Tender For Balance Items Of Work For Completion Of Ftr. Bsf Admin Block At Bsf Humhama, budgam-Jammu And Kashmir

Public Works Department-PWD has published Tender For Balance Items Of Work For Completion Of Ftr. Bsf Admin Block At Bsf Humhama. Submission Date for this Tender is 26-07-2023. Road Repair Tenders in budgam Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38562868
Corrigendum : Tender For Balance Items Of Work For Completion Of Ftr. Bsf Admin Block At Bsf Humhama
Open Tender
Indian
Jammu And Kashmir
budgam
26-07-2023

Tender Details

Balance Items Of Work For Completion Of Ftr. Bsf Admin Block At Bsf Humhama- 1 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) In Trenches For Foundations, Drains, Pipes, Cables Etc. ( Not Exceeding 1.5 M In Width ) And For Shafts, Wells, Cesspitsand The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides Andrammingofbottomsliftupto1.5M, Includinggettingoutexcavatedearthand Disposal Of Surplus Excavated Earth As Directed, Within A Lead Of 50 Metres:All Kinds Of Soil 2 Earth Work In Bulk Excavation By Mechanical Means ( Hydraulic Excavator ) Over Areas ( Exceeding30cmindepth, 1.5Minwidthaswellas10m2onplan ) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil. 3 Extrafor Everyadditionalliftof1.5Morpartthereofinexcavation / Banking Excavated Or Stacked Material : All Kinds Of Soil : 4 Surface Dressing Of The Ground Including Removing Vegetation And In-Equalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto 50 M And Lift Upto 1.5 M In -All Kinds Of Soil. 5 Providing And Laying Of Stone Soling ( Hand Packed ) In Excavated Trenches Including Carriage By Mechanical Transport At Site Of Work. 6 Supplyingandfillinginplinthwithfinesandunderfloorsincluding, Watering, Ramming, Consolidatingand Dressing Complete. 7 Cement Concrete ( Cast-In-Situ ) Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level With: 8 1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 9 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 10 Reinforcedcementconcreteworkinwalls ( Anythickness ) Includingattachedpilasters, Buttresses, Plinthandstringcourses, Fillets, Columns, Pillars, Piers, Abutments, Postsand Struts Uptofloorfivelevelincludingcuringbutexcludingcostofcenteringshuttering, Finishing And Reinforcement. 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 11 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 12 Steel Reinforcement Forr.C.C.Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level 13 Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. 14 Form Workcentering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: 15 Suspended Floors, Roofs, Landings, Balconies And Access Platform With Waterproofing Ply 12 Mm Thick 16 Lintel, Beams, Plinth Beams, Girders, Bressumers And Cantilevers With Waterproofing Ply 12 Mm Thick 17 Columns, Pillars, Piers, Abutments, Posts And Struts. 18 Spiral Staircases ( Including Landings ) 19 Edges Of Slabs And Breaks In Floors And Walls Under 20 Cm Wide 20 Brickworkwithcommonburntclay ( Non-Modular ) Bricksofclassdesignation 7.5In Foundation And Plinth Including Curing In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) 21 Extra For Brick Work With Common Burnt Clay Bricks / Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level 22 Qty Vide Above Window Minus Steps-Wt-St 23 Extra For Brick Work In: Square Or Rectangular Pillars 24 Qty Vide Above Window Extrude 25 Half Brick Masonry With Common Burnt Clay ( Non-Modular ) Bricks Of Class Designation 7.5 In Foundations And Plinth Including Curing In : Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 26 Extra For Half Brick Masonry In Superstructure Above Plinth Level Upto Floor V Level. 27 Providing And Fixing Aluminum Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Zsections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixedwithdashfastenerofrequireddia.Andsizeincluding Necessary Filling Up Of Gaps At Junctions I.E, At Top, Bottom And Sides Withrequiredepdmrubber / Neoprenegasketfeltetc.Aluminumsections Shallbesmooth, Rustfree, Straight, Mitredandjointedmechanically Whereverrequiredincludingcleatangle, Aluminumsnapbeadingfor Glazing / Panelling, C.P. Brass / Stainless Steel Screws, All Complete As Perv Architectural Drawings And The Directions Of Engineer-In-Charge ( Glazing, Panelling And Dash Fasteners To Be Paid For Separately. ) 22.1.1For Fixed Portion 28 A ) Polyesterpowdercoatedaluminum ( Minimumthicknessof Polyester Powder Coated 50 Microns ) B ) For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately. ) 29 Polyesterpowdercoatedaluminum ( Minimumthicknessof Polyester Powder Coated 50 Microns ) 30 Providingandfixingglazinginaluminumdoor, Window, Ventilator Shuttersandpartitionsetc.Withepdmrubber / Neoprenegasketetc. Complete As Per The Architectural Drawings And The Directions Of Engineer- In-Charge. ( Cost Of Aluminum Snap Beading Shall Be Paid In Basic Item. ) Withfloatglasspanesof5.0Mmthickness ( Weightnotless Than 12.50 Kg / Sqm ) 31 With Float Glass Panes Of 8 Mm Thickness ( Weight Not Less Than 20.0 Kg / Sqm ) 32 With Galvanized M.S. Wire Gauge With Wire Of Dia 0.63 Mm With 12 Mm Mild Steel U Beading 33 Providing And Fixing Of 4Mm Thick Acp Sheets In Two Layers For Door Shutters Including Epdm Rubber / Neoprene Gasket And Snap Beading Etc Complete Job. Qty Doors Item 16 - Item 20 34 Providing&Fixingstainlesssteel ( Ss-304Grade ) Adjustablefriction Windows Stays Of Approved Quality Withnecessary Stainless Steel Screws Etc. To The Side Hung Windows As Per Direction Of Engineer-In-Charge Complete 255X19mm 35 Providing And Fixing Brass 100Mm Mortice Latch And Lock With 6Levers Without Pair Of Handles ( Best Make Of Approved Quality ) For Aluminium Doors Including Necessary Cutting And Making Good Etc. Complete. 36 Providingandfixingaluminumcasementwindowsfastnerofrequired Length For Aluminum Windows With Necessary Screws Etc. Complete. Powder Coated Minimum Thickness 50 Micron Aluminum 37 Dry Random Rubble Masonry With Hard Stone In Foundation And Plinth: With Bond Stone. Without Bond Stone 38 15Mmcementplaster Ontheroughsideofsingleorhalfbrickwallof Mix:1 : 6 ( 1 Cement : 6 Fine Sand ) 39 20Mm Cement Plaster Of Mix:1 : 6 ( 1 Cement : 6 Fine Sand ) 40 6Mm Cement Plaster6 Mm Cement Plaster To Ceiling Of Mix 1 : 3 ( 1 Cement : 3 Fine Sand ) 41 Providing&Fixingfalseceilingatallheightswithgrg ( Glassfibre Reinforced Gypsum ) False Ceiling Tiles Of Size 595X595 Mm Of Approved Texture, Designandpatternshavingmoisturecontentlessthan2%, Humidity Resistance Of 99%, Nrc0.50 To 0.75 As Per Is 8225:1987, Non Combustibleasperbs476 ( Part4 ) -1970Andlightreflectanceof85% ( Minimum ) To Be Laid In True Horizontal Level Suspended On Inter-Locking Metalt-Gridofhotdippedgalvanisedironsectionof0.33Mmthick ( Galvanized@ 120Grams Persqm Including Bothsides ) Comprising Of Main-T Runners Of Size 15X32 Mm Of Length 3000 Mm, Cross - T Of Size 15X32mmoflength1200mmandsecondaryintermediatecross-Tof Size 15X32 Mm Of Length 600Mm To Form Grid Module Of Size 600 X 600 Mm, Suspended From Ceiling Using Galvanised Mild Steel Items ( Galvanizing @ 80 Grams Per Sqm ) I.E. 50 Mm Long, 8 Mm Outer Diameter M-6 Dash Fasteners, 6 Mm Dia Fully Threaded Hanger Rod Upto 1000 Mm Length And L-Shape Level Adjuster Of Size 85X25x2 Mm. Galvanised Iron Perimeterwall Angle Of Size 24X24x0.40 Mm Of Length 3000Mm To Be Fixed On Periphery Wall / Partition With The Help Of Plastic Rawl Plugs At 450Mmcentertocenterand40mmlongdrywallwoodscrews.The Workshallbecarriedoutasperspecifications, Drawingandasper Directions Of The Engineer-In-Charge.Withsemiperforated12mmthickmicrotegularedgedgrg False Ceiling Tiles. 42 With Fully Perforated 12 Mm Thick Micro Tegular Edged Or 10 Mm Thick Square Edged Grg False Ceiling Tiles. 43 Providing And Applyingwhitecement Based Putty Of Specified Thickness, Ofapprovedbrandandmanufacturer, Overtheplasteredwallsurfaceto Prepare The Surface Even And Smooth Complete.1 Mm Thick 44 2 Mm Thick 45 Ceramic Glazed Tilesprovidingandfixingistqualityceramicglazedwalltilesconformingtois:15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer- In-Charge, In Skirting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 46 Providing And Laying Ceramic Glazed Floor Tiles 300X300 Mm ( Thickness Tobespecifiedbythemanufacturers ) Of1stqualityconformingtois: 15622 Of Approved Make, Laidon 20 Mm Thick Bed Of Cement Mortar 1: 4 ( 1Cement:4Coarsesand ) Includingpointingthejointswithwhite Cement And Matching Pigment Etc., Complete. In Colour Such As White, Ivory, Grey, Fume Red Brown.In All Colours, Shades, Except White, Ivory, Fume Red Brown 47 Vitrified Floor Tilesproviding And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make, In All Colours And Shades, Laid On20mm Thick Cement Mortar 1:4 ( 1Cement :4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc. Completesize Of Tile 600X600 Mm 48 Providing And Fixing Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut Forkitchen Platforms, Vanity Counters, Window Sills, Facias And Similar Locations, Of Requiredsize, Approvedshade, Colourandtexturelaidover20mmthickbasecement Mortar1:4 ( 1Cement:4Coarsesand ) , Jointstreatedwithwhitecement, Mixedwith Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour Or Shade 49 ( Area Of Slab Over 0.5 Sqm ) 50 Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over20mm ( Average ) Thickbaseofcementmortar1:4 ( 1Cement:4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurryadmixed With Pigment Of Matching Shade Including Rubbing, Curingandpolishingetc.Allcompleteasspecifiedandas Directed By The Engineer-In-Charge.Polishedgranitestoneslabjetblack, Cherryred, Elite Brown, Cat Eye Or Equivalent. Block-A, B, C ( Room Floors ) Qty Vide Item-5 51 Providingedgemouldingto18mm / 16Mmthickmarblestonecounters, Vanitiesetc. Including Machine Polishing To Edge To Give High Gloss Finish Etc. Complete As Per Design Approved By Engineer-In-Charge. 52 Granite Work 53 Providingandlayingwaterproofingtreatmentinsunkenportionof Wcs, Bathroometc., Byapplyingcementslurrymixedwithwater Proofing Cement Compound Consisting Of Applying : ( A ) Firstlayerofslurryofcement@0.488Kg / Sqmmixedwithwith Waterproofingcementcompound@0.253Kg / Sqm.Thislayerwillbe Allowed To Air Cure For 4 Hours. ( B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm . This Layer Will Be Allowed Therateincludespreparationofsurface, Treatmentandsealingofall Joints, Corners, Junctionsofpipesandmasonrywithpolymermixed Slurry To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. 54 Providingandfixingstainlesssteel ( Grade304 ) Railingmadeofhollow Tubeschannels, Platesetc.Includingwelding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete , Including Fixing The Railing With Necessary Accessories And Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc. Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab Withsuitablearrangementasperapprovalofengineer-In-Charge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc. ) . 55 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work 56 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work 57 Finishingwallswithtexturedexteriorpaintofrequiredshadeonnew Work ( Two Or More Coats Applied @ 3.28 Liter / 10Sqm ) Over And Including Base Coat Of Exterior Primer Applied @ 2.20Kg / 10Sqm 58 Providing And Fixing Of Khatam Bandi Ceiling Of First Class Budloo / Fir Wood Excluding The Cost Of Frame Work Which Is To Be Paid Separately. 59 Chaar Gul 60 Providing Wood Work In Frames Of False Ceiling, Partitions Etc. Sawn And Fixed Inposition : 61 Kiln Seasoned And Chemically Treated Hollock Wood 62 Providingandfixingplainliningwithnecessaryscrews / Nuts&Bolts / Nails, Includingacoatofapprovedprimerononeface, Andfixedonwooden / Steel Frame Work, Complete As Per Direction Of Engineer-In-Charge ( Frame Work Shall Be Paid For Separately ) . 12Mm Thick Commercial Ply Conforming To S : 1328 Bwr Type 63 Providing And Fixing Of 10Mm Thick Laminated Wooden Flooring / Wall Pannel ( Ac4 ) Of Approved Make , Shade And Design Includingprovidingthermocol Sheeting Of Required Thickness Underneath Wooden Flooringincluding Cost Of Door Profile, Conceave Beading And Cornices Complete Job. 64 Providing And Fixing Precoated Galvanized Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0.50 Mm ( + 0.05 % ) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of Thesheetandpolyestertopcoat15-18Microns. Sheetshouldhave Protectiveguardfilmof25micronsminimumtoavoidscratchesduring Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X 55 Mm ) With Epdm Seal, Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Raftersand Trusses And Includingcuttingto Size And Shape Wherever Required. 65 Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded 66 Accessoriesprovidingandfixingprecoatedgalvanisedsteel Sheetroofing Accessories0.50Mm ( +0.05% ) Totalcoatedthickness, Zinccoating120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primeronbothsideofthesheetandpolyestertopcoat15-18Microns Using Self Drilling / Self Tapping Screws Complete : Ridges Plain ( 500 - 600Mm ) 67 Providing And Fixing Plained Eaves Boarding. 68 250X32 Mm ( Nominal Size ) 2Nd Class Kail Wood 69 Providing And Fixing Of 12Mm Thick Imported Wooden T&G Ceiling Including Frame Work Of Budloo Wood Joists Of 2 X 1.5Section Complete Including Cost Of Nails, Fevicol, 3X3 Cornice And Applying Oftwo Coats Of Touch Wood Including Scaffolding And Stagging Charges. 70 Providing & Fixing Soil, Waste And Vent Pipes Conforming To Is-13592 & Fittings ( Is-14735 ) Suitable To Rubber Ring , Jointing , Junction , Clean-Out Plug , Cowls , Offsets , Collar , Ms Holder Bat Clamp , Access Pieces , Trap Of Self Cleaning Design Etc . Complete Including Jointing, ( Type-Bof Standard Quality Isi Marked ) . 71 ( I ) 40Mmod Pipe 72 ( Ii ) 75Mmod Pipe 73 ( Iii ) 110Mmod Pipe 74 ( Iv ) 160Mmod Pipe 75 Concealed Pipe Including Painting With Anti Corrosivebitumastic Paint, Cutting Chases And Making Good The Wall: 76 15 Mm Dia. Nominal Bore 77 20 Mm Dia. Nominal Bore 78 Providingandfixingg.I.Pipescompletewithg.I.Fittingsincluding Trenching And Refilling Etc. ( External Work ) 79 25 Mm Dia. Nominal Bore 80 32 Mm Dia. Nominal Bore 81 40 Mm Dia. Nominal Bore 82 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete 83 15 Mm Nominal Bore 84 20 Mm Nominal Bore 85 25 Mm Nominal Bore 86 Providingandfixinggunmetalnon-Returnvalveofapprovedquality ( Screwed End ) 87 32 Mm Nominal Bore 88 40 Mm Nominal Bore 89 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storagetankisi : 12701 Marked, With Cover And Suitable Locking Arrangementandmaking Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank 90 Tanki Nipple 25Mm 91 Cutting Holes Up To 30X30 Cm In Walls Including Making Good The Same: With Common Burnt Clay ( Non Modular ) Bricks 92 Cutting Holes Up To 15X15cm In R.C.C. Floors And Roofs For Passing Drain Pipeetc.Andrepairingtheholeafterinsertionofdrainpipeetc. With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Gradedstone Aggregate20mm Nominalsize ) , Includingfinishingcompletesoasto Make It Leak Proof. 93 C.P. Brass Fittingsprovidingandfixing15mmnominalborec.P.Brassbibcockof Approved Quality Conforming To Is : 8931 94 Providing And Fixing 15 Mm Nominal Bore C.P. Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is : 8931 95 Providingandfixing15mmnominalborec.P.Brassanglevalvefor Basin Mixer And Geyser Points Of Approved Make Conforming To Is : 8931 96 Providingandfixing15mmnominalboreofstandardbacktypec.P. Brasscloseholebasinmixerpillartapofapprovedqualityandmake, Weighing Not Less Than 1.970 Kg. 97 Providing And Fixing Ptmt Grating Of Approved Quality And Colour. 98 Rectangular Type With Open Able Circular Lid. 150 Mm Nominal Size Square 100 Mm Diameter Of The Inner Hinged Round Grating. 99 Providing And Fixing Ptmt Soap Dish Holder Having Length Of 138Mm, Breadth102mm, Heightof75mmwithconcealedfittingarrangements, Weighing Not Less Than 106Gms. 100 Providing And Fixing Un Plasticized P.V.C. Connection Pipe Withptmt Nuts, Collars And Bush Of Approved Quality And Colour 15 Mm Nominal Bore With 45 Cm Length. 101 Roviding And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Liter Low Level White P.V.C. Flushing Cistern, Including Flush Pipe With Manually Controlled Device ( Handle Lever ) , Conforming To 1S:7231, With All Fiings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required: 18.2.1 W.C. Pan With 1Si Marked White Solid Plastic Seat And Lid. 102 Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 103 Providing And Fixing Wash Basin With15 Mm Dia Cp Brass Single Hole Basin Mixer Of Approved Quality And Make, Including Painting Of Fittings And Brackets, Cutling Ad Making Good The Walls Wherever Required Complee Job ( A ) White Vitreous Chia Wash Basin Size 550X400 Nm With A 15 Mm Cp Brass Single Hole Basin Mixer 104 Providing & Fixing Stainless Steel Isi-304 ( 18 / 8 ) Kitchen Sink As Per Is-13983 With Ci Brackets And Stainless Steel Plug 40Mm, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required 600X450mm Bowl Depth 200Mm ( Standard Make ) . 105 Providing & Fixing Cp15mm Nominal Bore Sink Mixer Incl Acessories ( Isi Make ) Of Make And Type To Be Approved By Engineer In Charge 106 Providing And Fixing P, V.C. Waste Pipe Flexible Pipe For Sink Or Wash Basin Including P.V.C Waste Fittings Complete: 40Mm Dia 107 Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350mm And 340X410x265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.L. Camps Complete, Inciuding Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required: 108 Range Of Three Urinal Basins With 10 Liter White P.V.C Automatic Flushing Cistern. 109 Range Of Four Urinal Basins With 10 Liter White P.V.C Automatic Flushing Cistern. 110 Providing & Fixing White Urinal Partitions Of350x675x130mm Size Includingfittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required ) Standard Make 111 Poviding And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto I Metre Long With S.S. Triangular Plate To European Type W.C. Of Quality And Make As Approved By Engineer-In-Charge. 112 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Serews And Washers Complete. 113 Providing And Fixing 600X 120X5m Glass Shelf With Edges Round Off Supported On Anodized Aluminum Angle Frame With C.P. Brass Brackets And Guard Rail Complete Fixed With 40 Mm Long Serews. Rawl Plugs. Ctc. Complete 114 Providing And Fixing Toilet Paper Holder C.P. Brass 115 Providing And Fixing Ptmt Waste Coupling For Wash Basin And Sink. Of Approved Quality And Colour: Waste Coupling 31Mm Of 79 Mm Length And 62 Mm Breadth Weight Not Less Than 45Gms. 116 Providing & Fixing Towel Rail C.P. Brass 600 X20 Mm Together With A Pair Of Each C.P. Brass Brackets To Fit The Size Of Towel Rail ( Isi Make ) . 117 Providing & Fixing Towel Ring C.P. Brass ( Isi Make ) 118 Providing & Fixing Cp Health Faucet ( Abulation Spray ) ( Isi Make ) Complete Including Chain Etc. 119 Providing & Fixing Cp Gratings ( Jali ) Anti-Cockroach Of Standard Qualitycomplete Job. 120 Constructingbrickmasonrychamberforundergroundc.I.Inspection Chamber And Bend With Common Burnt Clay ( Non Modular ) Bricks Of Class Designation7.5Incementmortar1:4 ( 1Cement:4Coarsesand ) C.I. Coverwithframe ( Lightduty ) 455X610mminternaldimensions, Total Weight Of Cover With Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15 Kg ) R.C.C. Top Slab With 1:1 ½ : 3 Mix ( 1 Cement :1½ Coarse Sand:3Gradedstone Aggregate20mmnominal Size ) , Foundation Concrete 1:5:10 ( 1 Cement: 5 Fine Sand: 10 Graded Stone Aggregate40mmnominalsize ) , Insideplastering12mmthickwith Cementmortar1:3 ( 1Cement:3Coarsesand ) Finishedsmoothwitha Floating Coat Of Neat Cement On Walls And Bed Concrete Etc. Complete As Per Standard Design : Inside Dimensions 455X610 Mm And 45 Cm Deep For Single Pipe Line- 121 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth And Curing Complete 122 Providingandfixing15cmwide45cmoverallsemicircularplaing.S. Sheet Gutter With Iron Brackets 40X3mm Size, Bolts, Nuts And Washers Etc. Including Making Necessary Connections With Rain Water Pipes Complete.0.63 Mm Thick With Zinc Coating Not Less Than 275 Gram / M2 123 Providingandfixingonwallfaceun-Plasticizedrigidpvcrainwater Pipesconformingtois:13592Typea Includingjointingwithsealring Conforming To Is: 5382 Leaving 10 Mm Gap For Thermal Expansion. ( I ) Single Socketed Pipes 124 75Mm Diametre 125 110 Mmdiametre 126 Providing And Fixing On Wall Face Un-Plasticized - Pvc Moulded Fittings / Accessories For Un Plasticized Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type-Aincludingjointing With Seal Ring Conforming To Is : 5382 Leaving 10 Mmgap For Thermal Expansion 127 Coupler 75 Mm 128 Coupler 110 Mm 129 Single Push Fit Coupler 75 Mm 130 Single Push Fit Coupler110 Mm 131 Single Tee With Door 75X75x75 Mm 132 Single Tee With Door 110X110x110 Mm 133 Single Tee Without Door75x75x75 Mm 134 Single Tee Without Door 110X110x110 Mm 135 Bend 87.5° 75 Mm Bend 136 Bend 87.5° 110 Mm Bend 137 Shoe ( Plain ) 75 Mm Shoe 138 Shoe ( Plain ) 110 Mm Shoe 139 Providing And Fixing Un-Plasticised -Pvc Pipe Clips Of Approved Design To Un-Plasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Carse Sand ) And Making Good The Wall Etc. Complete. 140 75Mm 141 110 Mm 142 Providing And Fixing To The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diametre And Weighing Not Less Than 440 Grams. 143 Supply P / Fcomputerised Name Plates Of On Acp / Hylem Sheets / Pvc Incl Computerised Writing In Approved Font, Color Design Complete Job. 144 Add Mechanical Carriage 145 Coarse Aggregates For An Average Lead Of 15 Kms 146 Fine Aggregates For An Average Lead Of 15 Kms 147 Bricks For An Average Lead Of 15 Kms 148 Stone For An Average Lead Of 25 Kms

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 20-Jul-2023 date extension Date 26-07-2023

Key Value

Document Fees
INR 10000 /-
EMD
INR 1209180.0 /-
Tender Value
INR 6.04 Crore /-

BOQ Items

Name of Work: Balance items of Work for Completion of Ftr. BSF Admin Block at BSF Humhama. Estimated Cost Rs. 604.59 Lacs
Sl. No. Item Description
1Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspitsand the like not exceeding 10 sqm on plan, including dressing of sides andrammingofbottomsliftupto1.5m,includinggettingoutexcavatedearthand disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of soil
2Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding30cmindepth,1.5minwidthaswellas10m2onplan)including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil.
3Extrafor everyadditionalliftof1.5morpartthereofinexcavation/banking excavated or stacked material : All kinds of soil :
4Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil.
5Providing and laying of stone soling (hand packed) in excavated trenches including carriage by mechanical transport at site of work.
6Supplyingandfillinginplinthwithfinesandunderfloorsincluding,watering, ramming, consolidatingand dressing complete.
7CEMENT CONCRETE (CAST-IN-SITU) Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:
81:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
91:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
10Reinforcedcementconcreteworkinwalls(anythickness)includingattachedpilasters, buttresses,plinthandstringcourses,fillets,columns,pillars,piers,abutments,postsand struts uptofloorfivelevelincludingcuringbutexcludingcostofcenteringshuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
11Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
12Steel reinforcement forR.C.C.work including straightening, cutting, bending, placing in position and binding all complete above plinth level
13Thermo-Mechanically Treated bars of grade Fe-500D or more.
14FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for:
15Suspended floors, roofs, landings, balconies and access platform with waterproofing ply 12 mm thick
16Lintel, beams, plinth beams, girders, bressumers and cantilevers with waterproofing ply 12 mm thick
17Columns, pillars, piers, abutments, posts and struts.
18Spiral staircases (including landings)
19Edges of slabs and breaks in floors and walls Under 20 cm wide
20Brickworkwithcommonburntclay(non-modular)bricksofclassdesignation 7.5in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
21Extra for brick work with common burnt clay bricks/ cement concrete bricks in superstructure above plinth level upto floor five level
22Qty vide above window minus Steps-WT-ST
23Extra for brick work in: Square or rectangular pillars
24Qty vide above window extrude
25Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : Cement mortar 1:3 ( 1 cement : 3 coarse sand)
26Extra for half Brick masonry in superstructure above plinth level upto floor V level.
27Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Zsections and other sections of approved make conforming to IS: 733 and IS:1285,fixedwithdashfastenerofrequireddia.andsizeincluding necessary filling up of gaps at junctions i.e, at top, bottom and sides withrequiredEPDMrubber/neoprenegasketfeltetc.Aluminumsections shallbesmooth,rustfree,straight,mitredandjointedmechanically whereverrequiredincludingcleatangle,Aluminumsnapbeadingfor glazing / panelling, C.P. brass / stainless steel screws, all complete as perv architectural drawings and the directions of Engineer-in-Charge (glazing,panelling and dash fasteners to be paid for separately.)22.1.1For fixed portion
28a) Polyesterpowdercoatedaluminum(minimumthicknessof polyester powder coated 50 microns) b)For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)
29Polyesterpowdercoatedaluminum(minimumthicknessof polyester powder coated 50 microns)
30Providingandfixingglazinginaluminumdoor,window,ventilator shuttersandpartitionsetc.withEPDMrubber/neoprenegasketetc. complete as per the architectural drawings and the directions of engineer- in-charge. (Cost of aluminum snap beading shall be paid in basic item.)Withfloatglasspanesof5.0mmthickness(weightnotless than 12.50 kg / sqm)
31With float glass panes of 8 mm thickness (weight not less than 20.0 kg/sqm)
32With Galvanized M.S. Wire gauge with wire of dia 0.63 mm With 12 mm mild steel U beading
33Providing and fixing of 4mm thick ACP sheets in two layers for door shutters including EPDM rubber/neoprene gasket and Snap Beading etc complete job. Qty Doors item 16 - item 20
34Providing&fixingstainlesssteel(SS-304grade)adjustablefriction windows stays of approved quality withnecessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete 255x19mm
35Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality)for aluminium doors including necessary cutting and making good etc. complete.
36Providingandfixingaluminumcasementwindowsfastnerofrequired length for aluminum windows with necessary screws etc. Complete. Powder coated minimum thickness 50 micron aluminum
37Dry random rubble masonry with hard stone in foundation and plinth: With bond stone. Without bond stone
3815mmCementplaster ontheroughsideofsingleorhalfbrickwallof mix:1 : 6 ( 1 cement : 6 fine sand)
3920mm Cement plaster of mix:1 : 6 ( 1 cement : 6 fine sand)
406MM CEMENT PLASTER 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
41Providing&fixingfalseceilingatallheightswithGRG(GlassFibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture,designandpatternshavingmoisturecontentlessthan2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustibleasperBS476(part4)-1970andlightreflectanceof85% (minimum) to be laid in true horizontal level suspended on inter-locking metalT-Gridofhotdippedgalvanisedironsectionof0.33mmthick (galvanized@ 120grams persqm including bothsides)comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32mmoflength1200mmandsecondaryintermediatecross-Tof size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeterwall angle of size 24x24x0.40 mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mmcentertocenterand40mmlongdrywallwoodscrews.The workshallbecarriedoutasperspecifications,drawingandasper directions of the Engineer-in-Charge. Withsemiperforated12mmthickmicrotegularedgedGRG false ceiling tiles.
42With fully perforated 12 mm thick micro tegular edged or 10 mm thick square edged GRG false ceiling tiles.
43Providing and applyingwhitecement based putty of specified thickness, ofapprovedbrandandmanufacturer,overtheplasteredwallsurfaceto prepare the surface even and smooth complete. 1 mm thick
442 mm thick
45CERAMIC GLAZED TILES ProvidingandfixingIstqualityceramicglazedwalltilesconformingtoIS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
46Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness tobespecifiedbythemanufacturers)of1stqualityconformingtoIS: 15622 of approved make, laidon 20 mm thick bed of cement mortar 1: 4 (1cement:4coarsesand)includingpointingthejointswithwhite cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown.In all colours, shades, except White, Ivory, Fume Red Brown
47VITRIFIED FLOOR TILES Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. completeSize of tile 600x600 mm
48Providing and fixing gang saw cut, mirror polished, premoulded and prepolished, machine cut forkitchen platforms,vanity counters,window sills, facias and similar locations, of requiredsize,approvedshade,colourandtexturelaidover20mmthickbasecement mortar1:4(1cement:4coarsesand),jointstreatedwithwhitecement,mixedwith matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour or shade
49(Area of slab over 0.5 sqm)
50Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over20mm(average)thickbaseofcementmortar1:4(1cement:4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurryadmixed with pigment of matching shade including rubbing,curingandpolishingetc.allcompleteasspecifiedandas directed by the Engineer-in-Charge.PolishedGranitestoneslabjetBlack,CherryRed,Elite Brown, Cat Eye or equivalent. Block-A, B, C (Room Floors) Qty vide item-5
51Providingedgemouldingto18mm/16mmthickmarblestonecounters,Vanitiesetc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
52Granite Work
53Providingandlayingwaterproofingtreatmentinsunkenportionof WCs,bathroometc.,byapplyingcementslurrymixedwithwater proofing cement compound consisting of applying : (a)Firstlayerofslurryofcement@0.488kg/sqmmixedwithwith waterproofingcementcompound@0.253kg/sqm.Thislayerwillbe allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed Therateincludespreparationofsurface,treatmentandsealingofall joints,corners,junctionsofpipesandmasonrywithpolymermixed slurry to air cure for 4 hours followed with water curing for 48 hours.
54Providingandfixingstainlesssteel(Grade304)railingmadeofHollow tubeschannels,platesetc.includingwelding,grinding,buffing,polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab withsuitablearrangementasperapprovalofEngineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
55Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
56Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
57FinishingwallswithtexturedexteriorpaintofrequiredshadeonNew work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
58Providing and fixing of KHATAM BANDI ceiling of first class budloo/fir wood excluding the cost of frame work which is to be paid separately.
59Chaar Gul
60Providing wood work in frames of false ceiling, partitions etc. sawn and fixed inposition :
61Kiln seasoned and chemically treated hollock wood
62Providingandfixingplainliningwithnecessaryscrews/nuts&bolts/nails, includingacoatofapprovedprimerononeface,andfixedonwooden/steel frame work, complete as per direction of Engineer-in-charge (Frame work shall be paid for separately). 12mm thick commercial ply conforming to S : 1328 BWR type
63Providing and fixing of 10mm thick laminated wooden flooring/wall pannel (AC4) of approved make ,shade and design includingprovidingthermocol sheeting of required thickness underneath wooden flooringincluding cost of door profile, Conceave beading and cornices complete job.
64Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of thesheetandpolyestertopcoat15-18microns. Sheetshouldhave protectiveguardfilmof25micronsminimumtoavoidscratchesduring transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, raftersand trusses and includingcuttingto size and shape wherever required.
65Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
66ACCESSORIES Providingandfixingprecoatedgalvanisedsteel sheetroofing accessories0.50mm(+0.05%)totalcoatedthickness,Zinccoating120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primeronbothsideofthesheetandpolyestertopcoat15-18microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
67Providing and fixing plained eaves boarding.
68250x32 mm (nominal size )2nd class kail wood
69Providing and fixing of 12mm thick imported wooden T&G ceiling including frame work of budloo wood joists of 2"" x 1.5""section complete including cost of nails,fevicol, 3"x3" Cornice and applying oftwo coats of touch wood including scaffolding and stagging charges.
70Providing & fixing soil, waste and vent pipes conforming to IS-13592 & fittings (IS-14735) suitable to rubber ring , jointing , junction , clean-out plug , cowls , offsets , collar , MS holder bat clamp , access pieces , trap of self cleaning design etc . Complete including jointing, (Type-Bof Standard quality ISI marked).
71(i)40mmOD pipe
72(ii)75mmOD pipe
73(iii)110mmOD pipe
74(iv)160mmOD pipe
75Concealed pipe including painting with anti corrosivebitumastic paint, cutting chases and making good the wall:
7615 mm dia. nominal bore
7720 mm dia. nominal bore
78ProvidingandfixingG.I.pipescompletewithG.I.fittingsincluding trenching and refilling etc. (external work)
7925 mm dia. nominal bore
8032 mm dia. nominal bore
8140 mm dia. nominal bore
82Providing and fixing ball valve (brass) of approved quality,High or low pressure, with plastic floats complete
8315 mm nominal bore
8420 mm nominal bore
8525 mm nominal bore
86Providingandfixinggunmetalnon-returnvalveofapprovedquality (screwed end)
8732 mm nominal bore
8840 mm nominal bore
89Providing and placing on terrace (at all floor levels) polyethylene water storagetankISI : 12701 marked,with cover and suitable locking arrangementandmaking necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
90Tanki Nipple 25mm
91Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay (non modular) bricks
92Cutting holes up to 15x15cm in R.C.C. floors and roofs for passing drain pipeetc.andrepairingtheholeafterinsertionofdrainpipeetc. with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 gradedstone aggregate20mm nominalsize),includingfinishingcompletesoasto make it leak proof.
93C.P. BRASS FITTINGS Providingandfixing15mmnominalboreC.P.brassbibcockof approved quality conforming to IS : 8931
94Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931
95Providingandfixing15mmnominalboreC.P.brassanglevalvefor basin mixer and geyser points of approved make conforming to IS : 8931
96Providingandfixing15mmnominalboreofstandardbacktypeC.P. brasscloseholebasinmixerpillartapofapprovedqualityandmake, weighing not less than 1.970 kg.
97Providing and fixing PTMT grating of approved quality and colour.
98Rectangular type with open able circular lid. 150 mm nominal size square 100 mm diameter of the inner hinged round grating.
99Providing and fixing PTMT soap dish holder having length of 138mm, breadth102mm,heightof75mmwithconcealedfittingarrangements, weighing not less than 106gms.
100Providing and fixing un plasticized P.V.C. connection pipe withPTMT nuts, collars and bush of approved quality and colour 15 mm nominal bore with 45 cm length.
101roviding and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to 1S:7231, with all fiings and fixtures complete, including cutting and making good the walls and floors wherever required: 18.2.1 W.C. pan with 1SI marked white solid plastic seat and lid.
102Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
103Providing and fixing wash basin with15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutling ad making good the walls wherever required complee job (a) White Vitreous Chia Wash basin size 550x400 nm with a 15 mm CP Brass single hole basin mixer
104Providing & fixing stainless steel ISI-304(18/8) Kitchen sink as per IS-13983 with CI brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required 600x450mm bowl depth 200mm(standard make).
105Providing & fixing CP15mm nominal bore Sink mixer incl acessories(ISI make) of Make and Type to be approved by Engineer In charge
106Providing and fixing P,V.C. waste pipe Flexible pipe for sink or wash basin including P.V.C waste fittings complete: 40mm dia
107Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.l. camps complete, inciuding painting of fittings and brackets, cutting and making good the walls and floors wherever required:
108Range of three urinal basins with 10 liter white P.V.C automatic flushing cistern.
109Range of four urinal basins with 10 liter white P.V.C automatic flushing cistern.
110Providing & fixing White urinal partitions of350x675x130mm size includingfittings and brackets, cutting and making good the walls and floors wherever required) standard make
111poviding and fixing 8 mm dia C.P./ S.S. Jet with flexible tube upto I metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer-in-charge.
112Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass serews and washers complete.
113Providing and fixing 600x 120x5m glass shelf with edges round off Supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long serews. rawl plugs. ctc. Complete
114Providing and fixing toilet paper holder C.P. brass
115providing and fixing PTMT Waste Coupling for wash basin and sink. Of approved quality and colour: Waste coupling 31mm of 79 mm length and 62 mm breadth weight not less than 45gms.
116Providing & fixing Towel rail C.P. brass 600 x20 mm together with a pair of each C.P. brass brackets to fit the size of towel rail(ISI make).
117Providing & fixing Towel Ring C.P. brass (ISI make)
118Providing & fixing CP Health faucet (abulation spray) (ISI make) complete including chain etc.
119Providing & fixing CP gratings (Jali) anti-cockroach of standard qualitycomplete job.
120ConstructingbrickmasonrychamberforundergroundC.I.inspection chamber and bend with common burnt clay (non modular) bricks of class designation7.5incementmortar1:4(1cement:4coarsesand)C.I. coverwithframe(lightduty)455x610mminternaldimensions,total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement :1½ coarse sand:3gradedstone aggregate20mmnominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate40mmnominalsize),insideplastering12mmthickwith cementmortar1:3(1cement:3coarsesand)finishedsmoothwitha floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line-
121Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
122Providingandfixing15cmwide45cmoverallsemicircularplainG.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete.0.63 mm thick with zinc coating not less than 275 gram/m2
123Providingandfixingonwallfaceun-plasticizedRigidPVCrainwater pipesconformingtoIS:13592TypeA includingjointingwithsealring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes
12475mm diametre
125110 mmdiametre
126Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type-Aincludingjointing with seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansion
127Coupler 75 mm
128Coupler 110 mm
129Single push fit coupler 75 mm
130Single push fit coupler110 mm
131Single tee with door 75x75x75 mm
132Single tee with door 110x110x110 mm
133Single tee without door75x75x75 mm
134Single tee without door 110x110x110 mm
135Bend 87.5° 75 mm bend
136Bend 87.5° 110 mm bend
137Shoe (plain)75 mm shoe
138Shoe (plain) 110 mm shoe
139Providing and fixing un-plasticised -PVC pipe clips of approved design to un-plasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 carse sand) and making good the wall etc. complete.
14075mm
141110 mm
142Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
143Supply P/fComputerised Name plates of on ACP/ Hylem Sheets/PVC incl Computerised writing in approved font, Color Design Complete job.
144Add Mechanical Carriage
145Coarse Aggregates for an average lead of 15 kms
146Fine Aggregates for an average lead of 15 kms
147Bricks for an average lead of 15 kms
148Stone for an average lead of 25 kms
Disclaimer :