Public Works Department-PWD has published Providing, Installation And Commissioning Of Split / Window Type Air Conditioning System As And When Emergently Required In Essential Areas Of Tripura High Court Building, New Assembly Building, Chief Justice Dakbanglow, New Secretariat Building And . Submission Date for this Tender is 19-07-2023. Air Conditioner Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Providing star rated( Minimum3star withapplicable ISEER accordingto currentindustrystandard ) split typehigh wall A C machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specificationwith hermetically sealed compressoroperating onnonCFC refrigerant as supplied with AC machine,necessaryplug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall mountingconformingtoIS (Part-II) speceification ( Except powerconsumption) suitablefor operation on 230volt,50Hz, singlephaseACsupply capable ofperforminga) Cooling b) Dehumidifyingc)Air circulating d) Filtering havingrated cooling capacity. |
2 | 1.0 TR (rated cooling capacity should not be less than 3000 Kcal/hr or 12000Bthu/ hr or 3500 watt) |
3 | 1.5 TR (rated cooling capacity should not be less than 4500 Kcal/hr or 18000 Bthu/ hr or 5250 watt) |
4 | 2.0 TR (rated cooling capacity should not be less than 6000 Kcal/hr or 24000 Bthu/ hr or 7000 watt) |
5 | Providing star rated(Minimum3star with applicable ISEERaccording to current industry standard) window type AC machine (Condenser & evaporator coil pipe should be made of copper) of approvedmakeandtechnical specificationwith hermetically sealed compressoroperatingon non CFC refrigerantpipeassupplied with AC machine,necessary plug top(With 01 year overall machineandcompressor warranty)suitable for window type conforming to IS (Part-II) specification (Except power consumption)suitable for opretionon 230 volt, 50 Hz,single phaseAC supplycapable of performinga)Coolingb) Dehumidifyingc) Aircirculating d) Filteringhaving rated cooling capacity. |
6 | 1.5 TR (rated cooling capacity should not be less than 4500cal/hr or 18000 BThu/ hr or 5250 watt) |
7 | Providing star rated( Minimum3star withapplicable ISEER accordingto currentindustrystandard ) split typehigh wall A C machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specificationwith hermeticaly sealed compressoroperating onnonCFC refrigerant as supplied with AC machine,necessaryplug top for IDU (with 01 year overall machine and compressor warranty) suitable for wall/ceiling mountingconformingtoIS (Part-II) speceification ( Except powerconsumption) suitablefor operation on 420volt,50Hz, threephaseACsupply capable ofperforminga) Cooling b) Dehumidifyingc)Air circulating d) Filtering havingrated cooling capacity |
8 | 2.5 TR (rated cooling capacity should not be less than 7500 Kcal/hr or30000 Bthu/ hr or 8750 watt) |
9 | Providing star rated( Minimum3star withapplicable ISEER accordingto currentindustrystandard ) splittype highwallA C machine (Condenser & evaporator coil pipeshould bemade ofcopper)of approvedmakeandtechnical specificationwith hermetically sealed compressoroperatingon non CFC refrigerantassupplied with AC machine,necessaryplug topforIDU (with 01 year overallmachine and compressor warranty) suitable for wall mountingconformingtoIS (Part-II) speceification ( Except powerconsumption) suitablefor opretion on 420volt,50Hz, threephaseACsupply capable ofperforminga) Cooling b) Dehumidifyingc)Air circulating d) Filtering havingrated cooling capacity. |
10 | 3.0TR (rated cooling capacity should not be less than 9000 Kcal/hr or36000 Bthu/ hr or 10500 watt) |
11 | Providing split typeceiling mountedcassette type A C machine (Condenser&evaporatorcoilpipe should be made of copper) of approved make and technical specificationwith hermeticallysealed compressoroperating on non CFC refrigerant as supplied with ACmachine,necessaryplug top for IDU (with 01 year overall machine andcompressor warranty) suitablefor ceiling mountingconformingtoIS (Part-II) specification(Except power consumption)suitable for operationon 420 volt,50Hz, threephase AC supply capable of performinga) Cooling b) Dehumidifyingc)Air circulating d) Filtering having rated cooling capacity. |
12 | 4.0TR (rated cooling capacity should not be less than 12000 Kcal/hr or48000 Bthu/ hr or 14000 watt) |
13 | Providing tower/floormounting vertical splittype A C machine (Condenser&evaporator coilpipe should be made of copper) of approved makeand technical specificationwith hermetically sealed compressoroperating on non CFC refrigerant as supplied with ACmachine,necessaryplug top for IDU (with 01 year overall machine andcompressor warranty)suitablefor wall/ceiling mountingconformingtoIS (Part-II) speceification (Exceptpower consumption) suitable foroperationon 420 volt,50Hz, three phase AC supply capableof performinga) Cooling b) Dehumidifyingc)Air circulatingd) Filtering having ratedcooling capacity. |
14 | 3.0TR (rated cooling capacity should not be less than 10500 Kcal/hr or42000 Bthu/ hr or 10500 watt) |
15 | 4.0TR (rated cooling capacity should not be less than 12000 Kcal/hr or48000 Bthu/ hr or 14000 watt) |
16 | Standardinstallation,testing and commissioningof 1.0/ 1.5 / 2.0TRsplit and window type machine including hole cutting,finishingetcas per direction of the Engineer-in-charge. |
17 | Standardinstallation,testing and commissioningof 2.5/ 3.0 / 4.0TRhigh walland ceiling mountingsplit type machineincludinghole cutting, finishiingetc.as perdirection ofthe Engineer-in-charge. |
18 | Standardinstallation,testing and commissioning of3.0 / 4.0 TR tower/ floor mountingvertical split type AC machine including hole cutting, finishing etc.as perdirection ofthe Engineer-in-charge. |
19 | FabricationofM.S. platform for placement ofcondensing unitby using M.Sangle of(65x65x5) or (50x50x5) mm sizebaseplate,nuts and bolts/ universalbracket(GSS)forODU of split type ACsincluding all accessories for onsite installationi/c painting , fitting, fixing, grouting by cement mixture as perdirection ofthe Engineer-in-charge. |
20 | Supplyinstallation ofadditionallengthofcopperpipe beyond10 fit length of 5/8"",3 /8", 1/2" and1/4"diamiter forsuctionand liquid linewith insulationandnecessarywiringbetween indoor and outdoor units. |
21 | ProvidinghardPVCpipe ofbest quality of25 mmdiameterincludingnecessary clamping and fitting for draining ofcondensate waterfromindoor unit as perdirection ofthe Engineer-in-charge. |