| 1 | Cost of Material |
| 2 | 100.98.469 : Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 80mm. |
| 3 | 100.98.470 : Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 100mm. |
| 4 | 100.98.472 : Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.0, Size 150mm. |
| 5 | 18.12.5 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work40 mm dia nominal bore |
| 6 | 18.12.6 : Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work50 mm dia nominal bore |
| 7 | 18.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore |
| 8 | 18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 9 | 18.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore |
| 10 | 100.98.216 : Supply of uPVC Pipe, IS 4985:2000 , 6kg/cm2, 160mm Dia. |
| 11 | 100.98.214 : Supply of uPVC Pipe, IS 4985:2000 , 6kg/cm2, 110mm Dia. |
| 12 | 100.98.213 : Supply of uPVC Pipe, IS 4985:2000 , 6kg/cm2, 90mm Dia. |
| 13 | 100.98.212 : Supply of uPVC Pipe, IS 4985:2000 , 6kg/cm2, 75mm Dia.. |
| 14 | 100.98.210 : Supply of uPVC Pipe, IS 4985:2000 , 6kg/cm2, 50mm Dia. |
| 15 | Laying Charge |
| 16 | 100.1.1 : Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil (Ref. Item No. 2.10.1 of DSR) |
| 17 | 100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes. |
| 18 | 100.9.7 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials).75 mm nominal outer dia pipes. |
| 19 | 100.9.8 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials). 90 mm nominal outer dia pipes.\" |
| 20 | 100.9.9 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials).110 mm nominal outer dia pipes. |
| 21 | 100.9.11 : Laying UPVC pipesof class 2 to class 6 andspecials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure(excluding cost of pipes and specials).160 mm nominal outer dia pipes. |
| 22 | 100.31.1.1 : \"Conveying and fixing C.I. sluice valves (with cap)by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :80 mm diameter. Class I\"Observed Data derivedfrom item no.18.31.of DAR |
| 23 | 100.31.1.2 : \"Conveying and fixing C.I. sluice valves (with cap)by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :100 mm diameter. Class I\"Data derivedfrom item no.18.31.1.1of DAR |
| 24 | 100.31.1.4 : Conveying and fixing C.I. sluice valves (with cap)by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) :150 mm diameter. Class I\"Data derivedfrom item no.18.31.3.1 of DAR |
| 25 | 16.42 : Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete |
| 26 | 18.33.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 27 | 18.34.1 : Constructing masonry chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 28 | 18.35.1 : Constructing masonry chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grades stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 29 | 100.60.3.2.1 : Providing additional length of house connection pipe using25mm Indian Standard Class 6 uPVC pipe and specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of average cross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providing caution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roads etc., and as per the directions of the department officers. |
| 30 | 100.59.1 : Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 31 | Tank vertical pipe connection- Replacing Outlet Pipe |
| 32 | 100.37.6.2 : Fabricating MS flanges of diameter 150 mm using 12 mm thick MS plateincluding cost and conveyance charges of MS plate, all fabrication charges, charges of painting thesteel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 33 | 100.37.6.3 : Cutting 150mm (ID)MS pipes for making bends and other specialsby gas cutting including cost of gas, all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 34 | 100.37.6.4 : Welding150mm (ID) MS pipes for making bends and other specialsby gas/electric welding machine including cost of gas and welding rods ,all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 35 | 100.37.6.5 : Grinding cut and weld edges of 150mm (ID) MS pipes during fabrication work including all labour and hire charges of tools etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 36 | 100.53.1 : Washing OHSR/GLSR using brooms, brushes and bleaching powder by engaging coolies, scrubbing twice, washing and cleaning using fresh water, including side wall, floor slab and columns,disposing the the slurry / waste materilas away from the immediate premises and within the initial lead of 50m from the periphery of the tank, without causing any damage to the exististing strucutre and installations, charges including the operation of valves, conveyance and hire charges of tools and as per the direction of the department officers etc. complete. |
| 37 | od343622/2022_2023 : Dismantling and staking of existing verticaloutlet pipe 110mm PVC pipe for the overhead tank to the ground including cost of scaffolding etc. |
| 38 | 100.37.6.1 : Fabricating MS pipes of size 150mm (ID) using 8 mm thick MS plate including cost and conveyance charges of MS plate, all fabrication charges, charges of painting thesteel work with two or more coat deluxe multi surface paint to give an even shade over an under coat of primer etc. complete: For pipes fabricated with 8mm thick MS plates. |
| 39 | od344849/2022_2023 : Lifting, joining and fixing 150mm MS vertical outlet pipe from overhead tank to ground pipe including cost of all accessories nuts, bolts, rubber etc. |
| 40 | Pumping arrangement from Existing Well |
| 41 | 100.98.233 : Supply of uPVC Pipe, IS 4985:2000 , 10kg/cm2, 50mm Dia. |
| 42 | 18.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 43 | 100.9.5 : Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (excluding cost of pipes and specials) 50 mm nominal outer dia pipes. |
| 44 | od344475/2022_2023 : Supplying and fixing submersible pump using best quality ISI marked motor and pump of make Kirloskar, Crompton, CRI or equivalent, to suit the open well including the cost of starter, panel board Volt meter, ammeter, indicator lamp, non return valve, electrical cable etc., and all charges for conveyance of materials, labour charges and working with 2HP capacity :1.5Lps @30m head |
| 45 | Supply and Installation of Pump Set |
| 46 | od344504/2022_2023 : Supplying and fixing of centrifugal pump of make Kirloskar, Crompton, CRI or equivalent, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories includingcontrol panel, panel board Volt meter, ammeter, indicator lamp, non return valve, electrical cable etc and working with 3HP capacity :3LPS @35m head |
| 47 | od344505/2022_2023 : Supplying and fixing of centrifugal pump of make Kirloskar, Crompton, CRI or equivalent, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts, pressure guage and all accessories includingcontrol panel, panel board Volt meter, ammeter,indicator lamp,non return valve, electrical cable etc and working with 15HP capacity :10LPS @60m head |
| 48 | Repair and Painting of OH Tank |
| 49 | od345002/2022_2023 : Chipping Cleaning and removing the debris, cleaning the concrete surface and exposed reinforcement portion, removing the rust with Dr. Fixit rust remover, providing Dr. Fixit zinc rich primer, welding of steel reinforcement if required, painting with Dr. Fixit polymer mortar with curing compound, including all necessary arrangements, labors scaffolding, staging etc. |
| 50 | 13.111.1 : Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cementpaint surface |
| 51 | 14.72 : Providing and fixing double scaffolding system (cup lock type) on the exterior side, upto seven story hight made with 40 mm dia. M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staricase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required location with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in Charge.The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding. Note:- This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done . |