Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete Earthwork Excavation Footing |
| 2 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete Earthwork ExcavationPlinth |
| 3 | Supplying and filling in foundation andbasement with Crushed Stone Sand (M-Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.- M Sand filling |
| 4 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification |
| 5 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) - Centering 1 |
| 6 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) - Centering 2 For plane surfaces such asslab,beam, etc. |
| 7 | Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid) - Centering 2For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. |
| 8 | M-20 CONCRETE - Providing and laying in position, standarised design mix M-20 Grade using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325Kg/m3 and maximum water cement ratio of 0.55, including admixture(plasticiser/super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.70 cu.m.)940.50Kg of 20mm machine crushed stone jelly and with about (2.80 cu.m.)462.00Kg of 10-12mm machine crushed jelly and with about (4.25 cu.m.)701.25Kg of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor/roof slabs wherever neccessary without clambing extra, etc. complete complying with standard specification and as directed by the departmental officers. the coarse and fine aggregates to be used should comply with the requierments of IS 383-2016. (No separate payment will be made by the department for the exces usage of materials as per design mix.) Basement |
| 9 | M-20 CONCRETE - Providing and laying in position, standarised design mix M-20 Grade using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325Kg/m3 and maximum water cement ratio of 0.55, including admixture(plasticiser/super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.70 cu.m.)940.50Kg of 20mm machine crushed stone jelly and with about (2.80 cu.m.)462.00Kg of 10-12mm machine crushed jelly and with about (4.25 cu.m.)701.25Kg of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor/roof slabs wherever neccessary without clambing extra, etc. complete complying with standard specification and as directed by the departmental officers. the coarse and fine aggregates to be used should comply with the requierments of IS 383-2016. (No separate payment will be made by the department for the exces usage of materials as per design mix.) Ground floor |
| 10 | Suppling and fabricating and placing in position MS(or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost ofsteel and binding wire also in all floors. |
| 11 | Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9\"X43/8\"X 2 3/4\" including finishing, curing, etc., complete complying with standard specification.- Basement |
| 12 | Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9\"X43/8\"X 2 3/4\" including finishing, curing, etc., complete complying with standard specification.-Ground floor |
| 13 | Supplying and filling in foundation andbasement with Good earth in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.- Basement filling |
| 14 | Brick partition walls of 10.80cm thickness using best quality country bricks of size 8-3/4\" x 4-1/4\" x 2-1/4\" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 15 | Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 16 | Plastering with cement mortar (1:3) 10mm thick in all floors including cost and conveyance of all materials to site and labour charges etc, complete complying with standard specifications (S.I.309 |
| 17 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. |
| 18 | Painting 2 coats with approved cement paint over cement plastered wall surface, ceiling and other new surface and including cleaning, preparing the surface and curing etc., complete. |
| 19 | Paving the floor with design antiskid ceramic tiles (colour and shade as directed) of size 305mm x 305 mm x 6mm in all floor aver a base layer of cement mortar 1:3 (one cement and three sand) 20 mm thick laid in situ and pointed with same coloured cement. |
| 20 | Finishing the top of floor with Granolithic Finish with CC 1: 2: 4 (one cement, two sand & four HBG jelly) using chips of grade 10 mm andbelow for 25mm thickness and rubbed smooth etc, complete as per standard specification |
| 21 | Dadooing walls withGlazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 22 | Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for paneling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rebate for housing the shutter and should have provision to fix AL drops, tower bolt hinges and lock plates inclusive of cost of all materials etc. complete complying with thew standard specifications. |
| 23 | Providing and fixing louvered ventilator fabricated from roll formed sections made of galvanized steel colour coated or reported they still as per IS 513 D quality galvanized as per IS 277 with the zinc of 120 grams per sqm) with the total coated thickness ofPaint specification: court at sections should be with primer court of epoxy primer of 5-7 microns thick,Finish painted with polyester paint of 12 - 16 microns thick,Dimensions of the sections: the section for external frame should be 57 mm x 33 mmFixing details: the section should be cut to length joint with profile to profile componentAccessories: glass holding planes made of glass filled nylonGlass: louveres to be provided with 4 mm pin headed glassGrill: ventilator should be provided with grill made of 10 mm square MS bar to 12 mm x 5mm flat at 4 inch intervals. Total grill unit should be powder coated and fix it to ventilator frame with screws.The frames should be fixed to brick or concrete / Masonry walls and floor by means of self expaning screws |
| 24 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 25 | Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1 mm thick) of size 100 mm x 60 mm with a rebate of 30/ 35 mm x 15 mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel Hold fast etc.,PWD SOR P.NO 158 |
| 26 | Supplying & fixingdoor shutters for Mediun Density Fiber Board of exterior grade 35 mm thick,single leaf conforming to IS:12406/1989 with 35x12 mm T.W.Lipping on all edges with necessary adhesives and CP screws complying with standard specifications. The rate is inclusive ofthreee coats of best quality varnish but excluding cost of furniture fittings.such as 300 mm tower bolt 2nos,200mm towerbolt I no. 300mm Aldrop 1 No. Alu handle ornamental type 2 Nos,and 1 No. Door stopper etc complete. |
| 27 | Supplying and fixing in position best approved of BIS quality PVC Waste waterpipes having a pressure of 6 kg. / sq.cm including cost of special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 6.0 meter pipe length, etc., complete complying with standard specification.110mm dia pipe |
| 28 | Supplying and fixing in position best approved of BIS quality PVC Waste waterpipes having a pressure of 6 kg. / sq.cm including cost of special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 6.0 meter pipe length, etc., complete complying with standard specification. 90mm dia pipe |
| 29 | Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading,unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., 1000 litres capacity |
| 30 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work.25mm Gun metal Gate Valve |
| 31 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. 32mm Gun metal Gate Valve |
| 32 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) SD Tap |
| 33 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) Pillar Tap |
| 34 | Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 25mm dia |
| 35 | Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works.32mm dia |
| 36 | Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges up to 4 meter height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works.32mm dia |
| 37 | Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements25 mm Dia Coupler |
| 38 | 32 mm DiaCoupler |
| 39 | 25 mm Dia Elbow |
| 40 | 32 mm DiaElbow |
| 41 | 25 mm DiaBEND |
| 42 | 32 mm Dia BEND |
| 43 | 25 mm Dia Tee |
| 44 | 32 mm DiaTee |
| 45 | 25 mm Dia End Cap |
| 46 | 32 mm DiaEnd Cap |
| 47 | 20 mm x 15 mmReducer |
| 48 | 25 mm x 20 mm Reducer |
| 49 | 20 mm x 15 mm Reducer Tee |
| 50 | 25 mm x 20 mm Reducer Tee |
| 51 | 32 mm x 25 mmReducer Tee |
| 52 | 20 mm x 15 mmReducer Elbow |
| 53 | 25 mm x 20 mmReducer Elbow |
| 54 | 25 mm DiaJet Nipple |
| 55 | 32 mm DiaJet Nipple |
| 56 | Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works). 110mm dia PVC Elbow |
| 57 | 90mm diaPVC Elbow |
| 58 | 110mm dia PVC Elbow with Door |
| 59 | 90mm diaPVC Elbow with Door |
| 60 | 110mm dia PVC Tee |
| 61 | 90mm dia PVC Tee |
| 62 | 110mm diaPVC Tee with Single Door |
| 63 | 90mm dia PVC Tee with Single Door |
| 64 | 110mm dia PVC \"Y\" with Single Door |
| 65 | 90mm dia PVC \"Y\" with Single Door |
| 66 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthenware wash hand basin of size 550 x 400mm (with pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \"B\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylon connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 67 | Supplying and fixing in position 15mm dia C.P.Shower rose & stop cock ofapproved make confirming to IS specifications and quality including cost ofShellac thread etc. complying with standard specification.C.P. Shower Rose |
| 68 | Supplying and fixing in positionC.P. Towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plug and C.P.Screws etc. complete complying with standard specification. |
| 69 | Supplying and fixing in positionC.P. Soap tray of size 150 x 150mm including cost of teak wood plug and C.P. screws. etc. complete complying with standard specification. |
| 70 | Supplying and fixing in positionIndian make bewelled edge mirror of size 600 x 450mm quality including cost of Rawal plugs, brass screws. etc. complying with standard specification. |
| 71 | Supplying and fixing in position Indian Water Closet (Oriya type) of size 580 x 440mm White/Color glazed earthen ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with Sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two Sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). |
| 72 | Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm \"P\" or \"S\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings. |
| 73 | Supply and fixing in position of best Indian make white / colour glazed earthenware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masonry and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) |
| 74 | Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of Sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three Sand ) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 75 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \"U\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
| 76 | Providing rain water harvesting using 3 No.of RCC well rings of 90cm inner dia (clear) with 5cm wall thickness made out of cement concrete 1:2:4 using 20mm hard broken jelly to a height of 30cm each supplying and fabricating 16 No. of 6mm dia MS rod vertically and 3 No. of 6mm dia MS rod circumferentially tied together with 18 guage binding wire for well rings including necessary earth work excavation 1m dia toa depth of 1m, supplying and filling 40mm HBG inside the erected well ring to a depth of 90cm, and top covered with RCC circular perforated cover slab of 1m dia and 5cm thick which inclusive of cost and fabrication of 6mm M.S reinforcement at 15 cm spacings on both directions and one 6mm M.S rod ties at the edge of the slab circumferentially including cost of moulding, curing, finishing and well placing in position and disposing off excavated earth with all initial leads and lifts in places as shown by the Departmental officers etc., complete in all respects. |
| 77 | Conducting Geophysical survey, quality and quantity test and transportation charges etc, (This includes labour charges in the field, rent of the vehicle for reaching the place, rent of the instrument and excluding charges for the geologist) |
| 78 | Drilling of 150mm dia vertical bores in hard rock formation to any required depth as directed by the departmental officers including labour charges for inserting casing pipe, assembling in the drilled hole, including welding the joints if necessary grouting the casing pipe etc, and including transportation charges for the rig and supporting vehicles from one place to another place.Over Burden Soil |
| 79 | Supply and delivery of unplasticised ribbed screen PVC casing pipe of the 150mm dia in 3m length with screwed and socket end and centering guide for every 15m length of pipes as per IS / 12818 / 1992 and as amended from time to time to suit the borewell upto 80m depth (C.S) with ISI marking including, loading, unloading , freight, stacking and transit insurance charges etc, complete.(TWAD Board Rates in Page No. 22) |
| 80 | Supply and delivery of clear water vertical wet type submersible pump conforming to is 8034/2002 and as amended threafter and BEE 3 Star Rated capable of discharging notes 20 lpm x 100 m against head of water column due to all causes. The pump shall be with stainless steel shaft and dyamically balaced bronze or Cast SS impeller, brass screws and CI FG 200 grade two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+- 10 %, 50 HZ +/- 5 %. (TWAD Board Rates in Page No: 100) |
| 81 | Labour charges for the erection of submersible pump set in bore well/open well including fixing and jointing submersible cable with proper clamps up to the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges up to the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventer, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pump set and trail run for 10 days.(TWAD Board Rates in Page No:308) |
| 82 | Supply and delivery of Single Phase Panel Board - Star Delta with two level Guard and auto start suitable for Submersible pumpsets and accessories including all fittings suitable for Submersible pump sets.Panel Board should be provided as per specification. Rates inclusive of Packing, Loading, Freight, Unloading, Stacking, Transit andInsurance charges etc, complete. (TWAD Board Rates in Page No:114) |
| 83 | Supply, delivery and fixing of UPVC pipe(un-plasticized Polyvinyl Chloride) UPVC used for residential and home applications, water pressure in residential areas do not normally exceed the maximum tolerance.(shedule - 40) 32mm dia etc.,(PWD Board Rates in Page No:112) |
| 84 | Supplying and fixing of PVC insulated and sheathed 3 core 4sq.mm Flat type Copper cable cofirming to IS 694/ 1990 and including cost and conveyance of all materials to site and labour charges etc, complete as per standard specification. (TWAD Board Rates in Page No: 120) |
| 85 | Supplying fixing of 32mm dia G.I pipe B class with ISI mark standard quality, standard weight including transporting the same to the site directed by the departmental officers etc complete |
| 86 | Supplyingand fixing of Bore well fittings as per standard specification as directed by the departmentaol officers etc., complete 32 mm Dia GI Elbow |
| 87 | 32mm Dia GI Nipple |
| 88 | 32mm CI flangeset with bolt nut insert rubber |
| 89 | 40 mm dia Mild steel clamp set |
| 90 | 32 mm dia GI Coupling |
| 91 | 32mm C.I. borewell motor Adoptor |
| 92 | 160mm Borewell pvc endcup |
| 93 | Nylon rope 8mm |
| 94 | 32mm Gate valve |
| 95 | 20mm PVC Tap |
| 96 | ELECTRICAL WORKS Earthling as per ISI Specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm and with 20mm dia copper earth flat of size 125mm x50mmx6mm, with funneling arrangement using charcoal, common salt, G.I.reducer, check nuts etc.,and masonry work and providing RCC cover slab 38mm thick for the Brick masonry including cost of steel and fabrication of reinforcement etc., complete in all respects as directed by the departmental officers. (SD 233) |
| 97 | Supplying and run off 8 SWG copper wire on walls or below ground level with necessary \"U\" nails, earth work excavation and refilling & including the cost of all materials etc., complete in all respects as directed by the departmental officers.(SD 75) |
| 98 | Supplying and Fixing of 3 Phase DB with MCB 12 way TPMCB sheet steel distribution boards (flush type/surface type) fitted with bus bars and neutral links with three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pile incoming MCB / Isolator and another separate 4 way provision for accommodating One No. 4 pole ELCB / RCD (totally 8 ways in one segment) (3 x 4 ways in each segment) and separate provisions for MCB / Isolator (totally 12 Nos.) for sub incomers in 3 segments with label holder etc.complete in all respects as directed by the departmental officers |
| 99 | Supply and run off 2 of 2.50sqm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continuousearth connection by means of 1.50 sqm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departmental officers. (derived from SD 55) |
| 100 | Supply and run off 2 of 1.5 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI markconfirming to IS:694/1990 with continiousearth connection by means of 1.50 sqm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wallfor mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 54) |
| 101 | Supply and fixing of TNEB meter Board suitable for 32 A Three phase service connection with 32A fuse unit(500V)32A neutral link and earth link (1\" x 1/8\" Copper flat) on T.W plank of size 600mm x450mm x 19mm with supportingT.W.reepers of 1\" thick oneither sider with painting withsuitable bolt and nuts for fixingthe TW plank on wall withearth connection and interconnection with 7/20 PVCinsulated copper wire from EBmeter to fuse unit. SD 127) |
| 102 | Supply and run of 4 core 16 Sq.mm PVC Armoured cableof 1100 V grade with ISI mark.(Part E r) V |
| 103 | Supply and run of 4 core 10 Sq.mm PVC Armoured cableof 1100 V grade with ISI mark.(Part E c) V |
| 104 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T. switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For Electronic regulator). SD 23 |
| 105 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. SD 38 |
| 106 | 18 W LED Tubelight for T8 Fitting Single side (15- e) |
| 107 | Supplying and fixing 12\" (30cm dia) light duty Exhaust fan including cost of all materials,labour, lead, lift, etc complete |
| 108 | add for GST @ 18% |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy