| 1 | 11/0.4 KV 250 KVA Distribution Transformer |
| 2 | S/T Pole9Mtr. W/L 200 kg |
| 3 | RCC Muff |
| 4 | X-Arm {C.I. (100X50X5 mm) length 2800mm x2} for incomer line |
| 5 | M.S Angle Iron (50x50x6 mm) length (2800mm)x1 Nos. for LA\"s |
| 6 | X-Arm {C.I. (75x40x6 mm) length 2800mm x4} for supporting DO fuse unit & GO switch |
| 7 | Transformer LT Distt. Box and GO Switch fixing Assembly |
| 8 | MS Angle Iron (50x50x6 mm) length 2800mm x2 |
| 9 | MS Angle Iron (50x50x6 mm) length 450mm x1 |
| 10 | GO Switch Handle Supporting (C.I. 75x40x6 mm) length 460mm |
| 11 | G.O.Switch 400 Amp. |
| 12 | D.O.Fuse unit |
| 13 | Lightning Arrestors |
| 14 | Disc Insulator with Fitting |
| 15 | Stay Set completeProvided by HPSEBL |
| 16 | Stay Wire 7/3.15 mm ( @ 8.0 kg Per Stay Set) Provided by HPSEBL |
| 17 | LT Distribution Panel Box with ACB (1000A, 50 kA, 3P, 1No. ) |
| 18 | Pipe Earthing |
| 19 | Half Clamp (M.S. Flat 50X6 mm) |
| 20 | Full Clamp (M.S. Flat 50X6 mm) |
| 21 | M.S. Nuts and Bolts (Off Sizes) |
| 22 | A. Thimble |
| 23 | A. Thimble |
| 24 | Danger Plate |
| 25 | Barbed Wire |
| 26 | LT Cable (3.5 Core) 240 mm2 |
| 27 | AAAC 7/4.26 100 mm2 for jumpers |
| 28 | Aluminium Paint. |
| 29 | Prov. Lead Tine Solder 60:40 |
| 30 | Prov. Solder Flux |
| 31 | CT/PT Unit (PT:11KV/110V) (CT:10-400/5) |
| 32 | 3 Phase 4 Wire CT/PT operated HT Meter |
| 33 | Control Cable for HT metering 6mm2 PVC(1.1 kV, 4C, HR FRLS, Cu, Screen) |
| 34 | CT/PT Unit Belting & Knee Bracing |
| 35 | Channel Iron (75x40x6mm) Length 2800mm for CT/PT Unit |
| 36 | MS Angle Iron (50x50x6 mm) length 2800mm x4 |
| 37 | MS Angle Iron (35x35x6 mm) length 450mm x2 |
| 38 | Civil work i.e Transformer plinth a/w chain link fencing |
| 39 | Add Transporation Charges |
| 40 | Add Erection Charges |
| 41 | Prov.Steel Tubular pole 9 mtr.long |
| 42 | Prov.RCC Muff with concerete feeling |
| 43 | Prov. C.I.X-arm 1500x100x50x6 mm Single Pole)x3. |
| 44 | Prov. A.I. Knee Bracing Set (750x50x50x6)x2)x3 mm Single Pole)x3. |
| 45 | Prov. A.I. 1800x 50x50x6 mm for guarding for Single pole)x3mm |
| 46 | Prov. C.I. 2800x 75x40x6 mm for GO Switch (Length 2x2800)mmx2 |
| 47 | Prov. GO Switch Handle Supporting: Channel Iron(460x75x40x6)mm |
| 48 | Prov.33KV Isolator (1250A,26.2ka without earth switch |
| 49 | Prov. 33 kV VCB (36kV, 1250 A, 26.2kA, Outdoor type |
| 50 | Prov. 33 kV Transformer Control and Relay Panel with differential relay and REF relay |
| 51 | Prov. Pin Insulator with pinhellically formed fitting Provided by HPSEBL |
| 52 | Prov. 11 Disc Insulator set cleaves and tongue helically formed(Porcelain: 12 kV, BS, 90 KN) |
| 53 | Prov. H.T.Stay set Complete Provided by HPSEBL |
| 54 | Prov. H.T Earthing Set Complete(Coil earthing) |
| 55 | Prov. Stay wire 7/3.15 mm (@ 8.0 kg Per Stay set ) Provided by HPSEBL |
| 56 | Prov G.I.wire 8 SWG for guarding Across the road |
| 57 | Prov. HP AMD Windows 10All-in-One PC 23.8 inches 60.5 cm FHD Desktop PC Ryzen 3-3250U -8 GB/256GB SSD to operate Scada system (MR -15% Discount) |
| 58 | Prov. HP LaserJet 1020 Plus Single Function Monochrome Laser Printer (MR -12% Discount) |
| 59 | Danger Plate ( 203x200x1.6mm) |
| 60 | Prov.Nut & Bolt( off sizes ) |
| 61 | Barbed wire |
| 62 | Aluminum Paint |
| 63 | Prov.AAAC 7/3.81mm ( 80mm2 ) |
| 64 | Prov. Earth Hook HT 8\" Long |
| 65 | Prov. Half Clamp |
| 66 | Prov. Full Clamp |
| 67 | Prov. D.O Fuse Unit |
| 68 | Prov. Meggar/Insulation Tester 2500 V (Hand Operated,5000 Mega Ohm) |
| 69 | Prov. 11 KV GO Switch |
| 70 | Prov. Egg insulator HT |
| 71 | Add Transportation Charges |
| 72 | Add Erection charges of AAAC 7/3.81 mm sq.Laying, Stringing and sagging, Binding with insulator of conductor from insulator, De-Stringing |
| 73 | Add Erection charges of 33 kV VCB (36kV, 1250 A, 26.2kA, Outdoor type and 33 kV Transformer Control and Relay Panel with differential relay and REF relay. |
| 74 | Add Erection charges of 33KV Isolator (1250A,26.2ka without earth switch |
| 75 | Steel Tubular Pole 8 Mtr. Long |
| 76 | RCC Muff for 8 Mtr.Long Poles. |
| 77 | Shackle Insulator with D-Iron |
| 78 | Prov. Egg Insulator |
| 79 | Prov. Eye Hook Bolt |
| 80 | LT Stay Set Complete Provided by HPSEBL |
| 81 | Stay Wire 7/3.15mm @ 6.0Kg.Per Stay Set Provided by HPSEBL |
| 82 | GI Wire 8 SWG for guarding |
| 83 | M.S Nuts & Bolts (off sizes) |
| 84 | Prov. Aluminium paint |
| 85 | AAAC 7/3.81 mm2 (80mm2) |
| 86 | Erection charges for 3 phase LT Line |
| 87 | AddTransportation Charges |
| 88 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil. |
| 89 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 90 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) |
| 91 | Centering and shuttering including strutting, propping etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 92 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. |
| 93 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 94 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement. |
| 95 | Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) :Raised and cut pointing |
| 96 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 97 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) |
| 98 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work |
| 99 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 100 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 101 | 2 mm thick pvc/rubber tile flooring. plain, coloured, corbed, or mosaic or mottled finishlaid with approved adhesive on sub floor complete (sub- floor incuding damp proofing treatment to be measured separately for payment) |
| 102 | Grassing with Korean Turf Grass or equivalentincluding watering and maintenance of the lawn for 30 days or more till the grass from a thick lawn free from weeds and fit for moving including supplying good earth if needed (Including the cost forgrass as per Direction of Engineer In Charge. |
| 103 | Quantities are mentioned above are tentative and Actual Quantity shall be worked out after Check Survey to be carried out by the successful Tender and detailed Engineering and finalization of Tower location Chart.Payment shall be made as per Approved Bill of Material/Actual Quantities measured at site. |