Tender For Maintenance Of Electrical Installations, Fans, Street Light/ Compound Light/ Security Light, Air-Conditioning, Pump Set, Dg Set At Fire Station Connaught Place, Fire Station Rakaab Ganj ,Chanakya Puri, New Delhi, delhi-Delhi

Public Works Department-PWD has published Tender For Maintenance Of Electrical Installations, Fans, Street Light/ Compound Light/ Security Light, Air-Conditioning, Pump Set, Dg Set At Fire Station Connaught Place, Fire Station Rakaab Ganj ,Chanakya Puri, New Delhi. Submission Date for this Tender is 01-07-2023. Electrical Maintenance Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

38362065
Tender For Maintenance Of Electrical Installations, Fans, Street Light/ Compound Light/ Security Light, Air-Conditioning, Pump Set, Dg Set At Fire Station Connaught Place, Fire Station Rakaab Ganj ,Chanakya Puri, New Delhi
Open Tender
Indian
Delhi
delhi
01-07-2023

Tender Details

Tender For Maintenance Of Electrical Installations, Fans, Street Light / Compound Light / Security Light, Air-Conditioning, Pump Set, Dg Set At Fire Station Connaught Place, Fire Station Rakaab Ganj , Chanakya Puri, New Delhi

Key Value

Document Fees
Refer document
EMD
INR 68400.0 /-
Tender Value
INR 34.19 Lakhs /-

BOQ Items

Name of Work: MOEI & Fans, Street Light/ Compound Light/ Security Light, Air-Conditioning, Pump Set, DG Set at Fire Station Connaught Place, Fire Station Rakaab Ganj & Chanakya Puri, New Delhi (SH:- Routine Maintenance & Operation of various Electrical & Mechanical Services & Miscellaneous Electrical Works).
Sl. No. Item Description
1SH-I (RMO Work) Routine maintenance and attending day to day complaints of electrical installations and compound/security lights along with allied fixtures & feeder pillars etc. including repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc. and providing assistance to the Engineer-in-charge during breakdown maintenance complete with replacement of worn-out parts issued by the department to the contractor & keeping the entire installation on functional mode including operation & maintenance of various capacity drinking water supply pump sets, DG set comprising of AMF panel & allied accessories and carrying out the daily drill comprising of cleaning of pump house and maintaining log book for above installation by deploying staffs as per details of staff, terms & conditions and Inventory attached etc. as required.
2SH-II (Miscellaneous Electrical Works) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group B
3(b) Group C
4Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit including dismantling as required. (a) Group B
5(b) Group C
6Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
7(b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
8(c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
9Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. Mm
10(b) 3 x 4 sq. Mm
11(c) 3 x 6 sq. Mm
12Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm
13Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm
14Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
15Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
16Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (a) 12 Module (200 mmX150 mm)
17(b) 8 Module (125 mmX125 mm)
18(c) 6 Module (200 mmX75 mm)
19Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (a) 1 or 2 Module
20(b) 3 Module
21(c) 6 Module
22(d) 8 Module
23(e) 12 Module
24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 A switch
25(b) 3 pin 5/6 A socket outlet
26(c) 15/16 A switch
27(d) 6 pin 15/16 A socket outlet
28Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
29Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 12 way, Double door
30Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole
31(b) Single pole and neutral
32Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 36W full window glare free opal diffuser LED panel luminaries of size 2 x 2 feet (nominal size) including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The total system wattage not more than of 36W, LED lumen should be = 3960 system efficacy of = 110 lumen /watt colour temperature 4000K to 5700K, power factor>0.95, CRI (Ra)>80, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
33Supplying, laying and fixing of following PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade etc as reqd. in the following manner: (a) 3 x 10 sq.mm on wall surface
34(b) 4 x 16 sq.mm on wall surface
35Supplying of following material etc. complete as required. 1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable a)1.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
36b)4.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
37c)6.0 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable
38d)25 mm dia. ISI marked, steel conduit
39e)25 mm dia. ISI marked, PVC conduit
40f)Modular GI box for 3 module
41g)Modular GI box for 6 module
42h)Modular GI box for 12 module
43i)3 pin 5/6 A modular socket outlet, ISI marked
44j)6 pin 15/16 A modular socket outlet, ISI marked
45k)S.P. 5/6 A, one way modular switch, ISI marked
46l)S.P. 15/16 A, one way modular switch, ISI marked
47m)Modular base & cover plate for 3 module
48n)Modular base & cover plate for 6 module
49o)Modular base & cover plate for 12 module
50p)6 A to 32 A ratings, SP MCB, “C” curve, 10 kA breaking capacity
51q)6 A to 32 A ratings, SPN MCB, “C” curve, 10 kA breaking capacity
52Credit of assorted electrical material such as copper wire/cable, steel/pvc conduit, switch-socket, GI Box, DB, MCB, MCCB, aluminium cables etc.
53Add @31.27% on DSR-2016 (E) Items (i.e. on Rs. 633251/-)
54Less @ 9.50% on DSR-2016 (E) Items (i.e. on Rs. 633251/-)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail