Tender For Stage Contract For Safeguarding Of District Adm. Complex Conference Hall Etc. Mini Sectt Reasi By Way Of Upgradation Maintenance Of Electronic Items And Gen Set Etc., reasi-Jammu And Kashmir

Power Development Department has published Tender For Stage Contract For Safeguarding Of District Adm. Complex Conference Hall Etc. Mini Sectt Reasi By Way Of Upgradation Maintenance Of Electronic Items And Gen Set Etc.. Submission Date for this Tender is 24-07-2023. Electronic Items Tenders in reasi Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

38520234
Corrigendum : Tender For Stage Contract For Safeguarding Of District Adm. Complex Conference Hall Etc. Mini Sectt Reasi By Way Of Upgradation Maintenance Of Electronic Items And Gen Set Etc.
Open Tender
Indian
Jammu And Kashmir
reasi
24-07-2023

Tender Details

Stage Contract For Safeguarding Of District Adm. Complex Conference Hall Etc. Mini Sectt Reasi By Way Of Upgradation Maintenance Of Electronic Items And Gen Set Etc.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Jul-2023 Extension of time Date 24-07-2023

Key Value

Document Fees
INR 600 /-
EMD
INR 26000.0 /-
Tender Value
INR 13 Lakhs /-

BOQ Items

Name of Work :Stage Contract for Safeguarding of District Adm. Complex/Conference Hall etc. Mini Sectt, Reasi by way of up-gradation/maintenance of electronic items and Gen set etc.
Sl. No. Item Description
1Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Group-A)
2Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable etc as required (Group-A)
3Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group-A)
4Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc.as required.
5Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required.
6Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
7Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
8Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
9Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
10Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
11Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
122x1.5Sq.mm+ 1 x 1.5Sq.mm earth wire
132 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire
142 x 4 sq. mm + 1 x 4 sq. mm earth wire
152 x 6 sq. mm + 1 x 6 sqmm earth wire
162 x 10 sq. mm + 1 x 6 sq. mm earth wire
172 x 16 sq. mm + 1 x 6 sq. mm earth wire
184 X 6 sq. mm + 2 X 6 sq. mm earth wire
194 x 10 sq. mm + 2 x 6 sq. mm earth wire
204 x 16 sq. mm + 2 x 6 sq. mm earth wire
21Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
22Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.
231 x 1.5 sq. mm
242 x 1.5 sq. mm
253 x 1.5 sq. mm
261x 2.5 sq. mm
272 x 2.5 sq. mm
283 x 2.5 sq. mm
291 x 4 sq. mm
302 x 4 sq. mm
313 x 4 sq. mm
324 x 4 sq. mm
335 x 4 sq. mm
346 x 4 sq. mm
351 x 6 sq. mm
362 x 6 sq. mm
373 x 6 sq. mm
384 x 6 sq. mm
395 x 6 sq. mm
406 x 6 sq. mm
411 x 10 Sq mm
422 x 10 Sq mm
433 x 10 Sq mm
441 x 16 Sq mm
452 x 16 Sq mm
463 x 16 Sq mm
47Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as
481 Pair
492 Pair
504 Pair
51Supplying and fixing of ceiling fan offollowingsweep with 2.25 mfd condenser and 1"-6" down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire.
52900 mm sweep
531200 mm sweep
54Supplying & fixing of Pedestal Fan 400
55Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type)on wall with necessary connection as required.
56Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan.
57225 mm / 9" sweep exhaust fan
58300mm/12" sweep exhust fan
59380mm/15" Heavy duty
60Supplying and fixing of fan hook (U hook) on celiling with 2 nos. of anchor fastener on both ends with necessary bolts andnuts and mansonry work as required.
61Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.
626 way (Double door)
638 way(Double door )
6412 way (Double door)
6516 way (Double door)
66Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required.
674 Way (4+12), (Double door )
686 way ( 4+18), (Double door)
698 way (4+24), (Double door)
7012 way (4 +36), (Double door)
71Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall bepre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded withBEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendlyGI Electrode Earthing should be maintinance free and does not requireregular manual addition of water . The earthing pit should be covered with PVC cover.
72Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
73Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
74Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
75Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
76Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
77Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
78Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
79Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make).
8020 mm
8125 mm
8232 mm
8340 mm
84Supplying and fixing of Following light fitting on ceiling/ wall with necessary connection from as required.
85Post Light 35 watts
8620/22 watt LED 4 feet tube light fitting/fixture
87Decorative LED Hanging Light for officer table as apporved by site Engineer
88LED Batten Tube fitting 600mm size 10/11 watt
89600 mm x 600 mm size recessed mounted LED Luminaries 34/36 watt. havingminimum 3600 Lumens with minimum lumens efficiency 110 Lumens/watt (Commercial type)
90Mirror light LED fitting with 9/11W LED lamp
91Providing and fixing of LED Lamp.
925W
939W
9412W
9515W
9618W
9720W
98Providing and fixing of E-27 LED Light
999 watt (warm)
1009 watt (White)
10112 watt (warm)
10212 watt (White)
103Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required.
10445 watt
10570 watt
10690 watt
107Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.
1089 watt.
10915 watt.
11018 watt.
111Providing & fixing of following accessories.
1125/6 Amp. 3 pinTop
1135/6 Amp 2 pin Top
11415/16 Amp 3 pin top
115Insulation Tape (ISI brand)
116Electronic Step Type fan Regular (Piano type)
117Celing Rose
1182.2/3/3.5 mfd fan condenser
119Brass batten/ angle holder including (Modular) connection etc. as required.
120Dimmer Type Regulator (with numbering)
1215/6 Amp combined
12215/16 Amp combined
123Toolkit comprises of plier, screw driver and Phase tester
124Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1251 or 2 Module (75mm x 75mm)
1263 Module (100mm x 75mm)
1274 Module (125mm x 75mm)
1286 Module (200mm x 75mm)
1298 Module (125mm x125mm)
13012 Module ( 200mm x 150mm)
131Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
1321 or 2 Module
1333 Module
1344 Module
1356 Module
1368 Module
13712 Module
138Supplying and fixing following piano type switch/ socket on the existing box/ cover inculding connection etc. as required.
1395/6 amp switch
14015/16 amp switch
1413 pin 5/6 amp socket outlet
1426 pin 15/16 amp socket outlet
143Telephone socket outlet
144TV Antenna socket outlet
145Bell push
1462 pin socket outlet 5 Amp.
147Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required.
1485/6 amps switch
1492 way 5/6 amps switch
15015/16 amp switch
1513 pin 5/6 amp socket outlet
1526 pin 15/16 socket outlet
153Telephone socket outlet
154TV Antenna socket outlet
155Bell push
1562 pin socket outlet 5 Amp.
157Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge.
158900mm /1200mm / 1400mm sweep AC ceiling fan
159300mm sweep exchaust fan
160Servicing of the Geyser etc. as required.
161Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed)
162Heating Element
163Thermostat with control
164Replacement of Assembly complete job
165Repairing of Geyser by Replacing
166Single pole upto 32 amp.
167Single pole and neutral upto 32 amp.
168Double pole upto 32 amp.
169Double pole32 amp. (Modular)
170Triple Pole and netural upto 32 amp.
171SPN 40 Amp
172SPN 63 Amp
173TPN 40 Amp
174TPN 63 Amp
175Supplying, installation, testing and commissioning of Cubical type Indoor/OutdoorLT Panel Board Suitable for 415 V 3 Phase 4 wire 50 Hz AC supply system with provision for housing incomers, Out Going, COS, Bus Bars etc. as required but excluding the cost of MCCB"s, Bus Bars and Change over as per the following Description (IP:42) General Floor Distribution Panel. The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A drawing wiring diagrams, single line diagram before start of fabrication of LT panel Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating. Thepanel Builder shall be CPRI/ERDA/ANY NABL ACCREDITED LAB approved.
176Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)
177100 Amp, 30 KA, FP MCCB ICU = 100% ICS
178160 Amp, 36 KA, FP MCCB ICU = 100% ICS
179200 Amp, 36 KA, FP MCCB ICU = 100% ICS
180250 Amp, 36KA, FPMCCB ICU = 100% ICS
181400 Amp, 50 KA, FPMCCB ICU = 100% ICS
182ON Load Change Over Switch FP 100 amp. (Front operated)
183ON Load Change Over Switch FP 200 amp. (Front operated)
184Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Bus Bar Indicating Lamp, CT Set etc.
185Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG.
186Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)
18716 sq. mm 4 core
18825 sq. mm 3.5 core
18935 sq. mm 3.5 core
19050 sq. mm 3.5 core
19170 sq. mm 3.5 core
19295 sq. mm 3.5 core
193120 sq. mm 3.5 core
194150 sq. mm 3.5 core
195185 sq. mm 3.5 core
196240 sq. mm 3.5 core
197300 sq. mm 3.5 core
198400 sq. mm 3.5 core
199Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured.
2006 sq. mm
20110 sq. mm
20216 sq.mm
20325 sq.mm
20435 sq.mm
205Labour charge for electrician
206Labour charge for Helperelectrician
207Supplying & Drawing of Co- axial TV cable RG-6 grade, 0.7 mm solid copper conductor.
208Supplying & Drawing of UTP 4 point Cat-6 cable (1 run cable) (D-Link, Schneider, Systimax)
209Supplying ofRemote Bells
210Supplying & fixing of following PVC Gang Box.
211One way
212Two way
2131 + 1 way
2143 + 1 way
2154 + 1 way
2166 + 1 way
2171 + 1 way (Power)
218Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten).
219Casing Caping 1"
220Casing Caping 3/4"
221Deep Box
222Fan Box
223Conceeled Box
224Junction Box (Metal)
225Supplying and fixing ofPhenolic Laminated Sheet 9" x 11"including cutting the space for switches/socket etc.
226Supplying and fixing of Phenolic Laminated Sheet 9" x 6" including cutting the space for switches/socket etc.
227Supplying and fixing of Phenolic Laminated Sheet 4" x 4" including cutting the space for switches/socket etc.
228Supplying and fixing of Phenolic Laminated Sheet 11" x 13" including cutting the space for switches/socket etc.
229Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)
2300.5 HP
2311 HP
232Rewinding of 1 phase (0.5 HP) motor for water lifting (Copper winding)
233Rewinding of 1 phase (1 HP) motor for water lifting (Copper winding)
234Supply & installation of following type inverters
235Invertor 1050 VA
236Invertor2000 VA
237Supplying & fixing of Battery 12 Volt. Tubular 150 AH with36 months Guarantee Note.:- (Rs.1800 /Battery has to be deduct for the scrap of old batteries from allotted rate in case of replacement of battery is out of warranty period.
238Supplying & fixing of PVC Trolley for housing single battery inverter
239Supplying & fixing of PVC Trolley for housing double battery inverter
240Repair to PCB of inverter
241850 VAto 1050 VA
2421650 VA to 2000 VA
243Replacement of PCB of inverter
244850 VAto 1050 VA
2451650 VA to 2000 VA
246Full HD 2 MP 1080P D&N IP IR Dome/Bullet Camera (with SD Card Slot)
247Full HD 5 MP 1080P D&N IP IR Dome/Bullet Camera (with SD Card Slot)
248Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm.
249Supply, Installation, Testing and comissioning of 8 port Layer -2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt.
250Supply, Installation, Testing and comissioning of 24 port Layer -2 unmanagable Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000base Tx PoE port with 2 SFP port, 1 no. dual personality Gbe Port for copper/fiber uplink, 20 Gbps switching capacity, 14.88 MPPS Forwarding performance , maximum power consumption 64 watt. Make: Cisco/D-link
251Supplying ,installation testing and commissioning of 32 Channel Network Video Recorder (NVR) minimum 4 sata.
252Supplying ,installation testing and commissioning of 16 Channel Network Video Recorder (NVR) minimum 4 sata (as per specfication enclosed). Make:-Bosch, Pelco, Samsung, Sony, Honeywell, AXIS
2536 TB surveillance Hard disk storage device.
2544TB surveillance Hard disk storage device.
255Micro SD/SDHC Card 128 GB
2561 mtr. Cat 6 Networking patch cord cable.
257Supply offollowing electrical /networking components.
258ADSL Modem Router Double Antenna
2598 Port Switch Networking Switch
26016 Port Switch Networking Switch
26124 Port Switch Networking Switch
26224 Port Patch Panel
263Adaptor for charger
264RJ 45 Jack complete
265PVC I/O Box with RJ 45 jack outlet connection (Modular)
266HDMI Cable 3 Mtrs.
267HDMI Cable 10 Mtrs.
268HDMI Cable 20 Mtrs.
269Supply Installation Testing & Commissioning offollowing sizesEquipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling, power Distribution Paneland proper locking arrangements.
2704 U Rack
2716 U Rack
272Supplying, installation, testing and commissioning of 1 KVA offlineUPS with minimum backup of 20 minutes and having over load, short circuit protection.
273Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required.
2745/6 Ltr (instant)
27515 Ltr
27625 Ltr
27735 Ltr
27850 Ltr
279Supply ofHalogen Electrical heaters (3 Rods)
280Supply ofHeating Convector (Blower)
281Supply ofPillar Heater
282Supply ofRod for Pillar Heater Gopi
283Supply of following electrical appliances.
284Electric Fly Catcher
285Electric Kettle above 1 Ltr. Upto 2 Ltr. Capacity.
286Supplying of extension Card for bearing load upto 4 KW
287Repairing & Servicing of D.G set by way of changing of the oil, filters and other repairs as requred to make the Gen set in good working condition
288Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required.
289(RO + UV + UF mineral control with TDS control )
290UV purifier for water cooler
291Supplying, installation, testing and commissioning of1.5 Ton Inverter type SplitAC"s (copper) (3 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall whereever required.Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation.
292Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:-2 Years from the date of installation.
2934 KVA
294Supplying & fixing of M.S Wall Stand duly powder coated for outdoor unit of Split AC
295Supplying & fixing of drain pipe for indoor unit 1"
296Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC
297Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 2.0 Ton AC
298Supply, erection, testing and commissioning of compressor suitable for 1.5/2 Ton split /window type A.C with Gas charging and other required accessories to get A.C workable.
299Provision of Gas charging of 1.5/2.0 Ton split/ window type A.C including valve etc if required.
300Installationof 1.5/2.0 Ton window A.C
301Installation of 1.5/2.0 Ton split A.C
302Servicing of Split AC of All Capacities
303Servicing of Window AC of All Capacities
304Replacement of defective motor of 1.5 /2.0 Ton Split /Window A.C Outdoor
305Replacement of defective capacitor for 1.5 /2.0 Ton Split /Window
306Providing & fixing of Blades of 1.5/2.0 Ton Split / Window A.C
307Providing & fixing of Blower drum (Split AC)
3081.5 Ton Split A.C
3091.5 Ton Window A.C
310Supply, erection, testing and commissioning compressor suitable for 150/150 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable.
311Supply, erection, testing and commissioning compressor suitable 40/80 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable.
312Provision of Gas charging of water cooler 150/150 ltr.
313Provision of Gas charging of water cooler 40/80 ltr.
314Dismantling of existing Split AC & reinstallation of Split AC with gas top up
315Dismantling of existing Window AC & reinstallation of Window AC.
316Dismantling of existing Split AC of All Capacities
317Dismantling of existing Window AC of All Capacities
318Repair ofPCB of Split/Window AC 1.5/2.0 Ton
319Servicing of Water purifier by replacing candles. (R.O type)
320Servicing of Water Purifierby replacing Candles of water cooler
321Repairing of existing VRV / Duct AC system of Conference Hall by way of replacing compressors, ducting, capacitors, gas charging, detecting the causeof leakage of gas & repairing the same longwith other accessories for making the system workable (complete Job.)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail