}

Tender For Repair Maint Of Solar Water Heater/Ceiling Fan/Wall Fan/Geyser In Area Yard Ii Of Age E/M Under Ge (East) Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair Maint Of Solar Water Heater/Ceiling Fan/Wall Fan/Geyser In Area Yard Ii Of Age E/M Under Ge (East) Lucknow. Submission Date for this Tender is 26-07-2023. Solar Heater Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38416436
Corrigendum : Tender For Repair Maint Of Solar Water Heater/Ceiling Fan/Wall Fan/Geyser In Area Yard Ii Of Age E/M Under Ge (East) Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
26-07-2023

Tender Details

Repair Maint Of Solar Water Heater / Ceiling Fan / Wall Fan / Geyser In Area Yard Ii Of Age E / M Under Ge ( East ) Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work:REPAIR MAINT OF SOLAR WATER HEATER/CEILING FAN/WALL FAN/GEYSER IN AREA YARD-II OF AGE E/M UNDER GE (EAST) LUCKNOW
Sl. No. Item Description
1M&L for disconnection of electric supply and water supply pipe line of solar water heater/ collector plates of any size from site for repair/ overhauling/ replacement of unserviceable parts including nut and bolts with washers and refixing the same in serviceable condition after assembling , testing and reconnecting the electrical and water supply line complete all as specified and directed.
2S&F in replacement of heating element 3 KW, suitable for solar water heater (ISI marked) complete all as specified and directed.
3Taking down old tank and supply and fixing of200 LPD hot water tank fully insulated complete all as specified and directed.
4M&L for descaling of pipe line with chemical powder and liquid (4 Kg each) of solar collector plates, solar water heating tankcomplete all as specified and directed.
5M&L for replacement of old unserviceable collector glass panel with heating resistant glass panel of size 2.08 Mtr x 1.01 Mtr of thickness not less than 8 mm including cleaning of broken glass complete all as specified and directed.
6M&L for replacement of old unserviceable collector panel used for solar water heater based on in directed transfer of heat of capacity 100 LPD complete all as specified and directed.
7M&L for welding work of rusted portion of complete set of collector panel including metal/ GI pipe where necessary complete all as specified and directed.
8Taking out old U/S insulated 15mm bore pipe and S&F hot water pipe duly insulated with glass wool and aluminium cladding galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed.
9Taking out old U/S insulated 20mm bore pipe and S&F hot water pipe duly insulated with glass wool and aluminium cladding galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed.
10Taking down the geyser of any size/type/make from site for repairs/overhauling/replacement of unserviceable partsincluding replacement of old nuts and bolts with washers heavy duty includingdisconnection of electric supply, water supply lines and refixing the the geyser in the serviceable condition after assembling, testing and reconnecting the electric/ water supply line complete all as specified and directed. Note:-Replacement of unserviceable parts of old geyser shall be measured and paid separately under respective item here in after except bolt, nuts and washers."
11S&F in replacement of heating element 2.0 KW of geyser (ISI marked) for suitable any type/model/make complete all as specified and directed.
12S&F in replacement thermostat (ISI Marked) suitable for any type, and capacity of geyser complete all as specified and directed.
13S&F in replacement unserviceable indicating lampsred and green colour for suitable any geysers any make complete all as specified and directed.
14Supply and fix in replacement of unserviceable door assembly ISI marked comprising of inlet and outlet thermostate, housing with gasketwith bolts, nuts, washers, screws of packing suitable for any type and make of geyser complete all as specified and directed.
15M&L in repairing of leakage of inner copper/steeltank ofany type /capacity and make of geyser by brazingincluding necessary denting,etc complete all as specified and directed.
16Supply and Fix in replacement of unserviceable plug top 3 pin 15 Amp complete all as specified and directed.
17Supply and fix in replacement ofunserviceable 3 core copper flexible round cable 4 sqmm size complete all as specified and directed.
18S&F in replacement stainless steelinner tank 25 Ltrs capacityas per existing gauge for geysers complete all as specified and directed.
19S&F in replacement stainless steelinner tank 35 to 50 Ltrs capacityas per existing gauge for geyserscomplete all as specified and directed.
20S&F in replacment 450mm long copper connection complete & both side nut with rubber washer suitable for any capacity geysercomplete all as specified and directed.
21S&F in replacment600mm long copper connection with both side nut & rubber washer suitable for any capacity geysercomplete all as specified and directed.
22Taking out old U/S 15mm bore pipe and Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed.
23Taking out old U/S 20mm bore pipe and Supply, laying, jointing & testing galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid in walls through proper clamps complete all as specified and directed.
24S&F in replacment of MCB SP 6 to 32 Amps, 240 Volts, breaking capacity 10 KA "C" curve complete all as specified and directed.
25S&F factory made sheet metal enclosure for MCB one way complete all as specified and directed.
26S&F metallic topsuitable for 20 Amp capacity plug & socket complete all as specified and directed.
27S&F metallic plug base suitable for 20 Amp capacity plug & socket complete all as specified and directed.
28S&F switch socket combination 6 pin 15 Amps multipurpose type complete all as specified and directed.
29M&L painting of outer tank of geyser with applying two coats ofwhite synthetic enamel paint including writting MES No. with black paint complete all as specified and directed.
30S&F in replacement of brass safety valve heavy duty ISI marked of geyser suitable for 15 mm bore of pipecomplete all as specified and directed.
31S&F 450mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of geyser complete all as specified and directed.
32S&F600mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of geyser complete all as specified and directed.
33Taking down ceiling fan/exhaust fan any size any make, sealing cable ends, dismantling blades in case of ceiling fan and removing fan and blades to E/M store yard II for repair & hanging/fixing of the same after repair and connecting up complete all as specified and directed.
34Repair and overhauling of ceiling fan/ exhaust fan/ Cabin fan/ Wall mounting fan/ Table fan/ Pedastal fan of any size by oiling/ greasing and reassembling the fan with new split pin, check nut, locking nut, washer, holder clip & connector. Testing and refixing of same fan shall be made to the entire satisfaction. Note: Repair work will be carried out at MES workshop/at site/ Users Residence as directed. Material required (Ball bearing and Condenser) for replacement of items will be measured and paid separately.
35M&L of ball bearing of size 6201/6202/6203 complete all as specified and directed.
36S&Fcapacitor 2.5 MFdfor ceiling fan of any size and exhaust fan of size 300/230mm cabin fan any sweep complete all as specified and directed.
37S&F capacitor 4 MFd for exhaust fan of size 450 mm/380 mm complete all as specified and directed.
38M&L in replacement of unserviceable fan regulator electronic rotary step type 110 W (Socket in size 2 Module) suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
39M&L in replacement of unserviceable fan regulator electronic rotary step type 110 W (Switch in size 1 Module) suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
40M&L in replacement of unserviceable fan regulator electronic rotary step type 110 W (Socket in size 2 Module) modular typesuitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed.
41Repair of ceiling/ exhaust/ Pedestal/ cabin fan electric line from Switch Board to ceiling rose, replacing minor parts, like Split pin, bolts, nuts, oiling of bearing/bush from out Side etc all as specified and directed. Rewinding of Ceiling/ Exhaust/ Cabin fans and pedestal fans comprising of followings: a) Rewinding of stator with supper enameled copper wire (gauge of wire shall be same as provided by the manufacturer) including varnishing the new winding wire with quick dry varnish properly. b) Replacement of defective worn out bush where required, (ball bearing, capacitor will be measured and paid separately). c) Oiling/greasing and reassembling the fans with new split pin, check nut, locking bolt, washer, holder clip and connector including providing new twisted twin core flexible copper cable of size 23/0.0076 of 1 Mtr length. d) Testing of repaired fan shall be carried out in the yard of AGE E/M (East) to the entire satisfaction.Note: Rewinding shall be carried out in Yard No II,Painting ofFans deemed to be include in respective Item.
42All as above item no 42 but Ceiling fan of 1400 mm Sweep
43All as above item no 42 but Exhaust fan 450 mm (18") to 600 mm (24") Sweep
44All as above item no 42 but Exhaust fan 380 mm (15") Sweep
45All as above item no 42 but Exhaust fan 300 mm (12") Sweep
46All as above item no 42 but Exhaust fan 230 mm (9") Sweep
47All as above item no 42 but Wall fan 400 mm Sweep
48S&F blade set (set of three) for any type/make of ceiling fan 1200 mm Sweep complete all as specified and directed.
49S&F blade set (set of three) for any type/make of ceiling fan 1400 mm Sweep complete all as specified and directed.
50S&F blade Set with frame & four legs of fan with coupling for 450 mm (18") sweep exhaust fan complete all as specified and directed.
51S&F blade Set with frame & four legs of fan with coupling for 380 mm (15") Sweep exhaust fan complete all as specified and directed.
52S&F blade Set with frame & four legs of fan with coupling for 300 mm (12") Sweep exhaust fan complete all as specified and directed.
53S&F blade Set with frame & four legs of fan with coupling for 230 mm (9") Sweep exhaust fan complete all as specified and directed.
54S&F blade set of cabin fan suitable for 400 mm sweep complete all as specified and directed.
55S&F twisted twin core flexible copper cable of size 23/0.076 mm complete all as specified and directed.
56M&L for spray painting of fan with one coat of super enamel white paint after cleaning of body and blades, down rods, with detergent powder and writing MES Nos with black paint complete all as specified and directed.
57M&L in replacement of unserviceable hanging clamp for ceiling fan of any type complete with rubberreel, split pin, bolts, nut and washer complete all as specified and directed.
58M&L in replacement of worn out/defective roter shaft of ceiling fan, exhaust fan, cabin fan of any make and size complete all as specified and directed.
59S&F ofceiling fan canopy set of two complete all as specified and directed.
60M&L for removing, cleaning servicing and reassembling of electric chimney single phase and testing after installation with the entire satisfaction complete all as specified and directed.
61Taking down U/S chimney and S&F of electric chimney single phase 230 Volt including push control, baffle filter, metal blower, min suction power 800 Cum/Hr, black powder coated with min size L-90 cm and S-60cm andall accessories complete all as specified and directed. (Note:- U/S chimney will be handed over to E/M Yard No-2 for BER procedure)
62Taking down U/S ceiling fan/exhaust fan/wall fan of any size/Type/Model and handover MES Store EM Yard-II for BER process complete all specified and directed.
63S&F ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE , Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
64S&F ceiling fans complete with blades, down rods and accessories, 230 V, 1400 mm sweep, min air delivery 210 CFM with service value 6.00 BEE , Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
65S&F exhaust fans single phase 230/240 Volts heavy duty metalic body of size 300 mm sweep 1400 RPM ISI marked,and making connection with twisted copper flexible wire 23/0.076 mm complete all as specified and directed.
66S&F exhaust fans single phase 230/240 Volts heavy duty metalic body of size 380 mm sweep 1400 RPM ISI marked and making connection with twisted copper flexible wire 23/0.076 mm complete all as specified and directed.
67S&F exhaust fans single phase 230/240 Volts heavy duty metalic body of size 450 mm sweep 1400 RPM ISI marked and making connection with twisted copper flexible wire 23/0.076 mm complete all as specified and directed.
68S&F wall fan of 400 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 cum/minwith all accessories complete all as specified and directed.
69S&F PVC air freshner 200 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm complete all as specified and directed.
70S&F PVC air freshner 250 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm complete all as specified and directed.
71S&F in replacement of pressure pump motor single phase 230 volt 50 Hz of capacity 1 HP complete of pressure pump & system including making connection complete all as specified and directed.
72S&F PVC air freshner 300 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm complete all as specified and directed.
73S&F energy saving ceiling fan of 1200 mm sweep of 330-370 RPM, 220-240 volts, AC, 50 Hz, ISI marked with five star rating including hanging with the help of fan hook, down rod up to 04 feet and connecting up with provn of 3 core copper flexible cable of size 1.5 sqmm from ceiling rose to fan complete all as specified and directed.Make : Havells, Model: ES-50 Premium or Usha, Model: Energia Star ISI or Crompton Greaves, Model: Empower 50
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail