Military Engineer Services-MES has published Tender For Repair /Maintenance Of Summer / Winter Appliances And Ceiling Fans And Petty Repairs Of Em Nature Including Internal Electrification At Cod Chheoki. Submission Date for this Tender is 19-07-2023. Electrification Work Tenders in prayagraj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

38324541
Corrigendum : Tender For Repair /Maintenance Of Summer / Winter Appliances And Ceiling Fans And Petty Repairs Of Em Nature Including Internal Electrification At Cod Chheoki
Open Tender
Indian
Uttar Pradesh
prayagraj
19-07-2023

Tender Details

Repair /Maintenance Of Summer / Winter Appliances And Ceiling Fans And Petty Repairs Of Em Nature Including Internal Electrification At Cod Chheoki

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Jul-2023 revised BOQ BOQ 12-07-2023
2 12-Jul-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-07-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work: REPAIR /MAINTENANCE OF SUMMER / WINTER APPLIANCES AND CEILING FANS AND PETTY REPAIRS OF EM NATURE INCLUDING INTERNAL ELECTRIFICATION AT COD CHHEOKI.
Sl. No. Item Description
1Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existingcompleteall as specified & directed.
2M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) along with same size and type of wire as continuous earth wire connected to common earth dolly drawn in and includingnon metallicPVC casing and capingnot less than 20mm widemed grade ISI marked complete with all fixing accessories including factory madepressed steel concealed terminal boxof required size of 1.2mm thickduly painted with 3mm thick plasticlaminated sheet top cover with brass screw and cup washerscomplete all as specified and directedfor the following :- . Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface.
3One light/fan/bell point controlled by one switch
4One point for socket outlet 5 amps on independent board
5One point for socket outlet 5 amp same board
6One 3 pin socket outlet 15 amps, independent, with cables 2.5 sq. mm size on independent board.
7M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade surface conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surfaces complete all as specified and directed for the following :-Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface.
8One light/fan/bell point controlled by one switch
9One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane.
10One point for socket outlet 5 amp same board
11One 3 pin socket outlet 15 amps, independent, with cables 2.5 sq. mm size on independent board.
12M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 Sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade concealed conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :- Note:(a) Colour code of wire shall be strictly followed , Red for Phase , Black for neutral and green for earth wire (b) The unit rate quoted is deemed to be inclusive of cost of cutting chases in wall for providing concealed conduit and making good to match with existing finish/surface.
13One light/fan/bell point controlled by one switch
14One point for socket outlet 5 amps on independent board
15One point for socket outlet 5 amp same board
16One 3 pin socket outlet 15 amps, independent, with cables 2.5 sq. mm size on independent board.
17S&F ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
18S&F angle/batten type holder insulated body with back plate suitable for light point complete all as specified and directed.
19S&F switch piano flush type, 5 amps, 230V AC,single pole, one waycompleteall as specified & directed.
20S&F socket out let 2-in-1, 3 pin, 5 amp flush type completeall as specified & directed.
21S&F switch piano flush type 16 amps, 230V AC single pole one waycompleteall as specified & directed.
22S&F socket out let 2-in-1, 3 pin, 5 & 15 amp flush type completeall as specified & directed.
23S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection complete all as specified & directed.
24S&F bell push piano flush type 5 amp, SP , 230V ACcompleteall as specified & directed.
25S & F lamp holder adopter, two pin, insulated bakelite body for proper connection to light fitting/fixture from light point completeall as specified & directed.
26S&F call bell, ding dong type, AC, 230 V, single polecompleteall as specified & directed.
27S&F switch modular flush type 6 amps, single pole, one way 230 voltcompleteall as specified & directed.
28S&F socket modular flush type suitable for 6 amp, 5 pin ,230 voltcompleteall as specified & directed.
29S&F switch modular flush type 16 amps, single pole, one way ,230 voltcompleteall as specified & directed.
30S&F socket modular flush type suitable for 16 amp, 6 pin ,230 voltcompleteall as specified & directed.
31S&F fan regulator, 2 module type, 5 stepped, electronic type, single phase 230 volt includingconnection complete all as specified & directed.
32S&F bell push modular flush type 6 amp 230 voltcompleteall as specified & directed.
33S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, C series 240 volts AC completeall as specified & directed.
34Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfacescompleteall as specified & directed.
35S&F sheet metal enclosure for MCB"s 240 volt 12 way triple pole and neutral with 200 amps rated busbardouble door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wallcomplete all as specified and directed.
36S&F sheet metal enclosure for MCB"s 240 volt 4 way single pole and neutral with 200 amps rated busbardouble door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wallcomplete all as specified and directed.
37S&F sheet metal enclosure for MCB"s 240 volt 8 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
38S&F MCB single pole, 6 to 32 amps rating, 240 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
39S&F MCB single pole & Neutral, 32 amps rating, 240 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
40S&FMCB single pole & neutral 40 to 63 amp, 240 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
41S&F in repair MCB triple pole & neutral 100 amp, 415 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
42Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories completeall as specified & directed.
43M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 10 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 10 Sqmm as earth continuity conductor making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
44M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 6.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm as earth continuity conductor making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
45M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 4.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 2.5 Sqmm as earth continuity conductor & making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
46M&L for concealed submain wiring using FRLS PVC insulated, unsheathed stranded copper conductor cable two single core of size 4.0 Sqmm of voltage rating upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 20 mm dia with all fittings and accessories alongwith one run of PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm as earth continuity conductor & making good to disturbed surface with CM 1:4 and colour wash complete all as specified & directed. Note:- (i) Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one length. (ii) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.
47Supply & fixing in replacement of worn out/rustedsunken box of size 100 mm X 100 mm with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mmof following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
48Supply & fixing in replacement of worn out/rustedsunken box of size 200 mm X 150 mm with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mmof following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
49Supply & fixing in replacement of worn out/rustedsunken box of size 250 mm X 200 mm with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mmof following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
50Taking down existing old /worn out tube/CFL/bulk head/sketch light fittings of indoor type fixed on wall of any type/size with its all accessories including lamp complete all as specified & directed
51Supply & fixing surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen output - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed.
52Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, Surge protection 3KV, CRI>80 life 40000 hrs sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat part No: -LUMILINEPLUSSBS10WLED865SPCSS of make Havells "or" BN 021 LED10S- 6500 PSU GR S1 of make Philips "or" LDL-10-WW of make Crompton or its equivalent as approved
53S&F energy efficient LED Bulkhead in high pressure die cast aluminium housing of system wattage - 9/10 Watt, lumen out put - 700 Lm, colour Temp - 6500 K having Ingress protection - IP 65 fpr dust, water & IK 08 for external impact complete all as specified and directed.
54S&F in replacement of worn out/old linear fluorescent tube of 36 watt with energy efficient/saving retrofitLED tube in polycarbonate housing of nominal wattage - 18/20 Watt, Lumen output - 2100 Lm or above, Colour Temp - 6500 Kelvin, Size & Length - G13/T8/4 Feet, Operating Voltage - 230 Volt AC, THD = 20 % with integral/in built driver, having short circuit and surge protection upto 4 KV and other safety test as per IS 15885 Part 2/Sec 13 including making minor addition/alteration in existing circuit as required complete all as specified and directed.
55Supply & fixing in replacement of worn out 36 watt FPL with retro fit linear LED PLL lamp with extruded plastic body and PC diffuser complete with inbuilt electronic driver of high efficacy of system wattage 18 Watt, Length - 419 mm, Lumen output - 1800 Lm or above, Colour Temp - 6500 K suitable for installation in existing 2G11 lamp holders including minor alteration in existing circuit as required complete all as specified and directed.
56S&F in replacement of existing worn out ceiling light with environmental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36/40/42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed.
57S&F in replacement round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers , holders, LED lamp suitable for proof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
58S&F in replacement round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers , holders, LED lamp suitable for proof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
59S&F in replacement round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers , holders, LED lamp suitable for proof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
60M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washersincluding necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and saltPCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover reinforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
61CEILING FAN, EXHAUST FAN
62M&L for rewinding of stator complete with super enameled copper winding wire of existing gauge/ weight of copper coil, quick varnishing, oiling, greasinginsulating materials including replacement of worn out parts like u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, and testingof the following size of fans of any make complete all as specified and directed. Note - (i) Fans to be collected by the contractor at their own arrangement from AGE E/M store forrepair/rewinding and to be deposited at same place after making serviceable duly tested. (ii) Additional spare parts as required to make the serviceable of same will be measured and paid separately as supply only under srl item No. 3 of schedule here in below:-
63Ceiling fan of 1200 mm sweep
64Ceiling fan of 1400 mm sweep
65Exhaust fan of 230 mm sweep
66Exhaust fan of 300 mm sweep
67Exhaust fan of 380 mm sweep
68Exhaust fan of 450 mm sweep
69Wall fan/cabin/Pedestal of 400 mm sweep
70Industrial wall fan of 480/ 600 mm sweep
71Supply only following spare parts for Ceiling / Exhaust fan : -
72Ball bearing of ceiling/exhaust fan of any size of exactly similar as existing in fan complete all as specified and directed. (Make-NBC/SKF)
73U" shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel etc. suitable to the down rod pipe and connecting complete all as specified and directed.
74Capacitor 2.5 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
75Capacitor 3.15 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
76PVC insulated, sheathed flexible copper conductor cable in three core of size 23/0.0076 from connector to the ceiling rose complete all as specified and directed.
77Capacitor clip as per existing complete all as specified and directed.
78Canopy for ceiling fan suitable for any sweep/make as required incl. screw complete all as specified and directed.
79M&Lfor Spray painting of stained/rusted/corroded Ceiling fan/Exhaust fan complete body with one coats of synthetic enamel white/smoke gray paint incl writing of MES No over one coat of primer all as specified and directed.
80S&F in replacement of MS louvers shutters on wall suitable for 300 mm sweep exhaust fan including suitable size of nut, bolts & washercomplete all as specified and directed.
81S&F in replacement of MS louvers shutters on wall suitable for 450 mm sweep exhaust fan including suitable size of nut, bolts & washercomplete all as specified and directed.
82M & L for servicing of ceiling fans at site, oiling, greasing and checking of fan hook for damage spilt pin, nut bolt, rubber reels and down rod including proving new split pin and replacement of damage nut bolt and down rod complete all as specified and directed. Note: (i)Down rod measured and paid separately under relevant items
83S&F in replacement Mild steel"Medium grade" 15mm dia pipe down rod of required length with makingsplit, holes, cut etc at both end of pipe as required for hanging ofceiling fan including painting of rod with two coats of synthetic enamel white paint over one coat of primer along with U" shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel complete all as specified and directed.
84S&F in repair fan hook suitable for 40 mm dia pipe, made out of MS flat iron size 50x6 mm including suitable size of nut, bolt & washer complete all as specified and directed.
85AC WINDOW/SPLIT TYPE
86Repair/maint of window type AC/split AC any capacity of any make by cleaning and servicing of serviceable parts replacement of wiring kit, knobs & unserviceable parts replacement of air filter made of jute and reassembling the serviceable spare parts etc and testing for smooth functioning and re installation at site or deposit in MES store yard after repair. [Notes : (a) Spare parts shall be measured and paid separately as supply only under respective items. (b) Replacement of nuts, bolts and washers deemed to be included in unit rate. (c) Minor repair of chesis by brazing/welding work deemed to be included in unit rate.]
87Removing burnt/defective sealed compressor unit of any make from any type of air conditioner window type 1.5 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc all as directed. Make:Emerssion/ LG/ Haier
88All as per item No. 60 above but for 1.5 ton Split type Air conditioner [Notes : (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only. (c) Unserviceable compressor either cut open or sealed unit have to be replaced by new one
89All as per item No. 60 above but for air conditioner window / split type 2 ton capacity
90Repair to Air conditioner window type/Split type 1/1.5/2 ton capacity by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system and charging of gas as existing andtesting etc complete all as specified & directed (Note : Drier capillary and copper tubing are inclusive in unit rate)
91S&F in replacement of blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type 1.5 ton capacity blower motor complete all as directed and specified
92S&F in replacement of blower Motor 0.2/0.25 HP for Air conditioner split type 1.5 ton/2 ton complete and as directed and specified (Make - GE/Crompton/Polar)
93M & L for repair to blower Motor1/6 HP to 0.25 HPwith super enamelled copper wire of existing size suitable for Air conditioner window type / split type complete all asspecifiedand directed
94M& L for repair to PCB circuit in air conditioner split type all as specified & directed.
95S&F in replacement ofpower contactor 240V AC, 50 Hz 16 - 25 Amps range (ISI marked) as approved complete all asspecifiedand directed.
96Supply and fixed in replacement of power contactor 415V AC, 50 Hz 15 Amps (Make - L&T Type MK-I/BCH or as approved)
97M&L for painting of chassis/body of AC with one coat of synthetic enamel paint by spray painting of approved make including preparation of surface and one coat of aluminium paint to outer cover.
98Supply only following spare parts for window type AC capacity 1.5/2 ton : -
99Capacitor 4 mfd
100Running capacitor 36 mfd AC
101Starter capacitor 80/100 mfd
102Relay any make and type as approved
103Over load protector
104Thermostat
105Cooling coil
106Filter pad made of Jute
107Condensers coil
108Selector switch
109Wiring kit
110Front Panel of window AC any make of 1.5/2TR
111Blower
112M&L for Stands for Discharge unit of Split type AC/ Desert coolerstand etc. as per requirement and directed by Engr -in-charge
113S&F in replacement indoor unit of AC 1.5 ton capacity split type of approved make as directed (Note-Old unit to be deposited in MES store yard)
114DESERT COOLER
115Opening of the Desert Cooler of any capacity and make, dismantling of complete items and its repair cleaning of serviceable parts, replacement of unserviceable or worn out parts, opening of Fan motorfrom their brackets, scraping out of old paint of complete body (internally & externally) of Desert Coolers making good, smooth surface andapplying spray painting with one coat of synthetic enamel paintforexternal surfaces/ internal surface replacement of wooden wool pad - 3 Nos and fixing of Fan Motor and Pump, replacement of internal wiring and rotary switch with pump and Fan motor connection and testing after repair complete. Note: (i) Overhauling/Oiling of fan motor, Vertical pump replacement of Nuts, bolts washers/elbow, if required shall be deemed to be included in unit quoted rate. (ii) Cost of replacement of grass pad deemed to be included in quoted rate.(iii) Capacity of desert Cooler upto 2500 to 6000 cum/hrs.(i) Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item.(ii) Replacement ofwool pad- 3 Nos. deemed to be included in quoted rate.(iii) Minor repair of chassis of brazing/welding work deemed to be included in unit rate.(iv) Provide PVC Sheathedcable of 23/.0076 up to 1.5 meter in replacement if required will be deemed included in the unit rate.
116Supply only fan motor of 1/6 HP to 1/10 HP230V AC electric of same capacity and same
117Supply only Blade for kit Fan.
118Supply onlyMS Bracket for kit Fan Motor
119Supply only Submersible Pump set suitable for desert coolers of fractional H.P. Make : CG/Bajaj/Havells/Vansal or Summar cool/ Zolta (Khaitan).
120Supply only Rotory Switch
121Supply only Front Directional Grill
122Supply only PVC pipe 10 mm dia flexible
123Supply only Side panel made out of PGI Sheet 1 mm thick of size not less than 0.5 m width and 0.7m height complete.
124Supply only Storage tank made out of PGI Sheet 1 mm thick of size not less than 0.7 m X 0.7M and height 0.2m complete.
125S&F Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V,50 Hz RPM 1200, Copper winding of sweep 300 mm
126WATER COOLER
127Dismantling of electric connection and water connection of water cooler & opening the condenser fan motor blade, electrical accessories and spare parts of system carefully servicing of serviceable parts, replacement of U/S parts, oiling of fan motor etc reassembling all spare parts incl rewiring of internal connection of water cooler, testing and commissioning complete all as specified. (Note: Worn out or unserviceable spare parts to be replaced & shall be measured and paid separately as supply only under respective item.)
128Removing burnt/defective sealed compressor unit of any make from water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit Make as existing or equivalent in kirloskar or tecumsehby tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work etc complete. [Note:- (i) Cost of transportation shall be deemed to be included in the quoted rates. GI fitting damaged while taking out/fixing back water coolers shall be replaced by the contractor at his own cost. (ii) New compressor shall be purchased from authorised dealer only. (iii) Capillary, drier, filter strainer are inclusive in unit rate. (iv) Old compressor either cut open or sealed have to replaced with new one.]
129All as per item No 101 above but water cooler Cap 60 Ltrs/hr
130All as per item No 101 above but water cooler cap 150 Ltrs/hr.
131M&L for replacement of Rubber hose pipe of 20mm bore with clips for outlet tray of water cooler of length 1.5 Mtr long approx. complete all as specified & directed
132M&L for replacement of PVC sheet rubber bedding and lock of top cover of water cooler by screwing/welding MS sheet of top cover complete all as specified & directed
133M&L for replacement of PVC connection rigid type 18” long 15mm bore, with adopter at both ends complete all as specified & directed.
134M&L for making the system leak proof and charging of gas Freon 12/22 as required in water cooler of capacity 40/60 Ltr including replacement of drier and capacity tube and testing on load complete all as specified & directed.
135All as per item No. 107 above but of capacity 120/150 ltrs.
136M&L for scraping old painted surface of water cooler any capacity and painting with two coats of synthetic enameled paint including writing SM/MES No with black paint with minimum 25 mm size of letters complete all as specified & directed.
137M&L for replacement of old condenser fins with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete all as specified & directed.
138S&F in replacement of condenser fan motor of cap 1/35 HP with fan blade complete all as specified & directed.
139M & L for winding of condenser fan motor of cap upto 1/8 HP with super enamelled copper wire of existing size including replacement of bush and fan blade incl painting complete all as specified & directed.
140S&F in replacement of push cock/lift cock brass chromium plated 15 mm bore complete all as specified & directed..
141M&L for replacement of 40 mm dia flexible PVC pipe for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions complete all as specified & directed.
142M&L for replacement of 50 mm dia flexible PVC pipe for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions complete all as specified & directed.
143M&L for replacement of 60 mm dia flexible PVC pipe for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions complete all as specified & directed.
144Detection and rectification of leakage of storage tank of water cooler by brazing soldering/welding as required at site or work shop testing for leak proof complete all as specified & directed. [Note : (a) Nipple adoptor if required deemed to be included in unit rate. (b) Push cock, float valve etc if required will be measured and paid separately. (c) Changing of rubber/plastic packing is incl in unit rate]
145Taking out the drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting/painting and including replacement of new PVC pipe of suitable size and length and refixing back all as directed.
146Supply only following spare parts for water cooler : -
147Starting capacitor 60/80 mfd
148Running capacitor 10 mfd
149Thermostat
150Relay over load kit
151Relay
152Over load protector 1022
153Wiring kit
154Strainer/filter drum type/pen type
155Door gasket
156Float valve 1/2" including assembly brass made.
157VOLTAGE STABILIZER
158M&L for opening unserviceable automatic voltage stabilizer capacity 5 KVA / 4 KVA for repair,detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M New Cantt" all as directed any make:-[Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately as supply only under respective item.(b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.]
159M&L for opening unserviceable automatic voltage stabilizer capacity 3 KVA for repair,detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M New Cantt" all as directed any make:-[Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately as supply only under respective item. (b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.]
160Supply only the following spare parts suitable for automatic voltage stabilizer of any make and capacity :-
161Volt meter (0-300 volts)
162Control relay
163IC controlled circuit for 5KVA/4 KVA
164IC controlled circuit for 3 KVA
165Control transformer
166Low/high voltage cut off and TDR system
167Main transformer for 5 KVA/4 KVA
168Main transformer 3 KVA
1693 pin plug top 16 amp make Anchor
170M&L for rewinding of boost/buck transformer of5 KVA/4 KVA capacity stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically complete all as specified & directed.
171M&L for rewinding of boost/buck transformer of3 KVA capacity stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically complete all as specified & directed.
172S&F in replacementof 5 KVA stabilizer 230 volts Single phase (Note-Old to be deposited in MES store yard). (Make : Blue star/Vinitec/Brentford/Automatic Electric)
173WINETR APPLIANCES
174Taking down existing geyser any capacity/ type after suitable disconnecting all electrical and water supply connection, removing geyser to E/M store, opening and dismantling the complete geyser, cleaning all serviceable parts completely including descaling the geyser, for replacing the defective/wornout parts, reassembling the geyser, testing for proper functioning, transporting to& refixing in original location i.e. in the same in position, reconnecting the geyser with electric supply and water supply line and testing complete all as specified and directed. Note :-(i) Parts/sparesrequired for replacement shall be measured and paid separately as supply only under respective item. (ii) Unit rate quoted shall be deemed to include minor items i.e. nut bolts, screws, lugs etc .
175S&F in repair Heating element Square, threaded/ screwed type 1500 watt ISI markedcomplete all as specified and directed. Make Theeta/ Bajaj/ Hot top/Daspass or equivalent as approved.
176S&F in repair Heating element cup type 1500 watt (ISI marked) complete all as specified and directed.Make - Bajaj/ Dass Pass/ Threeta or equivalent approved.
177S&F in repair Heating element threaded/screwed type 2000 watt (ISI marked) suitable markedcomplete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
178S&F in repair Heating elementcup type 3000 watt (ISI marked) complete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
179S&F in repair Thermostat suitable for geyser range 20 degree to 80 degree (ISI marked) complete all as specified and directed.Make-Thermoking/TTE,Elcon/ Expo/ Antriksh or equivalent approved.
180S&F in repair PVC connection cotton braided heavy duty with brass union/coupling of length 450 mm with rubber washer suitable for 15 mm pipe complete all as specified and directed..
181S&F in repair Hot water outlet connection made of chromium plated flexible tubing for 15 mm bore pipe complete all as specified and directed.
182S&F in repair Indicator lamp assembly with bulb with long lead suitable for geysers round or square type as sample kept in GE’s office complete all as specified and directed..
183S&F in repair PVC insulated flexible wire three core 2.5 sqmm copper conductor heavy duty complete all as specified and directed..
184S&F in repair Aperture plate assembly suitable for25 ltrs geysers complete all as specified and directed.
185S&F in repair Aperture plate assembly suitablefor 50 ltrs geysers complete all as specified and directed.
186S&F in repair Inner copper tank made out of 0.8mm(min.)for 25 ltrs geyser complete all as specified and directed.
187S&F in repair Outer body with red, green indicator and bottom cover as per existing size & shape of capacity 25 ltrs geyser complete all as specified and directed.
188S&F in repair 3 pin 15 amp plug top complete all as specified and directed. Make Anchor or equivalent as approved
189M&L for painting of geysers after scraping, cleaning and preparing surface for painting and painting with two coats of white enameled paint of approved make and sign writing MES No etc of 25 ltr capacity geyser complete all as specified and directed
190M&L for painting of geysers after scraping, cleaning and preparing surface for painting and painting with two coats of white enameled paint of approved make and sign writing MES No etc of 50 ltr capacity geyser complete all as specified and directed
191Repair of leakage of inner tank 25/50 ltr capacity geyser by brazing/soldering, testing including cutting of nut, bolt as required with gas welding cutter and providing new nut, bolts, washers etc complete all as specified and directed.
192S&F in repairs Chromium plated brass stop cock 15 mm bore, screwed down, high pressure with crutch or butterfly handle complete all as specified and directed.
193S&F in repairs MCB DP 32 amp, 230 volt, AC , 10 KAwith indication & enclosure complete all as specified and directed.
194S&F in repairs mild steelfoundation nuts, bolts & washers heavy duty for fixing of geyser including grouting in wall complete all as specified and directed. .
195S&Ftwo pin and earth plug and socket sheet metal enclosurewith one single pole MCB 20 amp rating, 240 volt,C" series,10 KA breaking capacity complete all as specified and directed.
196M&L for Non return valve verticletype screwed for both ends with 15mm bore GI pipe. Complete all as specified and as directed.
197S&F in repair fusible plug steel nut complete all as specified and directed.
198S&F in repair Timer suitable for Hevalls geyser (ISI marked) complete all as specified and directed.
199PETTY REPAIRS
200S&F in repair pendant type lamp holder, PVC/Polycarbonate type with cord grip cap complete all as specified and directed.
201S&F in repair lamp holder of base Cap G - 13suitable for 20/36 Watt FTL complete all as specified and directed.
202S&F in repair lamp holder of base cap 2 G-11 suitable for non retrofit 36 CFL complete all as specified and directed.
203S&F in repair socket out let 6 pin, 16 Amps flush type complete all as specified and directed.
204S&F in repair switch, single pole, one way, 16 Amps complete all as specified and directed.
205S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 0.75 Sqmm or 24/0.20, 1100 Volt grade, ISI marked complete all as specified and directed.
206S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 1.5 Sqmm or 22/0.30 or 48/0.20 or 30/0.25, 1100 Volt grade, ISI marked complete all as specified and directed.
207S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size2.5 Sqmm or 36/0.30 or 80/0.20 or 50/0.25 , 1100 Volt grade, ISI marked complete all as specified and directed.
208S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 4.0 Sqmm or 56/0.30 or 128/0.20, 1100 Volt grade, ISI marked complete all as specified and directed.
209S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 6.0 Sqmm or 84/0.30, 1100 Volt grade, ISI marked complete all as specified and directed.
210S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 10.0 Sqmm or 140/0.30, 1100 Volt grade, ISI marked complete all as specified and directed.
211S&F in repair PVC insulated, unsheathed flexible twin twisted copper conductor wire ofnominal size 23/0.0076 complete all as specified and directed.
212S&F in repair PVC insulated, unsheathed flexible twin twisted copper conductor wire ofnominal size 40/0.0076 complete all as specified and directed.
213S&F PVC insulation tape of width - 18 mm, thickness - 0.125 mm in length of 25 mtr, ISI markedfor proper insulation of joints in wire where as required or directed
214S&F in replacement of worn out/old linear fluorescent tube of 28 watt with energy efficient/saving retrofit LED tube in transparent glass housing to provide glare free light distributionof nominal system wattage - 16 Watt, Lumen out put - 1800 Lm or above, Colour Temp - 6500 Kelvin, Size & Length - G5/T5/4 Feet, Operating Voltage range - 140 to 270 Volt AC, THD = 15 % with integral/in built electronic driver (SMPS based constant current supply) having short circuit and surge protection upto 2.5 KV and other safety test as per IS 15885 Part 2/Sec 13 including making minor addition/alteration in existing circuit as required complete all as specified and directed.
215Supply and fixing in replacement of worn out wooden batten/PVC Conduit with Non Metallic Rigid PVC conduit of 20 mm nominal dia, ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
216Supply and fixing in replacement of worn out wooden batten/PVC Conduit with Non Metallic Rigid PVC conduit of 25 mm nominal dia, ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.