Supply, Installation And Commissioning Of Ultrasonic And Magnetic Flow Meters Along With Totalizer For Various Locations At 2X660mw Sstpp, Dongalia, Khandwa , Ultrasonic Type Flow Meters Of Following Specifications:Sensor: (1) Type: Ultrasonic Clamp On, 1 Channel , One Sensor Set(2 ) Measuring Principle: Transit Time Difference (3)Type Of Mounting - 2 Trasverses (4) Sensor Material :Anodizedal (Standard)(5) Sensor Holder Material : Ss 1.4308 /Cf-8 (6)Sensor Housing- Ss 1.4301/304(7) Strapping Bands/Bracket: Ss 1.4301/304 (8) Sensor Contact Surfaces: Chemically Safe Plastic Transmitter With Totalizer: (1) Accuracy:+/- 0.5 % Instrument Error, +/- 1.5 % Installation Error, Total Error +/-2 % Of Measured Value (2) Repeatability : < +/- 0.2 % (3) Converter: Die Cast Al(4)Power Supply: 85-250 Vac, 50 Hz(5)Calibration Range: As Per Max Flow In Area Of Application (6) Signal Cable: Double Shielded, 10 M(7) Display : Instantaneous Flow Rate With Cumulative Flow Totalizer (8) Output: 4-20 Ma Hart 7, Pulse O/P, Frequency O/P, Status O/P, Control O/P(9) Protection Class:Ip67/68 (10) Housing: Ai Diecast(11) Application:Hot/Cold Water (12) Zero Flow Detection, (13)Security : Temperproof , Ultrasonic Type Flow Meters For Following Areas: (1)Raw Water Inhouse-600 Nb Line Size-600 Nbqty-1No. (2) Raw Water Interconnection Line Between Ph-I & Ph-Ii,Line Size-600 Nb , Qty-1No(3) Plant Potable Line Size- 80 Nb ,Qty- 1 No. (4)Colony Potable Line Size-80 Nb Qty-1No. (5)Ct Makeup Line Size-100 Nbqty-1No. (6)Cw Blow Down To Ash Water Sump Line Size-80 Nb,Qty-1No. (7)Ptp Sludge To Ash Water Sump Line Size-200 Nb,Qty-1No. (8)Dm Transfer Pump Common Discharge Line Line Size-200 Nbqty-1 No. (9)Discharge Line Of Sludge Pit In Dm Plant-Ii(Waste Water Line For Deashing) , Line Size-300 Nb , Qty-1No.(10) Discharge Line Of Ows(Oily Water System), Line Size-150 Nb, Qty-1No. (11) Discharge Line-25 Nb Of (All 8 Nos) Sewage Treatment Plants To- (I) Hydrogen Plant (Ii) Silo (Iii) Switchyard (Iv) Primary Crusher (V) Secondery Crusher (Vi) Tp-1 (Vii)Ash Water Recovery (Viii) Dm Plant (Qty -8 Nos.(1 Qty Each Of I To Viii) (As Per Tender Schedule) , Electromagnetic Flowmeter For Ash Slurry Disposal Lines Inline Version. (1) Application:For Ash Slurry Measurement ,(2) Installation Length: Dvgw/Iso Conform. (3)Approval Non Hazardous Area (4) Design: Lap Joint Flange(5) Sensor Housing :Ss 304 , Liner : Natural Rubber (6)Process Connection: Cl.150, Carbon Steel, Lap(7) Electrodes: Ss 316 Brush Type , Meas. Electrode Only(8)Protection For Sensor : Ip68transmitter With Totalizer (1) Corrosion-Resistant Transmitter Version., Failure Modestop (2) Curr. Output :4...20 Ma Namur (3) Power Supply: 100-240Vac (4) Input: 4-20Ma Hart, 2X Pulse/Freq. (5) Housing: Remote, Alu, Coated ,Ip66 Nema 4X (6) Remote Version: 5M/15Ft Coil + Signal Cable (7)Electrical Connection: Thread Npt1/2 Joint Flange Asme B16.5 (8)Calibration Flow: 0.5% (9) Totalizer,8 Digit T/Hr. (10) Accuracy:+/- 0.35 % Of Measured Value, (11) Process Connection: Flange Connection Cl 150 Asme,316L/1.4404 Asme B16.5 Flange (12) Adjustment : Software Feature: Factoryset Up; Basicversion (13) Protection For Transmitter : Ip-67, (14) Zero Flow Detection(15) Reverse Flow Detectionnote:- Reducer/Expander Not Acceptable , Work Part , Instalation & Commissioning Of Above Flow Meters Alongwith All Required Material, Hardware, Accessories, Consumables Etc