New Delhi Municipal Council-NDMC has published Tender For Renovation Of Room No. 2001A (2Nd Floor) And 1110 (11Th Floor) At Palika Kendra Building (Electrical Works). Submission Date for this Tender is 03-07-2023. Electrical Maintenance Tenders in New Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group – C |
2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
3 | Wiring for circuit/ sub-main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
4 | 2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required |
6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
7 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
8 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
9 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps |
10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
11 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
12 | Installation, testing and commissioning of pre-wired, LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
13 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 4 Pair |
14 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
15 | Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
16 | Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface / recessed steel / PVC conduit as required. 2 run of cable. |
17 | Supplying and fixing following size / modulus, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module (100mmx75mm) |
18 | Supplying and fixing of following modular base & cover plate on existing modular metal boxes etc. as required. 3 modules |
19 | Supplying and fixing call bell / buzzer suitable for single phase, 230 Volt, complete as required. |
20 | Supply of recess mounted LED fitting with higher efficiency, full diffuser providing uniform light suitable for indoor spaces having following specification: Wattage: 24 watt Size: 1’X1’ THD=10 Operating Voltage: 110-280 Volt CCT (K): 5700±5% Make: Wipro / Philips / Syska |
21 | Supply of recess mounted LED fitting with higher efficiency, full diffuser providing uniform light suitable for indoor spaces having following specification: Wattage: 36 watt Size: 2’X2’ THD=10 Operating Voltage: 110-280 Volt CCT (K): 4000±5% Make: Wipro / Philips / Syska |
22 | Supply of wall fan 16” size complete as required Make: Crompton / Havells / Usha |
23 | Supply of ceiling fan 56” size, 3 blade, high speed (minimum speed 280 rpm) air delivery 250m³ per minute, copper winding, white colour. Make: Crompton /Usha / Orient |
24 | Supply of 2 TR split AC type air-conditioners with remote control rating operation on 220-240 Volt, 50 Hz, single phase supply having EER as 3.5 and above having copper condenser coil. Make: Daikin / Hitachi / Carrier |
25 | Fixing of 1.5 / 2 TR capacity Split type AC Indoor on its base plate & Outdoor units in proper condition with suitable size of nut-bolts & washers, PVC gitti, steel screws of suitable size and miscellaneous items required at site. |
26 | Providing & fixing of iron stand (Vertical / Horizontal) for 1.5 / 2 TR capacity split type AC units complete with suitable size of fastener, nut-bolt & washer etc.as required at site. |
27 | Providing & fixing of suction & discharge copper pipe for 1.5 TR / 2 / 2.5 TR capacities for split type AC including 3 cores PVC insulated wire of suitable size and PVC pipe for drainage with foam insulation in surface / recess in wall complete as reqd at site. |
28 | Credit for retaining the old switch, socket and iron scrap etc. |