Tender For Operation And Maintenance Of 11.20 Mld Ground Water Treatment Plant At Rampur Including Operation Dtws, Over Head Tanks And Rising Pipe Lines Including Specials At Different Locations Under Dws Sub-Division-I, Collegetilla During The Year, agartala-Tripura

Urban Development Department-UDD has published Tender For Operation And Maintenance Of 11.20 Mld Ground Water Treatment Plant At Rampur Including Operation Dtws, Over Head Tanks And Rising Pipe Lines Including Specials At Different Locations Under Dws Sub-Division-I, Collegetilla During The Year. Submission Date for this Tender is 24-07-2023. Pipe Laying Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

38455248
Tender For Operation And Maintenance Of 11.20 Mld Ground Water Treatment Plant At Rampur Including Operation Dtws, Over Head Tanks And Rising Pipe Lines Including Specials At Different Locations Under Dws Sub-Division-I, Collegetilla During The Year
Open Tender
Indian
Tripura
agartala
24-07-2023

Tender Details

Operation And Maintenance Of 11.20 Mld Ground Water Treatment Plant At Rampur Including Operation Dtws, Over Head Tanks And Rising Pipe Lines Including Specials At Different Locations Under Dws Sub-Division-I, Collegetilla During The Year 2023-24.

Key Value

Document Fees
INR 1000 /-
EMD
INR 234083.0 /-
Tender Value
INR 1.17 Crore /-

BOQ Items

Name of Work:Operation and Maintenance of11.20 MLD Ground Water Treatment Plant at Rampur including operation DTWs, Over Head Tanks and rising pipe lines including specials at different locations under DWS Sub-Division-I, Collegetilla during the year 2023-24. Job No.43/SE/TJB/2023-2024
Sl. No. Item Description
1Operation of DTW"s by deploying Pump Operator in/c. Reliever to ensure daily supply of Raw water to plant in/c. relievers &in/c. operation of sluice valves, etc. as per requirement & as per direction of the Engineer-in-charge.
2Operation of Plant by deploying Pump Operator"s & Helpers in/c. relievers for operating of clear water pumps in/c. operation of all components/units within the Plant like alum dosing, lime dosing, chlorine dosing, clariflocculator, back washing, etc. completeas per requirement & as per direction of the Engineer-in-charge.
3Pump Operator:
4Helper:
5Conducting different laboratory tests by deploying qualified and experienced chemist and other staff"s as per requirement to ensure quality of treated water as per guideline of WHO/BIS parameters and supplying of testing apparatus and lab chemicals
6Providing proper round the clock security arrangement for DTWs, OHT& W.T.P.
7Operation of Sluice valves of various OHT’s at different locations by deploying Helpersas per requirement & as per direction of the Engineer-in-charge.( For Battala OHT)
8Providing and applying of different chemicals for production of quality treated water as per guideline of WHO/ BIS parameters.
9Alum (Grade- 4) in/c 15-16 % alumina content.
10Hydrated Lime
11Salt
12Providing and mixing bleaching powder grade-I, active chlorine should be minimum 33% (16 hours operation) X 30 days in/c applying, loading and stacking etc. complete in all respect as per direction of the Engineer-in-Charge.
13Providing and fixingC.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) as perCPWD specification and direction of the Engineer - in - charge.
1480 mm dia. PN- 1.6
15100 mm dia. PN- 1.6
16150 mm dia. PN- 1.6
17250 mm dia. PN- 1.6
18300 mm dia. PN- 1.6
19400 mm dia. PN- 1.6
20Charges for push-on ( Tyton ) joints to centrifugually ( Spun ) cast iron pipes or ductile iron pipes including testing of joints and including the cost of rubber gasket as perCPWD specification and direction of the Engineer - in - charge.
21150 mm dia.
22200 mm dia.
23250 mm dia.
24300 mm dia.
25350 mm dia.
26Providing and fixing C.I. non-return valveofapproved quality as perof CPWD specification and direction of the Engineer - in - charge.
27250 mm nominal bore
28Providing and fitting fixing of pressure meter ( 0.0 - 14.0 Kg/ sqcm.) as per specification and as per specification and thedirection of the Engineer - in-charge.
29Welding by gas or electric plant in/c. transportation of plant at site etc.complete as per standard design.
30Dismantlingold C.I. / D.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site lead upto 50 metre as perCPWD specification and direction of the Engineer - in - charge.
31200 mm dia.
32250 mm dia.
33300 mm dia.
34400 mm dia.
35Providing andfixing DI specials as perCPWD specification and direction of the Engineer - in - charge. a) DI Collar flanged socketted
36150 mm dia.
37200 mm dia.
38250 mm dia.
39300 mm dia
40400 mm dia.
41Providing andfixing DI specials as perCPWD specification and direction of the Engineer - in - charge. b) DIFlanged socketted tail piece
42150 mm dia.
43200 mm dia.
44250 mm dia.
45300 mm dia
46400 mm dia.
47Providing andfixing DI specials as perCPWD specification and direction of the Engineer - in - charge.c) DIFlanged spigotted tail piece
48150 mm dia.
49200 mm dia.
50250 mm dia.
51300 mm dia
52400 mm dia.
53Providing andfixing CIDF Butterfly valvewith bolts, nuts, rubber insertionsetc. complete as perCPWD specification and direction of the Engineer - in - charge. ( The tail pieces, tappers etc if required will be paid separately )
54250 mm dia.
55300 mm dia
56400 mm dia.
57Providing and fitting fixing of moving iron type, Range 0-500 V, 96 mm x 96 mm size AC Volt meter ( L & T / AE make) with selector switch as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
58Providing and fitting fixing of moving iron type, Range 0-100/0-200 amps, 96 mm x 96 mm size AC Amps meter direct reading type ( L & T / AE make) with selector switch and CT coil as a electrical instrument of the pannel board as per specification and direction of the Engineer-in-charge.
59Rewinding of Horizontal Motor suitable for centrifugal pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3 ) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge.
600.5 - 1.5 HP
612.0 HP
62Providing and fixing MS bolts including nuts and washers complete as per standard design:- Upto 300mm length.
63Providing and fitting fixing of Fully Automatic Star Delta type Motor starter ( 3 ph. 50 Hz, 415V, in Steel Sheet Enclosures with Contractors and Timer etc. complete suitable for submersible Pump L & T, BCH, ABB make as per specification and direction of the Engineer-in-charge.
6425 HP/18.5 kw Relay range within 13-21 + 10%
6535 HP/26 kw Relay range within 20-32 + 10%
6650 HP/37 kw Relay range within 28-42 + 10%
67Providing and fitting fixing steel sheet enclosed switch fuse unit(suitable for DIN fuses), triple pole with Neutral Link (TPN),415/500 Volt, L & T / Havells / BCH make etc. completeas per specification and direction of the Engineer-in-charge.
6863 Amps
69100 Amps
70200 Amps
71250 Amps
72630 Amps
73Repair and maintenance of 30 HP Motor suitable for 15000 GPH capacity submerssible pumpset by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge.
74Repair and maintenance of 20 / 22.5 HP Motor suitable for 10000 GPH capacity submerssible pumpset by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge.
75Repair and maintenance of 35/40 HP Motor suitable for 20000 GPH capacity submerssible pumpset by complete dismantling in/c providing & fitting fixing of PVC ( IS : 8783-1978 ) insulated electro grade copper ( IS : 613-1984 ) conductor winding in stator & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge.
76Rewinding of Motor suitable V.T. pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS : 13730 Part-3 ) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer-in-charge.
77125 HP
78Providing and fitting fixing Single phasing preventor + selectable under voltage + selectable over voltage on delay 5 sec & off delay 15 sec phase asymmetry 10% L&T/BCH/HAVELS/Siemens etc. Make complete as per specification and direction of the Engineer-in-charge.
79R/mtc. of different dia CI sluice valves by providing and re-placing complete with bolts, nuts, rubber insertions etc.as per direction of the Engg-in- charge.
8080 mm dia.
81100 mm dia.
82200 mm dia
83Making supplying and fitting fixing of MS spindles in/c. socket for sluice valve as per departmental sample
8480 mm dia.
85100 mm dia.
86200 mm dia.
87250 mm dia.
88Labour charge for lifting of 20,000/15,000/10,000/7,500/5,000 GPH capacity water lubricated vertical submersible pump motor sets in/c. column pipe assembly by heavy duty chain pulley block as per direction of the Engineer-in-charge.
89Labour charge forfitting-fixing & lowering of 20,000/15,000 /10,000/ 7,500/5,000 GPH capacity water lubricated vertical submersible pump motor sets in/c. column pipe assembly by heavy duty chain pulley block as per direction of the Engineer-in-charge.
90Providing and fitting fixing of directly mounting Thermal overload Relays of L&T make, Type ML as per direction of Engg-in-charge.
91Relay Range(A) 20-32 Cat No. SS9185900E0
92Relay Range(A) 28-42 Cat No. SS9185900F0
93Type Mk1 Relay Range(A) 9-14 Cat No. SS9003500A0
94Providing and fitting fixing of 3 pole power contactors-Type ML ( Standard coil voltage AC-3 Duty, 415 V, 50Hz, Motor Rating AC-3 Duty, 415V, 50Hz3Ph)of L&T make as per direction of Engg-in-charge.
95Type ML2 AC 3 Rating(A) 32, AC 1 Rating(A) 40, Aux Contacts 2 NO + 2NC Cat No. SS90701
96Type ML2 AC 3 Rating(A) 40, AC 1 Rating(A) 45, Aux Contacts 2 NO+ 2NC Cat No. SS90721
97Providing and fitting fixing of spare contact kit ML Series of L&T make as per direction of Engg-in-charge.
98Type ML2 Cat No. SS95307
99Type ML3 Cat No. SS95309
100Providing and fitting fixing of spare coil ML Series of L&T make as per direction of Engg-in-charge.
101Type ML2/ML3 Cat No. SS90545
102Providing and fitting fixing of combination coil MK1 of L&T make Cat No. SS90443 as per direction of Engg-in-charge.
103Providing and fitting fixing of Electronic Timers Type ST-100,415 V, 50Hz, 3-30 secs, L&T make, Cat No. ST803280000 as per direction of Engg-in-charge.
104Providing and fitting fixing open execution type FN (TPN) S-D-F suitable for DIN fuse -link, triple pole with neutral link (TPN), 415/500 volt, L&T make.
105FN 63 TPN/FP CE, Cat No. SK95704
106FN 100 TPN, Cat No. SK95568
107Cylindrical Fuse Link type HF-63 amps, Cat No. SF90159
108Type DIN Fuse Link FN-100A, Cat No. SF94029
109Type DIN Fuse Link FN-125,S-D-F Cat No. SF94030
110Repair and maintenance of 7500/10000 GPH capacity submerssible pump by complete dismantling including providing and fitting fixing of all necessary spare parts ( conforming to IS : 8034 ) and reassembling the same including machining, servicing & necessary trial run as per specification and direction of the Engineer-in-charge.
111Bronze/SS Impeller
112Bronze grade LTB 2/ cutless rubber bush
113Bronze grade LTB 2/12% chromium steel grade shaft sleeve
114Stainless steel pump shaft
115Cast iron grade (FG200) discharge casing
116Cast iron grade (FG200) suction casing
117Cast iron grade (FG200) pump bowl/diffuser
118SS Impeller lock
119SS half coupling
120Stud bolt & nut
121Dismantling, repairing, reassembling, servicing
122Repair and maintenance of 15000/20000 GPH capacity submerssible pump by complete dismantling including providing and fitting fixing of all necessary spare parts ( conforming to IS : 8034 ) and reassembling the same including machining, servicing & necessary trial run as per specification and direction of the Engineer-in-charge.
123Bronze/SS Impeller
124Bronze grade LTB 2/ cutless rubber bush
125Bronze grade LTB 2/12% chromium steel grade shaft sleeve
126Stainless steel pump shaft
127Cast iron grade (FG200) discharge casing
128Cast iron grade (FG200) suction casing
129Cast iron grade (FG200) pump bowl/diffuser
130SS Impeller lock
131SS half coupling
132Stud bolt & nut
133Dismantling, repairing, reassembling, servicing
134Repairing of V.T. pumps by providing and replacing of G.M. bush for bowel ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
135For 100000 / 135000 GPH capacity V.T. pump
136Repairing of V.T. pumps by providing and replacing of G.M. bush for suction case / discharge case ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
137For 100000 / 135000 GPH capacity V.T. pump
138Repairing of V.T. pumps by providing and replacing of Rubber bush for bowel ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
139For 100000 / 135000 GPH capacity V.T. pump
140Repairing of V.T. pumps by providing and replacing of MS lock ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
141For 100000 / 135000 GPH capacity V.T. pump
142Repairing of V.T. pumps by providing and replacing of bronze impeller ( conforming to IS : 1710 ) as per specification and the direction of the Engineer-in-charge.
143For 100000 / 135000 GPH capacity V.T. pump
144Repairing of V.T. pumps by providing and replacing of SS shaft ( SS-410) ) as per specification and the direction of the Engineer-in-charge.
145For 100000 / 135000 GPH capacity V.T. pump
146Repairing of V.T. pumps by providing and replacing of CI bowel case as per specification and the direction of the Engineer-in-charge.
147For 100000 / 135000 GPH capacity V.T. pump
148Repairing of V.T. pumps by providing and replacing of CI suction/discharge case as per specification and the direction of the Engineer-in-charge.
149for 100000 / 135000 GPH capacity V.T. pump
150Repairing line / top shaft of different capacity V.T. Pumps by welding, grinding, threading, centering etc. as per specification and the direction of the Engineer-in-charge.
151Providing & Installation of 10000GPH capacity x 76 mtr. Head water lubricated Submerssible Pump (Kirloskar/Crompton/KSB/DUKE/Texmo make) with maximum 8 stages coupled with required wet & non-over loading Submerssible Motor suitable for 340-440 volts, 3-phase, 50Hz, A.C. supply & star delta method of starting as per direction of the Engineer-in-Charge.
152Supplying , installation of water lubricated vertical submersible pump set having 15000 GPH capacity (Kiloskar/Crompton/Texmo/ KSB/DUKE make) upto required depth with G.I coloumn pipe in/cl. providing fitting fixing by necessary rubber washer, nuts and volts, M.S safety lamp etc. as per required size and making necessary electrical connection with main switch/ starter with motor in/cl.commissioning and trial run along with fitting of old one as per direction of the engg.-in-charge. (G.I Coloumn pipe will be paid seperately)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail