Tender For Repair/ Maint Of Summer/Winter Appliances In Area Yard I Of Age E/M Under Ge (East) Lucknow, lucknow-Uttar Pradesh

Military Engineer Services-MES has published Tender For Repair/ Maint Of Summer/Winter Appliances In Area Yard I Of Age E/M Under Ge (East) Lucknow. Submission Date for this Tender is 22-07-2023. Air Conditioner Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38377235
Corrigendum : Tender For Repair/ Maint Of Summer/Winter Appliances In Area Yard I Of Age E/M Under Ge (East) Lucknow
Open Tender
Indian
Uttar Pradesh
lucknow
22-07-2023

Tender Details

Repair/ Maint Of Summer/Winter Appliances In Area Yard I Of Age E/M Under Ge (East) Lucknow

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work: REPAIR/ MAINT OF SUMMER/WINTER APPLIANCES IN AREA YARD-I OF AGE E/M UNDER GE (EAST) LUCKNOW.
Sl. No. Item Description
1Taking down the Geyser of any make size and type horizontal orvertical from Site for repairs/overhauling/replacement of unserviceable partsincluding replacement of old nuts and bolts with washers heavy duty includingdisconnection of electric supply, water supply lines and refixing the Geyser in the serviceable condition after assembling, testing and reconnecting the electric/ water supply line complete all as specified and directed. Note:-Replacement of unserviceable parts of old Geyser shall be measured and paid separately under respective item here in after except bolt, nuts and washers.
2Supply and fix in replacementof unserviceable heating element 2.0 KW suitable for (ISI marked) for any make and type of geyser complete all as specified and directed. Make:- Racold/Bajaj/Usha/Theeta
3Supply and fix in replacement ofthermostat(ISI Marked) suitable for any type and capacity of geyser complete all as specified and directed. Make:- Racold/Bajaj/Usha
4Supply and fix in replacement of unserviceable indicating lampsred and green colour for Geysers of any make and capacity complete all as specified and directed.
5Supply and fix in replacement of unserviceable door assembly ISI marked comprising of inlet and outlet thermostate, housing with gasketwith bolts, nuts, washers, screws of packing suitable for any type and make of geyser complete all as specified and directed.Make:- Racold/Bajaj/Usha
6M&L for repairing of leakage of inner copper/steeltank ofany type /capacity and make of Geyser by brazingincluding necessary dentingetc complete all as specified and directed.
7Supply and fix in replacement of unserviceable plug top 3 pin 15 Amp complete all as specified and directed. Make- Anchor/ SSK or equivalent as approved by GE .
8Supply and fix in replacement ofunserviceable 3 core copper flexible round cable 40/0.0076 size complete all as specified and directed.
9S&F in replacement of stainless steelinner tank 25 Ltrs capacityas per existing gauge for Geyserscomplete all as specified and directed. Make:- Racold/Venus/ Dasspass
10S&F in replacement stainless steelinner tank 35 to 50 Ltrs capacityas per existing gauge for Geyserscomplete all as specified and directed. Make:- Racold/Venus/ Dasspass
11S&F in replacement of 450mm long copper connection complete & both side nut with rubber washer suitable for any capacity of Geysercomplete all as specified and directed.
12S&F in replacement of 600mm long copper connection with both side nut & rubber washer suitable for any capacity of Geysercomplete all as specified and directed.
13Taking out old U/S insulated pipe and supply & fix 15mm bore hot water pipe duly insulated with glass wool and aluminium cladding galvanised iron tubing medium grade with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid on walls through proper clamps complete all as specified and directed.
14Taking out old U/S pipe and supply, laying, jointing & testing galvanised iron tubing medium grade of 20mm bore with all fittings such as bends, elbows, tees, sockets, reducers, unions etc as required at site laid on walls through proper clamps complete all as specified and directed
15S&F MCB SP 5 to 32 Amps, 240 Volts, breaking capacity 10 kA "C" curve complete all as specified and directed.
16S&F factory made Sheet metal enclosure for MCB one way complete all as specified and directed.
17S&F metallic topsuitable for 20 Amp capacity plug & socket complete all as specified and directed.
18S&F metallic plug base suitable for 20 Amp capacity plug & socket complete all as specified and directed.
19S&F Switch socket combination 5 pin 15 Amps multipurpose type complete all as specified and directed.
20M&L for painting of outer tank of Geyser with applying two coats ofwhite synthetic enamel paintincluding writing MES No. with black paint complete all as specified and directed.
21S&F in replacement of brass Safety Valve heavy duty ISI marked of Geyser suitable for 15 mm bore of pipecomplete all as specified and directed.
22S&F 450 mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser complete all as specified and directed.
23S&F 600mm long PVC pipe connection hot series with both side nut with rubber washer suitable for any capacity of Geyser complete all as specified and directed.
24Taking down Ceiling fan/Exhaust fan of any size , any make, sealing cable ends, dismantling blades in case of ceiling fan and removing fan and blades to E/M store yard I for repair & hanging / fixing of the same after repair and connecting up complete all as specified and directed.
25M&L for repair and overhauling of Ceiling fan/ Exhaust fan/ Cabin fan/ Wall mounting fan/ Table fan/ Pedastal fan of any size by oiling/ greasing and reassembling the fan with new split pin, check nut, locking nut, washer, holder clip & connector. Testing and refixing of same fan shall be made to the entire satisfaction of Engineer-in-charge. Note: (i) Repair work will be carried out at MES workshop/at site/ Users Residence as directed. Material required Ball bearing and Condenser etc for replacement of items will be measured and paid separately.
26S&F in replacement of ball bearing of size 6201/6202/6203 complete all as specified and directed. Make - NBC/TATA/SKFor equivalent as approved by GE .
27S&F in replacement of capacitor 2.5 MFdfor ceiling fan of any size and exhaust fan of size 300/230mm cabin fan any Sweep complete all as specified and directed. Make:- Epcos/Usha or equivalent as approved by GE .
28S&F in replacement of capacitor 4 MFd for exhaust fan of size 450 mm/380 mm complete all as specified and directed. Make - USHA / EPCOSor equivalent as approved by GE .
29S&F in replacement of unserviceable fan regulator electronic rotary step type 110 W (Socket in size 2 Module) suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed. Make - BAJAJ /USHA /ORIENT /ANCHOR.
30S&F in replacement of unserviceable fan regulator electronic rotary step type 110 W (Switch in size 1 Module) suitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed. Make - BAJAJ /USHA /ORIENT /ANCHOR.
31S&F in replacement of unserviceable fan regulator electronic rotary step type 110 W (Socket in size 2 Module) modular typesuitable for 1200/1400 mm sweep ceiling fan complete all as specified and directed. Make - BAJAJ /USHA /ORIENT /ANCHOR.
32Rewinding of Ceiling/ Exhaust/ Cabin fans and pedestal fans comprising of followings :- a) Rewinding of stator with supper enameled copper wire (gauge of wire shall be same as provided by the manufacturer) including varnishing the new winding wire with quick dry varnish properly. b) Replacement of defective worn out bush where required ( Note:-ball bearing, capacitor will be measured and paid separately). c) Oiling/greasing and reassembling the fans with new split pin, check nut, locking bolt, washer, holder clip and connector including providing new twisted twin core flexible copper cable of size 23/0.0076 of 1 meter length. d) Testing of repaired fan shall be carried out in the yard of AGE E/M (East) to the entire satisfaction of the Engr-in-Charge. Note: Rewinding shall be carried out in Yard-I,Painting ofFans deemed to be included in respective Item. 32.01 Ceiling fan of 1200 mm Sweep
33Ceiling fan of 1400 mm Sweep
34Exhaust fan 450 mm (18") to 600 mm (24") Sweep
35Exhaust fan 380 mm (15") Sweep
36Exhaust fan 300 mm (12") Sweep
37Exhaust fan 230 mm (9") Sweep
38Wallfan 400 mm Sweep
39Supply and fixing blade set (set of three) for any type/make of ceiling fan 1200 mm Sweep complete all as specified and directed.
40Supply and fixing blade set (set of three) for any type/make of ceiling fan 1400 mm Sweep complete all as Specified and directed
41Supply and fixing Blade Set with frame & four legs of fan with coupling for 450 mm (18") sweep exhaust fan complete all as Specified and directed.
42Supply and fixing Blade Set with frame & four legs of fan with coupling for 380 mm (15") Sweep exhaust fan complete all as Specified and directed.
43Supply and fixing Blade Set with frame & four legs of fan with coupling for 300 mm (12") Sweep exhaust fan complete all as Specified and directed.
44Supply and fixing Blade Set with frame & four legs of fan with coupling for 230 mm (9") Sweep exhaust fan complete all as Specified and directed.
45Supply and fixing Blade set of wall fan suitable for 400 mm sweep complete all as specified and directed.
46S&F twisted twin core flexible copper cable of size 23/0.0076 complete all as specified and directed.
47M &L for Spray painting of fan with one coat of super enamel white paint after cleaning of body and blades, down rods, with detergent powder and writing MES Nos with black paint complete all as specified and directed.
48S&F in replacement of unserviceable hanging clamp for ceiling fan of any type complete with rubberreel, split pin, bolts, nut and washer complete all as specified and directed.
49S&F in replacement of worn out/defective roter shaft of ceiling fan, exhaust fan, cabin fan of any make and size complete all as specified and directed.
50S&F ceiling fan canopy set of two complete all as specified and directed.
51Taking down U/S Ceiling fan/Exhaust fan/wall fan/PVC air freshner of any Size/Type/Model and handover to MES Store E/M Yard-I for BER process.
52S&F ofceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make:- Bajaj/ Havells/ Crompton/ Usha
53S&F ofceiling fans complete with blades, down rods and accessories, 230 V, 1400 mm sweep, min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Make:- Bajaj/ Havells/ Crompton/ Usha
54S&F of exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 300 mm sweep 1400 RPM ISI marked,and making connection with twisted copper flexible wire 23/0.076 mm complete all as specified and directed.Make:- Bajaj/ Havells/ Crompton/ Usha
55S&F of exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 230 mm sweep 1400 RPM ISI markedand making connection with twisted copper flexible wire 23/0.076 mm complete all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
56S&F of exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 380 mm sweep 1400 RPM ISI markedand making connection with twisted copper flexible wire 23/0.076 mm complete all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
57S&F of exhaust fans single phase 230/240 Volts heavy duty metalicbody of size 450 mm sweep 1400 RPM ISI markedand making connection with twisted copper flexible wire 23/0.076 mm complete all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
58S&F of wall fan of 300 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 Cum/minwith all accessories complete all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
59S&F of wall fan of 400 mm sweep, 220 - 240 volts, AC, 50 Hz 1330 RPM, 55 Watts power input, air delivery 65 Cum/minwith all accessories complete all as specified and directed. Make:- Bajaj/Havells/Crompton/Usha
60S&F ofPVC air freshner 200 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm complete all as specified and directed. Make:- Bajaj/ Havells/ Crompton/ Usha
61S&F of PVC air freshner 250 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm complete all as specified and directed. Make:- Bajaj/ Havells/ Crompton/ Usha
62S&F of PVC air freshner 300 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm complete all as specified and directed. Make:- Bajaj/ Havells/ Crompton/ Usha
63S&F in replacement ofPressure pump motor, single phase, 230 Volts, 50 Hz, of capacity 1.0 HP complete ofpressure pumps & systems Model No-100B Pressurejet including making connections complete all as per specified and directed. Make: Crompton Cat No-Model No-CFCHMor equivalent as approved by GE .
64Taking down/ dismantling of unserviceable pressure pump of any capacity for rewinding , overhaulingof pressure pump complete and refixing, testing and running complete all as specified and directed.
65S&F energy saving ceiling fan of 1200 mm sweep of 330-370 RPM, 220-240 volts, AC, 50 Hz, ISI marked with five star rating including hanging with the help of fan hook, down rod up to 04 feet and connecting up with provn of 3 core copper flexible cable of size 1.5 sqmm from ceiling rose to fan complete all as specified and directed.Make : Havells, Model: ES-50 Premium or Usha, Model: Energia Star ISI or Crompton Greaves, Model: Empower 50
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail