Power Development Department has published Tender For Stage Contract For Safeguarding Of District Adm. Complex Conference Hall Etc. Mini Sectt Reasi By Way Of Upgradation Maintenance Of Electronic Items And Gen Set Etc.. Submission Date for this Tender is 24-07-2023. Electronic Items Tenders in reasi Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 17-Jul-2023 | Extension of time | Date | 24-07-2023 |
Sl. No. | Item Description |
1 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Group-A) |
2 | Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable etc as required (Group-A) |
3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group-A) |
4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc.as required. |
5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required. |
6 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. |
7 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. |
8 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. |
9 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
10 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
11 | Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. |
12 | 2x1.5Sq.mm+ 1 x 1.5Sq.mm earth wire |
13 | 2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire |
14 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
15 | 2 x 6 sq. mm + 1 x 6 sqmm earth wire |
16 | 2 x 10 sq. mm + 1 x 6 sq. mm earth wire |
17 | 2 x 16 sq. mm + 1 x 6 sq. mm earth wire |
18 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
19 | 4 x 10 sq. mm + 2 x 6 sq. mm earth wire |
20 | 4 x 16 sq. mm + 2 x 6 sq. mm earth wire |
21 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
22 | Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. |
23 | 1 x 1.5 sq. mm |
24 | 2 x 1.5 sq. mm |
25 | 3 x 1.5 sq. mm |
26 | 1x 2.5 sq. mm |
27 | 2 x 2.5 sq. mm |
28 | 3 x 2.5 sq. mm |
29 | 1 x 4 sq. mm |
30 | 2 x 4 sq. mm |
31 | 3 x 4 sq. mm |
32 | 4 x 4 sq. mm |
33 | 5 x 4 sq. mm |
34 | 6 x 4 sq. mm |
35 | 1 x 6 sq. mm |
36 | 2 x 6 sq. mm |
37 | 3 x 6 sq. mm |
38 | 4 x 6 sq. mm |
39 | 5 x 6 sq. mm |
40 | 6 x 6 sq. mm |
41 | 1 x 10 Sq mm |
42 | 2 x 10 Sq mm |
43 | 3 x 10 Sq mm |
44 | 1 x 16 Sq mm |
45 | 2 x 16 Sq mm |
46 | 3 x 16 Sq mm |
47 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as |
48 | 1 Pair |
49 | 2 Pair |
50 | 4 Pair |
51 | Supplying and fixing of ceiling fan offollowingsweep with 2.25 mfd condenser and 1"-6" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. |
52 | 900 mm sweep |
53 | 1200 mm sweep |
54 | Supplying & fixing of Pedestal Fan 400 |
55 | Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type)on wall with necessary connection as required. |
56 | Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan. |
57 | 225 mm / 9" sweep exhaust fan |
58 | 300mm/12" sweep exhust fan |
59 | 380mm/15" Heavy duty |
60 | Supplying and fixing of fan hook (U hook) on celiling with 2 nos. of anchor fastener on both ends with necessary bolts andnuts and mansonry work as required. |
61 | Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. |
62 | 6 way (Double door) |
63 | 8 way(Double door ) |
64 | 12 way (Double door) |
65 | 16 way (Double door) |
66 | Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required. |
67 | 4 Way (4+12), (Double door ) |
68 | 6 way ( 4+18), (Double door) |
69 | 8 way (4+24), (Double door) |
70 | 12 way (4 +36), (Double door) |
71 | Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall bepre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded withBEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendlyGI Electrode Earthing should be maintinance free and does not requireregular manual addition of water . The earthing pit should be covered with PVC cover. |
72 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
73 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
74 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
75 | Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover. |
76 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
77 | Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. |
78 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
79 | Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make). |
80 | 20 mm |
81 | 25 mm |
82 | 32 mm |
83 | 40 mm |
84 | Supplying and fixing of Following light fitting on ceiling/ wall with necessary connection from as required. |
85 | Post Light 35 watts |
86 | 20/22 watt LED 4 feet tube light fitting/fixture |
87 | Decorative LED Hanging Light for officer table as apporved by site Engineer |
88 | LED Batten Tube fitting 600mm size 10/11 watt |
89 | 600 mm x 600 mm size recessed mounted LED Luminaries 34/36 watt. havingminimum 3600 Lumens with minimum lumens efficiency 110 Lumens/watt (Commercial type) |
90 | Mirror light LED fitting with 9/11W LED lamp |
91 | Providing and fixing of LED Lamp. |
92 | 5W |
93 | 9W |
94 | 12W |
95 | 15W |
96 | 18W |
97 | 20W |
98 | Providing and fixing of E-27 LED Light |
99 | 9 watt (warm) |
100 | 9 watt (White) |
101 | 12 watt (warm) |
102 | 12 watt (White) |
103 | Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. |
104 | 45 watt |
105 | 70 watt |
106 | 90 watt |
107 | Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating. |
108 | 9 watt. |
109 | 15 watt. |
110 | 18 watt. |
111 | Providing & fixing of following accessories. |
112 | 5/6 Amp. 3 pinTop |
113 | 5/6 Amp 2 pin Top |
114 | 15/16 Amp 3 pin top |
115 | Insulation Tape (ISI brand) |
116 | Electronic Step Type fan Regular (Piano type) |
117 | Celing Rose |
118 | 2.2/3/3.5 mfd fan condenser |
119 | Brass batten/ angle holder including (Modular) connection etc. as required. |
120 | Dimmer Type Regulator (with numbering) |
121 | 5/6 Amp combined |
122 | 15/16 Amp combined |
123 | Toolkit comprises of plier, screw driver and Phase tester |
124 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
125 | 1 or 2 Module (75mm x 75mm) |
126 | 3 Module (100mm x 75mm) |
127 | 4 Module (125mm x 75mm) |
128 | 6 Module (200mm x 75mm) |
129 | 8 Module (125mm x125mm) |
130 | 12 Module ( 200mm x 150mm) |
131 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
132 | 1 or 2 Module |
133 | 3 Module |
134 | 4 Module |
135 | 6 Module |
136 | 8 Module |
137 | 12 Module |
138 | Supplying and fixing following piano type switch/ socket on the existing box/ cover inculding connection etc. as required. |
139 | 5/6 amp switch |
140 | 15/16 amp switch |
141 | 3 pin 5/6 amp socket outlet |
142 | 6 pin 15/16 amp socket outlet |
143 | Telephone socket outlet |
144 | TV Antenna socket outlet |
145 | Bell push |
146 | 2 pin socket outlet 5 Amp. |
147 | Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required. |
148 | 5/6 amps switch |
149 | 2 way 5/6 amps switch |
150 | 15/16 amp switch |
151 | 3 pin 5/6 amp socket outlet |
152 | 6 pin 15/16 socket outlet |
153 | Telephone socket outlet |
154 | TV Antenna socket outlet |
155 | Bell push |
156 | 2 pin socket outlet 5 Amp. |
157 | Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge. |
158 | 900mm /1200mm / 1400mm sweep AC ceiling fan |
159 | 300mm sweep exchaust fan |
160 | Servicing of the Geyser etc. as required. |
161 | Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed) |
162 | Heating Element |
163 | Thermostat with control |
164 | Replacement of Assembly complete job |
165 | Repairing of Geyser by Replacing |
166 | Single pole upto 32 amp. |
167 | Single pole and neutral upto 32 amp. |
168 | Double pole upto 32 amp. |
169 | Double pole32 amp. (Modular) |
170 | Triple Pole and netural upto 32 amp. |
171 | SPN 40 Amp |
172 | SPN 63 Amp |
173 | TPN 40 Amp |
174 | TPN 63 Amp |
175 | Supplying, installation, testing and commissioning of Cubical type Indoor/OutdoorLT Panel Board Suitable for 415 V 3 Phase 4 wire 50 Hz AC supply system with provision for housing incomers, Out Going, COS, Bus Bars etc. as required but excluding the cost of MCCB"s, Bus Bars and Change over as per the following Description (IP:42) General Floor Distribution Panel. The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A drawing wiring diagrams, single line diagram before start of fabrication of LT panel Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating. Thepanel Builder shall be CPRI/ERDA/ANY NABL ACCREDITED LAB approved. |
176 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type) |
177 | 100 Amp, 30 KA, FP MCCB ICU = 100% ICS |
178 | 160 Amp, 36 KA, FP MCCB ICU = 100% ICS |
179 | 200 Amp, 36 KA, FP MCCB ICU = 100% ICS |
180 | 250 Amp, 36KA, FPMCCB ICU = 100% ICS |
181 | 400 Amp, 50 KA, FPMCCB ICU = 100% ICS |
182 | ON Load Change Over Switch FP 100 amp. (Front operated) |
183 | ON Load Change Over Switch FP 200 amp. (Front operated) |
184 | Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Bus Bar Indicating Lamp, CT Set etc. |
185 | Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG. |
186 | Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) |
187 | 16 sq. mm 4 core |
188 | 25 sq. mm 3.5 core |
189 | 35 sq. mm 3.5 core |
190 | 50 sq. mm 3.5 core |
191 | 70 sq. mm 3.5 core |
192 | 95 sq. mm 3.5 core |
193 | 120 sq. mm 3.5 core |
194 | 150 sq. mm 3.5 core |
195 | 185 sq. mm 3.5 core |
196 | 240 sq. mm 3.5 core |
197 | 300 sq. mm 3.5 core |
198 | 400 sq. mm 3.5 core |
199 | Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured. |
200 | 6 sq. mm |
201 | 10 sq. mm |
202 | 16 sq.mm |
203 | 25 sq.mm |
204 | 35 sq.mm |
205 | Labour charge for electrician |
206 | Labour charge for Helperelectrician |
207 | Supplying & Drawing of Co- axial TV cable RG-6 grade, 0.7 mm solid copper conductor. |
208 | Supplying & Drawing of UTP 4 point Cat-6 cable (1 run cable) (D-Link, Schneider, Systimax) |
209 | Supplying ofRemote Bells |
210 | Supplying & fixing of following PVC Gang Box. |
211 | One way |
212 | Two way |
213 | 1 + 1 way |
214 | 3 + 1 way |
215 | 4 + 1 way |
216 | 6 + 1 way |
217 | 1 + 1 way (Power) |
218 | Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten). |
219 | Casing Caping 1" |
220 | Casing Caping 3/4" |
221 | Deep Box |
222 | Fan Box |
223 | Conceeled Box |
224 | Junction Box (Metal) |
225 | Supplying and fixing ofPhenolic Laminated Sheet 9" x 11"including cutting the space for switches/socket etc. |
226 | Supplying and fixing of Phenolic Laminated Sheet 9" x 6" including cutting the space for switches/socket etc. |
227 | Supplying and fixing of Phenolic Laminated Sheet 4" x 4" including cutting the space for switches/socket etc. |
228 | Supplying and fixing of Phenolic Laminated Sheet 11" x 13" including cutting the space for switches/socket etc. |
229 | Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding) |
230 | 0.5 HP |
231 | 1 HP |
232 | Rewinding of 1 phase (0.5 HP) motor for water lifting (Copper winding) |
233 | Rewinding of 1 phase (1 HP) motor for water lifting (Copper winding) |
234 | Supply & installation of following type inverters |
235 | Invertor 1050 VA |
236 | Invertor2000 VA |
237 | Supplying & fixing of Battery 12 Volt. Tubular 150 AH with36 months Guarantee Note.:- (Rs.1800 /Battery has to be deduct for the scrap of old batteries from allotted rate in case of replacement of battery is out of warranty period. |
238 | Supplying & fixing of PVC Trolley for housing single battery inverter |
239 | Supplying & fixing of PVC Trolley for housing double battery inverter |
240 | Repair to PCB of inverter |
241 | 850 VAto 1050 VA |
242 | 1650 VA to 2000 VA |
243 | Replacement of PCB of inverter |
244 | 850 VAto 1050 VA |
245 | 1650 VA to 2000 VA |
246 | Full HD 2 MP 1080P D&N IP IR Dome/Bullet Camera (with SD Card Slot) |
247 | Full HD 5 MP 1080P D&N IP IR Dome/Bullet Camera (with SD Card Slot) |
248 | Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. |
249 | Supply, Installation, Testing and comissioning of 8 port Layer -2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. |
250 | Supply, Installation, Testing and comissioning of 24 port Layer -2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link |
251 | Supplying ,installation testing and commissioning of 32 Channel Network Video Recorder (NVR) minimum 4 sata. |
252 | Supplying ,installation testing and commissioning of 16 Channel Network Video Recorder (NVR) minimum 4 sata (as per specfication enclosed). Make:-Bosch, Pelco, Samsung, Sony, Honeywell, AXIS |
253 | 6 TB surveillance Hard disk storage device. |
254 | 4TB surveillance Hard disk storage device. |
255 | Micro SD/SDHC Card 128 GB |
256 | 1 mtr. Cat 6 Networking patch cord cable. |
257 | Supply offollowing electrical /networking components. |
258 | ADSL Modem Router Double Antenna |
259 | 8 Port Switch Networking Switch |
260 | 16 Port Switch Networking Switch |
261 | 24 Port Switch Networking Switch |
262 | 24 Port Patch Panel |
263 | Adaptor for charger |
264 | RJ 45 Jack complete |
265 | PVC I/O Box with RJ 45 jack outlet connection (Modular) |
266 | HDMI Cable 3 Mtrs. |
267 | HDMI Cable 10 Mtrs. |
268 | HDMI Cable 20 Mtrs. |
269 | Supply Installation Testing & Commissioning offollowing sizesEquipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling, power Distribution Paneland proper locking arrangements. |
270 | 4 U Rack |
271 | 6 U Rack |
272 | Supplying, installation, testing and commissioning of 1 KVA offlineUPS with minimum backup of 20 minutes and having over load, short circuit protection. |
273 | Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required. |
274 | 5/6 Ltr (instant) |
275 | 15 Ltr |
276 | 25 Ltr |
277 | 35 Ltr |
278 | 50 Ltr |
279 | Supply ofHalogen Electrical heaters (3 Rods) |
280 | Supply ofHeating Convector (Blower) |
281 | Supply ofPillar Heater |
282 | Supply ofRod for Pillar Heater Gopi |
283 | Supply of following electrical appliances. |
284 | Electric Fly Catcher |
285 | Electric Kettle above 1 Ltr. Upto 2 Ltr. Capacity. |
286 | Supplying of extension Card for bearing load upto 4 KW |
287 | Repairing & Servicing of D.G set by way of changing of the oil, filters and other repairs as requred to make the Gen set in good working condition |
288 | Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required. |
289 | (RO + UV + UF mineral control with TDS control ) |
290 | UV purifier for water cooler |
291 | Supplying, installation, testing and commissioning of1.5 Ton Inverter type SplitAC"s (copper) (3 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall whereever required.Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. |
292 | Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:-2 Years from the date of installation. |
293 | 4 KVA |
294 | Supplying & fixing of M.S Wall Stand duly powder coated for outdoor unit of Split AC |
295 | Supplying & fixing of drain pipe for indoor unit 1" |
296 | Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC |
297 | Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 2.0 Ton AC |
298 | Supply, erection, testing and commissioning of compressor suitable for 1.5/2 Ton split /window type A.C with Gas charging and other required accessories to get A.C workable. |
299 | Provision of Gas charging of 1.5/2.0 Ton split/ window type A.C including valve etc if required. |
300 | Installationof 1.5/2.0 Ton window A.C |
301 | Installation of 1.5/2.0 Ton split A.C |
302 | Servicing of Split AC of All Capacities |
303 | Servicing of Window AC of All Capacities |
304 | Replacement of defective motor of 1.5 /2.0 Ton Split /Window A.C Outdoor |
305 | Replacement of defective capacitor for 1.5 /2.0 Ton Split /Window |
306 | Providing & fixing of Blades of 1.5/2.0 Ton Split / Window A.C |
307 | Providing & fixing of Blower drum (Split AC) |
308 | 1.5 Ton Split A.C |
309 | 1.5 Ton Window A.C |
310 | Supply, erection, testing and commissioning compressor suitable for 150/150 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. |
311 | Supply, erection, testing and commissioning compressor suitable 40/80 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. |
312 | Provision of Gas charging of water cooler 150/150 ltr. |
313 | Provision of Gas charging of water cooler 40/80 ltr. |
314 | Dismantling of existing Split AC & reinstallation of Split AC with gas top up |
315 | Dismantling of existing Window AC & reinstallation of Window AC. |
316 | Dismantling of existing Split AC of All Capacities |
317 | Dismantling of existing Window AC of All Capacities |
318 | Repair ofPCB of Split/Window AC 1.5/2.0 Ton |
319 | Servicing of Water purifier by replacing candles. (R.O type) |
320 | Servicing of Water Purifierby replacing Candles of water cooler |
321 | Repairing of existing VRV / Duct AC system of Conference Hall by way of replacing compressors, ducting, capacitors, gas charging, detecting the causeof leakage of gas & repairing the same longwith other accessories for making the system workable (complete Job.) |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail