| 1 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 2 | 3½ X 300 sq. mm (70mm) |
| 3 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 4 | Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable ofFollowing size, 1.1 KV grade, direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. etc. as required [conforming to I.S-1554/1/8].(Make- Havells/ Gloster/ Polycab/ RR kabel/ KEI/ Universal). |
| 5 | 3½ X 300 sq. mm |
| 6 | Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable ofFollowing size, 1.1 KV grade, direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as required.[Conforming to I.S-1554/1/8].(Make- Havells/ Gloster/ Polycab/ RR kabel/ KEI/ Universal). |
| 7 | 3½ X 300 sq. mm |
| 8 | Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable of Following size, 1.1 KV grade in the cable tray/ panel as required. [Conforming to I.S-1554/1/8]. (Make- Havells/ Gloster/ Polycab/ RR kabel/ KEI/ Universal) |
| 9 | 3½ X 300 sq. mm |
| 10 | Supplying and laying of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable of Following size, 1.1 KV grade in the existing RCC/ HUME/ METAL pipe as required. [Conforming to I.S-1554/1/8]. (Make- Havells/ Gloster/ Polycab/ RR kabel/ KEI/ Universal). |
| 11 | 3½ X 300 sq. mm |
| 12 | Supplying and laying and Fixing of PVC insulated, PVC sheathed XLPE aluminium conductor armored cable ofFollowing size, 1.1 KV gradeon wall surface as required. above 185 sqmm. and upto 400 sqmm (clamped with 40x3 mm MS flat Clamp[conforming to I.S-1554/1/8]. (Make- Havells/ Gloster/ Polycab/ RR kabel/ KEI/ Universal). |
| 13 | 3½ X 300 sq. mm |
| 14 | Supplying and laying 150 mm dia G.I pipe in road including making hole with boki etc. complete as required. |
| 15 | Making the corecut out of 150 mm dia in RCC wall of 150mm thickness including making good the same etc. as required. |
| 16 | Design, Fabrication, Supplying, testing & commissioning of front operated cubicle type compartmentalised, front access free standing, dust and vermin proof (IP 66)Meter panel board panel of 2100x 1200x 400 mm size suitable for use at 415 volt, 3 phase, 4 wire, 50 hertz system suitable for fault level of required value symmetrical at 415 volts, made out of 2mm thick CRCA MS sheet with hinged, gasketed(metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/ T/ Flat/ sections including 3 mm thick gland plates on top and bottom andlifting hooks andGI earth strip of required size with 2 nos. earthing terminal and powder coated paint finish of approved shade over metalsurface cleaned and treated with seven tank process complete with frame duly erection in ground and interconnection with copper conductor etc. as specification, as complete as required confirming to IS8623:93as below. |
| 17 | i) 630 amp, 4P, 50KA, 50HZ, 415V, AC MCCB with Thermal release (Make L&T, type DN3-630N)-- 01 Nos.ii) 250 amp, 4P, 50KA, 50HZ, 415V, AC MCCB with Thermal release (Make L&T, type DN2-250N)---04 Nos. iii) Illuminated Lamp ---03 Nos.iv) Earth Studs---- 02 Nos. v) Danger plate-----02 Nos. |