Tender For Annual Maintenance Contract For Maintenance/Repairing Of Electrical/Electronics And Mechanical Worksof Various Assets Of Directorate Of Tourism ( Kashmir) For The Year 2023-24, srinagar-Jammu And Kashmir

Department Of Tourism has published Tender For Annual Maintenance Contract For Maintenance/Repairing Of Electrical/Electronics And Mechanical Worksof Various Assets Of Directorate Of Tourism ( Kashmir) For The Year 2023-24. Submission Date for this Tender is 15-07-2023. Electrical Maintenance Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38556820
Tender For Annual Maintenance Contract For Maintenance/Repairing Of Electrical/Electronics And Mechanical Worksof Various Assets Of Directorate Of Tourism ( Kashmir) For The Year 2023-24
Open Tender
Indian
Jammu And Kashmir
srinagar
15-07-2023

Tender Details

Tender For Annual Maintenance Contract For Maintenance / Repairing Of Electrical / Electronics And Mechanical Worksof Various Assets Of Directorate Of Tourism ( Kashmir ) For The Year 2023-24-- 1 Laying And Jointing Pvc Pipe. Heading 2 Supply , Installation Testing And Commissioningof Energy Saving Led Lamps Havell / C&S / Philips Make . 3 A ) 12 Watt 4 B ) 15 Watt 5 C ) 30 Watt 6 S / F Testing And Comm. Of Surface Mounted Led Batten 18 Wattcommercial Series ( Cool / Warm ) 4 Ft. Philips Make / Havell / Crompton Make Of Eq. Standard. Sample To Be Approved By The Engineer Incharge. 7 Supply Fixing Testing And Comm. Of McbSlegrand / Schenieder / Hager / Crabtreemake. 8 A ) 40-63 Amp. Dp Mcb. 9 B ) 16-32 Amp. Sp Mcb 10 C ) 40-63 Amp Tpn Mcb 11 Supply Installationtesting And Comm.Ofmccblegrand / Schenieder Make. 12 A ) 100 Amp 4 Pole 25 K 13 B ) 160 Amp 4 Pole 36 K 14 C ) 250 Amp 4 Pole 36 K 15 D ) 630 Amp 4 Pole 36 K 16 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor ( Havell / Anchor / Eq. Make ) Single Core Cable In Surface / Recessed Medium Class Pvc Conduit ( Anchor / Alba Make ) , With Modular Switch ( Anchor Roma Urban / Eq. Make ) , Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 17 Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor ( Havell / Anchor / Eq. Make ) Single Core Cable In Surface / Recessed Medium Class Pvc Conduit ( Anchor / Alba Make ) , Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. 18 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit ( Anchor / Alba / Eq. Make ) Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 19 25Mm 20 S / F Testing And Comm.Of Pvc Insulatedmultistranded Copper Wirehavell / Anchor / Equivalentmake. 21 A ) 1Mm Sq 22 B ) 1.5 Mm Sq 23 C ) 2.5 Mm Sq 24 D ) 4 Mm Sq 25 E ) 6 Mm Sq 26 Supply Fixing Testing And Comm.Of 16 Amp Switchssk / Anchor Make. 27 Supply Fixing Testing And Comm.Of 16 Amp Socketssk / Anchor Make. 28 Supply Fixing Testing And Comm.Of 6 Amp Switchssk / Anchor Make. 29 Supply Fixing Testing And Comm.Of 6 Amp 3 / 2 Pinsocketssk / Anchor Make. 30 Providing And Fitting Of 15 Amp Ss Combinessk / Anchor Make. 31 Providing And Fittting Of 15 Amp 3 Pin Topssk / Anchor Make. 32 Providing And Fittting Of 6 Amp 3 Pin Topssk / Anchor Make. 33 Supply Fixing Testing And Comm. Of Backlite Holder / Batten Holder / Angle Holder / Ceiling Rose Ssk / Anchor Make Incl. Pvc Block. 34 S / F / T / C Of 2 Kw 250 Volt Heating Element For Geyser . 35 S / F / T / C Of250 Volt Thermostat For Geyser . 36 S / F / T / C Of Heat Convectors Fitted With Top Bajaj / Warmex / Standard Make. 37 Providing And Fixing Of 48 Sweep Ceiling Fan Usha / Havell Make With Iron Hook. 38 Providing And Fixing Of Wall Fan Usha / Havell Make. 39 Replacement Of Det. Electrolyte In Invertor Battery And Charging . 40 S / F / T / C Of 300Mmex. Fan Usha / Havell / Standard Make. 41 Supply Fixing Testing And Comm.Of 10 Watt Led Bulk Head Philips / Havell / Eq.Standard Make. 42 S / L , Testing And Commissioning Of Pvc Alluminium Armoured Cable11000 Volt Grade Al. Armoured Cable Havell / Polycab / Eq. Standardmake 43 A ) 10 Sq.Mm 4 Core 44 B ) 16 Sq.Mm 4 Core 45 D ) 35 Sq. Mm 3.5 Core 46 E ) 50 Sq. Mm 3.5 Core 47 F ) 70 Sq. Mm 3.5 Core 48 Earth Work Excavation 70%Hard Rock And 30 % Soft Soil For Cable Trench, 2 Ft Deep With An Average Breadth Of 1.5Ft Including Refilling Of Trench With Excavated Earth After Laying Of Cable And Ramming It Properly Excluding Cost Of Cable.The Job Also Includes Laying Of Warning Tapeand Sand Layer Below And Above The Cable. 49 Supply Fixing Testing And Comm.Of Automatic Stabilizer Of Following Capacities Alba / Electricfield / Eq. Standard Make. 50 A ) 1 Kva 51 B ) 2 Kva 52 C ) 3 Kva 53 D ) 5 Kva 54 Supply Installation Testing And Comm.Of Single Phase Monoset Water Pump Of Following Capacitiescrompton / Eq. Standard Make Withoperating Voltg 180-240 Volts. Including Allied Civil And Electric Works Complete Job, 55 A ) 0.75Hp 56 B ) 1 Hp 57 C ) 2 Hp 58 Supply Installation Testing And Comm.Of16 Amppower Extension Box ( 1 No. 6 Amp Switch, 1 No. 16 Amp Switch, 3 No. 6 Amp Multi Socket And 1 No.6 / 16 Socket ) With Suitable Size Lead And Top. C&S Make. 59 Providing And Fixing Of Hylum Sheet. 60 S / I / T / C Ofac / Dc Electronic Bell Complete Standard Make. 61 Supply Installation Testing And Commissioning Of Chordless Bell Standard Make 62 Supply Of Deisel Oil For Running Of Generator. 63 Providing Of Petrol For Gen. Sets. 64 Providing And Fixing Of Al.Thimble 10-35Mm Sq. 65 Supply Fixing Testing And Comm.Of Baklite Cable Connector 63 Amp. 66 Supply, Laying Overhead, Testing And Comm. Of 16Mm2 Core 650 / 1100 V Grade Unarmoured Aluminium Cable Havell / Polycab / Eq. Standard Make. 67 Supply Installation Testing And Comm. Of1X1X1.6 Control Pannel Sheet Steel Powder Coated Phosphatised Having Angle Iron Stand Fitted With Following Accessories To Be Grouted In The Cement Concrete, Complete Job 68 A ) 200 Amp 4 Strip Bus 1 No.B ) A / V Meters Set / Indicators 69 Supply Fixing Testing And Comm.Ofdecorative Luminaries Glomac / Eq. Standard Make Complete With 15 Watt Led Lamp Havell Make. 70 Supply Installation Testing And Comm. Ofstreetlighting Luminaire 120W Led Environmental Friendly Long Life Versatile Pressuredie-Cast Aluminium Ip66with High Power Led As Light Sourcehavell ( Endurra Cityliner Neo ) / Philips / Crompton / Eq. Standard Make. 71 Supply Installation Testing And Comm. Ofstreetlighting Luminaire 60W Led Environmental Friendly Long Life Versatile Pressuredie-Cast Aluminium Ip66with High Power Led As Light Sourcehavell ( Endurra Cityliner Neo ) / Philips / Crompton / Eq. Standard Make. 72 Supply Installation Testing And Comm. Ofdie Cast Aluminium Ip66 Flood Light 300 W With High Power LedS As Light Source Streetlighting Luminairephilips / Havell ( Jeta Iris ) / Eq. Standard Make 73 Supply Installation Testing And Comm. Of Flood Light 150 W ( 16500 System Lumens ) , Epoxy Powder Coated Die-Cast Aluminium Housing ( Lm24 ) With Elegantly Designed Heat Sink For Efficient Thermal Management, Sturdiness & Excellent Corrosion Resistant. Pg9 Gland Is Used For Cable Entry And Provision For Loopin-Loopout Class 1, Ip66, Ik 07, , With High Power LedS As Light Source With Built-In Potted Ip67 Electronic Led Driver With Apfc, Lower Thd, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection Upto 10Kv With Built In Spd & Other Safety Test As Per Is 15885 Part-2 / Sec 13, Iec60598-1.Preferred Make:Philips / Havell / Wipro / Crompton Make 74 Supply Installation Testing And Comm. Ofdie Cast Aluminium Ip66 Flood Light 50 W With High Power LedS As Light Source Streetlighting Luminairephilips / Havell ( Jeta Compacto ) / Eq. Standard Make 75 S / F Testing And Comm. Of ( Cool / Warm ) Recessed / Surface Mounted Ceiling 15 Wattled Down Lighters Pressure Die Cast Aluminium Luminaire In Powder Coated White Finish With Optimized Heat Sink For Efficent Heat Dissipation ( Commercial Series Of Approved Make ) Philips / Havell / Crompton Make Of Eq. Standard. 76 Supply And Fixing Of 0Neway Arm Bracket For Mounting The Luminaire On The Top Of The Pole / With The Wall Etcfabricated Out Of0.9Mt Long, 35Mm Diameter M.S. Pipe, Along With Iron Clips, Nuts And Bolts For Holding The Luminarie. 77 Supply Installation Testing And Comm.Of35 Lit. Geyserhindware / Venus / Jaguare Make Includingmaking Good The Damage, C.Pconnection, Geyser Boltsetc. Plumbing And Civil Woks As Required. 78 Supply Installation Testing And Comm.Of50 Lit. Geyserhindware / Venus / Jaguare Make Includingmaking Good The Damage, C.Pconnection, Geyser Boltsetc. Plumbing And Civil Woks As Required. 79 Supply Installation Testing And Comm.Of Invertor Battery 180 Ah / 12 V Exide Invatubular / Su-Kam / Luminous Make. 80 Supply Installation Testing And Comm.Of Inverter Of Following Ratingmicrotek / Sukam / Luminous Make. ( Strictly As Per Approved Sample ) 81 A ) 900 - 1100 Va 82 B ) 1400-1600 Va 83 Supply Installation Testing And Comm.Of Air Conditioner Hot And Cold 1.5 Tr Daikin / Mitshubishi / Equivalent Make ( Inverter Technology Type ) .The Job Also Includes Cabling Andthe Civil Works By Way Of Drilling And Making Adequate Space In The Wall For Laying Of Copper Pipes, Wiresetc.Including Its Accessoriesrefinishing To Its Original Condition. ( Complete Job ) 84 Supply Installation Testing And Comm. Ofstreetlighting Luminaire 30W Led Environmental Friendly Long Life Versatile Pressuredie-Cast Aluminium Ip66with High Power Led As Light Sourcehavell ( Endurra Cityliner Neo ) / Philips / Crompton / Eq. Standard Make. 85 Supplying And Drawing Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 86 Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 87 Providing And Fixing Earth Bus Of 50 Mm X 5 Mm Copper Strip On Surface For Connections Etc. As Required. 88 Supplying And Making Straight Through Joint With Heat Shrinkable Kit Including Ferrules And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 89 4 X 16 Sq. Mm 90 3½ X 35 Sq. Mm 91 Erection Of Metallic Pole8.0 Metre And Upto 10.0 Metrein Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) Foundation Including Excavation And Refilling Etc. As Required. 92 Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump, Dg Set Etc Including Form Work Etc As Required 93 Providing Brick Work ( In Width 225 Mm Or More ) With F.P.S. Bricks Of Class Designation 7.5 In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) At All Levels. 94 Providing 15Mm Thick Cement Plaster Of Mix 1:4 ( 1 Cement : 4 Fine Sand ) At All Levels. 95 Supply And Errection Of8.0 Mt Long ( 410Sp-14 ) Steeltubular Poles, Sawaged Typeconforming To Is-2713, ( Part-Ii ) , Planting Depth 1.5 Mt .Pole Shall Have 2 No Bolts Welded Ata Distance Of 3 Mt. From Bottom Of Pole And Suitable Holes Shall Be Drilled In Pole For Service Connection And Lum. Earth Wires. 96 Painting Of Pole With One Coat Of Red Oxide And Two Coats Of Al. Paint. 97 Supply And Errection Of9.0 Mt Long ( 410Sp-33 ) Steeltubular Poles, Sawaged Typeconforming To Is-2713, ( Part-Ii ) , Planting Depth 1.5 Mt .Pole Shall Have 2 No Bolts Welded Ata Distance Of 3 Mt. From Bottom Of Pole And Suitable Holes Shall Be Drilled In Pole For Service Connection And Lum. Earth Wires. 98 Engaging Of Skilled Labour For Dismentalling Of Old / Defunct Material And Also For Carrying Out Other Allied Works. 99 S / F / T / C Ofthree Phase4 Wire Energy Meter 100Ampsecure / Equivalent Makeand Kiosk Of Suitable Size To Houseenergy Meter. The Kiosk Is To Be Fitted On The Pole / Wall With The Help Of Clamps. .Complete Job. 100 S / F / T / C Of Single Phase Energy Meter 60-80 Ampsecure / Equivalent Makeand Kiosk Of Suitable Size To Houseenergy Meter. The Kiosk Is To Be Fitted On The Pole / Wall With The Help Of Clamps. .Complete Job. 101 Supply Laying , Testing And Commissioning Of Pvcsheathed Alluminiumcable Un Armoured 1100 Volt Grade Al. Cable Havel / Eq. Standardmake..The Job Also Includes The End Termination Of Cables By Suitable Size Lugs And Connecting The Same With The Main Line. 102 A ) 95Sq. Mm Single Core 103 Supply Installation Testing And Comm.Of Class 1.0 Accuracy Classstatic 3 Phase-4Wire Three -Vectorprodgeyenergy Meter , Having Current Range 40-200 A Secure / Equivalent Make. The Meter Shall Be Suitable For Measurement Of Energy And Power , Demand Requirement In An Ac Balanced / Unbalanced System Over A Power Factorrange Of Zero Lag To Unity. These Meters Should Have Additional Communication Port For Wireless Remote Meter Reading. ( Complete Job )

Key Value

Document Fees
INR 800 /-
EMD
INR 46000.0 /-
Tender Value
INR 23 Lakhs /-

BOQ Items

Name of Work:Annual maintenance contract forMaintenance/Repairingof Electrical/Electronics and Mechanical worksof variousassets of Directorate of Tourism ( Kashmir) for the year 2023-24.
Sl. No. Item Description
1Laying and Jointing PVC Pipe. Heading
2Supply , installation testing and commissioningof energy saving LED lamps Havell/C&S/Philips make .
3a) 12 Watt
4b) 15 Watt
5c)30 Watt
6S/F testing and comm. Of surface mounted LED Batten 18 wattcommercial series (cool/warm) 4 ft. Philips make /Havell/ Crompton make of eq. standard. sample to be approved by the engineer incharge.
7Supply fixing testing and comm. Of MCB"sLegrand /Schenieder/Hager/Crabtreemake.
8a) 40-63 amp. DP MCB.
9b) 16-32 amp. SP MCB
10c) 40-63 amp TPN MCB
11Supply installationtesting and comm.ofMCCBLegrand/Schenieder make.
12a) 100 amp 4 pole 25 K
13b) 160 amp 4 pole 36 K
14c) 250 amp 4 pole 36 K
15d) 630 amp 4 pole 36 K
16Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Anchor/ Eq. make) single core cable in surface / recessed medium class PVC conduit ( Anchor/ Alba make), with modular switch ( Anchor roma urban/ Eq. make), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
17Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor ( Havell/Anchor/ Eq. make) single core cable in surface/recessed medium class PVC conduit ( Anchor/ Alba make), alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
18Supplying and fixing of following sizes of medium class PVC conduit ( Anchor/ Alba/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
1925mm
20S/F testing and comm.of PVC insulatedmultistranded copper wireHavell/Anchor/Equivalentmake.
21a) 1mm sq
22b)1.5 mm sq
23c) 2.5 mm sq
24d) 4 mm sq
25e) 6 mm sq
26Supply fixing testing and comm.of 16 amp switchSSK /Anchor make.
27Supply fixing testing and comm.of 16 amp socketSSK /Anchor make.
28Supply fixing testing and comm.of 6 amp switchSSK /Anchor make.
29Supply fixing testing and comm.of 6 amp 3/2 pinsocketSSK /Anchor make.
30Providing and fitting of 15 amp SS combineSSK / Anchor make.
31Providing and fittting of 15 amp 3 pin topSSK/anchor make.
32Providing and fittting of 6 amp 3 pin topSSK/anchor make.
33Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor make incl. PVC Block.
34S/F/T/C of 2 KW 250 Volt heating element for geyser .
35S/F/T/C of250 Volt thermostat for geyser .
36S/F/ T/C of heat convectors fitted with top Bajaj/warmex/Standard make.
37Providing and fixing of 48" sweep ceiling fan Usha/Havell make with iron hook.
38Providing and fixing of wall fan Usha/Havell make.
39Replacement of Det. Electrolyte in invertor battery and charging .
40S/F/T/C of 300mmEx. Fan USHA/ Havell/ Standard make.
41Supply fixing testing and comm.of 10 watt LED Bulk Head philips/Havell/eq.standard make.
42S/L , testing and commissioning of PVC alluminium armoured cable11000 volt grade Al. armoured cable Havell/polycab/Eq. standardmake
43a) 10 sq.mm 4 core
44b) 16 sq.mm 4 core
45d) 35 sq. mm 3.5 core
46e) 50 sq. mm 3.5 core
47f) 70 sq. mm 3.5 core
48Earth work excavation 70%hard rock and 30 % soft soil for cable trench, 2 ft deep with an average breadth of 1.5ft including refilling of trench with excavated earth after laying of cable and ramming it properly excluding cost of cable.the job also includes laying of warning tapeand sand layer below and above the cable.
49Supply fixing testing and comm.of automatic stabilizer of following capacities Alba/Electricfield/Eq. Standard make.
50a) 1 KVA
51b) 2 KVA
52c) 3 KVA
53d) 5 KVA
54Supply installation testing and comm.of single phase monoset water pump of following capacitiescrompton/eq. standard make withoperating voltg 180-240 volts. Including allied civil and electric works complete job,
55a) 0.75HP
56b) 1 HP
57c) 2 HP
58Supply installation testing and comm.of16 amppower extension box ( 1 No. 6 amp switch,1 No. 16 amp switch, 3 No. 6 amp Multi socket and 1 No.6/16 Socket) with suitable size lead and top. C&S make.
59Providing and fixing of Hylum Sheet.
60S/I/T/C ofAC/DC Electronic Bell complete standard make.
61Supply installation testing and commissioning of chordless Bell standard make
62Supply of Deisel oil for running of Generator.
63Providing of Petrol for Gen. sets.
64Providing and fixing of Al.thimble 10-35mm sq.
65Supply fixing testing and comm.of baklite cable connector 63 amp.
66Supply, laying overhead, testing and comm. Of 16mm2 core 650/1100 V grade unarmoured Aluminium cable Havell/Polycab/Eq. standard make.
67Supply installation testing and comm. Of1"x1"x1.6" control pannel sheet steel powder coated phosphatised having angle iron stand fitted with following accessories to be grouted in the cement concrete, complete job
68a) 200 amp 4 strip bus 1 No. b) A/V meters set/indicators
69Supply fixing testing and comm.ofdecorative luminaries Glomac/Eq. standard make complete with 15 Watt LED lamp Havell make.
70Supply installation testing and comm. ofStreetlighting luminaire 120W LED environmental friendly long life versatile pressuredie-cast aluminium IP66with high power LED as light sourceHavell ( Endurra Cityliner NEO)/ Philips/ Crompton/ Eq. Standard make.
71Supply installation testing and comm. ofStreetlighting luminaire 60W LED environmental friendly long life versatile pressuredie-cast aluminium IP66with high power LED as light sourceHavell ( Endurra Cityliner NEO)/ Philips/ Crompton/ Eq. Standard make.
72Supply installation testing and comm. ofdie cast aluminium IP66 flood light 300 W with high power LED"s as light source Streetlighting luminairePhilips/ Havell ( JETA IRIS)/Eq. Standard make
73Supply installation testing and comm. of flood light 150 W ( 16500 System Lumens ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1,IP66, IK 07, ,with high power LED"s as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1.Preferred make:Philips/ Havell /Wipro/Crompton make
74Supply installation testing and comm. ofdie cast aluminium IP66 flood light 50 W with high power LED"s as light source Streetlighting luminairePhilips/ Havell ( JETA COMPACTO)/Eq. Standard make
75S/F testing and comm. Of (cool/warm) recessed/ surface mounted ceiling 15 WattLED down lighters pressure die cast aluminium luminaire in powder coated white finish with optimized heat sink for efficent heat dissipation ( commercial series of approved make) philips / Havell/Crompton make of eq. standard.
76Supply and fixing of 0neway arm bracket for mounting the luminaire on the top of the pole/ with the wall etcfabricated out of0.9mt long, 35mm diameter M.S. pipe, along with iron clips, nuts and bolts for holding the luminarie.
77Supply installation testing and comm.of35 lit. geyserHindware/venus/jaguare make includingmaking good the damage, C.Pconnection, geyser boltsetc. plumbing and civil woks as required.
78Supply installation testing and comm.of50 lit. geyserHindware/venus/jaguare make includingmaking good the damage, C.Pconnection, geyser boltsetc. plumbing and civil woks as required.
79Supply installation testing and comm.of invertor battery 180 AH/12 V Exide invatubular/ Su-kam /Luminous make.
80Supply installation testing and comm.of inverter of following ratingMicrotek/Sukam/Luminous make. ( strictly as per approved sample)
81a)900 - 1100 VA
82b) 1400-1600 VA
83Supply installation testing and comm.of air conditioner hot and cold 1.5 TR DAIKIN/ Mitshubishi / equivalent make( inverter technology type).the job also includes cabling andthe civil works by way of drilling and making adequate space in the wall for laying of copper pipes, wiresetc.including its accessoriesrefinishing to its original condition.( Complete job)
84Supply installation testing and comm. ofStreetlighting luminaire 30W LED environmental friendly long life versatile pressuredie-cast aluminium IP66with high power LED as light sourceHavell ( Endurra Cityliner NEO)/ Philips/ Crompton/ Eq. Standard make.
85Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
86Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
87Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
88Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
894 X 16 sq. mm
903½ X 35 sq. mm
91Erection of metallic pole8.0 metre and upto 10.0 metrein cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
92Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required
93Providing brick work (in width 225 mm or more) with F.P.S. bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) at all levels.
94Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels.
95Supply and errection of8.0 mt long(410SP-14) steeltubular poles, sawaged typeconforming to IS-2713, (Part-II) ,planting depth 1.5 mt .Pole shall have 2 no bolts welded ata distance of 3 mt. from bottom of pole and suitable holes shall be drilled in pole for service connection and lum. earth wires.
96Painting of pole with one coat of red oxide and two coats of Al. paint.
97Supply and errection of9.0 mt long(410SP-33) steeltubular poles, sawaged typeconforming to IS-2713, (Part-II) ,planting depth 1.5 mt .Pole shall have 2 no bolts welded ata distance of 3 mt. from bottom of pole and suitable holes shall be drilled in pole for service connection and lum. earth wires.
98Engaging of skilled labour for dismentalling of old/defunct material and also for carrying out other allied works.
99S/F/T/C ofthree phase4 wire energy meter 100ampSecure/equivalent makeand kiosk of suitable size to houseenergy meter. The kiosk is to be fitted on the pole/wall with the help of clamps. .Complete job.
100S/F/T/C of single phase energy meter 60-80 ampSecure/equivalent makeand kiosk of suitable size to houseenergy meter. The kiosk is to be fitted on the pole/wall with the help of clamps. .Complete job.
101Supply laying , testing and commissioning of PVCsheathed alluminiumcable un armoured 1100 volt grade Al. cable Havel/Eq. standardmake..the job also includes the end termination of cables by suitable size lugs and connecting the same with the main line.
102a)95sq. mm single core
103Supply installation testing and comm.of class 1.0 accuracy classstatic 3 phase-4wire three -vectorProdgeyenergy meter , having current range 40-200 A Secure /equivalent make. The meter shall be suitable for measurement of energy and power , demand requirement in an AC balanced/ unbalanced system over a power factorrange of zero lag to unity. these meters should have additional communication port for wireless remote meter reading. ( complete job)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail