| 1 | Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick (below or above ground level) complete all as specified and directed. |
| 2 | M&L for 150mm thick Cement concrete Type B-1, 1:2:4(20mm graded aggregate) as in hardstandings or similar works complete all as specified and directed. |
| 3 | M&L for Finishing surface of concrete roads, pavements, by brooming, complete all as specified and directed. |
| 4 | Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade ‘A’, complete all as specified and directed. |
| 5 | Dismantlingfloor, hearth or wall tiling including cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premises |
| 6 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick (Square/ rectanglar) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 7 | Demolition ofprecast concrete blockmasonrywork built in Cement mortar or cement lime motar complete all as specified and directed. |
| 8 | M&L for pre-castcement concrete block (Type C-1 1:3:6, 20 mm graded agg)masonry with solid blocks exc. 10 cm in width and setting in CM 1:6, complete all as specified and directed. |
| 9 | Demolition of cement concrete (reinforced) in roofs , floors ( other than ground floors ), beams, staircases, landing, chajjas and similar suspended work. |
| 10 | M&L for RCC 1:2:4,Type B-1(20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like |
| 11 | M&L form work to sides and soffits of suspended slabs such as roof slabs , landings and similar work not exc 200 mm thick (horizontal or sloopping) for flat fair finished surfaces complete all as specified and directed. |
| 12 | S&F Mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips |
| 13 | M&L for 15mm thick rendering in CM 1:6 on brick or concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 14 | M&L for preparation of newly plastered surfaces of walls including cornices, pillasters etc, and applying two coats of oil emulsion distemper over and including one coat of chalk whiting preparatory to distempering complete all as specified and directed. |
| 15 | Dismantling wall and ceilingboard of insulation boards/ slabs/ blankets any description and thickness in any posn complete all as specified and directed. |
| 16 | Dismantling timber scantling under 40 Sqcm on flats, rails, posts, rafter, purlins etc.in unframed work complete all as specified and directed. |
| 17 | M&L for second class soft wood (Kail) plain fillets, rectanglar or triangular in section clean sawn secured with nails exceeding 13 Sq cm and not exceeding 25 Sq cm complete all as specified and directed. |
| 18 | S&F prelaminated particle board 12 mm thick interior grade, prelaminated one side with decorative lamination & other side balancing white lamination fixed to piano hinges fixed with screws to timber frame work as in walls/doors, complete all as specified and directed. |
| 19 | S& F 75 mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified |
| 20 | S&F 100 mm hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified |
| 21 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised (Width of flaps (when open) 30 mm)complete all as specified |
| 22 | Taking down chowkhats or frames with shutters (without taking offshutter from the frame) wooden/Aluminium exceeding 1.5 Sqm but n exc 4.00 Sqm each complete all as specified and directed. |
| 23 | S&F Aluminiumframe for door,window / ventilaror/partitions with one or more rebateincluding joining cleat for fixing etc(for double glazing shutter), complete all as specified and directed |
| 24 | S&F Anodised aluminiumdoor shutters, aluminium sectionweighingnot less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles (150 mm) 02 Nos in each door, hinges (100 mm ) 03 Nos each door,anodised aluminium snap beading, screws, etc complete all as specified and directed by Engr-in-charge. |
| 25 | S&F aluminium alloy, anodised,sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded setion or cast aluminium alloy and fixed 250 mm long complete all as specified and directed. |
| 26 | S&F aluminium anodised barral tower bolt of extruded section 150 mm size fixed with screws complete all as specified and directed.. |
| 27 | S&F sheet glass 4 mm thick ordinary quality exc 0.5 Sqm in each panes . |
| 28 | M&L for Prelaminated particle board 9mm thickinterior grade, prelaminated oneside with decorativechoice lamination & otherside balancing white lamination fixed in aluminum frame complete all asspecified . |
| 29 | Taking down old unsv copper/aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 30 | Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all asspecified and directed. |
| 31 | Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc. complete all as specified and directed. |
| 32 | M&L for point wiring for one light/fan/call bell point controlled by one 5 Amp switch with 1.5 Sqmm PVC (FRLS-H) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLSH) insulated unsheathed multi stranded copper conductor cable draw in & incl PVC surface casing \"N\" capping double lock type to be fixed with the help of rawal plugs & screws incl all fittings such as Tee, connector pieces, L-junction etc on joints including CI/MS/PVC sunk boxes for mounting switches, sockets, regulators etc with 3 mm thick plastic laminated sheet cover of adequate size for one light/fan/bell point controlled by one switch and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed.. Notes : (a) Wiring shall be done by using proper colour coding.(b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC casing \"N\" cappingshall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge. |
| 33 | Description all as per serial item No 32 here-in-before but one 5 pin socket outlet, 5 amps on the same board complete all as specified and directed. |
| 34 | Description all as per serial item No 32 here-in-before but one 5 pin socket outlet, 5 amps, independent complete all as specified and directed. |
| 35 | Description all as per serial item No 32 here-in-before but for one 5 pin socket outlet 15 Amps on Independent board with cables 2.5 sqmm size complete all as specified and directed. |
| 36 | S&F switch piano, flush type single pole one way 6 Amp, 240 volts ISI marked complete all as specified and as directed. |
| 37 | S&Fsocket outlet 2 in 1, 3 pin, 6 A ISI marked complete all as specified and directed. |
| 38 | S&Fsocket outlet 3 pin, 6/16 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and directed. |
| 39 | S&F switch piano, flush type single pole, one way 16 Amps, 240 volts ISI marked complete all as specified and directed. |
| 40 | S&F Ding Dong Bellmusical type AC 230 volt single pole complete all as specified and directed by engineer in charge. |
| 41 | S&F Bell Push flush type 5A switch, complete all as specified and directed. |
| 42 | S&F ceiling rose, 3 terminal surface type complete all as specified and directed. |
| 43 | S&Fangle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and directed. |
| 44 | S&F LED Bulb 9 watt withangle lamp holder PVC/Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and directed. |
| 45 | Supply & fixing surface /wall mounted light fittingpre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make-Crompton Greaves /Philips/Bajaj |
| 46 | Supply & fixing energy efficient LED light of 10/12 Watt of length - 02 Feet long having minimum 1100-1300 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make-Crompton Greaves /Philips/Bajaj |
| 47 | Taking down old burnt out bulk head fitting any type and Supply and FixLED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP66 complete all as specified and directed.Make-Crompton Greaves /Philips/Bajaj |
| 48 | S&F in replacement of existing worn out ceiling light with enviromental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36/40/42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make-Crompton Greaves /Philips/Bajaj |
| 49 | S & F Sheet metal enclousers, TPN Distribution board 4 way, double door complete with appropriate size bus bar, neutral link and Earth Bar fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.Note:- Distribution board and MCB\"s should be same make. |
| 50 | M&Ldistribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCB\"s should be same make. |
| 51 | M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCB\"s should be same make. |
| 52 | S&F 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 53 | S &F of SPN 40 to 63Amp rating 240V, 10KA \"B\" curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 54 | S & F of 415V 10KA \"B\" curve TPN 63 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 55 | M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 6.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding. |
| 56 | Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level ,connected to galvanised earth lead wire 4.0mmby means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrodeand including GI pipe light grade 40mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thickwith 8mm dia TMT bars at 140mm C/C both ways,with lifting handle, watering pipe of GI medium grade 40mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and all as specified. |
| 57 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed. |
| 58 | Supply and Fixingin repairs 4ft length ultra bright 20W LED polycarbonate tuberod with THD<10% with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders (single side connection) complete all as specified and directed.Make: Bajaj tube rod BLRB20WLED/Havells Cat part of tube rod TITANIAEO1213T8SSTL20WLED865SPC/Polycab Cat part tube rod LTU0101009P. |
| 59 | Taking down old unsv cable & Supply and lay cable XLPE Insulated screened Meter PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core all as spfd and directed. |
| 60 | Excavation in trenches, getting out in hard/densesoiland also including road cutting not exceeding 1.5m deep and not exc 1.5m widecomplete all as specified and directed. |
| 61 | Removing of surplus soil to a distance not exceeding 50 mtr complete all as specified and deposited where directed at a level not exceeding 1.5m above the starting point all as specified. |
| 62 | Returning filing in including spreading levelling, watering & well ramming in layers not exceeding 25 Cm thick all as specified. |
| 63 | Material & Labour for sand cushioning 15 cm below and 8 cm above the U/G cable laid (total depth of send shall be 23 cm) complete all as specified & directed by Engr-in-Charge. |
| 64 | M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site. |
| 65 | M & L for GI pipe light grade 40 mm dia galvanised with all fitting to be laid in trench/wall/pole for the protection of cable under road/poles/wall/floor etc complete and PCC path complete all as directed by Engineer-in-chargeincluding fixing clamps etc. with pole or passing through road/floor etc complete. |
| 66 | Deduct Credit for Demolished/Dismantled material (-) Rs 21,530.20(Minus) Schedule \"A\" Sec-II (Credit Schedule)Note :Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the \"Contract Sum\". |