Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #38413051

Tender For Repair And Maint And Upkeep Of Water Supply Installation Under Zone C Area At Nda Khadakwasla

Issued by Statutory Bodies & Commissions/Committees · khadakwasla, Maharashtra
Tender Value
45 Lakhs
Estimated cost
Bid Submission
03 Aug 2023
0 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
khadakwasla → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Maint And Upkeep Of Water Supply Installation Under Zone C Area At Nda Khadakwasla

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 12-Jul-2023 CORRG Other 24-Jul-2023
2 24-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 31-Jul-2023
3 31-Jul-2023 CORRG Date 03-Aug-2023

BOQ

Name of Work: REPAIR / MAINT / UPKEEP OFWATER SUPPLY INSTALLATION UNDER ZONE\"C\" AREA AT NDA KHADAKWASLA
Sl. No. Item Description
1Takingdown of existing tarfeltand cement plaster of anydescription and thicknesson rooftopincluding flashing andjunctionof parapetandcleaning existingroof topsurfaceby brooming, wirebrushingincluding removing the debrishout completeall asspecified and directed
2Demolition of roofs, any thickness including plastering & leeping (whether full or part)removal of debris at a distance exc 250m but not exc 500m and depositing where directed
3Demolition Concrete of any description and in any position not otherwise specifically provided for
4M&L for cement concrete Type B0 (1:2:4) (12.5mm graded stone aggregate ) as in roof padding complete all as specified
5M&Lfor20mmthickrenderingon concrete surface on roof in cementplaster1:4finishedevenand fairwithoutusingextracementby using Dr. fixit @3%of wt of cement content completeall as directed. (Note: Water proofing Compound measured and paid seprately)
6Supply only water proofing compoundall as directed
7M&L for cutting grooves in brick / stone wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3
8M&L For preparing plastered surfaces,with approved bituminous primer @100 gms/sqm and applying water proofing treatment on wall,roof,chajja\"s,gabble walls, edges (atany respective height of bldg )etc and stick with non-woven polyster matt modified APP Membrane 3mm thick as reinforcement weighing not less than 3.5 Kg/sqm and applying one coat of aluminium paint on top of the membrane (at any height ) complete all as specified and directed
9M&Lfor providingcementconcrete PCC (1:2:4) type B1 (20mm graded aggregate)as in coping to parapet wall/kerbs in roof with projection of 50mm from the outer surface with a groove of 12 mm x 12mm as drip course in bottom sideincluding necessary form work etc completeall as specified and as directed
10Dismantling of single layer of manglore/ Similar pattern tiles in roofing complete all as directed.
11Dismantling of battens of tiles of any size and description spaced exc 15 cm, including tiling fillets complete all as directed.
12Dismantling of unframed wk timber scantlings 40 sq. cm and over in section, in any position complete all as directed.
13Ditto as per itemNo.12abovein fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section
14Dismantling ofPlain or corrugated steel sheeting, any gauge, thickness, including Nainital orsimilarpattern roof coverings complete all as directed.
15S&F Galvanised corrugated mild steel sheeting 0.63mm thick with two corrugations side lap, fixed with \"L\" type or \"J\" type of cranked hook in lieu ofscrews and washers in roofs, walls etc with grade of zinc coating 275.
16S&F Galvanised plain mild steel sheeting 0.63mm thick in Ridge, hips, valley gutter, drip and straight flashing (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
17S&F pre painted galvalume aluminium zinc coating GI based corrugatedsteel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering /cladding to wall fixed with L hooks or J types or cranked bolts complete all as specified and as directed (i) Work to be executein any respective ht of building
18M&L for wrought 2nd class hard-wood in scantlingsin repairs, to replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) and removing defective portions to store complete all as directed.
19M&L for clean sawn ,2nd class H/W tile battens at 30cm centres, exe 5 and n.exe 15 sqcm sectional area complete all as specified.
20Ditto all as per item No. 19 above but except battens
21M&L for preparing tile battens of any size and spacing andtreated all over (measured overall on one side only spaces not deducted) with two coats of cresoting oil etcspecified and directed
22M&L for providing roof tiles Manglore pattern interlocking at side joints, laid dry (at any height of bldg), complete all as specified.
23Ditto all as per item No. 22 above but except tiles
24M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in CM (1:6).
25Ditto all as item No. 24 above, but except tiles
26S&F in repairs eaves boards clean sawn in roof 20mm thick complete all as specified and directed.
27M&L for preparation of new wooden surfaces and paintingtwo coats of Synthetic Enamel paint over a coat of pink primer.
28Takingupor down 15 mm steeltubing and connections including cleaning for refixing
29Taking up or down 20 mm steeltubingandconnections includingcleaningfor refixing
30M&L for 15mm bore, medium grade, GI tubingwith all fitting and fixed complete to walls and ceilings or laid in floors and cuttingholesn exc 100 sqcm superficial area chase,pinning in making good to facings where required in pointing in cement mortar (1:3) for concealed water tubingcomplete all as specified .
31M&L for 20mm bore, medium grade, GI tubingwith all fitting and fixed complete to walls and ceilings or laid in floors and cuttingholesn exc 100 sqcm superficial area chase,pinning in making good to facings where required in pointing in cement mortar (1:3) for concealed water tubingcomplete all as specified.
32Dismantling of existing water tanks Exc 250 not Exc 500 and removing to store complete all as directed.
33Ditto all as per above item No32above but but exc 500 Ltr n. Exc 1000 Ltr capacity complete all as directed..
34S&F Three layered Rotational moulded polyethylene waterstorage 500 litres tank (cylindrical vertical with closed top) hoisted and fixed in position and Including 20 mm dia stop cock cast copper alloy and 20 mm dia PTMT float valves complete all as specified in SSR part I and as directed
35S&F Three layered Rotational moulded polyethylene waterstorage 1000 litres tank (cylindrical vertical with closed top) hoisted and fixed in position and Including 20 mm dia stop cock cast copper alloy and 20 mm dia PTMT float valves complete all as specified in SSR part I and as directed
36S&F in repair Ball valves 15mm dia high pressure of PTMT with epoxy coated Aluminiumrod& highdensity plastic ball screwed for iron pipe and fixed.(Minimum weight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms)including taking down old one complete all as specified and directed.
37Ditto all as per Item No. 36 above but 20mm dia
38S&F in repairs Bib taps 15mm dia, chromium plated ,fancy type ,cast copper alloy with crutch orbutterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed including taking down old one complete all as specified and directed.
39S&F in repairs Stop valves 15mm dia, chromium plated ,fancy type, cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed including dismantling of old one complete all as specified and directed
40Dismantling floor or wall tiling of any description and size including cement mortar bedding (but not backing), removing rubbish off the premises complete all as directed.
41Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etcincluding cleaning off premises where directed
42Taking down cement plaster on brick or stone walls etc including raking out joints,hacking for key ,scrubbing down with water etc complete all as directed.
43Demolition of unreinforced cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including cleaning off premises where directed
44Takingdownchowkhatsor frame not exc 1.5 sqm eachwithshutters (without taking off shutters from the frames)complete all as directed.
45Takingdownchowkhatsor frame not exc 1.5 sq. m but n exc 4 sq m each withshutters (without taking off shutters from the frames) complete all as directed.
46M&L for Joint free non-skid colouredceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm butnexc 0.18 Sqm (400x400x7 to 8 mm thick) as in flooring etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile laid over& including 15 mm thick screed bed cement mortar (1:6) complete all as spcified..
47M&L for Joint free non-skid colouredceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm butnexc 0.18 Sq (400x400x7 to 8 mm thick) as in skirtingetc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile laidover 10mm thick rendering in CM (1:4) complete all as spcified..
48M&L for coloured Glazed ceramic tiles as in vertical surfaceof Size 350x 250 x7mm /450x350x7 mmset and jointed in neat cement slurry laid over 10 mm thickcement renderingincement mortar 1:4. and pointed in white or colour cement to match the tile complete all as specified.
49M & L for machine cut superior quality Kota stone slab flooring 20-25 mm thick over cement screed , laid and jointedwith grey cement slurry mixed with pigment to match the shade of theslab including rubbing andmirror polishing complete match including bulnosed to edges complete and incl 20 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed
50M&L for removing loose, disturbed or disintegrated old concrete surfaces of RCC beam, column, lintel, pardi, railing etc, cleaning thoroughly exposed reinforcement, by sand blasting using suitable pump as directed by the GE, preparing exposed concrete surfaces to receive guniting, applying one coat of anti corrosive paint to the exposed reinforcement, supply and fix welded wire mesh of size100 x 100 mm of 3 mm dia wire, weight not less than 1.37 Kg/Sqm & binding with 22 guage mild steel (annealed)binding wire to reinforcement and applying pressure guniting in cement mortar (1:3), average 30mm to 50mm thicknessand thereafter rendering 10 mm thick plaster in cement mortar (1:3), mixed with water proofing compound @ 2% by weight of cement and finishing the surfaces even and smooth without using extra cement to match with the existing surfaces, removing the debris outside MD land including material and labour for necessary scaffolding and safety arrangement for guniting work, complete all as specified and directed.(Note :-The finish of the surfaces to be matched with the existing surface.WPC shall be measured & paid separately as supply only).
51M & L for cement concrete (1:3:6) type C2 (Using 20mm graded stone aggregate) in plinth protection, 75 mm thick, finished even and smooth without using extra cement, including making joints 12 mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen85/25and sand inthe proportion of (1:3 ) by weight complete all as spcified.
52S&F 35 mm thick factory made plain framed, panelled shutters with 2nd class hard wood rails and panel of 9mm BWP commercial ply 12mm thick veneered particle board with commercial veneers on both faces.The size of rail or style shall be as per IS 1003 Part-I Kiln seasoned and chemically pressure treated complete all as specified and directed
53S&F 35 mm thick secondclasshardwood factory made glazed and skelton shutters open rebated and prepare to receive glass/ guage (with sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass/guage etc size of member etc size members of shutters as specified in SSR part I Section-8 clauses 8.24(b) supplied and fited to chowkhat made out of 2nd class hard wood, 35mm thick and styles 75mm wide complete .
54S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supply and fixing in opening as per the specification and drawing
55S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails.MS frame shall be covered with hit moulded plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the tiles and rail with suitable PVC sheet bedding and joined together with solvent cement, supplying and fixing in the frame at site as per specificaton & drawing.
56S&F second class hard wood Plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed incl cutting holes and hold fasts fixing (split at one end)
57S&FStainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples , complete all as specified and directed.
58S&F butt hinges cold rolled mild steel 100mm long medium weight complete all as specified and directed.
59S&F extruded anodised aluminumalloy handle 125mm long fabricated type .complete all as specified and directed.
60S&F anodised aluminum barrel tower bolt of extruded section 150mm long. complete all as specified and directed.
61S&F aluminum alloy sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheets, cast of exctruded sections and fixing bolts of extruded section and all as specified complete all as specified and directed.
62S&F 100mm Aluminium handles, cast type, anodised complete all as specified and directed.
63S&F75mm butt hingescold rolled mild steel medium weight and fixed complete all as specified and directed.
64S&FAluminium anodised barrel tower bolts of extruded section 75mm long complete all as specified and directed.
65S &F 30 mm thick Flush shutters ,solid core construction , with particle board core and plywood face panels , commercial type on both sides complete all as specified and directed.
66M&L for second class hard wood glazed and skeleton shutter 30mm thick, factory made, open rebated and prepared to receive glass/gauge etc, sash bars, mitred and rebated, with edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, sizes of stiles, rails etc as specified in section 8, clause 8.24 (b) of SSR part-I(2009)complete all as specified and directed.
67M&L for preparation of new or previously untreated wooden surfaces of any description ,not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
68M&L for 15 mm thick cement plaster on brick or concrete surface in cement mortar1:6 included finishing surface even and smooth without using extra cement onwalls etccomplete all as specified and directed.
69M&L for 10mm thick cement plaster on concrete surface in cement mortar (1:3) included finishing surface even and smooth without using extra cement on ceiling etc complete all as specified and directed
70M&L for 15 mm thick cement plaster on brick or concrete surface in cement mortar1:4 included finishing surface even and smooth without using extra cement onwalls etc complete all as specified and directed
71M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over one coat of alkali registant priming paint using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.
72Ditto all as per item No 71above here-in-before but in ceiling etc complete all as specified and as directed.
73M&L for preparation of newly plastered surfaces of wall and applying twocoats of cement base paint white or tinted including scaffolding arrangement, trestles, ladders etc complete all as specified and directed.
74Demolition of brick / block masonry/ Stone masonry built in Cement mortar complete all as specified and directed.
75M&L for precast cement concrete (1:3:6) type C-1 ( using 20mm graded aggregate ) block masonry with solid blocks exc10 cm thick in width and setting in cement mortar 1:6 complete in wallcomplete all as specified.
76M&L for Walling of squared rubble, regular coursed, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed.
77M&L for flush pointing to random or polygonal rubble, uncoursed on brought upto courses in cement mortar (1:4) complete all as specified and directed.
78Raking out joints/pointing to squared rubble masonry, coursed or uncoursed built in cement mortar complete all as specified and directed.
79M & L for75 mm thick cement concrete (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in floor etccomplete all as specified
80M&L for glossy finish machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment to match complete, all as specified and directed
81M&L for sand layer under floor of interlocking paver tiles incl watering and consolidation complete all as specified and directed.
82M&L forglossy finishChequered cement concrete tiles 30 cm x 30 cm x 25mm thick, set, jointed and pointed in neat cemeant slurry in floors with grey cement and pigment in floor over 20mm screed bed in cement mortar (1:6) complete all as specified and directed.
83M&L for 100 mm thick cement concrete (1:2:4),type B-1 (Using 20 mm graded crushed stone aggregate) as in hard standing completeall as specified and directed.
84M&Lforforming expansion joints 100 mmdeep x 12 mm wide filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade A.
85M&Lfor preparation of old painted surfaces of wall by completely removing existingtreatment by scrapping , cleaning , washingwith water etc , and applying Two coats of oil bond distemberincluding filing the surface with crack filler wherever required complete all as specified and directed. Note :- (i) The coulour scheme of the painting will be as decided by the accepting officer(ii) work tobe execute under occupation conditions.
86M&Lfor preparation of old painted surfaces of ceiling by completely removing existingtreatment by scrapping , cleaning , washingwith water etc , and applying Two coats of oil bond distemberincluding filing the surface with crack filler wherever required complete all as specified and directed . Note :- (i) work tobe execute under occupation conditions.
87M&l for injection grouting in concrete wall in lift wells using Dr Fixit Epoxy Injection Grout all as per manufactires instruction and specification complete all as specified and directed.
88Preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified
89Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion by demolation of cement concrete or any type of work complete all as specified.
90S & F for angle ironas in posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire etc. including all necessary drilling, bolting or riveting etc. conforming to Fe 290 Gde E-165, in rapair complete all as specified and directed
91M&L for cement concrete (1:4:8), type D-2 (Using 40mm graded stone aggregate) as in foundations, filling and mass concrete.
92Dismantling security fencing wire any type (babed wire, chain link fencing, GI mesh etc) complete all as specified and directed
93Supply onlyChain link MS galvanised fencing conforming to IS 2721: 2003 including line wires of 3.15mm dia straining bolts, etc including provision of binding wire
94Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire
95S&F Mild steel screw or bolts (machine made) with hexoganal or square heads at one and screwed the other, or screwed both ends each screwed end to be filled with washers and hexogonal or square nut ,not exceeding5cm long and diameter of neck 5 to 10mm complete all as specified and directed.
96S&F mild steel straps including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 conforming to FE-290 Gde- 165 ,complete all as specified.
97M&L formild steel bars 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for columns hooking ends and binding with and including mild steel wire annealed not less tan 0.9 mm dia or securing with clips quality conforming to round barsconfirming Fe-410-W(Gde.E-250), complete all as specified and as directed
98S&F in repairs Stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and directed.
99Hacking out old broken glass(any thickness, size, quality or discription) from wooden frames or stone, concrete or brick surrounds , glazed with puttyor fixed with beads complete all as specified and directed.
100S&FSheet glass 3 mm thick ordinary quality and glazing with oil putty incl wooden beads supply & fixing in square n exc 0.5 sqm in each pane complete all as specified and directed.
101S &F in repairs Steel rolling shutters, 1.25 mm thickness of lath, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer;erected in position as indicated,complete: push pull or manual type complete all as specified and directed.
102M&L preperation of old/new steel surfaces over 10 cm in width or girth not otherwise described and applying 2 coats of synthetic enamel paint over a coat of red oxide primer.

AI Tender Summary

OUR REF NO 38413051
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 03-08-2023
Authority
Authority Name Military Engineer Services
Work Description Repair And Maint And Upkeep Of Water Supply Installation Under Zone C Area At Nda Khadakwasla
Basic Detail
Tender No 8737/E8
Bidding Type Tender
Location
City khadakwasla
State Maharashtra
Key Dates
Publish Date 31 Jul 2023
Submission Date 03 Aug 2023
Open Date 05 Aug 2023
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Not Available
Document List
1359c93b-ad91-4a2e-98c8-dec0a42c08e7.html
BOQ_679271.xls
NIT.pdf
TENDER.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 31, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 24, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 31, 2023
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 03, 2023
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Aug 03, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 05, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

1359c93b-ad91-4a2e-98c8-dec0a42c08e7.html

xls

BOQ_679271.xls

pdf

NIT.pdf

pdf

TENDER.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders