|
| 1 | Demolition Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed. |
| 2 | M&L Cement Concrete 1:4:8 (40mm Graded Stone Aggregate) 100mm thick in Sub-bases, complete all as specified and as directed. |
| 3 | M&L for Cement concrete 1:2:4 type D2 as in foundations, filling and mass concrete, complete all as specified and as directed. |
| 4 | M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade,with grey cement & no pigment, incl taking out and removing debris from outside MD land, complete all as specified. |
| 5 | M&Lsand filling under floors or in foundation incl watering and consolidation. |
| 6 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 7 | Taking down Cement Plaster including raking out Joints, hacking for Key, scrubbing down with Water and removing Debris, etc. to Outside MD/AF Land, complete all as specified and as directed. |
| 8 | M&L Rendering (External) 15mm thick in Cement Mortar 1:4 on Brick Walls/Concrete Surfaces mixing with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed.NOTE : WPC shall be Measured and Paid for as ‘Supply only’ separately under appropriate Item. |
| 9 | Supply only Integral Water Proofing Compound, conforming to IS and/or as approved, complete all as specified. |
| 10 | M&L Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the ratio 1:1:1 shall be applied and finish Even, complete all as specified and as directed. |
| 11 | M&L preparing New Plastered Surfaces of Walls by applying Two Coats of Weather Coat Exterior Paint (in Camuflage/Plain pattern as ordered) with approved Tint over a coat of Primer (as per Manufacturer\"s instructions), complete all as specified and as directed. |
| 12 | M&L preparing New Rough Cast Plastered Surfaces of Walls by applying Two Coats of Weather Coat Exterior Paint (in Camouflage/Plain pattern as ordered) with approved Tint as per manufacturer\"s instructions over a coat of primer, complete all as specified and as directed. |
| 13 | Dismantling ofWallandceilingboards(fibre, pulp, insulation, etc.) or insulationboards/slabs/ blankets, any thickness, including cover fillets, snap grid etc complete all as specified and as as directed. |
| 14 | S&F for6mm thick Asbestos cement plain building boards, fixed to wall, including 3mm thick wall care puttycomplete all as specified and as directed. |
| 15 | S&F GI Powder Coated Snap Grid Frame Work of size 600x600mm for False Ceiling with Supported and Hanging of Mild Steel Rod of ‘J’ Bolt including Provision for ceiling Board 12mm thick in Ceiling, fixed on Snap Grid, complete all as specified and as directed.Note: Ceiling board will measured and paid seprately under appropriate item. |
| 16 | Fixing only GI Powder Coated Snap Grid Frame Work of size 600x600mm for False Ceiling with Supported and Hanging of Mild Steel Rod of ‘J’ Bolt including Provision for ceiling Board 12mm thick in Ceiling, fixed on Snap Grid, complete all as specified and as directed.Note: Serviceable qty recd from item No. 13 may be used under this item. |
| 17 | S&F 12mm thick mineral fibre core ceiling board/tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with GI Snap Grid Frame Work with Steel Screws, complete all as specified and as directed. |
| 18 | ditto but except ceilling board complete all as directed by Engr-in-Charge.Note: Serviceable qty recd from item No. 13 may be used under this item. |
| 19 | Dismantling Floor, Paver Tiles, Hearth or Wall Tiling,etc. including Cement Mortar Bedding (but not backing) and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed. |
| 20 | M&L Vitirified Coloured Tiles 9 to 10mm thick (Square/ Rectangular), Double Charge, Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Tiles, laid over and including 15mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 21 | M&L Vtirified Coloured Tiles 9 to 10mm thick (Square/ Rectangular) Double Charge, Light shade, Polished, area of each Tile not exc. 0.36 Square Metre in Vertical Surface i.e. Dado, Skirting,etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including 10mm thick Screed or Screed Bed in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate. |
| 22 | M&L Machine Cut Kota Stone Slab 20-25mm thick in Flooring over and including Cement Screed 15mm thick in Cement Mortar 1:6, laid and jointed with Grey Cement Slurry mixed with Pigment to match the Shade of the Slab including Rubbing and Polishing, complete all as specified and as directed.NOTE : Cost of Cement Screed Bed will deem to be included in the Quoted Unit Rate. |
| 23 | Taking down existing bird proof net of any size complete all as specified and as directed. |
| 24 | M & L for bird proof netting UV stabilized made of 1mm dia HDPE/Nylon wire having mesh size n.exc 25mmx25mm, tightening/securing the joint by using stainless steel wire of suitable thickness complete all as specified and as directed. |
| 25 | M & L for cleaning of existing bird proof net including necessary arrangement at a height 15mtr (Approx) complete all as specified and as direced by Engr-in-charge at site.Note:Cleaning of bird proof net shall be done atleast once in a quarter. |
| 26 | Repair of existing bird proofing net by tightening/securing the joint with stainless steel wire of suitable thickness to prevent the enrty of bird complete all as directed at site by Engr-in-Charge.Note : Joints of net to be measured. |
| 27 | S&F Welded steel wire fabric N exc 4 kg/Sqm complete to steel members, including necessary jointing/welding as required at site complete all as specified and as directed.Note for item No 23 to 27. : The work shall be executed at a height exc. 08 mtrs but n. exc. 15 mtrs or at the same height of existing/replaced bird proof net at site. |
| 28 | S&F in repair Rotational moulded polye thylene water storage tanks of 500 ltrs capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I |
| 29 | S&F in repair Rotational moulded polye thylene water storage tanks of 1000 ltrs capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I |
| 30 | S&F in repair Looking Mirror 5.0mm thick of size 600x600mm, fixed with Chromium Plated Brass Spacers 25mm to 30mm in size (One Each Corner) including rounding the edges of the Mirror and Fixed-in-repairs, complete all as specified and as directed. |
| 31 | S&F Brass Chromium Plated Tubular Towel Rail 20mm dia ‘D’ type60 Cm long with Brackets and Fixed-in-repairs, complete all as specified and as directed. |
| 32 | S & F in repairBall brass valves, high pressure, with polythene float and flynut complete for 20mm dia bore pipe , screwed for iron pipe or brass ferrule and fixed complete all as specified and as dieceted. |
| 33 | S&F in repair Chromium Plated health faucet with 1mtr stainless steel tube indcluding necessary fitting and fixtures complete all as specified and as directed by Engr-in-charge. |
| 34 | S & F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and as directed. |
| 35 | S & F brass chromium plated Urinal spreader for fixing with 15 mm dia pipe complee all as specified and as directed. |
| 36 | S & F in repair 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 37 | S & F in repair 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 38 | S & F in repair PVC (SWR) bends any 75mm bore complete all as specified and as directed |
| 39 | S & F in repair PVC (SWR) bends any 110mm bore complete all as specified and as directed |
| 40 | S & F in repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement |
| 41 | Taking up or down Steel Tubing 15mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed. |
| 42 | Taking up or down Steel Tubing 20mm bore (dia) and Connections, segregating the Serviceable Pipes and Connections, stacking properly at Site(s) and keep in Safe Custody for re-use, complete all as specified and as directed. |
| 43 | Supply & laying Steel Water Tubing 15mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other situation, complete as all specified and as directed. |
| 44 | Refixing Old Steel Tubing 15mm bore (dia) and Connections (Serviceable Pipes and Connections obtained from Item here-in-before) in new or old position (Walls, Ceiling, Floors, etc.) including cleaning both inner and outer surfaces of Pipes by using Wire Brush including provision of new GI Connections (as required ordered at Sites), complete all as specified and as directed. |
| 45 | Supply & laying Steel Water Tubing 20mm bore (dia), Galvanised, ‘medium grade’ with all Fittings, fixed on Walls, Ceiling or laid in Floors or any other situation, complete as all specified and as directed. |
| 46 | Refixing Old Steel Tubing 20mm bore (dia) and Connections (Serviceable Pipes and Connections obtained from Item No. 15 here-in-before) in new or old position (Walls, Ceiling, Floors, etc.) including cleaning both inner and outer surfaces of Pipes by using Wire Brush including provision of new GI Connections (as required ordered at Sites), complete all as specified and as directed. |
| 47 | S & F in repair PVC Flushing Cistern 10 Litre capacity White, Low Level, Valve less, Syphonic action type with Inlet, Ball Valve, Float and Handle, PVC Waste Pipe 32mm bore (dia) of suitable Length, a pair of Cast Iron Bracket/ Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and Fixed-in-repairs, complete all as specified and as directed. |
| 48 | S&F in repair Vitreous China wash basin, white, flat back, size 550x400mmexcluding taps,waste, chain and plug and porcelain stopper butincluding brackets cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe |
| 49 | S&F in repair Bib Tap 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, LongBody with Capstan Head, screwed down, screwed for Iron Pipe or for Brass Ferrule, complete all as specified and as directed. |
| 50 | S & F in rapair Pillar taps, cast copper alloy, with capstan heads, chromium plated, facny type screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed |
| 51 | S&F in repair Angle Valve 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, screwed down, high pressure, screwed both Ends for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed. |
| 52 | S&F in repair PVC Waste Pipe 32mm dia (bore) having 600mm long and fixed complete to Walls, Ceilings or in Floors, etc.and Fixed-in-repairs, complete all as specified and as directed. |
| 53 | S&F in repair PVC Connection Pipe 15mm size and 60 Cm in length with Adopter Nuts of PVC and Fixed-in-repairs, complete all as specified and as directed. |
| 54 | Taking down and refixing of Shutters of any descriptionin same opening n exc 1sq. m each complete all as specified and as directed. |
| 55 | S&F Aluminium Handle 150mm long (weight not less than 120 Gram), Extruded Section, Fabricated type, anodised, complete all as specified and as directed. |
| 56 | S&F Sheet Glass 4.0mm thick, Ordinary quality and glazing in steel windown shutter in Square exc. 0.50 Sqm in Each Pane of Windows, complete all as specified and as directed. |
| 57 | Hacking out old broken Glass (any thickness, size, quality or description) from Wooden or Metal Frames, glazed with putty or fixed with beads, complete all as specified and as directed. |
| 58 | S&F in repair Aluminium Barrel Tower Bolt 200mm long (weight not less than 210 Gram), Extruded Section, complete all as specified and as directed. |
| 59 | Repairing of NCL Door, Windows, Ventilators Shutter Fixed/ Side Hang /Sliding Type including replacement of necessary Jointing Cleats, Glazing Clips, Rubber Neoprene Packing, Screws, etc. and repairing of Locking Arrangement if any, complete all as specified and as directed.NOTE : Cost of Materials requiredfor smooth functioning of Shutter shall deem to be included in the Quoted Unit Rate. |
| 60 | S&F in repair Door Closer Aluminium (Die cast) body, hydraulically regulated, Designation No. 3, Universal type, suitable for Door Shutters of 851mm to 1000mm in width and of weight between 61.00 to 80.00 Kilogram , complete all as specified and as directed. |
| 61 | S&F in repair Double Action Floor Spring Hydraulically Regulated made up of minimum 1.25mm thick Aluminium alloy Sheet Foundation Box, Main Body with Stainless Steel Cover, Governing Pivot made of Brass, Other Parts made of Mild Steel heavy duty, complete all as specified and as directed. |
| 62 | S&F Aluminium alloy, anodized, Sliding Door Bolt 250mm long (weight not less than 330 Gram) with Hasp Staple (Bolt type) and Fixing Clips of Sheet Cast or Extruded Section and Fixing Bolts and Sliding Bolts of Extruded Section and fixing, complete all as specified and as directed. |
| 63 | Dismantling of Asbestos cement/Translucent(corrugated, semicorrugated, plain, etc.) sheets in roof/wall coverings, complete all as specified and as directed. |
| 64 | Dismantling structural steel or Mild steel work of any discription not otherwise provided for, complete all as specified. |
| 65 | S&F for Steel work in tubular/angular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, Complete. |
| 66 | S&F forPre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 67 | S&F Fibre glass reinforced transparent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed.Note: Sheet to be fixed at a height not less than 18mtr (Approx)All safety measures for the safety of workers shall be ensured by contractor before exeution of work. Insurance of worker shall be got done by conractor before execution of the work and the cost for the same shall deemed to be incudided in rate quoted by contractor. |