Supply Of Different Type New Abb Make Ac Vfd With Installation And Commissioning For Season 2023-24 , Supply Of Different Type New Abb Make Ac Vfd With Installation & Commissioning , A. Vfd Panel 160Kw Heavy Duty Application- Injection Pump, Make- Abb , Series, Model- Acs580-01-363A-4+J425, With Complete Panel As Per Attached Specificationsinstallation & Commissioning Of Panel Including Automatic Control Of Rpm According To The Injection Header Pressure. 1. Main Incomer - I. Mccb Microprocessor Based - 01 No., Ii. Semiconductor Fuse- 03 Nos. Iii. Hrc Fuse 2A With Base- 03 Nos., Iv. Phase Indication 230Vac- 01 No., V. Voltmeter 0 - 500V Ac- 01 No., Vi. Voltage Selector Switch- 01 No., Vii. Door Limit Switch- 01 No., Viii. Panel Lamp- 01 No., Ix. Thermostate- 01 No., X. Space Heater - 01 No., Xi. Mcb 10A, Dp For Control- 02 Nos., Xii. Control Transformer 500Va, 415V / 0..240V Ac- 01 No., Xiii. Vfd180 Kw Heavy Duty- 01 No., Xiv. Aux. Contactor- 06 Nos., Xv. Ready / Run / Trip- 03 Nos., Xvi. Start / Stop / Speed Inc. / Decpush Button- 04 Nos., Xvii. Local / Remote Switch- 01 No., Xviii. Emg. Stop Pb- 01 No., Xix. Signal Isolator Duel Channel- 02 Nos., Xx. Signal Isolator Single Channel- 01 No., Xxi. Control Terminal- 50 Nos.B. Plc System For Close Loop Control Of Injection Header Pressure ( 8Ai, 8Ao, 8Di, 8Do Eth , Rs485 Modbus ) , Including Pressure Transmitter ( 0 To 40 Kg / Cm2 ) With All Accessories Including 7 Inch Touch Panel, Complete Erection Work Of Instrumentation And Electrical Shall Be In Vendor Scope. - 01Setc. Power Terminal- 01 No. D. Panelling- I. Panel 800X2000x600- 01 No., Ii. Wiring & Accessories- 01 No., Iii.Busbar Cu- 01 No. E. Remote Control Station- I. Start / Stop Push Button- 01 No., Ii. Speed Increase / Decrease Push Button- 01 No., Iii. Rpm Meter0-1500Rpm, Input 0-10V - 01 No., Vi. Ready / Run / Trip Indication- 01 No., V. Reset Pb - 02 Nos. , A. Vfd Panel 132Kw Heavy Duty Application- Mill Trrpf, Make- Abb , Series Model-Acs580-01-293A-4+J425 With Complete Panel As Per Attached Specifications Installation & Commissioning Of Panel Including Automatic Control Of Rpm According To The Load And Complete Interlocking With Inter Rack Carriers &Mill Complete System Should Be Communicate With Existing Acfc Plc System Shall Be In Vendor Scope As Required. 1. Main Incomer - I. Mccb Microprocessor Based 315A- 01 No., Ii. Semiconductor Fuse 315A- 03 Nos. Iii. Hrc Fuse 2A With Base- 03 Nos., Iv. Phase Indication 230Vac- 01 No., V. Voltmeter 0 - 500V Ac- 01 No., Vi. Voltage Selector Switch- 01 No., Vii. Door Limit Switch- 01 No., Viii. Panel Lamp- 01 No., Ix. Thermostate- 01 No., X. Space Heater - 01 No., Xi. Mcb 10A, Dp For Control- 02 Nos., Xii. Control Transformer 500Va, 415V / 0..240V Ac- 01 No., Xiii. Vfd132 Kw Heavy Duty- 01 No., Xiv. Aux. Contactor- 06 Nos., Xv. Ready / Run / Trip- 03 Nos., Xvi. Start / Stop / Speed Inc. / Decpush Button- 04 Nos., Xvii. Local / Remote Switch- 01 No., Xviii. Emg. Stop Pb- 01 No., Xix. Signal Isolator Duel Channel- 02 Nos., Xx. Signal Isolator Single Channel- 01 No., Xxi. Control Terminal- 50 Nos. B. Plc System For Close Loop Control With Load Of Trpf And Mill, Interlocking With Trpf & Mill ( 8Ai, 8Ao, 8Di, 8Do Eth , Rs485 Modbus ) , This New Plc System Shall Be Communicate With Exiting Plc System, Including 7 Inch Touch Panel, Complete Programming Modification If Required Of Existing System Shall Be In Vendor Scope.C. Power Terminal- 03 Nos. D. Remote Control Station- I. Start / Stop Push Button- 01 No., Ii. Speed Increase / Decrease Push Button- 01 No., Iii. Rpm Meter0-1500Rpm, Input 0-10V - 01 No., Vi. Ready / Run / Trip Indication- 01 No., V. Reset Pb - 02 Nos.E. Panelling- I. Panel 800X2000x600- 01 No., Ii. Wiring & Accessories- 01 No., Iii.Busbar Cu- 01 No , A. Ac Drive Panel 500Kw Application- Mill , Make- Abb , Series- Acs880-04-880A-3+D150-With Complete Panel As Per Attached Specifications Installation & Commissioning Of Panel Including Automatic Control Of Rpm According To The Load And Complete Interlocking With Inter Rack Carriers &Mill Complete System Should Be Communicate With Existing Acfc Plc System Shall Be In Vendor Scope As Required. 1. Main Incomer - I. Acb 1500A- 01 No., Ii. Type, F1 Size 2A Hrc Fuse- 05 Nos., Iii. Red Indication 240V Ac- 01 No., Iv. Yellow Indication 240V Ac- 01 No., V. Blue Indication 240V Ac- 01 No., Vi. Ct Wound Tape 15Va Cl-1 - 03 Nos., Vii. Ct Shorting Link- 03 Nos., Viii. Ammeter 0-200A- 01 No., Ix. Voltmeter 0-500Vac- 01 No., X. Ammeter Selector Switch- 01 No., Xi. Voltage Selector Switch- 01 No., Xii. Transformer 415 / 200Vac 500Va- 01 No., Xiii. Bs Type F1 Size 6A Hrc Fuse- 02 Nos., Xiv. Mcb 6A Dp- 04 Nos., Xv. Mcb 6A Sp- 02 Nos., Xvi. 15A 220 / 250V Thermostat- 01 No., Xvii. 100W / 230V- 01 No., Xviii. Netural Link- 01 No., Xix. Switch Socket Comb With Box 20A- 01 No., Xx. 230Vac Tublight 5W- 01 No., Xxi. Door Limit Switch- 01 No., B. Plc System For Close Loop Control With Load Of Trpf And Mill, Interlocking With Trpf & Mill ( 8Ai, 8Ao, 8Di, 8Do Eth , Rs485 Modbus ) , This New Plc System Shall Be Communicate With Exiting Plc System, Including 7 Inch Touch Panel, Complete Programming Modification If Required Of Existing System Shall Be In Vendor Scope.E. 1. Ac Drive- I. Ac Drive 880A- 01 No., Ii. Contactor 400A, Ac-1 Duty, 230V 50Hz- 01 No., Iii. Mpcb 2.5……….4.0A- 01 No., Iv. Contact Block Aux, Size, 1No1nc- 02 Nos., V. Mpcb 6.3......10A- 01 No., Vi. Drive Run / Fault Indication- 02 Nos., Vii. Ammeter 0-200A, Input 0-10V For Armature Current- 01 No., Viii. Rpm Meter 0-15Rpm, Inpt 0-10V- 01 No., Ix. Digital 500V Dc Voltmeter 96X96mm, Aux. Supply 230Vac- 01 No., F. Remote Control Station- I. Start / Stop Push Button- 01 No., Ii. Speed Increase / Decrease Push Button- 01 No., Iii. Rpm Meter0-1500Rpm, Input 0-10V - 01 No., Vi. Ready / Run / Trip Indication- 01 No., V. Reset Pb - 02 Nos.G. Panelling- I. Panel 1000Wx1690hx800d- 01 No., Ii. Local Control Station- 01 No., Iii. Wiring- 01 No., Iv. Busbar Cu- 01 No. H. Local Control Station- I. Start / Stop Push Botton- 01 No., Ii. Speed Increase / Decrease Push Botton- 01 No., Ii. Rpm Meter 0-1500Rpm, Input 0-10V- 01 No., Iii. Ready / Run / Trip Indication - 01 No., Iv. Reset Pb- 02 Nos., I. Control Terminal- 01 No.