sq.mm-d0- |
52 | Earthing wih Copper earth plate 600 mm x 600 mm x 3.15 mm thick ISI marked including accessories and providing massonary with cover plate having locking arrangement and watering pipe etc. (but without charcoal and salt as required)(For panel) |
53 | Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc. as required(For panel) |
54 | Supply and fixing of single pole MCB with sheet enclosure, distribution board on surface / recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required (But with out MCB/RCCB/ISOLATOR) |
55 | 12WAY, Double DOOR |
56 | Supply and fixing of 5 amp to 32 amp rating 240/415 V "B" or "C" series miniature circuit breaker suitable for lighting and other loads of the following poles in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required |
57 | SINGLE POLE |
58 | Installation, Testing and commissioning of ceiling fan including wiring the down rod of standard length (up to 30 cm) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor etc.as required. |
59 | 20 Watt LED Tube Light |
60 | Installation, Testing and commissioning of ceiling fan including wiring the down rod of standard length (up to 30 cm) with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor etc.as required. |
61 | 50 Watt Ceiling Fan 48" 5 star rated |
62 | Supply and fixing of fan regulator(Cona/ Anchor/ Usha/Bajaj) |
63 | Electronics step type |
64 | Installation, Testing and commissioning of exhaust fan up to 450 mm sweep in the existing opening including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required. |
65 | 300 mm sweep Exhaust fan 900rpm |
66 | S/F of 63 A TPN Bus -bar |
67 | S/F of 3 x 1/2 core X 35sq.mmPVC Alumimnium Armoured cable(make -Mescab/Polycab / KEI) |
68 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq. mm but not exceeding 120 mmsq on surface as required |
69 | Supply and making end termination with brass compression gland and aluminium logs for following size of PVC insulated and PVC sheathed / XLPE aluminium cable of 1.1kv grade (without cost of cable ) as required. |
70 | 3 X 1/2 core 35sq.mm A2 X FY |
71 | S/F of 100W Street light(makke - Havells) |
72 | S/F of 100W Flood ight(makke - Havells) |
73 | S/F ofPanel -200A , 36KA MCCB,4 pole -1NO.,200ABus-bar(make -legrand/hpl) |
74 | Eco Volt 1050 Inverter, 900VA,12V,tall tubular batterey ILTT22048, 16H and Inverter trolley(make - Micotek/Luminous) |
75 | PH Work |
76 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. |
77 | 25mm dia PVC ASTM pipe (sch-80) Ground floor |
78 | 32mm dia PVC ASTM pipe (sch-80) roof top |
79 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materialsincluding cost & conveyance of all materials to worksite, payment oftaxes etc. allcomplete as per P.H specification and direction of the Engineer-in-charge. |
80 | 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
81 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
82 | 25mm dia brassfull way valve (Shakti make) |
83 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite,payment of royality, taxes etc. all complete as perdirection ofEngineer-in-charge. |
84 | Ground floor |
85 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proofas per P.H. specification and direction of Engineer-in-charge |
86 | Ground floor |
87 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damagesincluding watering ,curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. |
88 | Ground floor |
89 | Supplying all materials , labour, T&P and fixing rotational mouldedpolyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr widthKBbrickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxesetc.all complete as per approved drawing , P.H. specification and direction ofEngineer-in-charge |
90 | 1000 liters capacityPVC water storage tank (Syntex three leyer white) |
91 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer"s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment oftaxes etc.all complete as per P.H specification and direction of the Engineer-in-charge. |
92 | 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
93 | 110mm U-PVC‘P’ Trap(Ori Plast/Finolex/Supreme Make) |
94 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
95 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
96 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
97 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered "Hot" and "Cold" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment oftaxes etc. all complete as perP.H specification and direction of the Engineer-in-charge |
98 | 550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with PEDESTRAL |
99 | Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy