| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil : |
| 2 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:All kinds of soil : |
| 3 | Random Rubble masonry with hard stone in superstructure above plinthlevel and upto floor five level, including levelling up with cement concrete1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mmnominal size) and curing complete at window sills, ceiling level and thelike:Cement mortar 1:6 (1 Cement : 6 coarse sand) nallah |
| 4 | Dry random rubble masonry with hard stone in foundation and plinth:Without bond stone nallah |
| 5 | Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).First class kail wood |
| 6 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.First Class kail wood |
| 7 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :First class kail wood |
| 8 | Renewing glass panes, with wooden fillets wherever necessary :Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm) |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 10 | Chequerred precast cement concrete tiles 22mm thick in footpath andcourtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of the tiles, including rubbing, cleaning and curing complete,on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) .Medium shade using 50% white cement and 50% ordinary cement. |
| 11 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thicknessto be specified by the manufacturers) of 1st quality conforming to IS:15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4( 1 cement : 4 coarse sand) including pointing the joints with whitecement and matching pigment etc., complete In all colours, shades, except White, Ivory, Fume Red Brown |
| 12 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 13 | Distempering with oil bound washable distemper of approved brand andmanufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 14 | Applying priming coats with primer of approved brand and manufacture,having low VOC (Volatile Organic Compound) content.With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter |
| 15 | Painting with synthetic enamel paint of approved brand and manufactureto give an even shade.Two or more coats on new work |
| 16 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 17 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platforms. |
| 19 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 20 | Constructing masonry Chamber of specified size, in brick work withcommon burnt clay (non modular) bricks of class designation 7.5 incement mortar 1:4 (1cement :4 coarse sand) and R.C.C. top slab 1:1.5:3mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mmnominal size ) including necessary excavation, foundation concrete1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mmnominal size) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand) 12 mm thick finished with a floating coat of neat cementcomplete as per standard design.Chamber 60x60x75 cm |
| 21 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :250x16 mm |
| 22 | Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :150x10 mm |
| 23 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.100 mm |
| 24 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.: |
| 25 | 15 mm dia. nominal bore |
| 26 | 20 mm dia. nominal bore |
| 27 | 25 mm dia. nominal bore |
| 28 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 liter low level whiteP.V.C. flushing cistern, including flush pipe with manually controlleddevice (handle lever), conforming to IS:7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. |
| 29 | Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350mm and 340x410x265 mm sizesrespectively with automatic flushing cistern with standard flush pipe andC.P. brass spreaders with brass unions and G.I. clamps complete,including painting of fittings and brackets, cutting and making good thewalls and floors wherever required:One urinal basin with 5 literwhite P.V.C automatic flushing cistern. |
| 30 | Providing and fixing white vitreous china pedestal for wash basincompletely recessed at the back for the reception of pipes and fittings. |
| 31 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brasspillar taps, 32 mm C.P. brass waste of standard pattern, includingpainting of fittings and brackets, cutting and making good the wallswherever required :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 32 | Providing and fixing 100 mm sand cast iron grating for gully trap. |
| 33 | Providing and fixing mirror of superior glass (of approved quality) and ofrequired shape and size with plastic moulded frame of approved makeand shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 34 | Providing and fixing toilet paper holder Vitreous china |
| 35 | Providing and fixing 600x120x5mm glass shelf with edges round offsupported on anodized aluminum angle frame with C.P. brass bracketsand guard rail complete fixed with 40 mm long screws, rawl plugs, etc.complete |
| 36 | Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931 |
| 37 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cockof approved quality conforming to IS standards and weighing not lessthan 810 gms. |
| 38 | Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) ofstandard design and of approved make conforming to IS : 8931 |
| 39 | Providing and fixing PVC pipe of 4 kg presure per square meter of approved brand and quality like supreem, Prince, Phenolex are like as approved by Engineer incharge |
| 40 | 75mm dia |
| 41 | 50mm dia |
| 42 | 100mm dia |
| 43 | Providing and fixing of PVC bend of 4kg presure per square metre of approved brand and quality like supreema, prince, phenolex are like as approved by Engineer in charge |
| 44 | 75mm dia |
| 45 | 50mm dia |
| 46 | 100mm dia |
| 47 | Providing and fixing CI cover without frame for man holes of size 455x610mm CI 10m light duty the weight of the 10mm to be not less then 2 kg |
| 48 | Labour engage for cleaning of sludge/Mulba from septic tank |