Tender For Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Jal Shakti Sub Division Dharampur In Tehsil Dharampur Distt Mandi Hp Under Jjm, dharampur-Himachal Pradesh

Irrigation And Public Health Department has published Tender For Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Jal Shakti Sub Division Dharampur In Tehsil Dharampur Distt Mandi Hp Under Jjm. Submission Date for this Tender is 17-07-2023. Water Treatment Plant Tenders in dharampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38510936
Corrigendum : Tender For Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Jal Shakti Sub Division Dharampur In Tehsil Dharampur Distt Mandi Hp Under Jjm
Open Tender
Indian
Himachal Pradesh
dharampur
17-07-2023

Tender Details

Source Strengthening And Rehabilitation Of Various Water Supply Schemes Under Jal Shakti Sub Division Dharampur In Tehsil Dharampur Distt Mandi Hp Under Jjm Source Strengthening Protection Of Percolation Well Tanks Co Storage Tanks Co Wtp Of 0.95 Mld Capacity Repair Of Pump Houses Co Thrust Blocks 167 Nos Prov Laying Jointing And Testing Of Rising Main 125 Mm Dia Gms Pipe And Se Of Pumping Machinary

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Jul-2023 corrigendum Date 17-07-2023

Key Value

Document Fees
INR 2500 /-
EMD
INR 427576.0 /-
Tender Value
INR 3.95 Crore /-

BOQ Items

Name of Work: Source strengthening and Rehabilitation of Various Water Supply Schemes under JS Sub-Division Dharampur, Tehsil Dharampur, Distt. Mandi (HP). (Under JJM) (SH:- Source strenghtening & protection of percolation well/tanks, C/O storage tanks, C/O WTP of 0.95 MLD capacity, repair of pump houses, C/O thrust block 167 Nos, providing, laying, jointing and testing of Rising Main 125mm dia GMS pipe andSupplying & errection of pumping mechinery).
Sl. No. Item Description
1Cutting in earth work and disposal of excavated earth upto all leads and lifts complete in all respect as per direction and to the entire satisfaction of Engineer-in-Charge.
2Excavation in earth work and disposal of excavated earth upto a lead 20 mtrs and lift upto 1.50 mtrs, disposal earth to be levelled and neatly dressed in pick/jumper work complete within all lead and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
3Excavation in foundation, trenches etc. in all kinds of soil such as pick work, jumper work, blasting work in soft / hard rock, chiselling in soft / hard including wedging out of a rock where blasting is prohibited and stacking the excavated earth up to all lifts, stacking the excavated soil up to all lead clear from the edge of excavation and then returniing the stacked soil in 15 centimeters layers when required in to plinths, sides of foundation etc. consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed within all leads & lifts as perentire satisfaction of Engineer- in- charge.
4Providing and laying cement concrete 1:6:12 (1cement:6sand:12 graded crushed stone aggregate 40mm nominal size) and curing complete excluding cost of form work in foundation and plinth complete in all respect including carriage of materials in all leads and lifts as per direction and to the entire satiafaction of the Engineer-in- charge in all lead and lifts.
5Providing and laying cement concrete 1:5:10 (1 cement :5 sand : 10 graded stone aggregate 40mm nominal size)curing complete excluding cost of form work in retaining wall/breast wall as per direction and to the entire satisfaction of Engineer-in-Charge.
6Providing and laying cement concrete 1:3:6 (1 cement: 3 sand: 6 graded crushed stone agg. 40mm nominal size) and curing complete excluding cost of form work in:- Foundation and plinth upto all leads and lifts as per direction and to the entire satisfaction of Engineer-in-charge.
7Providing and laying cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size)and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
8Foundation footing bases of columns etc and mass concrete within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
9Suspended floors, roofs, landing and shelves and their support, balconies, beams, girders, bressumers and cantilever upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
10Providing & Laying cement concrete work Grade M30 (Design Mix) but not leaner than 1 : 1.5 : 3 (1 cement : 1.5 sand : 3 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in:-
11Foundation footing bases of columns etc and mass concrete within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
12Walls any thicknessbut not less than 0.1m thickness including attached pillaster buttresses, plinth and string courses from top of foundation upto two level all floor level as per direction and to the entire satisfaction of Engineer-in-Charge.
13Lintels,beams, girders, bressumers and cantilevers upto floor two level within all lead and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
14Archesupto floor two level in all leads and lifts as per direction and to the entiresatisfaction of Engineer-in-charge.
15Providing form work with steel plates 3.15 mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including centring, shuttering , strutting and propping etc. with wooden battens and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same for insitu- reinforcement concrete and plain concrete work in:-
16Flat surfaces such as soffits of suspended floors, roofs, landings and the like, Floors etc. up to any thicknesscomplete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
17Vertical surfacessuch as wall (any thickness) partitions and the like including attached pillasters, buttresses plinth and string courses and the likecomplete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
18Beam, cantilever, girders and lintels, Sides and soffits of beam, beam haunching, cantilever, bressumers and lintels not exceeding 1 mtr. In depth in all heights from floor complete within all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
19Edges of slabs and breaks in floors and walls under 20cm wide in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
20Providing form work of ordinary timber plankings so as to give a rough finish including centring, shuttering, strutting & propping etc. height of propping & centring below supporting floor to ceilling not exceeding 4 mts. And removal of the same for insitu-reinforced concrete and plain concrete work in :
21Arches exceeding 6.00 mtrs span as per direction and to the entire satisfaction of Engineer-in-charge.
22Providing Tor steel reinforcement for RCC work including bending binding and placing in position complete upto all floor level within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
23Providing RCC work smooth finishing of the exposed surface with cement mortar 1:3 (1 cement :3 sand) and curing complete in all lead and lifts as per direction and to the entire satisfaction of the Engineer-in-Charge.
24Stone soling/boulder filling dry hand packed in under floor within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
25Stone/boulder filling below cement concrete courtyard within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
26Brick work using common burunt clay building bricks in super structure above plinth level up to floor two level in cement mortor 1:4 (1 cement : 4 sand) (2nd class brick) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
27Providing wood work in frames of door, window, clerestory window and other frames wrought, framed & fixed in position as per direction and to the entire satisfaction of Engineer-in-charge upto all lead and lifts. (2nd class deodar wood)
28Providing and fixing pressed steel doors and windows frame manufactured from commercial mild steel sheet of 1.25mm thickness including hinges jamb, lock jamb, beed and if required angle threshold of mild steel angle of section 50x25mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split and tails to each jamb including steel butt hinges 2.5mm thick with guards, lock strike plate and shock absorber as specified and applying a coat of approved steel primer after pretreatment of the surface as desired by Engineer-in-charge.
29Providing and Fixing panneled glazed or panelled and glazed shutters for doors, windows and clerestory windows,including black enamelled iron butt hinges with necessary screws. 40 mm thick. (2nd class deodar wood) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
3015mm thick cement plaster in single coat on rough side of brick/concrete/stone walls for interior plastering upto floor two level includong arises, internal round angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth (Cement mortar 1:4)
316 mm thick cement plaster to ceiling In cement mortar 1:4 (1 cement: 4 sand)
32Cement concrete flooring 1:2:4 (1 cement :2 sand :4 graded stone aggregate 20mm nominal size) laid in one layer finished with a floating coat of neat cement (40 mmthick) as per direction and to the entire satisfaciton ofEngineer-in-charge upto all lead and lift.
33Kota stone slab flooring 20 mm (average) thick base of cement mortor 1:4 (1 cement :4 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. including rubbing and polishing complete 40 mm Thick as per direction and to the entire satisfaction of Engineer-in-Charge.
34Providing and fixing 10mm thick anti skidwaterproofstainandimpect resistent heavy duty vetrified tiles Nitco or equivalant 300x300mmx10mmmanufacturedof approvedshadeandcolourin flooring, treads of steps and landings laid over 12mm thick cement mortar 1:3(1cement :3 sand)jointed with cement slurry mixed with pigment to match the shade oftilesas required complete within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
35Providing and fixing anodized brass sliding door bolt with bolts, nuts andscrews etc. complete as per the direction and to the entire satisfaction of Engineer-in-charge.
36250x 10 mm
37Providing and fixing anodized brass tower bolt (barrel type) with bolts, nuts andscrews etc. complete as per the direction and to the entire satisfaction of Engineer-in-charge.
38200 x10 mm
39Providing and fixing anodized brass handles with necessary screws etc. Complete as per the direction and to the entire satisfaction of Engineer-in-charge.
40125 mm
41Providing 40x3 mm iron hold fast 40 cm long including Fixing to frame with 10 cm da bolts nuts and wooden pluges and embencing in C.C. block 30x10x15 cm 1:3:6 ( 1 cement:3 sand: 6 gradedstoneaggregate 20 mmnominal size) within all leads and lifts as per direction and to the entire satisfaction of the Engineer in Charge.
42Steel work welded in builtup section, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead painting in trusses and trussed purlins in building as per direction of Engineer-in-Charge upto all lead and lift.
43Steel work welded in built up section, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paintin grating, framed guard bars ladders, railing brackets and similar works as per direction of Engineer-in-Charge upto all lead and lift.
44Providing and fixing 0.60mm thick prepainted steel sheet in roofing with hot dipped metallic zinc coated sheet with top coat of regular modified polyster (RNP) organic coating of 20 microns over 5 microns primer coating to back coat of polyster of 5 microns over 5 microns primer coating i/c fixing with prepainted iron J or L hooks, bolts and nuts 6mm dia metre with prepainted limpet and rubber washers complete with all accesoriees including carriage of material in all leadsand lifts as required as per the direction of Engineer-in-charge
45Random rubble masonry/Polygonal rubble masornry ( uncoursed/ brought to courses) with hard stone of approved quality in foundation and plinth I/c levelling up with cement conrete 1:6:12 (1cement:6 sand :12 graded stone aggregate 20 mm nominal size ) at plinth level in cement motar 1:6 ( 1cement:6 sand)includingcuring complete. As per direction and to the antire satiafaction of the Engineer-in- charge in all lead and lifts.
46White washing with lime on undecorated wall surface two coats to give an even shade I/c throughly brooming the surface to remove all dirt, dust, mortar, dust and other foreign matter as per direction and to the entire satisfaction of Engineer-in-charge.
47Applying priming coat over new wood and wood based surfaces after and inciuding preparing the suface be thoroughly cleaning oil grease dirt and othr foreign sand papering and knotting Readymixed paint brushing wood primer pink complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge.
48Painting two coats (excluding priming coat) on new wood and wood based surfaces with enamel paintto give an even shade including cleaningthe surface of dirt, dust and other foreign matters sand papering and stopping with readymade paint other than white complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge.
49Providing and fixing of 3.15mm MS Sheet Manhole cover 600X600mm fixed on all sides with ISA 40x25x5mm top angle iron frame hinged on ISA 35x35x5mm bottom angle iron frame as per drawing. Pieces of MS Flat 20x4mm, 0.15m long be fixed on all sides as hold fast. The operation of manufacturing shall including cutting of MS Sheet, Angle Section & welding of MS Sheets, Angle Section, Hinges, Handles 150mm long, 20x4mm flats, locking arrangement and applying a priming coat of steel primer after pretreatment of surface to the entire satisfaction of the Engineer-in-Charge.
50Providing and laying heavy duty precast cement concrete inter locking paver blocks 80mm thick with chamferred edge vibro completed up to M-50 grade of NTC or equivalent make i/c border or kurb block gray or coloured over sub-base of concrete with 25 mm thick average thickness of cement mortar 1:4 (1 cement, 4 Sand) laid over and jointed with neat cement slurry mixed with pigment to match the shade of blocks i/c curing rubbing & polishing complete in all leads and lift as per direction and to the entire satisfaction of Engineer-in-Charge.
51Laying, jointing & testing of G.I pipe of following dia (medium class)for outlets pipe &scour pipes etc. in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge. (Labour rate)
52125 mm dia
53Providing and fixing double flangedCast Ironsluice valveof following dia of Kirloskar/Leader or any other approved make conforming to IS:14846/2000with up to date amendment as per Class PN-1 to withstand in normalseat pressure including welding with M.S. flanges table as per IS 6392-1971 including carriage in all leads and lifts as per direction and to the entiresatisfaction of Engineer-in-Charge.
54125mm dia with FT-5
55Providing and fixing vitreous china wash down water closet (European type W.C. Pan) with integral "P" or "S" trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement : 1 sand) (seat and cover to be measured and paid for separately)
56Providing and fixing 100 mm size P or S trap for water closet ( squatting pan)including jointing the trap with the pan and soil pipe in cement mortar 1:1 ( 1 cement :1 sand) Vitreous china
57Providing and fixing 10.0/12.50/25.00 litres vitreous china low level flushing cistern with a pair of C.I. or mild steel brackets, complete with fittings such as lead valve less syphon 15mm nominal size brass valve with polythene float, C.P. brass handle unions and couplings for connections with inlet, outlet and overflow pipes 40mm dia C.P. flush bend including cutting holes in walls and making good the same and connecting the flush bend with cistern and closet (overflow pipe to be measured and paid for separately)
58Providing and fixing vitrous china wash basin with single hole for pillar tap with C.I. or M.S. brackets painted white including cutting holes and making good the same but excluding fittings550mm X 400 mm
59Providing and fixing PVC Pipe 100 mm dia complete.
60Providing and Fixing to wall, ceilling and floor galvanised mild steel tube, fitting and clamps includingmaking good the same ic.c. wall, ceiling and flooring 15mm
61Providing and Fixing PVC water storage tank complete in all respect.1000 ltrs capacity
62Construction and commissioning of water treatment plant 0.95 MLD Capacity in shape of Rapid sand filter bed and allied unit :- The scope of work includes the construction of 0.95 MLD Capacity water treatment plant capable to treat the raw water of the quality specified in the basic design data to produce clear water as per the requirement of CPHEEO manual on water supply and treatment and as specified in base design data. The water treatment plant shall include the construction of inlet chamber, raw water tank, presetting tank, Parshall flume, Flash mixer, alum solutiontanks and dosing arrangement flocculator settling tanks, rapid sand filter complete with back wash arrangement, clear water tank, complete disinfection arrangement with bleaching power, Elector Mechanical equipment piping values mechanical /electrical equipment electric wiring & panel board, sanitation, floodlights interconnection paths, site development up to a minimum of 3m from edge of battery limit of plant i/c retaining and breast walls and fencing. The firm shall submit the detailed hydraulic and structural design and drawings (6 copies) for each component of treatment plant which shall be approved by the department before the work is started. The design/drawing and bearing capacity of soili/c detailed survey and investigation of the mechanical /electrical equipment & wiring etc. along with manufactures specification /design also be submitted for approval by the department on the completion of all civil, mechanical and electrical works the contractor shall test run the plant for three months (90 days) before handing over the same to the department at the cost of the contractor. However, electrical charges shall be borne by the department .During this periods the contractor shall run the plant at full rated capacity and produce the results specified in the NIT as per the CPHEEO standers in the presence of Engineer –in –Charge. (Data sheet No -1)
63Rising main:- Laying, jointing and testing in trenches (to level or grade) of following dia Medium Class GMS pipes plain ended jointed with 5% flanged & remaining butt weld joints with of below diametreconforming to IS 1239-1990 (Part - I ) with latest upto date amendments of grade and wall thickness as specified below, suitable to withstand required hydraulic test pressure in randum length 4m-6m with plain ends and jointed with butt welding with electrodes as per IS 814-1991. The welding of joint to be done to make the joints leak proof (Earth work, flanged joints & butt welding joints to be mearsured and paid separately) and toentire satisfaction of the Engineer-in-Charge.The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect. (L.R.)
64125mm dia Medium Class
65Providing and welding M.S. flanges at suitable point, conforming to following tables as per IS 6392-1971 (Latest with up to date amendments)with plain end GMS pipe in three layers on both faces to make the joint leak proof (The cost oflaying of GMS pipes to be measured and paid for separtely). The welding of flanges should conform to IS 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS 1364, the thicthness of gasket not less than 3.00 mm conforming to IS 2712-1998. The work shall be done as per entire satisfactio of engineer in charge with in all leads and lifts.
66M.S. Flange joint 125 mm dia Table-17
67Providing circumferencial Butt welded joints by electrical arc welding to following diaGMS Pipes welded in requisite number of weld runs including thread cutting so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerlikon (Adore)- CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
68125 mm dia.
69Providing and fixing double flangedCast Ironsluice valveof following dia of Kirloskar/Leader or any other approved make conforming to IS:14846/2000with up to date amendment as per Class PN-1 to withstand in normalseat pressure including welding with M.S. flanges table as per IS 6392-1971 including carriage in all leads and lifts as per direction and to the entiresatisfaction of Engineer-in-Charge.
70125mm dia with FT-5
71Providing and fixing double flangedCast Ironreflux valveof following dia of Kirloskar/Leader or any other approved make conforming to IS:5312with up to date amendment as per Class PN-1.6 capable of with standing in normalseat pressure of 16.32 Kg/cm² including welding with M.S. flanges as per IS 6392-1971 including carriage in all leads and lift as per direction and to the entiresatisfaction of Engineer-in-Charge.
72125 mm dia with FT-5
73Pumping Machinery Submersible ( LWSS Proh ka Galloo Ist stage ):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskarmake conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
74SITE CONDITIONS:- Total Head 20.00mtrs Discharge required 14.50LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:-The site is located at a distance of 8 Km from head Qtr. Dharampur The Altitude of :- The Altitude of place is 636 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other Length of R/main 150 mtrs Dia of Rising main 150 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
75Supply of Air brake type Star Delta Starter of reputed make i.e L&T /Crompton /MEI conforming to BIS 8544 -( Part - II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 10 HP motor.
76Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
77Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
78Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
79ICTP switches 32 Amp. with HRC fuses of Havells/L&T/standard /cromption make for required motor of 10 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
80Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS: 8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating.
81MCB/MCCB of 32 Amp suitable for motor of 10 HP capacity of Havells/standard/MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
823 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
8350 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
84Supply of Kirloskar/ leader make cast iron (class PN 1.00 ) double flanged sluice valve of 125 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
85Supply of Kirloskar/leader make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 125 mm dia. and capable of with standing nominal seat pressure of of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
86Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 4.0 sqmm or of Suitable sizes.
87Supply of Leader /Kirloskar make 150 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 150 mm dia. of rising i.e. 150 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
88Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
89Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
90Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
91Providing and laying delivery pipe 150 mm dia. and common header 200 mm dia MSERW pipe jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
92Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
93Supply of suitable cable for water level guard
94Supply of supporting clamps.
95Supply of cable clips of required size.
96Erection of all equipment from Sr. No. 54 to 67 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
97Pumping Machinery Submersible (LWSS Proh ka Galloo 2nd Stage):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
98SITE CONDITIONS:- Total Head 15.00mtrs Discharge required 8.50LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation The site is located at a distance ofKm fromof machinery The Altitude of :- The Altitude of place is 726 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 35 mtrs Dia of Rising main 150 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
99Supply of Direct on line (D.O.L.) Starter of reputed make i.e L&T/Siemen conforming to BIS 8544 -( Part - I) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 5.0 HP motor.
100Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
101Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
102Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
103ICTP switches 32 Amp. with HRC fuses of Havells/L&T/standard /cromption make for required motor of 5.0 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
104Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
105MCB/MCCB of 32 Amp suitable for motor of 5.0 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
1063 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
10750 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
108Supply of Kirloskar/ leader make cast iron (class PN 1.00 ) double flanged sluice valve of 125 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
109Supply of Kirloskar/leader make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 125 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
110Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 2.5 sqmm or of Suitable sizes.
111Supply of Leader /Kirloskar make 150 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 150 mm dia. of rising i.e. 150 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
112Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
113Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
114Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
115Providing and laying delivery pipe 150 mm dia. and common header 200 mm dia MSERW pipe jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
116Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
117Supply of suitable cable for water level guard
118Supply of supporting clamps.
119Supply of cable clips of required size.
120Erection of all equipment from Sr. No. 71 to 84 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
121Pumping Machinery Submersible (LWSS Khanoud ):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
122SITE CONDITIONS:- Total Head 25.00mtrs Discharge required 9.00LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 697 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 60 mtrs Dia of Rising main 65 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
123Supply of Air brake type Star Delta Starter of reputed make i.e L&T /Crompton /MEI conforming to BIS 8544 -( Part - II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 10 HP motor.
124Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
125Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
126Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
127ICTP switches 32 Amp. with HRC fuses of Havells/L&T/standard /cromption make for required motor of 10 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
128Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
129MCB/MCCB of 32 Amp suitable for motor of 10 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
1303 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
13150 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
132Supply of Kirloskar/ leader make cast iron (class PN 1.00 ) double flanged sluice valve of 50 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
133Supply of Kirloskar/leader make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 50 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
134Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 4.0 sqmm or of Suitable sizes.
135Supply of Leader /Kirloskar make 65 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 65 mm dia. of rising i.e. 65 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
136Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
137Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
138Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
139Providing and laying delivery pipe 65 mm dia. and common header 80 mm dia GMS pipe Medium classas perIS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
140Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L7T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
141Supply of suitable cable for water level guard
142Supply of supporting clamps.
143Supply of cable clips of required size.
144Erection of all equipment from Sr. No. 88 to 101 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
145Pumping Machinery Submersible (LWSS Seoh - Seoh Dhar Gehra):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
146SITE CONDITIONS:- Total Head 22.00mtrs Discharge required 15.50LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 608 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 30 mtrs Dia of Rising main 125 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
147Supply of Air brake type Star Delta Starter of reputed make i.e L&T /Crompton /MEI conforming to BIS 8544 -( Part - II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 15 HP motor.
148Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
149Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
150Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
151ICTP switches 63 Amp. with HRC fuses of Havells/L&T/standard /cromption make for required motor of 15 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
152Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
153MCB/MCCB of 63 Amp suitable for motor of 15 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
1543 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
15550 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
156Supply of Kirloskar/ leader make cast iron (class PN 1.00 ) double flanged sluice valve of 100 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
157Supply of Kirloskar/leader make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
158Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 4.0 sqmm or of Suitable sizes.
159Supply of Leader /Kirloskar make 125 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 125 mm dia. of rising i.e. 125 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
160Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
161Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
162Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
163Providing and laying delivery pipe 125 mm dia. and common header 150 mm dia GMS pipe Medium classas perIS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
164Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
165Supply of suitable cable for water level guard
166Supply of supporting clamps.
167Supply of cable clips of required size.
168Erection of all equipment from Sr. No. 105 to 118 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
169Pumping Machinery Submersible ( LWSS Kamlah Fort):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
170SITE CONDITIONS:- Total Head 60.00mtrs Discharge required 5.50LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 1020 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 120 mtrs Dia of Rising main 50 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
171Supply of Direct on line (D.O.L.) Starter of reputed make i.e L&T /Crompton /MEI conforming to BIS 8544 -( Part - II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 7.50 HP motor.
172Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
173Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
174Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
175ICTP switches 32 Amp. with HRC fuses of Havells/L&T/standard /cromption make for required motor of 7.50 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
176Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
177MCB/MCCB of 32 Amp suitable for motor of 7.50 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
1783 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
17950 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
180Supply of Kirloskar/ leader make cast iron (class PN 1.00 ) double flanged sluice valve of 40 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
181Supply of Kirloskar/leader make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 40 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
182Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 2.5 sqmm or of Suitable sizes.
183Supply of Leader /Kirloskar make 50 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 50 mm dia. of rising i.e. 50 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
184Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
185Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
186Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
187Providing and laying delivery pipe 50 mm dia. and common header 65 mm dia GMS pipe Medium classas perIS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
188Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
189Supply of suitable cable for water level guard
190Supply of supporting clamps.
191Supply of cable clips of required size.
192Erection of all equipment from Sr. No. 122 to 135 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
193Pumping Machinery Submersible (LWSS Kandapattan Dhawali):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
194SITE CONDITIONS:- Total Head 40.00mtrs Discharge required 16.20LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:-The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 644 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 95 mtrs Dia of Rising main 125 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
195Supply of Oil immersed Star Delta Starter of reputed make i.e MEI/Kilburn conforming to BIS 8544 -( Part -II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 17.50 HP motor.
196Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
197Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
198Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
199ICTP switches 63 Amp. with HRC fuses of Havells/L&T/standard /cromption make for required motor of 17.50 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
200Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
201MCB/MCCB of 63 Amp suitable for motor of 17.50 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
2023 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
20350 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
204Supply of Kirloskar/ leader make cast iron (class PN 1.00 ) double flanged sluice valve of 100 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
205Supply of Kirloskar/leader make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm2 as per IS: 5312 (Part-I) 2004
206Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 6.0 sqmm or of Suitable sizes.
207Supply of Leader /Kirloskar make 125 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 125 mm dia. of rising i.e. 125 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
208Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
209Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
210Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
211Providing and laying delivery pipe 125 mm dia. and common header 150 mm dia GMS pipe Medium classas perIS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
212Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
213Supply of suitable cable for water level guard
214Supply of supporting clamps.
215Supply of cable clips of required size.
216Erection of all equipment from Sr. No. 139 to 152 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
217Pumping Machinery Submersible (LWSS Sari Sanour Kapahi):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
218SITE CONDITIONS:- Total Head 25.00mtrs Discharge required 7.00LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 749 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 20 mtrs Dia of Rising main 65 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
219Supply of Direct on line (D.O.L.) Starter of reputed make i.e L&T/Siemen conforming to BIS 8544 -( Part - I) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 5.0 HP motor.
220Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
221Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
222Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
223ICTP switches 32 Amp. with HRC fuses of Havells/L&T/standard /cromption make for required motor of 5.0 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
224Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
225MCB/MCCB of 32 Amp suitable for motor of 5.0 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
2263 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
22750 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
228Supply of Kirloskar/ leader make cast iron (class PN 1.00 ) double flanged sluice valve of 50 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
229Supply of Kirloskar/leader make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 50 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
230Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 2.5 sqmm or of Suitable sizes.
231Supply of Leader /Kirloskar make 65 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 65 mm dia. of rising i.e. 65 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
232Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
233Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
234Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
235Providing and laying delivery pipe 65 mm dia. and common header 80 mm dia MSERW pipe jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
236Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
237Supply of suitable cable for water level guard
238Supply of supporting clamps.
239Supply of cable clips of required size.
240Erection of all equipment from Sr. No. 156 to 169 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
241Pumping Machinery Submersible (LWSS Kot Dhawali ):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskar make conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
242SITE CONDITIONS:- Total Head 56.24mtrs Discharge required 19.37LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery:- The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 644 mtrs above MSL Type of Current:-AC three phase supply with RateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 950 mtrs Dia of Rising main 150 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
243Supply of Oil immersed Star Delta Starter of reputed make i.e MEI/Kilburn conforming to BIS 8544 -( Part -II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 25 HP motor.
244Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
245Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
246Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
247ICTP switches 63 Amp. with HRC fuses of Havells/L&T/standard /cromption make for required motor of 25 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
248Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
249MCB/MCCB of 63 Amp suitable for motor of 17.50 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
2503 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
25150 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
252Supply of Kirloskar/ leader make cast iron (class PN 1.00 ) double flanged sluice valve of 125 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
253Supply of Kirloskar/leader make cast iron (class PN-1.00) double flanged (swing check type) reflux valve having bye pass arrangement and 125 mm dia. and capable of with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
254Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 10.00 sqmm or of Suitable sizes.
255Supply of Leader /Kirloskar make 150 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 150 mm dia. of rising i.e. 150 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
256Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
257Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
258Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
259Providing and laying delivery pipe 150 mm dia. and common header 200 mm dia GMSERW pipe jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
260Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
261Supply of suitable cable for water level guard
262Supply of supporting clamps.
263Supply of cable clips of required size.
264Erection of all equipment from Sr. No. 173 to 186 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
265Pumping Machinery Submersible (LWSS Kandapattan Dhawali):- Supply ofsubmersible pump ofKSB /Calama/Johnston/SU/Kirloskarmake conforming to BIS:8034-1976 or latest suitable for lifting Water (latest with upto date ammendments) fitted with bronze impellers/ suitable alloye. The pump should be fitted with free flow impellers of bronze/suitable alloys directly coupled to squirrell case electric induction motor of same make as (manufacturer standard) conforming to BIS: 9283-1979 (latest with upto date ammendments ) and totally water prrof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearing & provided with stainless steel thrut bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard errection clamps, manufacturer cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
266SITE CONDITIONS:- Total Head 69.89mtrs Discharge required 10.38LPS each set. No. of Pump required.2Nos1set act as stand bye. Location of the site of installation of machinery: The site is located at a distance ofKm from The Altitude of :- The Altitude of place is 644 mtrs above MSL Type of Current:-AC three phase supply withRateVoltage:-415+/-10% Type of water and its Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value5.00 HP-- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 95 mtrs Dia of Rising main 125 mm dia. No of working hours.8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
267Supply of Oil immersed Star Delta Starter of reputed make i.e MEI/Kilburn conforming to BIS 8544 -( Part -II) 1987 latest with upto date amendments for squirrel cage induction motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release and gas-pots, time legs, under voltage release & initial oil filingsuitable for 20 HP motor.
268Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel boardshall be subject to approval of Engineer-in-Charge.
269Ammeter AC supply, 100 mm square type auto electric of AE/ L&T Rishab make of 0-63 Amp. capacity for above motor with selector switches conforming to IS-1248 (Part - II)-1983 latest with upto date amendments.
270Voltmeter AC supply, 100 mm square type auto electric AE/ L&T Rishab make of0 - 500 Voltsrange for above motor with selector switches conforming toIS-1248 (Part - II)-1983 latest with upto date amendments.
271ICTP switches 63 Amp. with HRC fuses of Havells/L&T/standard /cromption make for required motor of 20 HPcapacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
272Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutralconforming to IS:8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendments of suitable rating.
273MCB/MCCB of 63 Amp suitable for motor of 20 HP capacity of Havells /standard /MDS/ Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto dateamendments with neutral linked under voltage release.
2743 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
27550 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
276Supply of Kirloskar/ leader make cast iron (class PN 1.00 ) double flanged sluice valve of 100 mm dia. and capable of with standing nominal seat pressure of 10.20 kg/cm2 as per IS :14846-2000.
277Supply of Kirloskar/leader make cast iron (class PN-1.60) double flanged (swing check type) reflux valve having bye pass arrangement and 100 mm dia. and capable of with standing nominal seat pressure of 16.32 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
278Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side 6.0 sqmm or of Suitable sizes.
279Supply of Leader /Kirloskar make 125 mm dia. cast Iron class PN-1.00 double flanged (swing check type) reflux valve having bye pass arrangement and 125 mm dia. of rising i.e. 125 mm for with standing nominal seat pressure of 10.20 Kg/Cm 2 as per IS: 5312 (Part-I) 2004
280Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced bytender.
281Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of requiredcapacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and otherelectrical equipment’s.
282Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
283Providing and laying delivery pipe 125 mm dia. and common header 150 mm dia GMS pipe Medium classas perIS:_1239-2004 jointed with MS flanges of table -17 as per IS: 6392-1971 (uptoa length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
284Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factorat site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of L&T/Finolex make formbus bar chambertocapacitor andalso including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
285Supply of suitable cable for water level guard
286Supply of supporting clamps.
287Supply of cable clips of required size.
288Erection of all equipment from Sr. No. 190 to 203 including cost of tees, bends, tapers and any other fittings required as per site conditions and as per direction of Engineer-in-charge.
289Centrifugal Pump (LWSS Proh ka Galloo 3rd stage):- Supply ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistagecentrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar make conforming to BIS 1520-1980) pump (Latest with up toto date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling sliperring squirrel cage screen protected drip proof electric induction motor of standard make such as Kirloskar/ NGEF/Cromption conforming to IS 12615-2018 and should be energy efficient IE2 complaint and TEFC type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts,m painting etc. and shall be and suitable for operation on the date given below:
290SITE CONDITIONS:- Total Head336.00 mtrs Discharge required15.01 LPS each set. No. of Pump required. 1.00 No. set Length of R/main 1850.00 mtrs. Dia of R/main150mm dia Location of the site of installation of machinery-The site is located at a distance of ------Km by road &KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :-The Altitude of place is900 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days.
291Providing ICTP Main Switch 250 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
292Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
293O.C.B. 200 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
294E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
295The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
296100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments.
297Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating.
298Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating.
299Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 250 Amp.
300ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 250 Amp.
301Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
302100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments.
303Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 25 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments
304Providing suitable Auto Trasformer starter of M.E.I / Kilburn.make as per IS:8544 (Part - IV ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
305Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
306Providing doubleflanged Cast iron sluice valve of Leader/Kirloskar make of 200 mm dia for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class PN-1.6)
307Providing double flangedCast steel sluice valve of Leader/Kirloskar make and size of 150 mm dia.and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS : 1414 / API - 600 (Class ASA-300) .
308Providing double flangedCast steel reflux valve of Leader/Kirloskar make andsize of 150 mm dia.and capable of with standing nominal seat pressure of 52 kg/cm2 as per: BS : 1868 / API - 600(Class ASA-300).
309Providing double flangedCast steel 200 mm non return valve of Leader/ Kirloskar make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS : 1868 / API - 600 (Class ASA-300) . .
310Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
311Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
312Installation of all the items appearing at Serial No. 207 to213 as per thesystematic drawingattached with the tender documents ( Drg.No.1)
313Providing and fixing double flanged 200 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
314The size of the various components to be as under:-
315(i) Suction pipe200 mm dia Min. length = 10 mtr.
316(ii)Delivery pipe 150 mm dia -do-= 6 mtr.
317(iii) Common Header200 mm dia-do-= 6 mtr.
318and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
319Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
320(i)Motor side:70mm2 Min length = 20 mtrs.
321(ii)Supply side: 95 mm2Min. length =10 mtrs.
322Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
323Centrifugal Pump(LWSS Khanoud):- Supply ofhorizontal spindle horizontal split casing/end suctions (back pull out arrangement) Single/double/multistagecentrifugal pumps or combination of pumps in series/parellel of Mather & Platt/KSB/ Kirloskar make conforming to BIS 1520-1980) pump (Latest with up toto date amendments, read with BIS: 9137-1978(latest edition)suitable for lifting clear/raw water of under mentioned characteristics with bronze/Suitable alloy, priming funnels, casing ring andshaftmotor of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on acommon MS/Cast steel plate (base platefrom the principal manufacturer of pumping set) to coupling sliperring squirrel cage screen protected drip proof electric induction motor of standard make such as Kirloskar/ NGEF/Cromption conforming to IS 12615-2018 and should be energy efficient IE2 complaint and TEFC type ( latest with upto date ammendments) it should include the cost of bearings, nuts & bolts,m painting etc. and shall be and suitable for operation on the date given below:
324SITE CONDITIONS:- Total Head300.00 mtrs Discharge required5.11 LPS each set. No. of Pump required. 2.00 Nos sets (1 act as stand bye) Length of R/main 1650.00 mtrs. Dia of R/main65mm dia Location of the site of installation of machinery-The site is located at a distance of Km by road &KM on head load (for the installation of both machinery). Head Load (for the installation of both machinery). The Altitude of :-The Altitude of place is697 mtrs above MSL Type of Current:- AC three phase supply with Rate Voltage:-415+ Type of water and its Charactristics of water a) Ambient Temperature b) Turbidity NTU NTU c) Hardness260 Mg/Ltrs -- d) PH Value 7.5-- e)Total Solid Mg/Lts)PH Value-- No of working hours.16 Hours. Limit of Pump(-) 15% (+) 10% R. M.P. of PumpingRPM(or to be specified by the tenderer) Test run16Hours continueously for 7 days.
325Providing ICTP Main Switch 125 Amp with HRC fuses / Side handled operated Change over switch of L&T/Crompton/Standard/Havells make suitable capacity Operational rating as per IS: 4064 (Part - II) 1978 with up to date amendments immediately after the power meter of HPSEB
326Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
327M.C.B. 125 Amp. Havell/MDS/Standard of make of suitable capacity on incoming feeder with or without initial oil filling as the case may be withneutral linkedunder voltage releases as per IS: 2516 (Part - II) 1985 with up to date amendments with.
328E.L.R. of Havell/MDS/INDETEC make as per IS: 2516 (Part - II) 1985 with upto date amendmentwhich should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
329The voltage monitor relay of L&T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 1248 (Part - II ) 1983 (Latest edition).
330100mm square type A.C. supply voltmeter of AE/L&T Rishab make of suitable range with selector switches as per IS: 4064 (Part - II ) -1978 with up to date amendments.
331Power factor meter of AE/L&T Rishab make as perIS: 1248 (Part - V ) 1983(Latest edition) with up to date amendments of suitable rating.
332Frequency meter of AE/ L&T Rishab make as perIS: 1248 (Part - IV ) 1983( Latest edition) with up to date amendments of suitable rating.
333Bus bar chamber with copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11354-1985 read with IS 5578-1985 with up to date amendments 125 Amp.
334ICTP switches with HRC fuses ofL&T/ Standard/Havells make and of suitable capacity as per IS: 4064 (Part - II) -1978 with up to date amendments. 125 Amp.
335Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I & II) with up to date amendments.
336100mmSquare type AC supplyAmmeter of AE /L&T Rishab make of suitable range (0-200) with selector switches and CTS operated as per IS:1248 (P-II) 1983 with up to date amendments.
337Capacitor of L&T make as per IS:2834 -1986 with up to date amendments toraise the power factor at site to 0.95 for direct connections to induction motor individuallyof 11 KVAr ratingaccordingto HP offered including cables as per relevant ISI code (of L&T/Finolex make) from bus bar chamber to capacitor and also including ICTP switches of appropriate rangeas per IS: 4064 (Part - II) 1978 withupto date amendments
338Providing suitable Oil immersed Star Delta starter of M.E.I / Kilburn make as per IS:8544 (Part - II ) -1987 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release with or without initial oil filling as the case may be with single phase preventor as per IS 1248 (P-V)-1983 with up to date amendments.
339Providing Hour run meter of recommended make as per IS: 722 (Latest edition)
340Providing doubleflanged Cast iron sluice valve of Leader/Kirloskar make of 80 mm dia for the suction pipe and capable of withstanding the normal seat pressure as per IS: 14846-2000 with up to date amendments. (Class PN-1.6)
341Providing double flangedCast steel sluice valve of Leader/Kirloskar make and size of 65 mm dia.and capable of with standing nominal seat pressure of 52 kg/cm2 as per BS : 1414 / API - 600(Class ASA-300).
342Providing double flangedCast steel reflux valve of Leader/Kirloskar make andsize of 65 mm dia.and capable of with standing nominal seat pressure of 52 kg/cm2 as per: BS : 1868 / API - 600 (Class ASA-300) .
343Providing double flangedCast steel 65 mm non return valve of Leader/ Kirloskar make having bye pass arrangement for rising main and capable of with standing normal seat pressure of 52 kg/cm2 as per BS:1868/API - 600 (Class ASA-300). .
344Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 75 Kg/cm2
345Providing 100mm dia. vacume dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range 0 - 760 mercury.
346Installation of all the items appearing at Serial No. 220 to226 as per thesystematic drawingattached with the tender documents ( Drg.No.1)
347Providing and fixing double flanged 80 mm piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
348The size of the various components to be as under:-
349(i) Suction pipe 80 mm dia Min. length = 10 mtr.
350(ii)Delivery pipe 65 mm dia -do-= 6 mtr.
351(iii) Common Header 80 mm dia-do-= 6 mtr.
352and will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed.
353Providing and laying copper PVC insulated armoured power cable (one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of L&T/Finolex make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
354(i)Motor side:16mm2 Min length = 20 mtrs.
355(ii)Supply side: 25 mm2Min. length =10 mtrs.
356Providing and fixing double loop earthing and G.I. plate 600 mm x 600mm x 3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 32 mm x 3_mm G.I. strips & G.I. wire as per IS: 3043 -1987 withup to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.