Tender For Upgradation Of Existing Two Vacuum Pumps Of Capacity 60 Cfm To Medical Vacuum Pump Of Capacity 150 Cfm At Govt. Smgs Hospital, Jammu., jammu-Jammu And Kashmir

Public Works Department-PWD has published Tender For Upgradation Of Existing Two Vacuum Pumps Of Capacity 60 Cfm To Medical Vacuum Pump Of Capacity 150 Cfm At Govt. Smgs Hospital, Jammu.. Submission Date for this Tender is 05-08-2023. Pump Supply Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38520728
Corrigendum : Tender For Upgradation Of Existing Two Vacuum Pumps Of Capacity 60 Cfm To Medical Vacuum Pump Of Capacity 150 Cfm At Govt. Smgs Hospital, Jammu.
Open Tender
Indian
Jammu And Kashmir
jammu
05-08-2023

Tender Details

Upgradation Of Existing Two Vacuum Pumps Of Capacity 60 Cfm To Medical Vacuum Pump Of Capacity 150 Cfm At Govt. Smgs Hospital, Jammu.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 08-Jul-2023 CORRIGENDUM Other 18-07-2023
2 18-Jul-2023 EXTENSSIONN Date 24-07-2023
3 24-Jul-2023 make corrigendium Other 24-07-2023
4 24-Jul-2023 EXTENSIONJ2 Date 31-07-2023
5 31-Jul-2023 EXTENSION3 Date 05-08-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 38000.0 /-
Tender Value
INR 18.89 Lakhs /-

BOQ Items

Upgradation of existing two Vacuum Pumps of capacity 60 CFM to Medical Vacuum Pump of Capacity 150 CFM at Govt. SMGS Hospital, Jammu
Sl. No. Item Description
1Upgradation of existing suction plant by way of supply, installation, testing and commissioning of new reciprocating air-cooledDuplex medical Vacuum Pumps, sufficient to developa vacuum of minimum 29 inch of Hg, having capacity of 150 cfm -2 No. (One working and 2nd as standby) with suitableISI marked Motor, mounted on base frame complete with starter, motor rail, motor pulley, V-belts & belt guard. Accessories for each Vacuum pump. Silencer with Union fitting and pipes 01 set, 01 NRV 54 mm, 4 brass unions 54 mm, 01 line filter with 12mm drain valve, 01 Bacteria Filter Assembly,01 ball valve 54mm, 01 vacuum pressure switch 01 set. Job includes all fittings and connections compatible to existingVacuum receiver three Tanks kept inside Old Gas Plant. All the Three Tanks are to be interconnected through 54mm pipes and couplings (three inlets and three outlets) to act as a Single Reservoir.The system will be of Automatic as well as ManualStart and Stop compatible with cascading/sequencing facilities to meet with NFPA-99 standards and CE certified. Complete job includes labour charges, transportation charges, all kinds of taxes . Make : Ingersoll Rand India/Anest iwatas
2Supply, installation, testing and commissioning ofNew Auto Cascading ELECTRICAL CONTROL PANELS for Duplex Vacuum PumpsCE MARKED The central control Panel shall be made of MS Sheet having thickness 16 SWG and should be epoxy powder coated for vacuum system conforming to ISO 9001:2015. It should be equipped with auto manual selector, DOL starters compatible to each electric motor for Vacuum pumps and equipped for duplex/cascade system for vacuum pumps having mains incomer, bus bar arrangement, voltmeter with phase indicating lights, phase loss/phase reversal indicating light, single phasing preventer, contactors, overload relays, control circuit MCB’s, start/stop push buttons, auto/manual switches, pump “on” and pump “trip” indicating lights, sequencing relays with overriding feature. having alarm for Pressure Fault caused by Pipeline vacuum less than 300 mm Hg. The system will be of Automatic as well as ManualStart and Stop compatible with cascading/sequencing facilities to meet with NFPA-99 standards and CE certified. Complete job includes labour charges, transportation charges, all kinds of taxes . All the switchgear used in this system would be of reputed make like Crompton, L&T, Siemens, etc.
3Providing and laying of Medical Grade copper pipe for Vacuumas per EN 13348:2016, (Medical Grade), Solid Drawn, Seamless, De-oxidized, Non- arsenical, half-hard fully de-greased (designated to R250). It should conform and meet with the latest BSEN 13348:2001 standard. Chemical compositions as per CUDHP to 1190-1 and CWO 24A to EN 1412. Maximum total carbon content 0.20 Mg/dms.The pipes shall be accompanied with manufactures test certificate for the Physical properties & Chemical Composition. Copper Pipes will also have third party inspection certificates from KITEMARK/LOYYDS REGISTERY SERVICES/TUV/SGS. The copper pipe should be suitably embossed with the manufacturing name/logo (Make MAXFLOW/MANDEV/METALALLOY) Specifications of Medical copper pipe is as below:- 54 mm OD x 1.2 mm thick (payment shall be made as per actual measurement) Job includes cost of bends, tee, sockets, reducers, hooks, fasteners, brazing and painting with proper colour coding and includes interconnection with existing 42mm pipeline. Complete job includes labour charges, transportation charges, all kinds of taxes .
4Providing and fitting of Ball valves with brass fitting for regulation ofVacuum at Bacteria filtersdetail as below:- 54mm Complete job includes labour charges, transportation charges, all kinds of taxes etc. Acceptable makes: L&T, ELEM, ZOLOTO/RN/RB
5• Civil work includes dismantling of walls and existing platform/foundations of Vacuum pumps and laying of new foundations and repair of walls etc.
6Fabrication, Supplying and installation of indoor type cubical LT Control panel board of suitable size made out of CRCA Sheet steel of thickness not less than 2.0 mm and shall be braced as necessary to provide a rigid support for all components. The doors and covers shall be constructed from CRCA sheet steel of thickness not less than 1.6 mm. and also paint with red oxide primer and finally with approved colour paint to be stove enameled. A base channel of appropriate size and thickness shall be provided at the bottom and also fixed to floor with proper concrete mix ratio. The bus bars shall be of aluminum having rectangular cross sections with PVC sleeving of minimum 300 Ampere capacity and colour code. The panel house insidecomponents such asthree phase 250 A, I-O-II on load Changeover Switch, 4P, 415v, 50hz (of L&T/Havels make) and all internal wiring and other components of appropriate rating and specifications like Ammeter, voltmeter, CTs etc., indication lamps(RYB) with control HRC fuse with fuse fitting-01 set for each incomer and outgoing. The three phase Output bus bars of the change-over Panel should have two outgoing, one output for auto cascading panel of Vacuum Pumps and second outputs for Auto cascading panel of Medical Air Compressors . • The Control terminals & Power terminals should be separated with necessary ferrule marking. The ammeters and voltmeters shall be provided with HRC fuses. The circuits in the panels shall be so arranged as to facilitate their operation and maintenance and at the same time to ensure the necessary degree of safety. Provision shall be made in the panel for terminating the incoming cables and all cables shall be provided with cable terminations. Provision shall also be made for permanently earthing the frames and all panels. • The job includes all types of material and labour charges and taxes thereof.
7Providing and Laying of PVC insulated and PVC sheathed /XLPE aluminum conductor power cable of 1.1 KV grade armoured cable 3.5 core x 120sq mm, 1100 volts from: 1. 1000A control panel (near ward 18 AC Machine room) to 250 A change over panel at Old gas Plant.(incoming) 2. Control Panel of 2900 LPM Oxygen Plant to 250 A change over panel at Old gas Plant. (incoming) 3. 250 A change over panel to Auto cascading panel of Vacuum Pumps and Medical Air compressors(Outgoing) For interconnections as per site requirements conforming to relevant IS Codes with latest amendments up to date of Gloster/ Havells/ CCI/ National/ Sky tone/Polycab make. The cables are to be duly carried along through fabricating M.S. cable traysincluding horizontal and vertical bends, bridges, underground laying (where required), cross members and other accessories as required and duly suspended from the ceiling/wall(where required) with M.S. suspenders, fasteners, supports, welding etc., as required. The cable ends are to be fixed with suitable heavy duty single compression brass gland SIBG type, heavy duty aluminium lugs duly crimped with crimping tool, PVC tape, etc. as required for each length of the cable for bothend. a)3.5 core x 120sq mm, 1100 volts. • The job includes all types of material and labour charges and taxes thereof.
8Chemical Earthing of the body of the Panels of 250A Change Over panel , Auto cascading panel for Vacuum Pumps and frame of Vacuum Pumpseach by way ofexcavation of two pits of proper size upto a depth of 7 ft’ for providing and laying of two copper rods in hard and soft soil suitable for 07 ft’ long copper electrode followed by filling of required quantity of Earthing chemical and interconnecting to each components through GI Strip with nuts and bolts. Complete job with cost of material, labour charges and all kind of taxes thereof.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail