Assam Rifles-AR has published Tender For Repair / Maintenance And External Distempering Including Periodical Services And Rewiring Of T-Iv Qtr At Cob Tening Of 25 Ar. Submission Date for this Tender is 19-07-2023. Electrification Work Tenders in jalukie Nagaland. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | SCHEDULE ‘A’ PART - I (Repair of Building) |
2 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats) including prepariong surface by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. |
3 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
4 | Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface |
5 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
6 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete with 2nd class teak wood beading 62X19 mm. |
7 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (Group B) as per direction of Engineer in Charge. |
8 | Wiring for light/ power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
9 | Supplying and fixing 5/6 amps modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
10 | Supplying and fixing3 pin 5/6 amps modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
11 | Supplying and fixing 15/16 Amp modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
12 | Supplying and fixing6 pin 15/16 amps modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
13 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
14 | Supplying and fixing 3 Module (100mmX75mm) GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
15 | Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
16 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
17 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
18 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. |
19 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. (Payment of tube to be paid Separately) |
20 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep. |
21 | Supplying and fixing 12 wayDouble door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
22 | Supplying and fixing 40A rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
23 | Supply and fixing 10 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required of 5amp. |
24 | Wiring for circuit/ submain wiring alongwith earth wire with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail