Tender For Supply, Installation, Testing And Commissioning Of 4 Number Of 8 Meter Minimast (Motorized) With 5 Numbers Of 150 W Led Flood Lights At Vettikkavala Block Panchayath.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Jul 2023
0 days left
EMD
27500
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kollam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Supply, Installation, Testing And Commissioning Of 4 Number Of 8 Meter Minimast (Motorized) With 5 Numbers Of 150 W Led Flood Lights At Vettikkavala Block Panchayath.
BOQ
| Sl. No. | Item Description |
| 1 | Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/twosections of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mmbase plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III with head frameassembly two point suspension system with steel wire rope 5mm dia double drum winching system w andincluding round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetricalarrangement control gear box and lighting spikes with single phase operation power tool installed insidethe base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation andjunction box etc, complete 8 Meters |
| 2 | Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dustand vermin proof, cubicle type MV panel board comprising of the following components/ devices &complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panelassembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved designand requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outsfor mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus barchamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required.CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using1.6mm CRCA sheet, powder coated (excluding base frame) |
| 3 | Supply Conveyance, installation, testing and commissioning of 150W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factorgreater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-castPowder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatlyaccessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be producedmentioning chip manufacturer) |
| 4 | Supply and providing heavy duty \"A\" section neoprene gasket in the panel boardU\" section rubber beedingsuitable for 1.60/ 2.00 mm sheet |
| 5 | Supply and fixing of 2 nos.of 25A 3 Pole AC 1 rated power contactor, Selector switch for motor control,supply and fixing flush head push button NO-NC, 1.5 sq. mm ISI marked FRLS PVC insulated single corecopper conductor cable and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable. |
| 6 | Supply and fixing of 25A 2 Pole AC 1 rated power contactor, 25A Connector, Digital timer, SuitableCopper socket, 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable, 1.5 sq.mm ISI marked FRLS PVC insulated single core copper conductor cable, OBO Bettermann makes V25-B+ C/1+ NPE (switching/lightning protection) for single-phase protection. |
| 7 | Supply and fixing HRC fuse base of 20/32A using suitable nut and bolt, 32A 2-way neutral links mounted on DMC/SMC base and 2.5 sq. mm ISI marked FRLS PVC insulated single core copper conductor cable. |
| 8 | Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panelboard |
| 9 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required.40 amps |
| 10 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Double pole |
| 11 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breakersuitable for inductive load of following poles in the existing MCB DB complete with connections, testingand commissioning etc. as required.Single pole |
| 12 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB completewith connections, testing and commissioning etc. as required.40 amps |
| 13 | Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sqmm |
| 14 | Supply and clamping the following sizes of strips on surface of wall / parapet/ existing cable tray usingclamps fabricated from 20 x3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clampsnot exceeding 1 m , making good the damages, colour washing etc. as required ( for vertical run).25 x 3 mm GI strip |
| 15 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and givingconnection as required3.15 mm copper conductor ( 10 SWG) |
| 16 | Supply of superior quality copper earth socket for the following size of earth conductor including crimpingetc. as required.3.15 mm (10 SWG) |
| 17 | Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 10 sqmm |
| 18 | Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench50/38 mm or nearest size |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade asrequired.2 X 10 sq. mm (19mm) |
| 20 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavatedearth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil |
| 21 | Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40nominal size) |
| 22 | Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 23 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more |
| 24 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarsesand :3 graded stone aggregate 20 mm nominal size |
| 25 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 26 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 27 | Fabrication ,supply, conveyance and installation of Granite name board indicating the cost involved, the commencement, completion and inauguration date etc. |
| 28 | Charges for KSEB connection including all laison works (Actual Amount paid on production of receipt). |
AI Tender Summary
Tender Timeline
Jul 08, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJul 15, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 17, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender