Tender For Repair Of Compound Wall Gate Fencing Area Drainage Culvert Retaining Wall And Misc Wok In D2 And D3 Area At Zone A Area At Nda Khadakwasla
Tender Overview
Project Description
Repair Of Compound Wall Gate Fencing Area Drainage Culvert Retaining Wall And Misc Wok In D2 And D3 Area At Zone A Area At Nda Khadakwasla
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 12-Jul-2023 | REVISED BOQ AND AMDT TO TENDER DOCUMENT | BOQ | 21-Jul-2023 |
| 2 | 21-Jul-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Jul-2023 |
BOQ
| Sl. No. | Item Description |
| 1 | Dismantlingposts or struts (steel or RCC) embedded in concrete, any section, including taking out embedded portion and making good the disturbed surface. |
| 2 | Supply only MS Galvanised chain link fencing, 3 mm nominal dia of wire, avg area of apperture 0.25 sqcm and/or weight of the fencing not less than 2.00 kg/sqm complete all as specified and diretced. |
| 3 | Fixing only MS galvanised chain link fencing, incl line wires any mesh, size and type to any type of standards, rails, straining bolts etc..including provision of binding wire complete all as specified and diretced. |
| 4 | M&L for 10 mm and above dia MS round bars cut to length bent to shape required etc..(to be used for stiffness to chain link) fixed indepdentlyto theangle iron post as directed by Engr-In-Charge. (Conforming to Fe 410w (Gde E-250) quality \"A\" or Fe 290 (Gde E-125).complete all as specified and diretced. |
| 5 | S&F MS screw bolts (machine made 12 mm dia. Shank) with hexagonal or square heads at one end and screwed at another end, each screwed end to be fitted with washer and one hexagonal or square nut, exc. 5cm n. exc 10 cm in length. complete all as specified and diretced. |
| 6 | Supply, fabricate and fixing in position angle iron posts for fencing postsand struts,split at bottom, cut to shape, including providing flat ironfor securing wire mesh with necessary welding, drilling bolting or rivetting, complete all as spd and directed.(Steel confirming to Fe-290 (Gde E-165)) complete all as specified and directed |
| 7 | Fixing onlyin position angle iron posts for fencing postsand struts,split at bottom, cut to shape, including providing flat ironfor securing wire mesh with necessary welding, drilling bolting or rivetting, complete all as specified and directed.Note: angle iron obtained from dimantling shall be used under this item |
| 8 | Dismantling security fencing wire any type (barbed wire, chain link fencing, GI mesh etc) complete all as specified and directed |
| 9 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 10 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar |
| 11 | M&L for lowering & laying in trench of Reinforced Cement Concrete pipes of 300mm bore,class NP3,spigot and socket ended pipes (IS : 458-2003 marked) with and including rollon rubber ring gasket (Conforming to IS : 5382-1967 Type -I, aligning & jointing complete all as specifiedand directed |
| 12 | M&L for lowering & laying in trench of Reinforced Cement Concrete pipes of 450mm bore,class NP3,spigot and socket ended pipes (IS : 458-2003 marked) with and including rollon rubber ring gasket (Conforming to IS : 5382-1967 Type -I, aligning & jointing complete all as specifiedand directed |
| 13 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 14 | Demolition of Precast cement concrete block/stone boulder walling built in CM or Cement lime Mortar omplete all as specified and directed. |
| 15 | M&L for walling of random rubble stone masonry uncoursed well bounded badded and solidly hearted built in CM (1:6) brought upto coursed complete all as specified and directed |
| 16 | M&L for precast cement concrete block masonry exc. 10 cm width with solid blockC5 Grade and settingin cement mortar (1:6) complete all as specified and as directed |
| 17 | M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, builtin CM (1:6) complete all as specified & directed |
| 18 | M&L forprecast cement concrete block (Except block) masonry exc. 10 cm width with solid blockC5 Grade and settingin cement mortar (1:6)complete all as specified and as directedNote: PCC blocks obtained from item no. 14 shall be used. |
| 19 | M&L for brickwork with fly ash bricks (Except brick), straight or curved on plan exc 6m mean radius, builtin CM (1:6)complete all as specified & directed Note: Bricks obtained from item no. 14 shall be used. |
| 20 | M&L for PCC (1:2:4) type B-0 (Using 12.5 mm graded stone aggregate)in coping, hold fast block including weathering slightly rounded and chamferred angleincluding necessary form workand finish of exposed surfaces of concrete as described in SSR Part-II) complete all as specified and directed. |
| 21 | Rakingor cutting out Joints and decayed mortor etc ,washing the joints and keeping the surface to be pointed wet for 2days prior to re-pointingin random rubble or polygonal rubble uncoursed or brought up to courses work built in cement mortor etc upto three storyed bldg or20m height complete all as directed. |
| 22 | M&L for keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in CM (1:4) upto and incl height 20m. CompleteNote : Rates all asincluded for scafollding, shuttering, ladder etc complete all as specified and diretced. |
| 23 | Taking down cement plaster of any description incl racking out joints hacking for key and scrubbing down with water to remove dust etc complete all as specified and diretced. |
| 24 | M&L for rendering 15mm thick cement plaster in CM( 1:4)on block/stone walling surface finished even and smooth without using extra cement complete all as specified and directed. |
| 25 | M&L for cement concrete Type C-2, (1:5:10)(using 40 mm size graded stone aggregate) as in foundation,Mass concretingfilling and mass concrete complete all as specified and directed |
| 26 | M&L for cement concrete Type C-2, (1:3:6)(using 40 mm graded stone aggregate) as in foundation, Mass concretingfilling and mass concrete complete all as specified and directed |
| 27 | Dismantiling timber 40 Sq.cm and over in section (unframed work), in any position complete all as specified and directed. |
| 28 | S&F framed workornamental and intricate design such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 GdeE-165 including removing old structure complete all as specified and diretced. |
| 29 | S&F portions framed & hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; tubular steel, barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks & similar work conforming to Fe 290-0 Gde E-165 including removing old structure complete all as specified and diretced. |
| 30 | M&L for running Welding in repairs and to make in original position of article in anylength and thick of weld n exc 6 mm for purline, rafter, gate, chainlink fencing ,fencing post , MS door,collapsible gate,rolling shutter and misc MS Items (Height of bldg G+3) complete all as specified and directed. |
| 31 | M&L for taking down /dismantling and erection /resecuringin origional position of steel gate after repair of opening n.exc 7 mtr any weight incl welding of any parts new/old, welding of pintal hinges, providing new pintal hinges ,aldrop,handle where ever reqd, fixing of pintal hinges with RCC column/wall complete all as specified and directed. |
| 32 | Servicing and repairs to exsisting rolling shutters at and at all heights above floor level of sizes mentioned below comprising of removing the exsisting hood cover, rectifying damages, removing all shafts along with bearings, springs, gears etc. reconditioning/ adjusting the tension of springs, rectifying damages, if any, to laths, grills flats, bottom plates guide channels, locking arrangements, handles including providing end clips and pins, welding where required reassambling the shutter, refixing the same in original position. Luberating all moving parts ,the new spare part shall be measure and paid separately, operating and commissioning the shutters to the entire satisfaction of the Engr-in-Charge. Note Rate includes taking down and refixing of rolling shutter in same or other opening |
| 33 | M&L for Dubbing out average 15mm thick on irregular face of walls (when specificially ordered in writing) in CM (1:4) complete all as specified and directed. |
| 34 | M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregates as in surface channels and drains complete all as specified and directed |
| 35 | M&L for preparation of newly plastered/ concrete wall surface and applying two coats of cement base paintover a coat of primer complete all as specified and directed |
| 36 | M&L for preparation of old plastered/concrete wall surface and applying one coat of cement base paint complete all as specified and directed. |
| 37 | M&L for preparation of new surfaces and applying two coat of exterior emulsion paint Weather Proof over a coat of primer complete all as specified and as directed. |
| 38 | Rakingor cutting out Joints and decayed mortor etc ,washing the joints and keeping the surface to be pointed wet for 2 days prior to re-pointingin random rubble or polygonal rubble uncoursed or brought up to courses work built in cement mortor etc upto three storyed bldg or20m height complete all as directed. |
| 39 | M&L for keyed pointing to random or polygonal rubble, uncoursed or brought upto courses in CM (1:4) upto and incl height 20m. Complete all as specified and directed.Note : Rates all asincluded for scafollding, shuttering, ladder etc |
| 40 | M&L for raised pointing to random or polygonal rubble, uncoursed or brought upto courses in CM (1:4) upto and incl height 20m. Complete all as specified and directedNote : Rates all asincluded for scafollding, shuttering, ladder etc |
| 41 | M&L preparation of new steel/iron /angle Iron surface of any description over 10 cm in width or girth and applying two coats of synthetic enamel paintover redoxide primer complete all as specified and directed. |
| 42 | M&L preparation of old steel/iron /angle Iron surface of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 43 | M&L for preparation of new/Old untreated concrete surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as speicifed and directed. |
| 44 | Dismantling of stone slabs,cudappah, of any description or thickness in floor/fixed to walls, apron etc laid bedded and pointed in cement mortar complete all as specified and directed |
| 45 | M&L for Fire stone wall tilein exterior surface on verticle surfaces of approved pattern of size 600x300x10mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including10mm thick plaster in C:M (1:4)as a backing coat complete all as specified and as directed. Make : Cart part- Fire stone Nutural of make Kajaria or equivalent in other makes as approved. |
| 46 | M&L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished)in steps, jambs, pillars, window-cills, cooking platforms and like over 10 mm thk cement screed in CM (1:4)) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including grinding and polishing complete all as specified and directed. |
| 47 | M&L for providing edge moulding with semi ciruler shape to 18-20mm thick granite stone of counters vanities etc. including machine polishing to edge to give high glossY finish etc. complete all as specified and directed. |
| 48 | M&L for 20mm thick Granite (of any type) tiles (Except stone/tile) machine cut, in skirting/ dado laid over10 mm thick cement screed in CM (1:4) and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishingcomplete all as specified and directed.Note: Granite stone obtained from item no.44 shall be used under this item |
| 49 | S&F for 110 mm dia PVC SWR pipes single socketed in any length with rubber ring joints fixed to floor including clamp and weep hole etccomplete including taking down of existing u/s pipe all as specified and directed. |
| 50 | S&F 110mm dia PVC (SWR) junction single(single T) completeall as specified and directed |
| 51 | S&F110mm dia PVC (SWR) bends any radiuscompleteall as specified and directed |
| 52 | Dismantling of cast iron 100 mm bore pipes jointed in cement motar including all fittingscomplete all as specified and directed. |
| 53 | M&L for providing cast iron soil & waste and vent spun pipes inany length with or without ears with cement joints fixed to walls using pipes 100mmbore pipescomplete all as specified and directed. |
| 54 | S&F CIbend 100 mm bore with oval access doorcomplete all as specified and directed. |
| 55 | Taking down up or down steel tubing and connections incl cleaning for re-fixing or removal to stores ,15mm dia pipes. complete all as specified and directed. |
| 56 | All as per item No.55 above but 20mm dia pipes |
| 57 | Refixing old steel tubing and conection in new or old position on wall, ceiling, floor etc..15 mm bore pipecomplete all as specified and directed. |
| 58 | Refixing old steel tubing and conection in new or old position on wall, ceiling, floor etc.. 20 mm bore pipecomplete all as specified and directed. |
| 59 | M&L forwriting letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high on concrete surface with synthatic enamal paint and witdth of each letter not less than 1.5 cm Note:- Letters etc., shall be painted with thick paint, so thatthey stand outboldly and solidlywithout showing signs of brush marks, if necessary, they shall berepainted until the desired resultis obtained. complete all as specified and directed. |
| 60 | S&F in repairof 3mm thick Aluminium composite panel (ACP) board of size 4\" x 5\" (n.exc 20 sqft) fixed on both sides( board shall be rectangular or pentagular shape).ACP board to be fixed on grid frame work with SS screws/rivets, made of 20mm stainless steel square tube of 1.25 mm thick of SS 304 series and fixed on the perimeter of 40 mm dia stainless steel tube of 2mm thick of SS - 304 series. A20 mmtube of 1.25mm thick of SSseries 304 of 05 nos and50mm long support to be provided to fix to 40mm thick frame. A grid frame to be provided in side 40mm thick frame of size 20mm square of 1.25mm thick not exe 600mm centre to centre on both ways to support the ACP boards.The board shall be sheated with high intensity retro reflective sheet of blue colour, computerised designed writting letter/figures in (Block, Roman, Italic style or in Indian languages where required) / index hands (natural size)/arrows/ stops/ commas /short lines/dashes/hyphens/ bracket, holograms etc where necessary shall be made high intensity reflective sheet within white colour letter, shape and sizes as required and approved by GE. Letters not exc 200 nos on each face of the ACP Board.Each face to have a border line of 25mm wide with white colour high intensity retro reflective sheet/tape. The sign board to be supported on 2 Nos postof 60mm dia and 2.5mm to 3.0mmthick stainless steelpipe of SS - 304 series, exc 3m and notexceeding4m in height with round moulded design cap on top. Pipes of the boardsto be fixed in ground with PCC 1:2:4 type B2 (using 40mm graded stone aggregate) in post holes of sizes45cmx45cmx75cm depth (post holes and concrete includes in the rates) all as specified and directed by GE. |
| 61 | M&L in replacement ofprecast cement concrete louvres and jallies, 40 mm thick(mea suredsolid), including all mould- ingsbut excluding frame type B0 (1:2:4) (12.5 mm size graded stone aggregate) set in CM (1:4) complete all as specified and directed |
| 62 | S & F as in repairs galvanized 2 strand steel barbed wire 2.24 diabarbed with 2mm dia barbed 75 mm spacing and straining and fixingto any type of standard rails strain-ing bolts including securingof tying at crossing with and provision of mild steel wire staples orsteel pins etc complete all as directed (Each line of wire shallbe measured separately) |
| 63 | Restraining and resecuring to existingbarbed wire fencing including making good staples etc as directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender