Planning And Development Department has published Tender For Infrastructure Development Of Heritage Complex, Rajbari, Shillong.. Submission Date for this Tender is 18-07-2023. Infrastructure Work Tenders in Shillong Meghalaya. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 04-Jul-2023 | Modified BoQ | Other | 18-07-2023 |
Sl. No. | Item Description |
1 | CIVIL WORK |
2 | GROUND FLOOR |
3 | Earth work in excavation by manuav mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 in in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 in and lift up to 1.5 in, as directed by Engineer-in-charge. (a) All kinds of soil. |
4 | Sand filling in plinth in layers not exceeding 150 mm thick including breaking Of clods, consolidating by ramming and watering complete as directed (maximum depth 45 cm) |
5 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). 1 :4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
6 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge.(a) All works upto plinth level |
7 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. (b) All works above plinth level up to first floor. |
8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. |
9 | (b) All works above plinth level up to first floor. |
10 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required). (a) Thermo-Mechanically Treated bars |
11 | Centerlng and shutterlng lncludlng struttlng, propplng etc. and removal of form for all heights complcte and as directed by Engineer in charge. |
12 | (a)Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
13 | (b) Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
14 | (c) Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
15 | (d)Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
16 | (e) Edgesofslabs and breaks in floors and walls (using timber) |
17 | under 20 cm wide |
18 | (f) Stairs/ spiral staircase, (excluding landings) (using timber) |
19 | Brick work with common burnt clay modular lst class bricks in foundation and in plinth: (a) Cement mortar 1:4 (1 cement : 4 coarse sand) |
20 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level. ( a ) Cement mortar 1:3 (1 cement :3 coarse sand) |
21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make contorming to ls:733 and ls:1285, fixing with dash fasteners of required diameter and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, and panelling to be paid for separately): (b) For shutters ot doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing Of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately). (a) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
22 | Providing and fixing glazing in aluminium door. window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge: |
23 | (a) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
24 | Providing wood work in frames Of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length |
25 | (a) With Teak wood/ Sissu wood |
26 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) (a) With Teak wood/ Sissu wood. (a) 35 mm thick shutters |
27 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30xl0xl5 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). |
28 | Providing and fixing aluminium sliding door bolts, lsl marked anodised (anodic coating not less than grade AC 10 as per ls:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:(a) 300x16 mm |
29 | Providing and fixing aluminium tower bolts, Isl marked, anodised (anodic coating not less than grade AC 10 as per ls:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:(a) 250x10 mm |
30 | Providing and fixing aluminium handles, lsl marked, anodised (anodic coating not less than grade AC 10 as per ls:1868) transparent or dyed to required coloilr or shade, withnecessary screws etc. complete:(a) 125 mm |
31 | Providing and laying vitrified floor tiles in different sizes (thickness to be specif led by the manufacturer) with water absorption less than O.08°/o and conforming to ls:15622, of approved make, in all colours and shades laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc„ complete.(a)Size of Tile 600x600 mm |
32 | Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 a/a and conforming to ls:15622, of approved make, jn all colours and shade, in skirting, riser of steps, over 12 mm thick bed Of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. (a) Size of Tile 600x600 mm |
33 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: |
34 | (a) Makrana white second quality |
35 | Chequered terrazzo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade Of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1 :4 (1 cement : 4 coarse sand) : (a) Medium shade pigment using 50% white cement, 50% ordinary cement |
36 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
37 | 12 mm cement plaster1:4 (1 cement: 4 coarse sand) |
38 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : |
40 | (a) New work (two or more coats) |
41 | Finishing walls with toxtured exterior paint of required shade, including scaffolding: |
42 | (a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
43 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, Vc fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered). |
44 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
45 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a) Stone soling (i) 100mm |
46 | Providing and fixing M.S. holder bat clamps Of approved design to C.I. or S.C.I. rainwater pipes embedded in and including cement concrete blocks 10xl0xlo cm Of 1 :2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls, eto.:(b) 100 mm diameter |
47 | SANITARY WORK |
48 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P, flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials Of standard make and mosquito proof coupling Of approved design complete, including painting Of fittings and brackets, cutting and making good the walls and floors wherever required: (a) W.C. pan with lsl marked white solid plastic seat and lid |
49 | Providing and fjxjng white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per ls:2556, C.I. trap with outlet grating and other couplings in C.P, brass, including painting of fittings and cutting and making good the walls and tlcors wherever required: (a) flange of three urinal basins with 10 litre white P.V.C. automatic flushing cistern |
50 | Providing and fixing wash basin with C.I. brackets, 15 mm dia. CP Brass single hole basin mixer Of approved quality and make, including painting Of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
51 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 320 or 40 mm dia |
52 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
53 | Providing and fixing kitchen sink including making all connections excluding cost of fittings. (a) White glazed fire clay sink of size 600x450x250mm |
54 | Providing and fixing 8 mm dia. C.P/ S.S Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. Of quality and make as approved by Engineer-in-charge |
55 | Providing and fixing toilet paper holder : C.P. brass |
56 | Providing and fixing soil, waste and vent pipes : 100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
57 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Centrifugally cast (spun) iron socketed pipe as per IS: 3989 |
58 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 75 mm dia pipe |
59 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe |
60 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 3989 |
61 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 75 mm dia Sand cast iron S&S as per IS- 3989 |
62 | Providing and fixing plain bend of required degree. 100 mm dia Sand cast iron S&S as per IS : 3989 |
63 | Providing and fixing plain bend of required degree. 75 mm dia Sand cast iron S&S as per IS - 3989 |
64 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm |
65 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 75 mm |
66 | WATER SUPPLY WORK |
67 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(iii) 25 mm nominal outer diameter pipes |
68 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(iii) 32 mm nominal outer diameter pipes |
69 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
70 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
71 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore |
72 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: a 150 mm diamter |
73 | Septic tank |
74 | Earth work in excavation by manuav mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 in in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 in and lift up to 1.5 in, as directed by Engineer-in-charge |
75 | (a) All kinds of soil. |
76 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). |
77 | 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
78 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). |
79 | 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
80 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. (b) All works above plinth level up to first floor. |
81 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) |
82 | (a) Thermo-Mechanically Treated bars |
83 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level, |
84 | ( a ) Cement mortar 1:3 (1 cement :3 coarse sand) |
85 | Centerlng and shutterlng lncludlng struttlng, propplng etc. and removal of form for all heights complcte and as directed by Engineer in charge. |
86 | (a)Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
87 | (d)Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
88 | (b) Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
89 | Brick work with common burnt clay modular lst class bricks in foundation and in plinth: |
90 | (a) Cement mortar 1:4 (1 cement : 4 coarse sand) |
91 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4(1 cement: 4 coarse sand) |
92 | Under ground water sump |
93 | Earth work in excavation by manuav mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 in in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 in and lift up to 1.5 in, as directed by Engineer-in-charge. (a) All kinds of soil. |
94 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) 1:4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
95 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. (b) All works above plinth level up to first floor. |
96 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) |
97 | (a) Thermo-Mechanically Treated bars |
98 | Centerlng and shutterlng lncludlng struttlng, propplng etc. and removal of form for all heights complcte and as directed by Engineer in charge. |
99 | (a)Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
100 | (d)Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
101 | (b) Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
102 | FIRST FLOOR |
103 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. (b) All works above plinth level up to first floor. |
104 | Extra over item No 6.2 to 6.8 above for each subsequent floor or part thereof above the first floor level |
105 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. (b) All works above plinth level up to first floor. |
106 | Extra over item No 6.2 to 6.8 above for each subsequent floor or part thereof above the first floor level |
107 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required). (a) Thermo-Mechanically Treated bars. Extra over item 6.11 (a, b, c) above for each subsequent floor or part thereof above first floor level. |
108 | Centerlng and shutterlng lncludlng struttlng, propplng etc. and removal of form for all heights complcte and as directed by Engineer in charge. |
109 | (b) Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
110 | ( c ) Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
111 | (d)Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
112 | ( e ) Edgesofslabs and breaks in floors and walls (using timber) |
113 | under 20 cm wide |
114 | (f) Stairs/ spiral staircase, (excluding landings) (using timber) |
115 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level. ( a ) Cement mortar 1:3 (1 cement :3 coarse sand). Extra over item No 7.8 and 7.10 above for each subsequent floor or part thereof above the first floor level. |
116 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make contorming to ls:733 and ls:1285, fixing with dash fasteners of required diameter and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, and panelling to be paid for separately): (b) For shutters ot doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing Of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately). (a) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
117 | Providing and fixing glazing in aluminium door. window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge: (a) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
118 | Providing wood work in frames Of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length. (a) With Teak wood/ Sissu wood |
119 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) (a) With Teak wood/ Sissu wood. (a) 35 mm thick shutters |
120 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30xl0xl5 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). |
121 | Providing and fixing aluminium sliding door bolts, lsl marked anodised (anodic coating not less than grade AC 10 as per ls:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:(a) 300x16 mm |
122 | Providing and fixing aluminium tower bolts, Isl marked, anodised (anodic coating not less than grade AC 10 as per ls:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: (a) 250x10 mm |
123 | Providing and fixing aluminium handles, lsl marked, anodised (anodic coating not less than grade AC 10 as per ls:1868) transparent or dyed to required coloilr or shade, withnecessary screws etc. complete: v |
124 | Providing and laying vitrified floor tiles in different sizes (thickness to be specif led by the manufacturer) with water absorption less than O.08°/o and conforming to ls:15622, of approved make, in all colours and shades laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc„ complete.(a)Size of Tile 600x600 mm |
125 | Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 a/a and conforming to ls:15622, of approved make, jn all colours and shade, in skirting, riser of steps, over 12 mm thick bed Of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. (a) Size of Tile 600x600 mm |
126 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: (a) Makrana white second quality |
127 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
128 | 12 mm cement plaster1:4 (1 cement: 4 coarse sand) |
129 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
130 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work |
131 | Finishing walls with textured exterior paint of required shade : (a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
132 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, Vc fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered). |
133 | Providing and fixing M.S. holder bat clamps Of approved design to C.I. or S.C.I. rainwater pipes embedded in and including cement concrete blocks 10xl0xlo cm Of 1 :2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls, eto.:(b) 100 mm diameter |
134 | SANITARY WORK |
135 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P, flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials Of standard make and mosquito proof coupling Of approved design complete, including painting Of fittings and brackets, cutting and making good the walls and floors wherever required: (a) W.C. pan with lsl marked white solid plastic seat and lid |
136 | Providing and fjxjng white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per ls:2556, C.I. trap with outlet grating and other couplings in C.P, brass, including painting of fittings and cutting and making good the walls and tlcors wherever required: (a) flange of three urinal basins with 10 litre white P.V.C. automatic flushing cistern |
137 | Providing and fixing wash basin with C.I. brackets, 15 mm dia. CP Brass single hole basin mixer Of approved quality and make, including painting Of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
138 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 320 or 40 mm dia |
139 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
140 | Providing and fixing 8 mm dia. C.P/ S.S Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. Of quality and make as approved by Engineer-in-charge |
141 | Providing and fixing toilet paper holder : C.P. brass |
142 | Providing and fixing soil, waste and vent pipes : 100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
143 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Centrifugally cast (spun) iron socketed pipe as per IS: 3989 |
144 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 75 mm dia pipe |
145 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe |
146 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 3989 |
147 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 75 mm dia Sand cast iron S&S as per IS- 3989 |
148 | Providing and fixing plain bend of required degree. 100 mm dia Sand cast iron S&S as per IS : 3989 |
149 | Providing and fixing plain bend of required degree. 75 mm dia Sand cast iron S&S as per IS - 3989 |
150 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm |
151 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 75 mm |
152 | WATER SUPPLY WORK |
153 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(iii) 25 mm nominal outer diameter pipes |
154 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(iii) 32 mm nominal outer diameter pipes |
155 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
156 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
157 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore |
158 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: a 150 mm diamter |
159 | SECOND FLOOR |
160 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge(b) All works above plinth level up to first floor. Extra over item No 6.2 to 6.8 above for each subsequent floor or part thereof above the first floor level |
161 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. (b) All works above plinth level up to first floor.Extra over item No 6.2 to 6.8 above for each subsequent floor or part thereof above the first floor level |
162 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required). (a) Thermo-Mechanically Treated bars. Extra over item 6.11 (a, b, c) above for each subsequent floor or part thereof above first floor level. |
163 | Centering and shuttering including strutting, propping etc. and removal of form for : |
164 | (b) Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
165 | ( c ) Columns, Pillars, Piers, Abutments, Posts and Struts |
166 | (d) Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
167 | ( e ) Edges of slabs and breaks in floors and walls under 20 cm wide |
168 | (f) Stairs, (excluding landings) except spiral-staircases |
169 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. ( a ) Cement mortar 1:3 (1 cement :3 coarse sand). Extra over item No 7.8 and 7.10 above for each subsequent floor or part thereof above the first floor level. |
170 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) (a) For shutters of windows and ventilator i/c providing and fixing hinges or pivots and making provision for fixing of fitting wherever required i/c thw cost of EPDM rubber/neiprene gasket required ( fitting shall be paid for seperately). (a) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
171 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (a) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
172 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length. (a) With Teak wood/ Sissu wood |
173 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) (a) With Teak wood/ Sissu wood. (a) 35 mm thick shutters |
174 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30xl0xl5 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). |
175 | Providing and fixing aluminium sliding door bolts, lsl marked anodised (anodic coating not less than grade AC 10 as per ls:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:(a) 300x16 mm |
176 | Providing and fixing aluminium tower bolts, Isl marked, anodised (anodic coating not less than grade AC 10 as per ls:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: (a) 250x10 mm |
177 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per ls:1868) transparent or dyed to required coloilr or shade, withnecessary screws etc. complete: (a) 125 mm |
178 | Providing and laying vitrified floor tiles in different sizes (thickness to be specif led by the manufacturer) with water absorption less than O.08°/o and conforming to ls:15622, of approved make, in all colours and shades laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc„ complete.(a)Size of Tile 600x600 mm |
179 | Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 a/a and conforming to ls:15622, of approved make, jn all colours and shade, in skirting, riser of steps, over 12 mm thick bed Of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. (a) Size of Tile 600x600 mm |
180 | Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with: (a) Makrana white second quality |
181 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
182 | 12 mm cement plaster1:4 (1 cement: 4 coarse sand) |
183 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
184 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work |
185 | Finishing walls with textured exterior paint of required shade : (a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
186 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, Vc fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered). |
187 | Providing and fixing M.S. holder bat clamps Of approved design to C.I. or S.C.I. rainwater pipes embedded in and including cement concrete blocks 10xl0xlo cm Of 1 :2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls, eto.(b) 100 mm diameter |
188 | SANITARY WORK |
189 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P, flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials Of standard make and mosquito proof coupling Of approved design complete, including painting Of fittings and brackets, cutting and making good the walls and floors wherever required: (a) W.C. pan with lsl marked white solid plastic seat and lid |
190 | Providing and fjxjng white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per ls:2556, C.I. trap with outlet grating and other couplings in C.P, brass, including painting of fittings and cutting and making good the walls and tlcors wherever required: (a) flange of three urinal basins with 10 litre white P.V.C. automatic flushing cistern |
191 | Providing and fixing wash basin with C.I. brackets, 15 mm dia. CP Brass single hole basin mixer Of approved quality and make, including painting Of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
192 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 320 or 40 mm dia |
193 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
194 | Providing and fixing 8 mm dia. C.P/ S.S Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. Of quality and make as approved by Engineer-in-charge |
195 | Providing and fixing toilet paper holder : C.P. brass |
196 | Providing and fixing soil, waste and vent pipes : 100 mm dia Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
197 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Centrifugally cast (spun) iron socketed pipe as per IS: 3989 |
198 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 75 mm dia pipe |
199 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe |
200 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 3989 |
201 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 75 mm dia Sand cast iron S&S as per IS- 3989 |
202 | Providing and fixing plain bend of required degree. 100 mm dia Sand cast iron S&S as per IS : 3989 |
203 | Providing and fixing plain bend of required degree. 75 mm dia Sand cast iron S&S as per IS - 3989 |
204 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 100 mm |
205 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 75 mm |
206 | WATER SUPPLY WORK |
207 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(iii) 25 mm nominal outer diameter pipes |
208 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(iii) 32 mm nominal outer diameter pipes |
209 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :15 mm nominal bore |
210 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (a)15 mm nominal bore |
211 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore |
212 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: a 150 mm diamter |
213 | MUMMTY FLOOR |
214 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. (b) All works above plinth level up to first floor. |
215 | Extra over item No 6.2 to 6.8 above for each subsequent floor or part thereof above the first floor level |
216 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. (b) All works above plinth level up to first floor. Extra over item No 6.2 to 6.8 above for each subsequent floor or part thereof above the first floor level |
217 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) |
218 | (a) Thermo-Mechanically Treated bars |
219 | Extra over item 6.11 (a, b, c) above for each subsequent floor or part thereof above first floor level. |
220 | Centerlng and shutterlng lncludlng struttlng, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge. |
221 | (b) Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
222 | ( c ) Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
223 | (d)Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
224 | ( e ) Edgesofslabs and breaks in floors and walls (using timber) under 20 cm wide |
225 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level, |
226 | ( a ) Cement mortar 1:3 (1 cement :3 coarse sand). Extra over item No 7.8 and 7.10 above for each subsequent floor or part thereof above the first floor level. |
227 | Providing wood work in frames Of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length. (a) With Teak wood/ Sissu wood |
228 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) (a) With Teak wood/ Sissu wood. (a) 35 mm thick shutters |
229 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30xl0xl5 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). |
230 | Providing and fixing aluminium sliding door bolts, lsl marked anodised (anodic coating not less than grade AC 10 as per ls:1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete:(a) 300x16 mm |
231 | Providing and fixing aluminium tower bolts, Isl marked, anodised (anodic coating not less than grade AC 10 as per ls:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete: (a) 250x10 mm |
232 | Providing and fixing aluminium handles, lsl marked, anodised (anodic coating not less than grade AC 10 as per ls:1868) transparent or dyed to required coloilr or shade, withnecessary screws etc. complete: (a) 125 mm |
233 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
234 | 12 mm cement plaster1:4 (1 cement: 4 coarse sand) |
235 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
236 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work |
237 | Finishing walls with textured exterior paint of required shade : (a) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
238 | Providing and fixing M.S. holder bat clamps Of approved design to C.I. or S.C.I. rainwater pipes embedded in and including cement concrete blocks 10xl0xlo cm Of 1 :2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls, etc.:(b) 100 mm diameter |
239 | Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth courses of blown or/ and residual bitumen applied hot at 1.45, 1.20 and 1.70 kg per square metre of area respectively, second and fourth courses of roofing felt type 2 grade-I/ grade-ll (fibre base self-finished bitumen felt) six and final courses of stone grit 6 mm and down size or pea sized gravel spread at 0.006 cum/sqm including preparation Of surface, excluding grading, compete. |
240 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ls:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
241 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(iii) 32 mm nominal outer diameter pipes |
242 | Wiring |
243 | Wiring in concealed with 2 x 1.5 sq.mm. PVC insulated single core conductor of 660 V grade in No.16 Swg, HeavyGaugewelded stove enameled painted, 20 mm dia MS conduit pipe (E.T) i/c accessories such as bends, Tees, junction boxes, sockets, locknuts brass brushes, etc and required sizes of MS Box and recommended front plate for housing switchs, sockets, fan regulator bell push, etc matching the colour of the surrounding wall, etc as reqd. or as directed by the Engineer incharge or Architect i/c earthing conduit. |
244 | Long point wiring upto 10 mtrs |
245 | Medium point wiring upto 6 mtrs |
246 | Short point wiring upto 3 mtrs |
247 | Concealed wiring with looping in system with 2x 1.5 sq.mm. PVC insulated single core cable of 600V grade in heavy gauge PVC pipe i/c occupying and fitting of elbows, bend, fees, junction boxes etc i/c reqd. size of MS concealed boxes and front plate for housing of switches, sockets, fan regulator, bell push etc complete to light point. for Stair cases/ Two Way Switch Light point controlled by 2 Nos, 2 Way 5 Amp Switches. (a) Long point wiring upto 10 mtrs |
248 | Drawing of Mainand Sub Main Line wiring approved VIR or PVC cable 250 V Grade in Heavy Gauge 16 Swg E.T. Conduit pipe with all necessary Accessories. |
249 | With 2 x 2.5 sq.mm copper conductor |
250 | With 2 x 4.0 sq.mm copper conductor |
251 | With 2 x 6.0 sq.mm copper conductor |
252 | Drawing of 3 phase line 4 wire with approved VIR or PVC cable 250 V Grade in Heavy Gauge 16 Swg E.T. Conduit pipe with all necessary Accessories. |
253 | With 4 x 2.5 sq.mm copper conductor |
254 | With 4 x 16.0 sq.mm copper conductor |
255 | Wiring in concealed with 2 x 4.0 sq.mm. PVC insulated single core conductor of 660 V grade in No.16 Swg, HeavyGaugewelded stove enameled painted, 20 mm dia MS conduit pipe (E.T) i/c accessories such as bends, Tees, junction boxes, sockets, locknuts brass brushes, etc and required sizes of MS Box and recommended front plate for housing switchs, sockets, fan regulator bell push, etc matching the colour of the surrounding wall, etc as reqd. or as directed by the Engineer incharge or Architect i/c earthing conduit. for Power Plug points. (a) Long point wiring upto 10 mtrs |
256 | Wiring in concealed with 2 x 1.5 sq.mm. PVC insulated single core conductor of 660 V grade in No.16 Swg, HeavyGaugewelded stove enameled painted, 20 mm dia MS conduit pipe (E.T) i/c accessories such as bends, Tees, junction boxes, sockets, locknuts brass brushes, etc and required sizes of MS Box and recommended front plate for housing switchs, sockets, fan regulator bell push, etc matching the colour of the surrounding wall, etc as reqd. or as directed by the Engineer incharge or Architect i/c earthing conduit. fora ceiling fan/ exhaust fan point. (a) Long point wiring upto 10 mtrs |
257 | S/F suitable size GI box with modular plate and cover in front on surface or in recess, i/c pf 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
258 | Distribution & Mains. |
259 | S/ F of following way, SPN, Sheet Steel MCB DB, 240V on surface/recess, complete with tinned cu. busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted i/c earthing etc as reqd. |
260 | 12 way , Double door |
261 | 8 way, Double door. |
262 | S/ F following rating 240 / 415volts "C" series, MCB/ Isolator suitable for inductive load of following pole in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. |
263 | 5-32 Amp Single pole MCB |
264 | 5-32 Amp Single pole & Neutral MCB |
265 | 40 Amp Double pole Isolator |
266 | 32 Amp Triple pole MCB |
267 | 63 Amp Four pole Isolator |
268 | 100 Amp Four pole Isolator |
269 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
270 | 4 way (4 + 12), Double door |
271 | 6 Way (4 + 18 ), Double Door |
272 | Supplying and fixing 20 A, 240 V, SPN industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP , MCB, in sheet steel enclosure, on surface or in recess, with cained metal cover for the socket outletadnd complete connections, testing and commissioning etc. as required. (M/S Havells Model : DHDPBDP016/ SS make) |
273 | Earthing |
274 | Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
275 | Providing and fixing 25 mm X 5 mm G.Istrip on surface or in recess for connections etc. as required. |
276 | Providing and fixing earth bus of 25 mm x 5 mm copper strip on surface for connections etc. as required. |
277 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia i/c accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as reqd. |
278 | Providing and layingG.I. pipe dia 40 mmfrom earth electrodeexcavation and re-filling as reqd. |
279 | Providing and fixing 8 SWG dia Copper wire on surface or in recess for loop earthing as required. |
280 | Fittings & Fans |
281 | Supplying fitting and fixing of LED PANEL LIGHTING surface or wall mounted with all anecessary accessories. (a) 2x2 (595x595x70) mm recess mounting luminaire suitable for ceiling. (iii) 42 W |
282 | (SURFACE) LED flat panel for Surface mounting |
283 | (i) 1X1 15 W (300x300x70) mm |
284 | (ii) 2x2 42 W (600x600x70)mm |
285 | (iii) 4x1 42 W (1200x300x70)mm |
286 | Supplying of LED Batten fitting surface mounted complete with drivers and all other accessories suitable for operation on 220 V 50 HZ single phase ac supply i/c connections etc complete as rqd. (M/s Phi;lipsor SS make ) |
287 | Model : BN100 C LED 40 S-6500 |
288 | Supplying fitting and fixing of LED MIRROR LIGHT surface or wall mounted with all necessary. SITC of 1x9 Watt LED Mirror light fixure wall mounted with electronic high efficiency electronic driver as complete as reqd. (PHILIPS Make : Cat No. 31083 Shell line or equivalent). (a) LED Mirror Lights |
289 | Supply, Installation, Testing & Commissioning of LED Step Light 15 Watt PHILIPS make Cat No.BWG150 LED50W PSU 220-240V IP67 7043 or equivalent. (a) LED STEP Lights |
290 | Supply, Installation, Testing & Commissioning of self contained emergency light units 1x3 Watt double sided for wall/ ceiling mounting with suspension / mounting kit, inbuilt standby battery ( for 2 hours backup)and batery charger etc in suitable enclosure Make BAJAJ Cat No. BESL 03 LED DSD Green or equivalent.att PHILIPS make Cat No.BWG150 LED50W PSU 220-240V IP67 7043 or equivalent. (a) 1 x 3 Watt Double sided |
291 | Supplying and fixing of of LED Surface Recessmounted slim profile downlights fitting complete with drivers and all other accessories suitable for operation on 220 V 50 HZ single phase ac supply i/c connections etc complete as rqd. (M/s Philipsor SS make ) |
292 | Model : SP 250C 20 S-6500 PSU |
293 | Arch Space Pro for aesthetic Model : SP321P LED 15S-5700 PSU ( Office use) |
294 | SF of 6.5W LED Bulkhead fitting with IP65 Protection on outdoor wall i/c connection etc complete as reqd. ( Type -WT140W LED7S NW PSU S1 PC of Philipsor SS make) |
295 | Supply, fitting and fixing of deluxe type Chandelier made of brass fancy type longitudinal glass rod or chain as pendent ring LED bulb etc complete with all accessories. (a) 6-12 lamp Deluxe medium chandelier fitting |
296 | Supplying and fitting of ceiling fan AC operated type 220/250 Volt, complete with 3 Nos of baldes down rid canopy hanging sackle & 30 mm length of down rod supplied with the fan by the dealer but the extra length will be charged @ Rs. 25.00/ mtrs. |
297 | AC Ceiling Fan "600" mm sweep |
298 | AC Ceiling Fan "1200" mm sweep |
299 | AC Ceiling Fan "1400" mm sweep |
300 | Supplying, fitting & fixing of WAll/ Table fan with all necessary attachments and Accessories as reqd. |
301 | 400 mm wall Fan |
302 | Supplying fitting & fixing of exhaust fan double bearing self lubricating type single phase 50 Hz 250 V AC operated complete with supporting frame, fan blades, nuts and bolts and other petty accessories as reqd. |
303 | Domestic Exhaust fan (iii)200 mm |
304 | Metal Exhaust Fan 300mm |
305 | Heavy Duty Exhaust Fan 450 mm (18"x1400RPM) |
306 | OUTDOOR LIGHTS & CABLES |
307 | Providing laying connection testing & commissioning of the following sizes 1100V PVC/XLPE Armoured cables with Aluminium conductor as per ISI code in bracket, trenches, M.S cable rods adnd i/c the cost of digging of trnches sand a=cushioning with laying etc and refilling the same in layeers or by supporting them in walls and all other accessories as reqd. |
308 | With 3.5 core 50.0 sq.mm |
309 | With 3.5 core 120.0 sq.mm |
310 | Supplying and laying of following PVC insulated and sheathed / XLPE Al. conductor, armoured Power cable of 1.1KV grade as reqd. (Polycab /Havells make) |
311 | 2 x 6.0 sq.mm. |
312 | S/M end termination with brass compression gland and Al. lugs for below size of cable of 1.1 kv grade as reqd. |
313 | 2x 6.0 sq.mm ( 19 mm) |
314 | 3.5 core 50.0 sq.mm ( 35 mm) |
315 | 3.5 core 120.0 sq.mm (45 mm) |
316 | S/F SMC sheet junction box having concealed side hinges of size 200 x 140 x 95 mm deep i/c one no. 6A SP MCB, 3 way stud terminal, din channel etc. complete as reqd. ( Sintex or SS of Hensel make ) |
317 | Supplying, Installation, Testing & Commisssioning of 7 Mtr High hot dip Galvanised Octagonal Pole with 130mm A/F, top 70 mm A/F made up of 3 mm thick HT plate and 220*220*12 mm base plate and 1000 mm long single arm bracket complete with 4 nos M24 x700 mm long foundation bolts, RCC foundation etc as complete as reqd. |
318 | Supplying fitting and fixing of STREET LIGHT surface or wall mounted with all necessary accessories. |
319 | LED STREET light made up of pressure die cast aluminium housing swith high power LED as lighting source and lens embedded PC cover having protection and impact resistance with 10KV built -in surgge Protection device. (i) 80 W suitable for Pole dia @54 mm (Max) |
320 | Supplying fitting and fixing of FLOOD LIGHT surface or wall mounted with all necessary accessories. (a) FLOOD light suitable for high mast application, high lighting architetural facade and general purpose lighting (i) 180 Watt |
321 | Supplying, fitting & fixing of LANDSCAPE LIGHTS surface or wall mounted with all necessary accessories. |
322 | Post Top, energy saving , environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. (iv) 50 W suitable for pole dia @76 mm |
323 | Decorative UP_DOWN luminaire with wall surface mounting using COB LED as light source.(i) 15 W |
324 | Decorative spike light using COB LED as light source. (i) 9 W |
325 | Aiesthetically designed die-casrt aluminium landscape luminaire for downward lighting with high power LED as light source. (i) 16 W |
326 | SITC of LED Bollard robustly designed IP65/ 1K10for garden designingi/c connection as complete as reqd. ( M/S PHILIPSModel No: BCP150 LED 150/WW) |
327 | WATER HEATER (GEYSER ) |
328 | Supplying, fitting & fixing of Water Heater (Geyser) of 1.5 KW/ 3.0Kw with pressure release value i/c all necessary accessories as reqd. |
329 | 15 Litrs Capacity |
330 | 25 litres capacity |
331 | 50 litres capacity |
332 | PUMP & ACCESSORIES |
333 | Supplying, fitting & fixing complete 100 mm Bore Well Submersible Pumps 3 Ph (water Filled) or similar. |
334 | 5 HP (one spare) |
335 | SITC of 01 number 5.0HP, Three phase , mono Block with Sync. Speed -2870 rpme water pump, Size (mm) SUC. X DEL. 50 X 40, suitable for 415 Volt, 50Hz AC supply "F" Classinsulationcapable of discharging 7.8to 3.0 LPS with head range of 40to 68 metre complete etc as reqd. (M/S KIRLOSKAR BROTHERS LTD make, Model : KDS 550++or SS. make). (Building- 1 No, Spare - 1 No, Fire Fighting - 1 No.) |
336 | S/F of three phase DOL Starter Panel for 5.0HPSubmersible Pump with 3 Phase Auto/Manual DOL 5.0 HP HD OLR(9-14)A Motor Starter Panel 380-415V AC onlin Contractor rating of 12 and overload Realy rating of 7.0 to 10.0Amps in sheet enclosure on suitable size of MS board suitable for 415 Volts 50 Hz supply i/c connection testing commissioning etc. as reqd. (M/S HavellsModel -IHPDOLL*E/SS make) |
337 | Supplying, fitting & fixing of 3 CORE Flat Submersible cables 1100V. (a) 2.5 sq.mm. |
338 | Supplying and Fixing of 40 mm cPVC pipe as reqd. (M/S Ashirbad/ SS mae) |
339 | Providing, laying , ttesting a & commissioning of "B" Class heavy duty G.I. Pipe conforming to IS 1239 i/c welding, fitting like elbows , tees, flanges, tapers, nuts, bolts, gaskets etc and fixing the pipe on the wall/ ceiling with suitable clamp/ support frame and painting with two or more coats of synthetic enamel paint of reqd shade complete as reqd. |
340 | 32 mm dia |
341 | 40 mm dia |
342 | 50 mm dia |
343 | Supplying and fixing of following accessories for pipe line as reqd. (M/s Zeloto). (a) Bronze Horizontal Check Valve (screwed) 50 mm |
344 | Cubical Panel |
345 | Fabricating, supplying and fixing of compartmentalized type dust & vermin prooffloor / wall mounting, front openable, cubical panel suitable for accomodating the following capacity switch gears and accessories for operation on 415 volts, 3 phase, 50 Hz AC supply system and fabricated out of 16 SWG MS sheet having minimum depth of 300mm i/c cutting, welding, painting & sign writing etc. and with locking arrangement, required number of cable entries, Cable alley, earthing terminals i/c providing and fixing 100 Amps 4 strip aluminium busbar - 2 set provinding & fixing required number of neutral links of suitable capacity and making interconnections of following with required capacity for main incomer, outgoings switchgears / SPN MCB connections (solid inter connections shall be provided above 100Amp switchgears), providing & fixing 3 Nos. (Red, Yellow, Blue) LED indicators, providing & fixing digital VAF meter connecting to incoming, minor civil works and making good the damages etc. as per specification complete as reqd. (But without Switchgears) |
346 | (Note: The drawing should be got approvedby the ENC before fabrication) |
347 | Space for accomodating 200 Amp FP MCCB 30 KA (As incomer) - 1 No. |
348 | Space for accomodating125 Amp FP MCCB 18 KA (As outgoing)- 3 No. |
349 | Space for accomodating63 Amp FP MCCB 18 KA (As outgoing)- 2 No. |
350 | Space for accomodating 32 Amp DP MCCB 25 KA (As outgoing) - 2 No. |
351 | Space for accomodating 200 Amp FP ON load Change Over Switch - 1 No. |
352 | Space for accomodating 40/63 Amp DP MCB/Isolator (As outgoings) - 3 No |
353 | Supplying and fixing of 200 Amp 4 pole ON load changeover switch (open execution type) in the existing cubical panel complete with connections, testing and commissioning as required.(Make: HavellsCat.no.IHCNFO 0200) |
354 | Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
355 | 200 Amp 25 KA FPMCCB(Cat.no IHLGHFO125#) |
356 | 125 Amp 25 KA FPMCCB(Cat.no IHLGHFO125#) |
357 | 63 Amp 25 KA FPMCCB(Cat.no IHLGHFO125#) |
358 | 32 Amp 18 KA FPMCCB(Cat.no.CM90518OOFO) |
359 | 32 Amp 25 KA DPMCCB(Cat.no.EM90982OOEO) |
360 | Providing and fixing following accesories for MCCB includingmaking connections, etc. as required. |
361 | Rotary handle for 200 Amp 35 KA FPMCCB(Cat.no. CM97896OOOO) |
362 | Rotary handle for 125 Amp 25 KA FPMCCB(Cat.no. CM97896OOOO) |
363 | Rotary handle for 63 Amp 25 KA FPMCCB(Cat.no. CM97896OOOO) |
364 | Rotary handle for 32 Amp 18 KA FPMCCB(Cat.no. CM97896OOOO) |
365 | Rotary handle for 32 Amp 25 KA DPMCCB(Cat.no. EM90970OOOO) |
366 | Terminal spreader for 63 Amp 30 KA FPMCCB |
367 | Terminal spreader for 32 Amp 18 KA FPMCCB |
368 | Terminal spreader for 32 Amp 25 KA DPMCCB |
369 | FIRE DETECTION AND ALARM SYSTEM |
370 | SITC of wall / floor cum wall/ 19" rack mountable micro processor based, interactive modular intelligent and addressable networkable programmable from PC or on board keypad/ touch screen, expandable upto 4 loops main fire detection control & indication panel complete wiht CPU, LCD display, operaion terminal, detectiomn loops control loops power supply modle, nbattery charger dry cell maintenance free battery of suitable capacity with in built battery charger, housing complete as reqd. The panel ahall be loaded with auto dialler for triggering alarm signalsvia SMS on atleast 10 nos of mobile phones and 10 nos of direct telephone numbers as assigned and programmed for make. (Make : ESSER, GENT/APOLO/SYSTEM SENSOR) |
371 | Supplying of intelligent, addressable fixed temperature heat detector (complete assembly) with inbuilt microprocessor, memory and decision algorithm, CPU failure mode staus indicator i/c imported interchangeable base unit with builtin loop isolator etc (Make : ESSER, GENT/APOLO/SYSTEM SENSOR) |
372 | Supplying of intelligent, addressable Optical smoke detector cum flasher with inbuilt microprocessor, memory and decision algorithm, CPU failure mode status indicatorwith builtin loop isolator and standard detector bse with NO DIP/ ROTARY or Mechanical address switch but soft programmableor alternatively LAser type spot multisensing detector (Make : ESSER, GENT/APOLO/SYSTEM SENSOR) |
373 | Supplying of wall mounted addressable type microprocessor based manual call point with built in loop isolator and all accessories complete s rqd.(Make : ESSER, GENT/APOLO/SYSTEM SENSOR) |
374 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
375 | SITC of PVC/XLPE Armoured cables with copper conductor 1100V, Grade of the following sizes along wall etc in ground as reqd. (a) 1.5 sq.mm 2 core cable |
376 | Supplying Installation fixing ABC DRY CHEMICAL POWDER Fire Extinguisher of 5.0 Kg Trolley mounted confirming to IS:2171 and CO2 cartridge confirming to IS:4947 Powder confirming to IS: 4308. |
377 | Supplying Installation fixing of MECHANICAL FOAM(AFFF) Fire Extinguisher of 9.0 Ltrs confirming to IS :10204 and CO2 Cartridge confirming to IS:4947 (AFFF) Confirming to IS:4989 |
378 | Supplying, Installation Fixing of CO2 based Fire Extinguisher (squeeze grip type) of 4.5 Kg capacity. |
379 | LIGHTNING CONDUCTOR |
380 | Supplying , fitting & fixing of Copper lightningArrester with 5 Nos Finger at the top & copper base plate at the bottom complete. (a) With 3 ft High Copper rod |
381 | Providing and fixing 25 mm X 5 mm G.Istrip on surface or in recess for connections etc. as required. |
382 | AIRCONDITION and ACCESSORIES |
383 | Supplying, fitting & fixing of A.C with heating and cooling facility i/c supply of all necessary accesssorries as reqd for insrtallation of Air Conditioner (AC). |
384 | 1.5 Ton capacity |
385 | 2.0 Ton Capacity |
386 | Supplying and fixing of Extra for refrigirant pipe line including insulating the surface as reqd. |
387 | 3/4" pipe |
388 | 5/8" pipe |
389 | Supplying and fixing of Drain pipes as reqd. |
390 | Providing and fixing ofStarter for AC unit( 2 Module) on surface or in recesscomplete with connections, testingetc as reqd.(M/s Havells /Crabtree/Anchor or similar superior make) |
391 | Supplying and installation of Outdoor stand for split AC as reqd. |
392 | Supplying and fixing 4.0 KVA Automatic Voltage Stabilizer with Input range 0f 140-280 Volts and Output range of 200- 240 Volts, 50 Hz with auto cut off facility as reqd. |
393 | HYDRANT SYSTEM WITH PUMP HOUSE |
394 | PITC of "C" class heavy duty MS pipe confirming to IS3589/IS 1239 i/c welding , fitting like elbows, tess, flanges, tapers, nuts bolts, gaskets etc and fixing the pipe on the wall/ ceiling with suitable clamp/ support frame and painting wth two coats or more coats of synthetic enamel paint of rreqd shade complete as reqd. |
395 | 150 mm dia |
396 | 100 mm dia |
397 | 80 mm dia |
398 | 40 mm dia |
399 | 25 mm dia |
400 | Supply and installation of hydrant valve including flange, gusket, nut bolt complete as reqd. |
401 | Supply and installation of first Aid Hose Reel Drum complete with fittingsas reqd. |
402 | Supply and installation of 63 mm dia 15 mtr long RRL hose including male female couplingas reqd. |
403 | Supply and installation of single door MS hose cabinate as reqd. |
404 | Supply and installation of short size branch pipe as reqd. |
405 | Supply and installation of two way type fire brigade inlet connection complete with all fittings as reqd. |
406 | Supply and installation of ball valve complete with all fittingsas reqd. |
407 | Supply and installation of CI butterfly valve complete with all fittings as reqd. |
408 | 100 mm dia |
409 | 80 mm dia |
410 | Supply and installation of Single plate type CI Non Return Valve Including all fittings as reqd. |
411 | 100 mm dia |
412 | 80 mm dia |
413 | Supply and installation of AIR Release Valve complete with all fittings as reqd. |
414 | Supply and installation of pressure switch including ball valve & fitings as reqd. |
415 | Supply and installation of pressure gauge including ball valve and fittings as reqd. |
416 | SITC of Electric driven Main Fire Pump suitable for automatic operation and consisting of followig complete in all respect as reqd. |
417 | (a) Horizontal type multistage centrifugal split casing pump of casr iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520. |
418 | (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous sped 1500 RPM suitable for operation on 415 Volt, 3 phse , 50 Hz, AC supply with IP55 protection for enclosure, horizontal foot mounted type wth ClassF insulation, confirming to IS-325 |
419 | (c ) M.S fabricated common base plate, coupling coupling guard, foundation bolts etc as reqd. |
420 | (d) Suitable for cement concrete foundation duly plastered with anti vibration pads. |
421 | 1620 lmp at 56 m Head |
422 | SITC of Electric driven Pressurisation Pump suitable for automatic operation and consisting of followig complete in all respect as reqd. (Jockey Pump) |
423 | (a) Horizontal type multistage centrifugal pump of casr iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520. |
424 | (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous sped 1500 RPM suitable for operation on 415 Volt, 3 phse , 50 Hz, AC supply with IP55 protection for enclosure, horizontal foot mounted type wth ClassF insulation, confirming to IS-325 |
425 | (c ) M.S fabricated common base plate, coupling coupling guard, foundation bolts etc as reqd. |
426 | (d) Suitable for cement concrete foundation duly plastered with anti vibration pads. |
427 | 300 lmp at 56 m Head |
428 | CONTROL PANEL |
429 | Fabrication, supply, installation testing & commissioning of Electrical contol panel of cubical construction, floor mounted type, fabricated out of 2 m thick CRCA sheet compartmentalised with hinged lockable doors, sut and vermin proof, powder coated of approved shade afger 7 tank treatment process, cable alley, inter connection with suitable asize of copper conductor cable/ solid copper strip, having switchgear and accessories, mounting and internal wiring, earth terminal, numbering etc, complete in all respect, suitable for main fire pump, pressurisation pump & diesel pumpo set complete as per CPWD specification with following incoming and Outgoing suitable for operation on 415 V, 3 phase, 50 Hz AC supply with enclosure protection class IP 42 as reqd. |
430 | (a) INCOMING |
431 | 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500 V, with selector switch Digital Ameter (0-25 A) with selectro switch & CT"s etc, LED type RYB phase indicator lamps, ON, OFF trip indicating lamps Set of Copper Bus bar 300 A |
432 | (b) OUTGOING |
433 | Main Fire Pump:-125 A, 50 kA, TPN MCCB, Ics=100%, Icu, with fully automaticStar/ Delta startersuitable for 60 HP pump with overload protection, currrent sensing typersingle phase preventor complete with all accessories and internal wiring reqd. for automatic operation, selector switchfor local/ remote / auto/ manual/OFF operation. |
434 | Jockey Pump; - 63 A, 50kA TPN MCCB , Ics=100%, Icu, with suitable HP fully automaticStar/ Delta starter with currrent sensing typer single phase preventor complete with all accessories and internal wiring reqd. for automatic operation, selector switchfor local/ remote / auto/ manual/OFF operation. |
435 | Supply and installation of CI Foot valeas reqd. |
436 | 100 mm dia |
437 | 80 mm dia |
438 | Supply and installation of Wrapping Coating with black bitumin paint for underground pipe line as reqd. |
439 | SPRINKLER SYSTEM |
440 | Supply and installation of pendent type 68 " C sprinkler head including fittingsas reqd. |
441 | Supply and installation of CI butterfly valve complete with all fittingsas reqd. (a) 80 mm dia |
442 | PATHWAYS |
443 | Excavation in soil in Hilly area by mechanical means including cutting and trimming of side slopes and disposal of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per drawing and Technical Specification Clause 1603.1 Ordinary Soil |
444 | Construction of granular sub-base by providing well graded material, mixing in mechanical mix plant at OMC carriage of mixed material to work site upto a lead of 1000 m, spreading in uniform layers with motor grader on prepared surface and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material. |
445 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80-100 kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc. as per Tables 400.11 & 400.12 and Technical Specification Clause 406. |
446 | Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub-base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including leveling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridges/culverts and construction joints, admixtures as approved, curing of concrete slabs for 14-days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501. |
447 | RETAINING WALL |
448 | Earth work in excavation by manuav mechanical means (Hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 in in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 in and lift up to 1.5 in, as directed by Engineer-in-charge (a) All kinds of soil. |
449 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a)1 :4:8 (1 Cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) |
450 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) 1:3:6(1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) |
451 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping Of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per ls: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineerin-charge. (b) All works above plinth level up to first floor. |
452 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, and horage etc. and no measurement for the same is required) (a) Thermo-Mechanically Treated bars |
453 | Centerlng and shutterlng lncludlng struttlng, propplng etc. and removal of form for all heights complcte and as directed by Engineer in charge. (a)Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
454 | (d) Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
455 | Providing weep holes in brick masonry/stone masonry, Plain/reinforced concrete abutments, wing walls, return walls with 100 mm dia AC pipe extending through the full width of the structures with slope of 1 (V) : 20 (H) towards drawing face complete as per drawing and Technical Specification Clauses 614, 709, 1204.3.7. |
456 | FURNITURE |
457 | DOUBLE BED OF SIZE 6"X6"6" |
458 | SINGLE SEATER SOFA |
459 | THREESEATER SOFA |
460 | BALCONY SEATS |
461 | WARDROBE/STORAGE |
462 | NIGHT STAND (BEDSIDE) |
463 | TELEVISION STAND |
464 | SINGLE SEATER SOFA |
465 | CENTR TABLE FOR LOBBY |
466 | THREESEATER SOFA |
467 | OFFICE CHAIRS |
468 | OFFICE TABLE |
469 | RECEPTION TABLE |
470 | 1 DINING TABLE & 4 CHAIRS |
471 | 3 DINING TABLE & 6 CHAIRS |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy