Military Engineer Services-MES has published Tender For Repair/Maint Of Cooling Appliances Like Split Acs, Water Coolers, Deep Freezer Etc And Comprehensive Maint Of Apfc Panels Including Repair/Maint And Connected Works At Ins Dronacharya,Npol And Sma Rameswaram Under Ge Fort Kochi.. Submission Date for this Tender is 19-08-2023. Air Conditioner Tenders in kochi Kerala. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 21-Jul-2023 | DATE CORRIGENDUM | Date | 07-08-2023 |
2 | 24-Jul-2023 | CORRIGENDUM | Other | 07-08-2023 |
3 | 24-Jul-2023 | BOQ CORRIGENDUM | BOQ | 07-08-2023 |
4 | 07-Aug-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 14-08-2023 |
5 | 14-Aug-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 19-08-2023 |
Sl. No. | Item Description |
1 | AIR CONDITIONING:- S & F factory built hermatically sealed compressor unit suitable for 1.5 Ton capacity split / window type AC, testingthe leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerent gas including taking out old unserviceable compressor from the split type AC complete all as specified and directed |
2 | S&F factory built hermatically sealed compressor unit suitable for 2.0 Ton capacity split type AC, testingthe leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerent gas including taking out old unserviceable compressor from the split type AC complete all as specified and directed |
3 | S & F factory built hermetically sealed compressor unit suitable for 2.5 Ton capacity split type AC, testingthe leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerent gas including taking out old unserviceable compressor from the split type AC complete all as specified and directed. |
4 | M & L repairing the leakingareaand recharging refrigerent R-22 /304 a /407a /134 gas for Window / Split type AC, Water cooler, Refrigerator, Deep freezer etccomplete all as specified. |
5 | M&L on site servicing1.5 / 2.0 / 2.5Ton capacity split / window type AC of any description by cleaning air filter, cooling / condensor coil and outer cabinet with pressurised water and detergent solution, applying new insulation to torn/damaged insulation complete all as specified to the satisfaction of Engr in charge. |
6 | S & F condensor fanmotor with capacitor and mounting materials, single phase, 230 Volts, 50 Hz suitable for 1.0/1.5/2.5Ton capacity split type AC including taking out old unserviceable blower motor complete all as specified. |
7 | S & F in repair thermostatic switchsuitablefor 1.5 / 2.0 / 2.5 Ton capacity split / window type AC complete all as specified. |
8 | S & F in repairoverload relaysuitablefor 1.5 Ton capacity window type AC complete all as specified. |
9 | S & F in repairstarting relaysuitablefor 1.5 /2.0 Ton capacity window type AC complete all as specified. |
10 | S & F in repaircopper condensersuitablefor 1.5 Ton capacity split / window type AC complete all as specified. |
11 | S & F in repaircopper condensersuitablefor 2.0 Ton capacity split type AC complete all as specified. |
12 | S & F in repaircopper condensersuitablefor 2.5 Ton capacity split type AC complete all as specified. |
13 | S & F in repair30 / 36 mfd running capacitorsuitablefor 1.5 / 2.0 / 2.5 Ton capacity split / window type AC complete all as specified. |
14 | S & F in repair PVC fan blade suitablefor 1.5/2.0/2.5 Ton capacity split / window type AC complete all as specified. |
15 | S & F in repairPCB suitablefor 1.5 /2.0 /2.5 Ton capacity split / window type AC complete all as specified. |
16 | S & F in repairliquid strainer suitablefor 1.5 / 2.0 / 2.5 Ton capacity split type AC complete all as specified. |
17 | S & F in repaircapillary tubefor 1.5 / 2.0 / 2.5 Ton capacity split type AC complete all as specified. |
18 | REFRIGERATION S & F factory built hermatically sealed compressor unit suitable for 175 / 205 Ltrs capacity Refrigerator, testingthe leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134 / R-600 Refrigerent gas including taking out old unserviceable compressor from the Refrigerator complete all as specified and directed |
19 | S&F factory built hermatically sealed compressor unit suitable for 285 / 310 / 340 Ltrs capacity Refrigerator, testingthe leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134 / R-600 Refrigerent gas including taking out old unserviceable compressor from the Refrigerator complete all as specified and directed. |
20 | S & F in repairthermostatic switchsuitablefor 175 / 205 / 285 / 290 / 310 / 340 Ltrscapacity Refrigerator complete all as specified. |
21 | S & F in repairstarting relay suitablefor 175 / 205 / 285 / 290 / 310 / 340 Ltrscapacity Refrigerator complete all as specified. |
22 | S & F in repair door switch suitablefor 175 / 205 / 285 / 290 / 310 / 340 Ltrscapacity Refrigerator complete all as specified. |
23 | S & F in repair drier filter of size 1/4" x 1/4"flare connection suitablefor 175 / 205 / 285 / 290 / 310 / 340 Ltrscapacity Refrigerator complete all as specified. |
24 | S & F in repair overload relay suitablefor 175 / 205 / 285 / 290 / 310 / 340 Ltrscapacity Refrigerator complete all as specified. |
25 | S & F in repair electronic fan motor, single phase, 230 Volts, 50 Hzsuitablefor 425 Ltrscapacity Deep freezer complete all as specified. |
26 | S & F in repair thermostatic switch suitablefor 425 Ltrscapacity Deep freezer complete all as specified. |
27 | WATER COOLER:- S&F factory built hermatically sealed compressor unit suitable for 40 / 60 / 80 Ltrs capacity water cooler, testingthe leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134/R-22 Refrigerent gas including taking out old unserviceable compressor from the water cooler complete all as specified and directed |
28 | S&F factory built hermatically sealed compressor unit suitable for 100 / 150 Ltrs capacity water cooler, testingthe leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134 / R-22 Refrigerent gas including taking out old unserviceable compressor from the water cooler complete all as specified and directed |
29 | S & F in repair starting relay assembly suitablefor 40 / 60 / 80 / 120Ltrscapacity water cooler complete all as specified. |
30 | S & F in repair running capacitor suitable for 40 / 60 / 80 / 120Ltrscapacity water cooler complete all as specified. |
31 | S & F in repair overload relay suitablefor 40 / 60 / 80 / 120Ltrscapacity water cooler complete all as specified. |
32 | S & F in repair thermostatic switch suitable for 40 / 60 / 80 / 120Ltrscapacity water cooler complete all as specified. |
33 | S & F in repair 15mm dia brass chromium plated push cock / lifting cock suitablefor 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified. |
34 | S & F in repair 15mm dia PVC high pressure ball valve with polythene float & fly nutsuitablefor 40 / 60 / 80 / 120 Ltrscapacity water cooler complete all as specified. |
35 | S & F in repair condensor fan motor, single phase, 50 Hz, 230 Voltssuitablefor 40 / 60 / 80 / 120 Ltrscapacity water cooler complete all as specified. |
36 | S & F in repair 15mm dia, 450mm long, PVC connection with brass check nuts, complete all as specified. |
37 | S & F in repair liquid strainer suitable for 40 / 60 / 80 / 120Ltrscapacity water cooler complete all as specified. |
38 | S & F in repair capillary tube suitable for 40 / 60 / 80 / 120Ltrscapacity water cooler complete all as specified. |
39 | M & L comprehensive maint of water purifier, electrically operated, Best Water Doctor / Cross Field by servicing parts, attending break down, replacement of parts including checking the equipment by the Service Engineer once in a month complete all as specified & directed.(4 Nos x 11 Months = 44 Jobs) Note :- (i)Replacement of parts will be measured and paid as supply onlyseparately. (ii)The cost of labour and consumables required for replacement of parts shall deem to include in the unit rate quoted by the contractor. |
40 | Supply only D2 Main PCB suitable for water purifier complete all as specified. |
41 | Supply only compressor suitable for water purifier capacity upto 10 ltr complete all as specified. |
42 | Supply only solenoid valve suitable for water purifier complete all as specified. |
43 | Supply only two way valve suitable for water purifier complete all as specified. |
44 | Supply only PF candle (Industrial) suitable for water purifier complete all as specified. |
45 | Supply only PF Bowl & cap suitable for water purifier complete all as specified. |
46 | Supply only compressor relays suitable for water purifier complete all as specified. |
47 | Supply only compressor fan motor suitable for water purifier complete all as specified. |
48 | Supply only thermostat (cooler) suitable for water purifier complete all as specified. |
49 | Supply only thermostat (heater) suitable for water purifier complete all as specified. |
50 | Supply only heating element suitable for water purifier complete all as specified. |
51 | S & F SPN enclosure with two pin and earth plug and socket complete with one MCB, SP, 20 Amps,having breaking capacity 10 kA, dual termination, isolation function with visual indication complete all asspecified. |
52 | S & F in repair 3 core, 2.5 Sqmm copper conductor, PVC insulated sheathed flexible cordcomplete all as specified. |
53 | S & F in repair 3 core, 4.0 Sqmm copper conductor, PVC insulated sheathed flexible cordcomplete all as specified. |
54 | S & F in repair 3 core, 6.0 Sqmm copper conductor, PVC insulated sheathed flexible cordcomplete all as specified. |
55 | S & F in repair industrial plug top suitable for industrial socket complete all as specified. Make : Legrand / Standard / Havells |
56 | S & F in repair SMPS based voltage stabilizer 2 KVA wall mounting type complete incl mounting accessories all as specified. |
57 | S & F in repair SMPS based voltage stabilizer 5 KVA wall mounting type complete incl mounting accessories all as specified. |
58 | S & F in repair 1/4 X 0.61 OD copper pipe including connecting to split type AC and applying insulation complete all as specified. |
59 | S & F in repair 3/8 x 0.61 OD copper pipe including connecting to split type AC and applying insulation complete all as specified. |
60 | S & F in repair 5/8 x 0.61 OD copper pipe including connecting to split type AC and applying insulation complete all as specified. |
61 | S & F in repair 1/2 x 0.61 OD copper pipe including connecting to split type AC and applying insulation complete all as specified. |
62 | Material and labour for comprehensive maintenance of 10 KVA, UPS by servicing of all parts, tightening of all electrical connections, applying petroleum gelly to battery terminals, repair / replacement of battery leads, attending the break down, repair / replacement of any parts except battery and make the UPS functional including preventive maintenance of UPS once in a month complete all as specified and directed. (1 Nos x 11 months = 11 Jobs). |
63 | S & F in repairPCB suitablefor 10 KVA, 3 phase UPS complete all as specified. Make : Aplab |
64 | S & F in repairtransformer unitfor 10 KVA, 3 phase UPS complete all as specified. Make : Aplab |
65 | S & F in repair display unitfor 10 KVA, 3 phase UPS complete all as specified. Make : Aplab |
66 | S & F in repair maint free battery 12 Volt, 42AH in fully charged condition complete all as specified. Make : Exide / Amron. |
67 | S & fix PVC drain pipe one meter long 32mm dia heavy duty with two nos of galvanized adjustable clamps including taking down existing complete all as specified and directed. |
68 | S & fix PVC float valve suitable 15 mm dia assembly andcomprising valve assembly alum rod, PVC ball for water cooler/ desert coolers including taking down existing complete all as specified and directed. Make :- Paryag / Polytuff |
69 | S & fixOverload protector relay 2613 including taking down existing complete all as specified and directed . Make: Techemshah/ Hitachi. |
70 | Opening of Refrigerators freeze of capacity 285/310 ltrs refixing the same after flushing out and removal of blockage brazing, replacement of liquid line filter and recharging the refrigerator with freon-12 refrigerant to obtain the desired cooling ( Temperature) complete including testing all as specified and directed . |
71 | Opening of Refrigerators freeze of capacity 265 ltrs refixing the same after flushing out and removal of blockage brazing, replacement of liquid line filter and recharging the refrigerator with freon-12 refrigerant to obtain the desired cooling ( Temperature) complete including testing all as specified and directed . |
72 | COMPREHENSIVE MAINT OF APFC PANEL: M & L comprehensive maintenance of 20 NosAutomatic Power Factor correction capacitor banks,40 to 340 KVArincluding repair/replacement of defective/un-serviceable parts during maintenance period, attending to breakdown as and when it is occurres,necessary periodical checking twice in a month and testing of capacitor banks as per manufacture"s instruction for smooth and effficient functioning of capacitor panels, installed at various Sub Stations and Power Houses. |
73 | Note :- (i) The Power Factor shouldalways be maintainedmore than 0.95. (ii) if the Power Factor comes below 0.95 upto .09,apenalty of Rs.1000.00 per HT connection will be recoveredfrom the payment. (iii)If KSEB imposes any penalty due to low power factor than 0.9 then double the amount will be recoveredfrom the contractor as penalty for non functioning of panel. (iv) The rate quoted shall be deemed to be included the charge fortaking out defective spares & fixingof new spares and tightening of cables & accessories etc. (v) Cost of spares required for replacing shall be measured and paid separately. (vi) 2 Weeksx 11 Months = 22 Jobs |
74 | Supply only 2 KVAr Capacitor,3 phase,440 VoltAC having low watt loss of not less than 0.5 W/KVAR ,all as directed. |
75 | Supply only 5 KVAr Capacitor,3 phase,440 VoltAC having low watt loss of not less than 0.5 W/KVAR ,all as directed. |
76 | Supply only 7.5 KVAr Capacitor,3 phase,440 VoltAC having low watt loss of not less than 0.5 W/KVAR ,all as directed. |
77 | Supply only 10 KVAr Capacitor,3 phase,440 VoltAC having low watt loss of not less than 0.5 W/KVAR ,all as directed. |
78 | Supply only 12.5 KVAr Capacitor,3 phase,440 VoltAC having low watt loss of not less than 0.5 W/KVAR ,all as directed. |
79 | Supply only 15 KVAr Capacitor,3 phase,440 VoltAC having low watt loss of not less than 0.5 W/KVAR ,all as directed. |
80 | Supply only 20 KVAr Capacitor,3 phase,440 VoltAC having low watt loss of not less than 0.5 W/KVAR ,all as directed. |
81 | Supply only 25 KVAr Capacitor,3 phase,440 VoltAC having low watt loss of not less than 0.5 W/KVAR ,all as directed. |
82 | Supply only 16AmpCapacitor duty contactors ,all as directed.Make : L&T / Siemens / ABB |
83 | Supply only 30 AmpCapacitor duty contactors ,all as directed. Make : L&T / Siemens / ABB |
84 | Supply only 230 VoltControl relay ,all as directed. Make : L&T / Siemens / ABB |
85 | Supply only Microprocessor based APFC relay, 14/12 stage ,all as directed.Make : L&T / Siemens / ABB / Shneider |
86 | Supply only flush head 230 Volt AC PushButton ,all as directed. |
87 | Supply onlyLED type neon indicator lamp (RYB) 230 Volt ,all as directed. |
88 | Supply only LED type three phaseVoltmeter ,all as directed. |
89 | Supply onlyLED type three phase Ampher meter with CTs,all as directed. |
90 | Supply onlyMCB, SP, 6 Amps,having breaking capacity 10 kA, dual termination,isolation function with visual indication complete all asspecified. |
91 | Supply onlyMCB, TP, 63 Amps,having breaking capacity 10 kA, dual termination, isolation function with visual indication complete all asspecified andas directed. |