| 1 | Dismantling floor, hearth, PCC tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 2 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, any description |
| 3 | Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 4 | Demolition of cement concrete(reinforced) roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work (reinforcement cut as required to facilitate demolition) |
| 5 | Dismantling mild steel work of any description not otherwise provided for handrails, stringers, chequered plate etc. |
| 6 | Dismantling structural steel work including doors, gates but excludingframed truss etc |
| 7 | Dismantling of AC (Corrugated, semicorrugated, etc) sheet in roof coverings |
| 8 | M & L for cement concrete Type B1, 1:2:4 mix (using 20 mm graded aggregate) in sub base, floor and pavings with 100mm thickness. |
| 9 | M & L for Brickwork with subclass `B\" bricks, straight or curved on plan exc 6m mean radius, built in Cement mortar 1:4 all as specified and directed. |
| 10 | M & L for reinforced cement concrete (nominal mix) of Type B1, 1:2:4 mix (20mm graded aggregate) in slabs supported on walls, beams &columns in floors, roofs, landings, balconies, canopies, deck slabs & in shelves & the like |
| 11 | M & L for reinforced cement concrete (nominal mix) of Type B1, 1:2:4 mix (20mm graded aggregate) in Fins, fascias, louvres, parapets & railings exc. 60cm in height, newels, balustrade & the like |
| 12 | M & L for reinforced cement concrete (nominal mix) of Type B1, 1:2:4 mix (20mm graded aggregate) in chajjas, and the like |
| 13 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; n exc. 200mm thick (Horizontal or sloping) |
| 14 | Formwork to fins, louvers, fascia |
| 15 | Formwork to chullah hoods, chajjas, troughs and similar items including edges |
| 16 | M & L for TMT mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 17 | M & L for TMT mild steel bars6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 18 | S & F rolled mild steel in stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. of Fe 410-W (Gde-E- 250) complete |
| 19 | S & F rolled mild steel in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks & hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails & guides) & hanging; also fastening & fixing complete |
| 20 | S & F 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides |
| 21 | S & F 100mm Butt hinges, cast brass, with MS hinge pin, bright polished & fixed, type B-11 |
| 22 | S & F of extruded brass handles, fabricated type polished of size 125mm. |
| 23 | S & F 100 mm long brass barrel tower bolts, with cast or sheet barrel & rolled or cast bolts & fixed |
| 24 | S & F 200mm brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) & fixing bolt with rolled or drawn brass bolts & fixed |
| 25 | M & L for wrought second class hardwood timber framed and fixed in scantling for flooring complete all as specified and directed |
| 26 | M & L for rendering 20mm thick in CM (1:4) on brick masonry surfaces finished even and smooth without using extra cement and providing neeru finishing. |
| 27 | M & L for rendering 20mm thick in CM (1:4) on brick masonry surfaces finished even and smooth without using extra cement. |
| 28 | M & L for rendering 20mm thick in CM (1:4) on brick masonry surfaces finished even and smooth without using extra cement and providing sand faced finishing. |
| 29 | M & L for rendering10mm thick in CM (1:4) on fair faces of concrete surfaces on finished even and smooth without using extra cement and providing sand faced finishing. |
| 30 | M & L for preparation of new surfaces of wall for two coats of cement paint over one coat of primer using alkali resistant priming paint. |
| 31 | M & L for two coats of chlorinated rubber paint over a coat of chlorinated rubber primer, including preparation of new plastered surface of wall complete all as specified and directed |
| 32 | M & L for two coats of chlorinated rubber paint over a coat of chlorinated rubber primer, including preparation of new plastered surface of ceiling complete all as specified and directed |
| 33 | M & L for two coats of chlorinated rubber paint over a coat of chlorinated rubber primer, including preparation of old painted steel surface complete all as specified and directed |
| 34 | M & L for two coats of chlorinated rubber paint over a coat of chlorinated rubber primer, including preparation of new/previously untreated steel surface complete all as specified and directed. |
| 35 | M & L for two coats of chlorinated rubber paint over a coat of chlorinated rubber primer, including preparation of wood surface complete all as specified and directed. |
| 36 | M & L for FRP chequered plate of thickness 3mm over FRP grating of mesh size of 38mmx38mm & rib thickness of 5mm to 7mm |
| 37 | M & L for FRP chequered plate of thickness 3mm for vertical surface |
| 38 | M & L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets including fixing with L-type or \"J\" type or cranked hooks bolt in roofs, walls etc.complete. |
| 39 | M & L for Asbestos cement two piece adjustable plain wing ridge 6mm thick Fixed with L-type or J type or cranked hook bolts |
| 40 | Supply only Liquid water proofing compound Aquaplast of Aquatek Conchem or equivalent. |
| 41 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard / dence soil etc complete all as specified and directed. |
| 42 | Removal of excavated materials not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points etc complete all as specified and directed. |
| 43 | M & L Hardcore of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface with broken stone or boulders |
| 44 | M & L for cement concrete type B-1 1:2:4 using (20 mm graded stone aggregates) 100 mm thick as in hard standing of building finished even and smooth without using extra cement complete all as specified and directed |
| 45 | S & F Forming Contraction (Dummy) joints grade \"A\" 65mm deep x 10mm wide, filled with sealing compound complete all as specified and directed. |