Supplying Fixing And Installation Of Diesel Generator Set 100Kva With Amf Panel At Fatehpur., fatehpur-Rajasthan

Department Of Local Bodies has published Supplying Fixing And Installation Of Diesel Generator Set 100Kva With Amf Panel At Fatehpur.. Submission Date for this Tender is 04-07-2023. Diesel Generators Tenders in fatehpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

38386094
Supplying Fixing And Installation Of Diesel Generator Set 100Kva With Amf Panel At Fatehpur.
Open Tender
Indian
Rajasthan
fatehpur
04-07-2023

Tender Details

Supplying Fixing And Installation Of Diesel Generator Set 100Kva With Amf Panel At Fatehpur.

Key Value

Document Fees
INR 1000 /-
EMD
INR 21160.0 /-
Tender Value
INR 10.58 Lakhs /-

BOQ Items

Name of Work : Supplying fixing and installation of D.G. Set 100KVA with AMF panel at Fatehpur.
Sl. No. Item Description
1Laying and Jointing PVC Pipe. Heading
2Supply , Installation, Testing and Comissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,HA. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupledC. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, with protection and tripping of DG set against temperature of more than 50 degree centigradeD. Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger, Engine instruments panel, AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring & control system, MCCB/ACB of suitable rating, mmeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible 100 KVA at 0.8 pf 415V 50Hz 3-? and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity : E. (A) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (B).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (C)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA. F. First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department. G. Servicing of the DG set (as per OEM guidelines) during the DLP period shall be done by contractor including all consumables,actual charges shall be reimbursed to the contractor by department/client complete in all respect. H. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA/ CPCB standards approved lab type test reports before execution as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with
3Supply , Installation, Testing and Comissioning of Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick , Powdercoated finish , Engine Start & Stop commands, control Relays , Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable for following capacity DG sets. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA lab type test reports before execution as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 100 to 140 KVA