Tender For Comprehensive Maintenance And Repairs To Cooling Appliances Package Acs And Central Ac Plant Wsa At Af Stn Naliya, naliya-Gujarat

Military Engineer Services-MES has published Tender For Comprehensive Maintenance And Repairs To Cooling Appliances Package Acs And Central Ac Plant Wsa At Af Stn Naliya. Submission Date for this Tender is 29-07-2023. Air Conditioner Tenders in naliya Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

38424701
Corrigendum : Tender For Comprehensive Maintenance And Repairs To Cooling Appliances Package Acs And Central Ac Plant Wsa At Af Stn Naliya
Open Tender
Indian
Gujarat
naliya
29-07-2023

Tender Details

Comprehensive Maintenance And Repairs To Cooling Appliances Package Acs And Central Ac Plant Wsa At Af Stn Naliya

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Jul-2023 1STAMD Date 29-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 29998.0 /-
Tender Value
INR 14.99 Lakhs /-

BOQ Items

Name of Work: COMPREHENSIVE MAINTENANCE AND REPAIRS TO COOLING APPLIANCES, PACKAGE Acs AND CENTRAL AC PLANT WSA AT AF STN NALIYA
Sl. No. Item Description
1Taking down the following existing worn out spares of window type Air Conditioner of 1.5/ 2.0 Ton capacity and S&F in replacement new spares of existing make and model complete all as specified and as directed:-
2Blower moter.
3Blower capacitor 4/2.5 MFD.
4Fan blade.
5Air filter PVC.
6Thermostat switch with knob.
7Front grill of PVC.
8Taking down thefollowing existing worn out spares of split type Air Conditioners of 1.5/ 2.0 Ton capacity and S&F in replacement new spares of existing make and model complete all as specified and as directed:-
9Blower motor indoor type.
10Blower motor outdoor type.
11Fan blade.
12Running/running capacitor of 50 & 60 MFD.
13Air filter for Indoor unit.
14Display for Indoor unit.
15Remote control (Hand set only) with battery.
16LDPE drain water pipe line 15 mm dia all as directed .
17M&L PCB Timer electronic switch with sensor suitable for existing make & model of split 1.5/ 2.0 Ton AC complete with hand set.
18M&L for opening the indoor unit front panel of wall mounted split type 1.5/ 2.0 Ton AC for cleaning and chemical wash the existing LDPE pipe for any block by blowing the pipe with air and cleaning the bottom water line of indoor unit for arresting leakage of water complete all as specified and as directed.
19S&F in replacement rotary / invt type compressor of split type AC 1.5/2 Ton capacity in position, charging of refrigerant gas of required quantity, brazing of discharge and suction line and leak testing complete all as specified and as directed
20All as per Item No. 04 above but for split type AC of 2.0 Ton capacity.
21M&L for top up/ Gas charging with refrigerant gas (R-22) for Air Conditioner window/ split / packaged/ chiller type of capacity 1.5/ 2.0/ 5.5 / 11.0/16.5/17/36 Ton after vacuuming and leak testing including brazing suction/ discharge line and testing complete all as specified and as directed.
22S&F in replacement of copper tubing (of dia 1/4" to 1/2" ) suction and liquid line from indoor to out door unit by compressing Ref Gas suitable for split AC of capacity 1.5 TR/ 2.0 TR including insulation on copper tubing complete all as specified and as directed. Each RM included Complete set of suction and discharge line)
23Supply and fix in repairs voltage stabilizer of capacity 5 KVA, 230 Volts, AC, 50 Hz with range 160 Volts to 250 Volts with variation 2.5%+-complete all as specified and as directed.
24Taking down existing split type AC of 1.5/ 2.0 Ton capacity, from one location and re- fixing the same in another location as directed, including replacement of 3 core copper cable require for connecting IDU & ODU, additional copper tube if required, cleaning the IDU and ODU for smooth functioning etc. complete all as specified and as directed.
25Taking out the window type AC of 1.5/ 2.0 Ton capacity, from one location and shifting to new location for re- fixing the same complete all as specified and as directed.
26S&F in replacement industrial plug and socket with single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 16 Amp/ 20 Amps capacity complete all as specified and as directed.
27S & F in replacement of PCB of indoor electronic switch suitable for 1.5 / 2 TR split AC Inverter Type complete.
28M&L for top up/ gas charging with refrigerant R-134 A of required quantity for water cooler/ water dispenser/ refrigerator/ deep freezer of any make including leak testing, necessary brazing of suction and discharge line and testing complete all as specified and as directed.
29M&L for servicing/ cleaning of complete indoor/ outdoor window type and split type air conditioner units of following size and capacity by means of adding, cleaning solution (HCL) or equivalent solution with water. The cleaning of the condenser and chiller units is done with use of nylon brushers till the scaling is removed complete all as specified and as directed.:-
301.5 TR capacity.
312.0 TR Capacity.
32M&L for servicing/ cleaning of following size and capacity of Water Coolers/ Refrigerators/ Deep freezers by cleaning of water cooler tank with use of bleaching powder and cleaning of condenser coil of water cooler/ Refrigerators/ Deep freezers by means of adding cleaning solution (HCL) or equivalent solution with water. The cleaning of the condenser and chiller units is done with use of nylon brushers till the scaling is removed complete all as specified and as directed:- Note:- (i) This service shall be carried out for three times in whole contract period and shall be measured as one unit "Each Job" for three services. Contractor will maintain a register for these services. (ii) The rate quoted by contractor is inclusive of any minor spares required for smooth functioning of AC i.e. replacement of copper wire, selector switches etc.
3340/ 80 Liters.
3480/120 Liters.
35M&L for top up/ Gas charging with refrigerant gas (R-410/R-32) for Air Conditioner window/ split type of capacity 1.5/ 2.0/ Ton after vacuuming and leak testing including brazing suction/ discharge line and testing complete all as specified and as directed.
36S & F in replacement of heating coil of 2KW capacity suitable for 4 KW capacity humidifier complete.
37S & F in replacement of heating coil of 3 KW capacity suitable for 09 KW capacity humidifier as per existing make and model all as directed by EIC.
38S & F in replacement of PCB of outdoor electronic switch suitable for 1.5 / 2 TR split AC Inverter Type complete.
39Supply & fixin repair new compressor sealed units as per existing make and model, including brazing/ welding of suction and discharge line, Includingfirst filling gas, cleaning or descaling of liquid line air dryer and leak testing complete, 5.5 Ton capacity suitable for 5.5/ (5.5X2)11/ (5.5x3)16.5 TR package AC complete all as specified and as directed.
40Supply & Fixin repair condenser motor of outdoor unit of any make and model as existing in position for unit dismantled including other connected accessories for 5.5 Ton/ (5.5x2) 11 Ton, (5.5x3)16.5 Ton Ton capacity package AC complete all as specified and as directed.
41Supply & Fix in repair condenser motor of outdoor unit of any make and model as existing in position for unit dismantled including other connected accessories of (8.5x2) 17 Ton capacity package AC complete all as specified and as directed.
42Supply & Fix in repair condenser motor of outdoor unit of any make and model as existing in position for unit dismantled including other connected accessories of (12x3) 36 Ton capacity package Chiller AC complete all as specified and as directed.
43All as per Item No. 23.00 above but blower motor of indoor unit suitable for 5.5 Ton capacity package AC.
44Dismantling and taking out following unserviceable compressors from the existing water cooler/ refrigerator/ deep freezer after cutting carefully the suction and discharge line and S&F in replacement new compressor including first filling of gas and refining serviceable accessories with brazing the suction and discharge line and leak testing complete all as specified and as directed:-
45Compressor hermetically sealed suitable for 40/ 80 liter capacity water cooler.
46Compressor hermetically sealed suitable for refrigerator of 165 to 310 Liters capacity.
47Compressor hermetically sealed suitable for 200 to 320 Liters capacity deep freezer.
48S&F in replacement thermostatic switchfor following appliances:-
49Water cooler 40/ 80 Liters capacity.
50Deep freezer of any capacity.
51Refrigerator 165 to 290 Liter capacity.
52S&F in repairs blower motor suitable for water cooler 1/32 HP or 1/35 HP, single phase, 230 Volts, 1300 RPM complete all as specified and as directed Make:- AUE/ GE Motors as approved by GE.
53S&F in replacement fan motor with blade suitable for Deep Freezer of any capacity complete all as specified and as directed.
54S&F in replacement of burn out PCB unit boxwith display unit complete with all connecting Items, of existing make, for 5.5 TR capacity package AC complete all as specified and as directed.
55S&F in replacement of burn out PCB unit boxwith display unit complete with all connecting Items, of existing make, for (5.5X2) 11 TR capacity package AC complete all as specified and as directed.
56S&F in replacement of burn out PCB unit box with display unit complete with all connecting Items, of existing make, for (5.5x3) 16.5 TR capacity package AC complete all as specified and as directed.
57S&F in replacement of burn out PCB unit box with displayunit complete with all connecting Items, of existing make, for (8.5x2) 17 TR capacity package AC complete all as specified and as directed.
58S&F in replacement of burn out PCB unit box with display and remote unit complete with all connecting Items, of existing make, for (12x3) 36 TR capacity package chiller AC complete all as specified and as directed.
59S&F in replacement "V" belt of existing size suitable for indoor unit of 5.5/ (2x5.5) 11/(5.5x3) 16.5 /(8.5x2)17 / (12x3)36 Ton capacity package/chiller type AC unit of existing make complete all as specified and as directed.
60S&F in replacement contactor, 3 Phase suitable for existing 5.5/(5.5X2)11 TR/ (5.5x3) 16.5TR/ (8.5x2) 17 TR/ (12x3) 36 TR capacity package type AC unit of existing make complete all as specified and as directed.
61Cleaning of outdoor condenser coil and indoor evaporating coil using suitable cleaning chemical, washing of filters after cleaning of paint the compact unit of various size of package type AC units of 5.5 TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed.
62Cleaning of out door condenser coil and indoor evaporating coil through suitable cleaning chemical,washing of filters after cleaning of paint the compact unit of various size of package type AC units of (5.5X2) 11 TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed. .
63Cleaning of out door condenser coil and indoor evaporating coil through suitable cleaning chemical, washing of filters after cleaning of paint the compact unit of various size of package type AC units of (5.5x3) 16.5TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed. .
64Cleaning of out door condenser coil and indoor evaporating coil through suitable cleaning chemical, washing of filters after cleaning of paint the compact unit of various size of package type AC units of (8.5x2) 17 TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed. .
65Cleaning of out door condenser coil and indoor evaporating coil through suitable cleaning chemical, washing of filters after cleaning of paint the compact unit of various size of package type Chiller AC units of (12x3) 36 TR capacity and applying two coats of synthetic enamel paint including preparation complete all as specified and as directed. .
66S&F in replacement of indoor unit of Split AC suitable for 1.5TR / 2.0 TR Split AC as directed.
67S&F in replacement Starting Capacitor of 80 to 100 MFD complete all as specified and as directed.
68S&F in replacement motor protection device (MPD) suitable for (8.5x2) 17 TR capacity Package type AC complete all as specified and as directed.
69S&F in replacement MCCB, 3 pole , 25 KA, with fixd thermal setting, of capacity 100 Amps complete all as specified and as directed.
70S&F in replacement MCB TPN, 63 Amps, 10 KA, complete all as specified and as directed
71M & Labor for complete servicing / fault finding any type by OEM rep / service engineer incl opening of evaporating/condensing unit of (12x3) 36 TR package type Chiller AC units, (5.5x3)16.5 TR Packaged AC, (5.5x2) 11 TR Packaged AC, 5.5 TR Packaged type AC and (8.5x2) 17 TR Packaged type AC for servicing of condenser motor or for finding out any leakage of refrigerant from suction or discharge line and stop the leakage by gas welding / brazing and again Nitrogen gas charging for 48 Hrs for checking any leakage in line and cleaning of air filter, indoor water storage tray and drain, including any minor parts etc, rectify if any water leakage, refixing, re-assembling the evaporating/condensing unit and making good and re-fixing after repair work is completed, complete all as specified and as directed. (Note: Ref gas if required paid in separate item of BOQ)
72S&F in repairs single/ three phasing preventer suitable for 5.5 TR/ (5.5X2)11 TR/ (5.5x3) 16.5TR/ (8.5x2) 17 TR/ (12x3) 36 TR package type AC units of existing make complete all as specified and as directed.
73S&F in replacement condenser coil made up of copper for split type AC of capacity 1.5 TR/ 2.0 TR complete all as specified and as directed.
74Dismantling of 5 HP monoblock pump set for replacement of bearing/ serving etc complete and refixing the same after repairs complete all as specified and as directed.
75M&L for rewinding of monoblock pump set of 5HP with copper winding coils of same guage as burnt complete and testing the same with rated current complete all as specified and as directed.
76S&F in repairs gas charging valve of suction or discharge line suitable for 5.5 Ton/ 11 Ton/ 16.5/36 TR capacity Packaged / Chiller AC units as per existing make and model complete all as specified and as directed.
77S&F in repairs expansion valve suitable for 5.5Ton/ (5.5X2) 11 Ton/ (5.5x3)16.5 TR capacity AC units (Carrier/voltas/Bluestar) as per existing make and model including cutting, brazing/ welding, leak testing etc complete all as specified and as directed.
78S&F in repairs expansion valve suitable for (8.5X2) 17 Ton capacity AC units (Carrier/voltas/Bluestar) as per existing make and model including cutting, brazing/ welding, leak testing etc complete all as specified and as directed.
79S&F in repairs expansion valve suitable for (12X3) 36 Ton capacity Chiller AC units Bluestar make and model including cutting, brazing/ welding, leak testing etc complete all as specified and as directed.
80M&L for submain wiring with two runs of single core, 1100 Volts grade multistranded copper conductor cable of size 4.0 sqmm, PVC insulated, unsheathed, fire retardant low smoke (FRLS) drawn through and including PVC casing and capping of suitable size with all necessary fittings and one run of single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, fire retardant low smoke (FRLS) as earth wire, fixed on wall/ ceiling complete all as specified and as directed. Note:- Two runs of 4.0 sqmm cable and one run of 2.5 sqmm cable as earth wire and one run of PVC casing and capping with casing/ capping accessories shell be measured as one unit.
81M&L for carefully opening the AC units, taking down defective parts/ accessories (Duct, bearing, Shaft along with blower motor etc.) for repairs after disconnecting electric connections and re-assembling the AC after repairs and re-fixing only serviceable accessories and re-fixing the ACs to its original position including bearings quantity 02 Nos and V belt. and testing complete for 5.5/(2 x 5.5) 11/ (3x5.5) 16.50 Ton capacity package AC complete all as specified and as directed.
82Supply and fix in replacement of three phase DOL starter suitable upto 5/7.5 HP rating complete all as specified and as directed.
83Supply & Fix in replacement of new compressor sealed unit sutiable for existing make and model, including brazing/ welding of suction and discharge line, including first filling gas, replacement of liquid line air dryer and leak testing complete, 8.5 Ton capacity suitable for (8.5X2) 17 TR package AC unit complete all as specified and as directed.
84Taking out, reapir and refix the PCB, outdoor electronic switch suitable for 1.5 / 2 TR split AC Inverter Type complete.
85Taking out, reapir and refix the PCB, indoor electronic switch suitable for 1.5 / 2 TR split AC Inverter Typecomplete.