Heavey Water Board-HWB has published Tender For Electrical Amc For Plant And Colony At Hwbf Vadodara. Submission Date for this Tender is 13-07-2023. Electrical Maintenance Tenders in vadodara Gujarat. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 07-Jul-2023 | Revised date of tender submission | Date | 13-07-2023 |
Sl. No. | Item Description |
1 | PartA Plant(S.No.1 to 75) Fabrication of support for light fitting/tray etc. |
2 | Supplying and drawing of 1*1.5 sq mm single core cable in the existing PVC conduit/casing capping. |
3 | Supplying and fixing of 19/20 mm...PVC conduit or 25/30 mm casing capping with clamps,...etc. |
4 | Supplying and drawing of 1*2.5 sq mm single core cable in the existing PVC conduit/casing capping. |
5 | Preparation of earth pit as per IS 3043 and connecting with existing earth pit grid. |
6 | Supply & installation of earthing pit frame...size (600 x 600)mm, including masonary…..labour. |
7 | Supply,Installation and connection.. of 8 SWG GI wire for carrying out earthing of LPBS, motors. |
8 | Supply , Installation and connection….of 12 SWG GI wire for carrying out earthing of LPBS, motors. |
9 | Supply and laying ...GI strip 25x3 mm size. |
10 | Supply and laying of ...GI strip 50 X 6mm size. |
11 | Preparation for Laying of cables Underground Road cutting and making good the same by usingPlain concerent cemen including supply of materials i.e. aggrregate, ..filling and labour required. |
12 | Excavation of earth for cable trenches/laying ofhume /PVC /G pipes for cable work, back filling......... finished ground level complete with labour and materials…secifications. |
13 | Supply of sand and bedding of the bottom of excavatedtrench with a 75mm thick layer of sand |
14 | Supply & installation of concrete / hume pipe of 150 mm NB & np3 class. |
15 | Supply & installation of concrete / hume pipe of250mm NB &np3 class. |
16 | Laying of 1.1KV grade, PVC-A-PVC, FRLS cables on Tray/Trench/ Structure Cables upto 25 mm OD |
17 | Cables of 26 mm to 40 mm OD |
18 | Cables of 41 mm to 55 mm OD |
19 | Cables of 56 mm to 75 mm OD |
20 | Removal of 1.1KV grade PVC/A-PVC/FRLS Cables from Tray/Trench/ Structure Cables upto 25 mm OD |
21 | Cables upto 26 mm to 40 mm OD |
22 | Cables upto 41 mm to 55 mm OD |
23 | Cables upto 56 mm to 75 mm OD |
24 | Glanding & termination (Flameproof) of 1.1KV PVC-A-PVC, FRLS Copper (Cu) Cables.(Supply of glands and lugs shall be in the scope of contractors.) Glanding & terminations of 3C/4C X 2.5 sq.mm |
25 | Glanding & terminations of 7C/12C X 2.5 sq.mm |
26 | Glanding & terminations of 3C/ 4CX 4.0 sq.mm |
27 | Glanding & terminations of 3C/ 4C X 6.0 sq.mm |
28 | Glanding & termination (Flameproof) of 1.1KV PVC-A-PVC, FRLS Aluminium (AL) Cables. (Supply of glands and lugs shall be in the scope of contractors.) Glanding & terminations of 3C/ 4C X 6.0 sq.mm |
29 | Glanding & terminations of 3C/ 4C X 10/16 sq.mm |
30 | Glanding & terminations of 3C/3.5C/ 4C X 25 /35 sq.mm |
31 | Glanding & terminations of 3C/3.5C X 50/70 sq.mm |
32 | Glanding & terminations of 3C/3.5C X 95/120 sq.mm |
33 | Glanding & terminations of 3C/3.5C X 150/185 sq.mm |
34 | Glanding & termination (Non-Flameproof) of 1.1KV PVC-A-PVC, FRLS Copper (Cu) Cables. (Supply of glands and lugs shall be in the scope of contractors.) Glanding & terminations of 3C/4C X 2.5 sq.mm |
35 | Glanding & terminations of 7C/12C X 2.5 sq.mm |
36 | Glanding & terminations of 3C/ 4CX 4.0 sq.mm |
37 | Glanding & terminations of 3C/ 4C X 6.0 sq.mm |
38 | Glanding & termination (Non-Flameproof) of 1.1KV PVC-A-PVC, FRLS Aluminium (AL) Cables. (Supply of glands and lugs shall be in the scope of contractors.) Glanding & terminations of 3C/ 4C X 6.0/10 sq.mm |
39 | Glanding & terminations of 3C/ 4C X 16 sq.mm |
40 | Glanding & terminations of 3C/ 4C X 25 sq.mm |
41 | Glanding & terminations of 3C/3.5C X 35 sq.mm |
42 | Glanding & terminations of 3C/3.5C X 50 sq.mm |
43 | Glanding & terminations of 3C/3.5C X 70 sq.mm |
44 | Glanding & terminations of 3C/3.5C X 95 sq.mm |
45 | Glanding & terminations of 3C/3.5C X 120 sq.mm |
46 | Glanding & terminations of 3C/3.5C X 150 sq.mm |
47 | Glanding & terminations of 3C/3.5C X 185/245 sq.mm |
48 | Single core (Un-Armoured) Copper (Cu) 1.1KV PVC-A-PVC, FRLS Cables. (Supply of lugs shall be in the scope of contractors.) Lugging & terminations of 4.0/6.0 sq.mm |
49 | Lugging & terminations of 50/70/95sq.mm |
50 | Lugging & terminations of 120/150 sq.mm |
51 | Lugging & terminations of 300/400 sq.mm |
52 | Supply of3M/M-seal make cable jointing kit and carry outjointing of1.1KV PVC-A-PVC, FRLS Cables copper (Cu) of size 3C/4C/7C X 2.5 sq.mm . |
53 | 12C/16C X 2.5 sq.mm |
54 | 3C/4C X 4.0sq.mm |
55 | 3C/4C X 6.0sq.mm |
56 | Supply & installation of3M/M-seal make cable jointing kit and carry outjointing of1.1KV PVC-A-PVC, FRLS Cables Aluminium (Al) of size: 3C/4C X 6.0/10.0 sq.mm |
57 | 3C/4C X 16/25 sq.mm |
58 | 3C/ 3.5C X 35/50sq.mm |
59 | 3C/3.5C X 70 / 3CX95 sq.mm |
60 | 3.5C X 95 / 3C X120 sq.mm. |
61 | 3.5C X 120 / 3C X 150 sq.mm |
62 | 3.5C X 150 / 3C X 185 sq.mm |
63 | Installation of cable trays of size 500mm wide on supports. |
64 | Installation of cable trays of size 250/150 mm wide on supports / structures. |
65 | Supply, installation and testing of Vertical Air terminations for lightning protection as IS-2309. |
66 | Repairing, rewinding of ceiling fan motor includes bearings & capacitor 45-60 watt |
67 | Repairing, rewinding of exhaust fan ( 300 mm) motor includes bearings & capacitor 50-60 watt |
68 | Repairing, rewinding of exhaust fan/pedestal fan/air cooler (400/500 mm sweep) motor includes bearings & capacitor (60-80) watt |
69 | Making arrangement for attending trouble shooting of elect. system like repairing of light fitting, board / fans / tube lights…etc. beyond 8hrs (single visit of 2 hrs) |
70 | Making arrangement for assisting and cleanining & trouble shooting of elect. system like panels, motors, light fitting... etc.beyond 8hrs ( single visit of 2 hrs). |
71 | Earth reisistance measur. and maintenance of Earthing Pit. |
72 | Making arrangement for supervision of job ….maintenance of electrical system………. during General shift / Round the clock shift duty for 8hrs. |
73 | Making arrangement for attending trouble shooting of electrical system……..General shift / Round the clock shift duty for 8hrs. |
74 | Making arrangement for assisting and logging the data….f electrical system like …..general shift / Round the clock shift duty for 8hrs. |
75 | Making arrangement for assisting and cleanining of electrical system……... during General shift / Round the clock shift duty for 8hrs. |
76 | Making arrangement for attending trouble shooting of electrical system…….General shift / Round the clock shift duty for 8hrs in colonies |
77 | Making arrangement for assisting and cleanining of light fitting….etc. for 8 hrs in Nizmpura& Danteshwar olonies. |
78 | Making arrangement for attending trouble shooting of elect. system …..fans / tube lights…etc. beyond 8hrs (single visit of 2 hrs) at colonies. |
79 | Making arrangement for assisting and cleanining & trouble shooting of elect. System... light fitting... etc.beyond 8hrs ( single visit of 2 hrs) at colonies. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy