Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-07-2023 | Earnest Money | Technical Bid | 14-07-2023 |
| Sl. No. | Item Description |
| 1 | Earthworkinexcavationbymechanicalmeans(Hydraulicexcavator)/manual meansinfoundationtrenchesordrains(notexceeding1.5minwidthor10sqmon plan),includingdressingofsidesandrammingofbottoms,liftupto1.5m,including getting outthe excavated soil and disposal ofsurplus excavated soil as directed, within a lead of 50 m. All kinds of soil HSR-4.14.1 |
| 2 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: Pipes, cables etc. exceeding 80 mm metre dia. but not exceeding 300 mm diaHSR-4.16.1.2 |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundationsetc.in layersnot exceeding20cmin depth, consolidatingeachdeposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. HSR-4.32 |
| 4 | Providing and injecting chemical emulsion for PRE- CONSTRUCTIONAL anti termitetreatmentandcreatingachemicalbarrierunderandaroundthecolumn pits,walltrenches,basementexcavation,topsurfaceofplinthfilingjunctionofwall andfloor,alongwiththeexternalperimetreofbuilding,expansionjointssurrounding ofpipesandconduitetc,complete(plinthareaofthebuildingatgroundflooronly shall bemeasured) using Chlorpyriphos/ Lindane emulsifiable concentrateof 20%. HSR-4.39 |
| 5 | Demolishing brick work manually/ by mechanical meansincludingstackingof serviceablematerialanddisposalofunserviceablematerialwithin50metresleadasper direction of Engineer-in-charge. In Cement mortar HSR-5.7.4 |
| 6 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: Of area 3sq. Meters and below HSR-5.29.1 |
| 7 | Providingandlayinginpositioncementconcreteofspecifiedgradeexcludingthe cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) HSR-6.1.2 |
| 8 | 1:4:8(1Cement:4coarsesand(zone-III):8gradedstoneaggregate40mm nominal size). HSR-6.1.6 |
| 9 | Providingandlayingdamp-proofcoursewithcementconcrete1:2:4(1cement: 2 coarsesand (zone-Ill): 4 graded stoneaggregate12.5mm nominal size). 50 mm thick. HSR-6.8.1 |
| 10 | Providing&applyingacoatofresidualpetroleumbitumenofgradeofVG-1Oof approvedqualityusing1.7kgpersquaremetreondampproofcourseaftercleaning thesurfacewithbrushesandfinallywithapieceofclothlightlysoakedinkerosene oil.HSR-6.10 |
| 11 | 20mmthickcementplasterdamp-proofcourse1:3with2coatsofbitumenat 1.65 kg. per sqm, laid hot and sanded: Vertical HSR-6.12.1 |
| 12 | Makingplinth protection50mmthickofcementconcrete1:3:6(1cement:3 coarsesand:6gradedstoneaggregate20mm nominalsize)over75mmthickbedof drybrickballast40mmnominalsize,wellrammedandconsolidatedandgrouted with finesand,includingnecessaryexcavation,levelling&dressing&finishingthe top smooth. HSR-6.13 |
| 13 | Providing and laying in position specified grade of reinforced cement concrete,excluding thecost of centering, shuttering, finishing and reinforcement-Allworkup toplinthlevel: 1:1.5:3(1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size) HSR-6.14.1 |
| 14 | Reinforcedcementconcreteworkinwalls(anythickness),includingattached pilasters, buttresses, plinth and string courses, fillets, columns, pillars,piers, abutments,postsandstrutsetc.aboveplinthleveluptofloorfourlevel,excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size) HSR-6.15.1 |
| 15 | Reinforcedcementconcreteworkinbeams,suspendedfloors,cumroofshaving slopeupto15°landings,balconies,shelves,chajjas,lintels,bands,plainwindow sills, staircases and spiral stair cases above plinth level up to floor four level, excludingthecostofcentering,shuttering,finishingandreinforcementwith1:1.5:3 (1 cement : 1.5 coarsesand(zone-III) : 3 graded stoneaggregate20 mm nominal size). HSR-6.16 |
| 16 | Centeringandshutteringincludingstrutting,proppingetc.andremovalofformfor: Foundations, footings, bases of columns, etc. for mass concrete. HSR-6.30.1 |
| 17 | Suspendedfloors,roofs,landings, balconies. HSR-6.30.3 |
| 18 | Shelves (Cast in situ). HSR-6.30.4 |
| 19 | Lintels,beams,plinthbeams,girders, bressumers and cantilever. HSR-6.30.5 |
| 20 | Columns,Pillars,Piers, Abutments, Posts and Struts. HSR-6.36.6 |
| 21 | Verticalandhorizontalfinsindividuallyorformingboxlouversband,faciasandeaves boards. HSR-6.30.13 |
| 22 | Edgesofslabsandbreaksin floors and walls.Under 20 cm wide. HSR-6.30.16.1 |
| 23 | Weathershade,Chanas,corbelsetc.,includingedges. HSR-6.30.19 |
| 24 | SteelreinforcementforR.C.C.work,wherenotincludedinthecompleterateof RCC,includingstraightening,cutting,bending,placinginposition,binding,wastage, overlaps,weldedjoints,spacerbars,chairs,stays,hangersandannealedsteelwire etc. completein all respect below plinth levelNote:- Reinforcement shall be measured in length including hooks, if any, separatelyfordifferentdiametersasactuallyusedinwork,excludingoverlaps. Wastage,overlaps,couplings,weldedjoints,spacerbars,chairs,stays,hangers and annealed steel wire or other methods of binding & placing shall not be measuredandcostoftheseitemsshallbedeemedtobeincludedintherates forreinforcement. Thermo-Mechanically Treated bars of grade Fe-500D ormore. HSR-6.33.6 |
| 25 | SteelreinforcementforR.C.C.work,wherenotincludedinthecompleterateof RCC,includingstraightening,cutting,bending,placinginposition,binding,wastage, overlaps,weldedjoints,spacerbars,chairs,stays,hangersandannealedsteelwire etc. completein all respect aboveplinth level.Note:- Reinforcement shall be measured in length including hooks, if any, separatelyfordifferentdiametersasactuallyusedinwork,excludingoverlaps. Wastage,overlaps,couplings,weldedjoints,spacerbars,chairs,stays,hangers and annealed steel wire or other methods of binding & placing shall not be measuredandcostoftheseitemsshallbedeemedtobeincludedintherates forreinforcement. Thermo-Mechanically Treated bars of grade Fe-500D or more. HSR-6.34.6 |
| 26 | ProvidingprecastcementconcreteJali1:2:4(1cement:2coarsesand(zone-11): 4gradedstoneaggregate6mmnominalsize),reinforcedwith1.6mmdiamildsteel wire,includingcenteringandshuttering,rougheningcleaning,fixingandfinishingin cementmortar1:3(1cement:3finesand)etc.complete,excludingplasteringofthe jambs, sills and soffits. 50mm thick HSR-6.49.1 |
| 27 | Brickworkwithcommonburntclaynon-modularbricksof class designation 10.5in foundation and plinth in:. Cement mortar 1:6 (1 cement: 6 coarse sand). HSR-7.21.2 |
| 28 | Brickworkwithcommonburntclaynon-modularbricksofclassdesignation10.5 in superstructureaboveplinth level up to floor IV level in all shapes and sizes in : Cement mortar 1:6 (1 cemennt: 6 coarse sand) HSR-7.22.2 |
| 29 | Halfbrickmasonrywithcommonburntclaynon-modularbricksof class designation 10.5 in superstructureaboveplinth level up to floor IV level. Cement mortar 1:4 (1 cement:4 coarse sand) HSR-7.28.2 |
| 30 | Extraforprovidingandplacinginposition2Nos.6mmdia.M.S.barsateverythirdcourseof half brick masonry. HSR-7.30 |
| 31 | Providingandfixing18mmthickgangsawcut,mirrorpolished,premoulded andprepolished,machinecutforkitchenplatforms,vanitycounters,window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick basecement mortar 1 :4 (1 cement : 4 coarsesand), joints treated with whitecement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to givehigh gloss finish etc. completeat all levels. Graniteofanycolourandshade.(Note:-Colour/ShadetobeapprovedbytheUniversity) Area of slab over 0.50 sqmHSR-8.26.2.2 |
| 32 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., includingmachinepolishingtoedgetogivehighglossfinishetc.completeasper design approved by Engineer-in-Charge. GraniteWork HSR-8.27.2 |
| 33 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platfonn, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. HSR-8.28 |
| 34 | Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnatedwithacoatofcoarsesandat60cudmper10sqm,includingcleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in keroseneoil complete With residual typepetroleum bitumen of gradeVG -10 HSR-9.10.1 |
| 35 | 10cmthick(average)mudphaskaofdampedbrickearthonroofslaidtoslope consolidatedandplasteredwith25mmthickmudmortarmixedwithbhusa@35kg percumofearthandgobrileapingwithmix1:1(1clay:1cowdung)andcovered withflattilebricks,groutedwithcementmortar1:3(1cement:3finesand)mixed with 2%of integral water proofing compound by weight of cement and finished neat:With common burnt clay non-modular brick tile of class designation 10 HSR-9.11.1 |
| 36 | Providinggola75x75mmincementconcrete1:2:4(1cement:2coarsesand:4 stoneaggregate10mmanddowngauge), includingfinishing withcement mortar1:3 (1 cement : 3 finesand) as per standard design : In75x75mmdeepchase HSR-9.17.1 |
| 37 | Providingandfixingtiledfalseceilingofspecifiedmaterialsofsize595x595mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consistingof main \"T\" runner with suitablyspacedjointstogetrequiredlengthandof size24x38mmmade from0.30mmthick(minimum)sheet,spacedat1200mm centretocentreandcross\"T\"ofsize24x25mmmadeof0.30mmthick(minimum) sheet,1200mmlongspacedbetweenmain\"T\"at600mmcentretocentretoforma gridof1200x600mmandsecondarycross\"T\"oflength600mmandsize24x25mm madeof0.30mmthick(minimum)sheettobeinterlockedatmiddleofthe1200x600 mmpaneltoformgridsof600x600mmandwallangleofsize24x24x0.3mmand layingfalseceilingtilesofapprovedtextureinthegridincluding,required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smokedetectorsetc.Main\"T\"runnerstobesuspendedfromceilingusingGIslotted cleats of size 27 x 37 x 25 x1 .6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dashfasteners,4mmGIadjustablerodswithgalvanisedbutterflylevelclipsofsize 85x30x0.8mmspacedat1200mmcentretocentrealongmainT,bottomexposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all completefor all heights asper specifications,drawings andas directedby Engineer-in charge.GIMetalCeilingLayinperforatedTegularedgeglobalwhitecolourtilesofsize 595x595mmand0.5mmthickwith 8mmdrop;madeofGIsheethaving galvanizing of100gms/sqm(bothsidesinclusive)and20% perforationareawith1.8mmdia holesandhavingNRC(NoiseReductionCoefficient) of0.5, electrostatically polyester powdercoatedofthickness60microns(minimum),includingfactorypaintedafter bending and perforation, and backed with a black Glass fibreacoustical fleece. HSR-9.47.2 |
| 38 | Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter HSR-9.57.2 |
| 39 | Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 O mm gap for thermal expansion Single push fit Coupler 75mm HSR-9.58.2.1 |
| 40 | Singler push fit Coupler 110 mm HSR-9.58.2.2 |
| 41 | Single tee with door75x75x75 mm HSR-9.58.3.1 |
| 42 | Single tee with door 110x110x110 mm HSR-9.58.3.2 |
| 43 | Single tee without door 75x75x75 mm HSR-9.58.4.1 |
| 44 | Single tee withour door 110x110x110 mmHSR-9.58.4.2 |
| 45 | Bend 87.5°75 mm bendHSR-9.58.5.1 |
| 46 | Bend 87.5° 110 mm bend HSR-9.58.5.2 |
| 47 | Shoe (Plain)75 mm Shoe HSR-9.58.6.1 |
| 48 | Shoe (Plain) 110 mm Shoe HSR-9.58.6.2 |
| 49 | ProvidingandfixingtotheinletmouthofrainwaterpipePTMT(anEngineering Thermoplastic) grating square (Slit) 150 mm square with a height of 8 mm and weighing not less than 100 gms. HSR-9.61 |
| 50 | Providingandlayingofbasecourseoffloorsconsistingof100mmthickcement1 :8: 16 and 100 mm sand or stonefilling. HSR-10.1 |
| 51 | Providingandlayingofscreedof50mmthickcementconcrete1:8:16tobelaid below thetopping. HSR-10.4 |
| 52 | Providingandlayingofchequeredprecastcementconcretetiles22mmthick in footpath & courtyard,jointedwithneatcementslurrymixedwithpigmentto matchtheshadeoftiles,includingrubbingandcleaningetc.complete,on20mm thick bed of cement mortar 1 :4 (1 cement: 4 coarsesand). Medium shadepigment using 50% white cement and 50% ordinary cement. HSR-10.30.2 |
| 53 | ProvidingandfixingofKotastoneslabflooringover20mm(average)thickbase laidoverandjointedwithgreycementslurrymixedwithpigmenttomatchtheshade oftheslab,includingrubbingandpolishingcompletewithbaseofcementmortar1: 4 ( 1 cement : 4 coarsesand) : 25mm thick HSR-10.37.1 |
| 54 | ProvidingandfixingofKotastoneslabs20mmthickinrisersofsteps,skirting, dadoandpillarslaidon12mm(average)thickcementmortar1:3(1skirting,dado andpillarslaidon12mm(average)thickcementmortar1:3(1cement:3coarse sand)andjointedwithgreycementslurrymixedwithpigmenttomatchtheshadeof theslabs, including rubbing and polishing complete. HSR-10.38 |
| 55 | Providingandfixingof40mmthickfinedressedstoneflooringover20 mm(average)thickbaseofcementmortar1:5(1cement:5coarsesand), includingpointingwithcementmortar1:2(1cement:2stonedust)withanadmixture of pigment to match the shade of stone. RedSandStone HSR-10.40.1 |
| 56 | Providingandfixing1stqualityceramicglazedwalltilesconforming to IS: 15622 (thickness to bespecified by themanufacturer ) of approved makein all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in whitecement mixed with pigment of matching shadecomplete. Note:-Tilesshallbeofpremiumquality(firstquality)ofreputedmanufacturer likeNITCO,KAJARIA,SOMANI,RAK,HINDWARE. HSR-10.58 |
| 57 | Cement Concrete 1 :8:16 Flooring Cement Concrete 1:8:16 with stone aggregate 40 mm size in cum foundation and plinth. HSR-10.100.2 |
| 58 | 10mmthickcementplaster1:3(1cement:3finesand) HSR-11.4.2 |
| 59 | 12mmcementplasterofmix: 1:6 (1 cement: 6 finesand) HSR-11.5.4 |
| 60 | 15mmcementplasterontheroughsideofsingleorhalfbrickwallofmix: 1:6(1 cement: 6 finesand) HSR-11.6.2 |
| 61 | SmoothfinishingoftheexposedsurfaceofR.C.C.workwith10mmthickcement mortar 1 :3 (1 Cement : 3 fine sand). HSR-11.50 |
| 62 | Providingandapplyingtwocoatswhitecementbasedputtyofapprovedbrand andmanufacturer,overplasteredsurfaceandgrindingthesurfacesmoothwithsand papertogetenevenandsmoothfinishincludingcostandcarriageofallmaterial, labour charges, scaffolding, sundries etc. complete HSR-11.58 |
| 63 | Distemperingwithoilboundwashabledistemperofapprovedbrandandmanufacturetogiveanevenshade: Newwork(twoormorecoats) over and including water thinnable priming coat with cement primer HSR-11.64.1 |
| 64 | Applyingprimingcoat: Withreadymixedredoxidezinc chromateprimer of approved brand and manufactureon steel galvanised iron/ steel works HSR-11.68.3 |
| 65 | Painting two coats excluding priming coat with synthetic enamel paint in all shadesonnewwoodworkormetallicorplasteredorconcretesurfacestogiveaneven shade. HSR-11.78 |
| 66 | FinishingwallswithAcrylicSmoothexteriorpaintofrequiredshade: Newwork(Twoormorecoatapplied @ 1.67 litre/1 O sqm over and includingpriming coat of exterior primer applied @ 2.20 kg/10 sqm). HSR-11.95.1 |
| 67 | Providingwoodworkinframesoffalseceiling,partitionsetc.sawnandfixedinposition with necessary stainless steel screws etc. KilnseasonedandchemicallytreatedHollockwood HSR-12.4.2 |
| 68 | Providing&Fixingdecorativehighpressurelaminatedsheetof plain/woodgrain ingloss/matt/suedefinishwithhighdensityprotectivesurfacelayerandreverse sideofadhesivebondingqualityconformingtoIS:2046TypeS,includingcostof adhesiveof approved quality.(Note:-Colour/ShadeandcompanytobeapprovedbytheUniversity) 1.0mmthickHSR-12.12.2 |
| 69 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) HSR-12.15 |
| 70 | ProvidingandfixingISimarkedflushdoorshuttersconformingtoIS:2202(Part I)non-decorativetype,coreofblockboardconstructionwithframeof1stclasshard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and faceveneers on both faces of shutters: HSR-12.3735mmthick including ISi marked Stainless Steel butt hinges with necessary screwsHSR-12.37.1 |
| 71 | 30mmthick including ISi marked Stainless Steel butt hinges with necessary screwsHSR-12.37.2 |
| 72 | Extraforprovidinglippingwith2ndclassteakwoodbattens25mmminimum depth on all edges of flush door shutters (over all area of door shutter to bemeasured). HSR-12.39 |
| 73 | Providingandfixingaluminiumdiecastbodytubulartypeuniversalhydraulic doorcloser(havingbrandlogowithISi,IS:3564,embossedonthebody,door weightupto35kganddoorwidthupto700mm),with necessaryaccessoriesand screws etc. complete. HSR-12.88 |
| 74 | Providingandfixingaluminiumextrudedsection bodytubular typeuniversal hydraulicdoorcloser(havingbrandlogowithISi,IS:3564,embossedonthebody, door weight upto36kgto80kganddoorwidthfrom701mmto1000mm), with double speed adjustment with necessary accessories and screws etc. complete. HSR-12.89 |
| 75 | Providingandfixingaluminiumslidingdoorbolts,ISImarkedanodised(anodiccoatingnotlessthangradeAC10asperIS:1868),transparentordyedtorequired colour or shade, with nuts and screws etc. complete:250 x 16 mm HSR-12.98.2 |
| 76 | Providingandfixingaluminiumtowerbolts,ISImarked,anodised(anodiccoatingnot lessthan gradeAC10asper IS: 1868) transparentor dyedtorequiredcolour or shade, with necessary screws etc. complete. 200 x 10 mm HSR-12.99.3 |
| 77 | 150 x 10 mm HSR-12.99.4 |
| 78 | 100 x 10 mm HSR-12.99.5 |
| 79 | Providingandfixingaluminiumhandles,ISImarked,anodised(anodiccoatingnot lessthangradeAC1OasperIS:1868)transparentordyedtorequiredcolourorshade, with necessary screws etc. complete. 125 mm HSR-12.102.1 |
| 80 | 100 mm HSR-12.102.2 |
| 81 | Providingandfixingaluminiumhangingfloordoorstopper,ISImarked,anodised (anodiccoatingnotlessthangradeAC10asperIS:1868)transparentordyedto required colour and shade, with necessary screws etc. complete. Twin rubber stopper HSR-12.103.2 |
| 82 | Providingandfixingaluminiumworkfordoors,windows,ventilatorsand partitionswithextrudedbuiltupstandardtubularsections/appropriateZsections andothersectionsofapprovedmakeconformingtoIS:733andIS:1285,fixingwith dashfastenersofrequireddiaandsize,includingnecessaryfillingupthegapsat junctions,i.e.attop,bottomandsideswithrequiredEPDMrubber/neoprenegasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanicallywhereverrequiredincludingcleatangle,Aluminiumsnapbeadingfor glazing/panelling,C.P.brass/stainlesssteelscrews,allcompleteasper architecturaldrawingsandthedirectionsofEngineer-in-charge.(Glazing,panelling and dash fasteners to bepaid for separately) : Forfixedportion Polyester powder coated aluminium (minimum thickness of polyester powdercoating 50 micron) HSR-12.157.1.3 |
| 83 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivotsandmakingprovisionforfixingoffittingswhereverrequiredincluding the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). Polyester powder coated aluminium (minimum thickness of polyester powdercoating 50 micron) HSR-12.157.2.3 |
| 84 | Providingandfixingglazinginaluminiumdoor,window,ventilatorshuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architecturaldrawingsandthedirectionsofengineer-in-charge.(Costofaluminium snap beading shall bepaid in basic item): Withfloatglasspanesof6mmthickness(weight not less than 15 kg/sqm) HSR.12.159.3 |
| 85 | Providingandfixingstainlesssteel(SS304grade)adjustablefrictionwindows staysofapprovedqualitywithnecessarystainlesssteelscrewsetc.tothesidehung windows as per direction of Engineer-in-charge complete. 355X19mm HSR-12.162.3 |
| 86 | Providingandfixingaluminiumcasementwindowsfastenerofrequiredlengthforaluminium windows with necessary screws etc. complete. Polyesterpowdercoatedminimum thickness 50 micron aluminium. HSR-12.166.3 |
| 87 | Fillingthegapinbetweenaluminium/stone/woodframeandadjacent RCC/Brick/Stone/wood/Ceramic/Gypsumworkbyprovidingweather/structural nonsagelastomericPUsealantoverbackerrodofapprovedqualityasper architectural drawings and direction ofEngineer-in-charge complete, complyingto ASTM C920, DIN 18540-F & ISO 11600. HSR-12.172. Upto5mmdepthand 5 mm width. HSR.12.172.1 |
| 88 | Upto10mmdepthand 10 mm width. HSR-12.172.2 |
| 89 | Steelworkweldedinbuiltupsections/framedwork,includingcutting,hoisting, fixing in position and applying a priming coat of approved steel primer usingstructural steel etc. as required. Ingratings,frames,guardbar,ladder,railings, brackets, gates and similar works HSR-13.29.2 |
| 90 | Cutting holes up to 23 cm through stone masonry or brick work in cement walls for pipes and making good including repointing, replastering and finishing according to existing finish where required. 11.43 cm thick wall HSR-20.26.1 |
| 91 | 22.86 cm thick wall HSR-20.26.2 |
| 92 | Making connection with the existing G.I. branch main up to 40 mm size including cutting and threading pipe etc., complete excluding cost of tee and long screw, but including cartage of material to site. HSR-20.36 |
| 93 | Bailing out water from the trenches for making new connections in fully charged pipe-lines including cleaning trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. Up to 200 mm internal diametre HSR-20.49.1 |
| 94 | Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge. 250 mm i/d HSR-20.62.2 |
| 95 | Lowering salt glazed stoneware pipes and specials into trenches for all depths and laying out the same to correct alignment gradient, level etc in trenches including all dressing and trimming of bed and sides of trenches, if required, trimming and cutting of concrete beds and joint holes, supporting the pipes and specials, in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benching hunching and envelopes are completed. The sewer shall rest on the bed at every point throughout its length and to ensure this, it shall be grouted in without extra charge by the contractor with lime surkhi mortar, in the case of lime concrete beds and 1 :3 cement sand mortar in the case of cement concrete beds including cartage from Divisional Store or nearest Railway station to site of work. The internal diameter of sewer being : 150 mm internal diameter of sewer HSR-21.38.2 |
| 96 | 200 mm internal diameter of sewer HSR-21.38.4 |
| 97 | Notes: The rates include all bricks and supports for the sewer and also all sight and appliances to ensure that the sewer is maintained to perfect alignment and gradients throughoul Jointing and fixing salt glazed stoneware pipes and special in trenches using cement sand mortar 1 :1 and best white Italian tarred hemp/yam including finishing and trowel ling of each joint at an angle of 45 degrees with the longitudinal axis of the pipes, watering, keeping the joints covered and wetted till the same are cured, testing the sewer lines for leakages and making all leakages and defect good, complete as laid down in the contract specifications. HSR-21.39.150 mm internal diametre of sewer HSR-21.39.2 |
| 98 | 200 mm internal diametre of sewer HSR-21.39.4 |
| 99 | Cutting glazed stoneware pipes and specials chipping and finishing the cut surface to a uniform finish and roughing the part of the pipes, if any entering the sockets of the adjacent pipes complete, to the satisfaction of the engineer-in-charge of the works. HSR-21.40150 mm internal diametre of pipes HSR-21.40.2 |
| 100 | 200 mm internal diametre of pipes HSR-21.40.4 |
| 101 | Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benching 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. toppingHSR-21.84.1 |
| 102 | Size 450 mm X 600 mm inside (with 455 mm x 610 mm cover and frame single seal pattern I weighing 38 kg with C.C. topping) HSR-21.84.2 |
| 103 | Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) HSR-21.84.3 |
| 104 | Providing salt glazed stone ware pipes grade \"A\" in standard length of 600 mm each pipe marked with IS: 651 and their lowering, cutting, jointing and testing as described in item No. 21.38, 21.39, item 21.40 induding the cost of jointing materials as well as carriage, loading, unloading, stacking, handling, re-handling etc. complete in all respects to the satisfaction of Engineer-in-charge. 150mm i/dHSR-21.94.2 |
| 105 | 200mm i/dHSR-21.94.3 |
| 106 | Making holes for HCL soil / Waste pipe by core cutting up to 200 mm thick slabs and sealing with Drip seal sealant complete in all respect.100 mm dia pipeHSR-21.100.2 |
| 107 | Providing and fixing MS Angle 35 x 35 x 5 mm with 10 mm MS Threaded rods & Fastener & Fixture to Support the Cl and PVC Pipe. HSR-21.101 |
| 108 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm diaHSR-22.14.2.1 |
| 109 | Providing and fixing in position C.I. plain Nahani Trap conforming to I.S.I. specifications and of self cleaning design with C.P. brass hinged grating with frame complete. With 75 mm internal diameter outlet HSR-22.20.2 |
| 110 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests HSR-22.22.1 |
| 111 | Providing and fixing white vitreous chinaware extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous chinaware cistern / PVC cistern (with brass fitting) into the wall with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. HSR-22.33 |
| 112 | Providing and fixing 8 mm dia C.P. I S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. HSR-22.38 |
| 113 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls. For 100 mm dia pipe HSR-22.53.1 |
| 114 | For 75 mm dia pipe HSR-22.53.2 |
| 115 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes HSR-22.85.3 |
| 116 | 32 mm nominal outer dia Pipes HSR-22.85.4 |
| 117 | 40 mm nominal outer dia Pipes HSR-22.85.5 |
| 118 | 50 mm nominal outer dia Pipes HSR-22.85.6 |
| 119 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal outer dia Pipes HSR-22.86.2 |
| 120 | 25 mm nominal outer dia Pipes HSR-22.86.3 |
| 121 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. 50 mm dia nominal bore HSR-22.91.6 |
| 122 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm nominal bore HSR-22.98.1 |
| 123 | 20 mm nominal bore HSR-22.98.2 |
| 124 | 32 mm nominal bore. HSR-22.98.3 |
| 125 | 40 mm nominal bore HSR-22.98.4 |
| 126 | 50 mm nominal bor HSR-22.98.5 |
| 127 | Providing and fixing Unplasticised PVC connection pipe with brass unions: 15 mm nominal bore HSR-22.101.2.1 |
| 128 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 150 mm diameter HSR-22.102.2 |
| 129 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: 15 mm nominal bore HSR-22.104.1 |
| 130 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore HSR-22.106.1 |
| 131 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore HSR-22.107.1 |
| 132 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore HSR-22.108.1 |
| 133 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) ofapproved make and quality as per direction of Engineer-in-charge.HSR-22.109 |
| 134 | Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal borePTMT FITTINGSHSR=22.110.1 |
| 135 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 36 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms HSR-22.115.2 |
| 136 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. HSR-22.117 |
| 137 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. HSR-22.118 |
| 138 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. HSR-22.119.2 |
| 139 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mmheight of approved quality and colour, weighing not less than 300 gms. HSR-22.120 |
| 140 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. HSR-22.127 |
| 141 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 150 x 100 mm size P type With common burnt clay non-modular bricks of class designation 7 .5 HSR-22.166.2.1 |
| 142 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.HSR-22.181 |
| 143 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (ofapproved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. HSR-22.209 |
| 144 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 630mm x 500mm (above counter oval) HSR-22.221.8 |
| 145 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.110mm old SWR UPVC pipe lines laid complete HSR-22.222.2.2 |
| 146 | 90mm old SWR UPVC pipe lines laid complete HSR-22.222.2.3 |
| 147 | Providing and laying water proofing treatment in sunken portion of WCs, bathroometc.,byapplyingcementslunymixedwithwaterproofingcement compound consisting of applying:(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/ sqm This layer will beallowed to air curefor 4 hours.(b)[email protected]/sqmmixedwithwaterproofing [email protected]/sqmThislayerwillbeallowedtoaircurefor4hours followed with water curing for 48 hours.Therateincludespreparationofsurface,treatmentandsealingofalljoints,corners, junctions of pipes and masonry with polymer mixed slurry.The rate includes preparation ofsurface, treatment and sealing of all joints, corners,junctionsofpipesandmasonrywithpolymermixedslurry. HSR-28.15 |
| 148 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1 :2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1 :3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter HSR-30.88.1 |
| 149 | For pipes 250 to 300 mm diameter HSR-30.88.2 |
| 150 | Chippingofunsound/weakconcretematerialfromslabs,beams,columnsetc. with manual Chisel and/ or by standard power driven percussion typeor of approved makeincluding tapering of all edges, making squareshoulders of cavities including cleaning theexposed concretesurfaceand reinforcement with wirebrushes etc. and disposal of debris for all lead and lifts all completeas per direction of Engineer-In- Charge. 25mmaveragethicknessHSR-31.2.3 |
| 151 | Providing,mixingandapplyingbondingcoatof approved adhesiveon chippedportion of RCC as per specifications and direction of Engineer-In-charge completein all respect. Epoxybondingadhesive having coverage2.20 sqm/kg of approved makeHSR-31.4.2 |
| 152 | Rebarringworkwith10mlinjectablemortarepoxyadhesive(HybridUrethane Methacrylateadhesive)orchemicalcompoundofmakeasapprovedbyEngineer-in- Charge completein all respect including drilling and cost of all materials.8mmdia (hole size 12 mm dia & depth up to 80 mm) HSR-31.14.1 |
| 153 | 10mmdia (hole size 14 mm.& hole depth up to 100 mm) HSR-31.14.2 |
| 154 | 12mmdia (hole size 16 mm.& hole depth up to 120 mm) HSR-31.14.3 |
| 155 | 16mmdia (hole size 20 mm.& hole depth up to 200 mm) HSR-31.14.4 |
| 156 | 20mmdia (hole size 24 mm.& hole depth up to 240 mm) HSR-31.14.5 |
| 157 | Supplyof NTC Precast rest Benches 1500(L)X450(W)X1000(H) (N.S Items) |
| 158 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUITWiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group A HSR-23.4.1.1 |
| 159 | Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as RequiredGroup A HSR-23.4.4.1 |
| 160 | Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthing , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group A HSR-23.4.5.1 |
| 161 | FITTING AND ACCESSORIES Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.HSR-23.9 |
| 162 | Supply, erection and fixing of 12 mm thick ply wood board having a circular/rectangular hole etc as required including the cost of making hole, nuts and bolts, painting and other petty material with all labour etc. complete in all respect up to the entire satisfaction of Engineer-in-charge of the work.HSR-23.13 |
| 163 | Fixing of LED Tube light/ 2*2 ft square panel fitting directly on wall /ceiling or false ceiling including making connections etc as requiredHSR-23.2 |
| 164 | MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratingsMCCB up to 125 A FP HSR-23.22.2.1 |
| 165 | MCCB ,DISTRIBUTION BOARDS, MCB\"s, RCCB\"s, CHANGE OVER etc. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work.TPN DB Horizontal type Double Door 4 way ( 8 incoming 3phase*4 outgoing)HSR-23.22.4.5 |
| 166 | Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single PoleHSR-23.22.5.1 |
| 167 | 6 amp to 32 amp. MCB\"s FOUR POLEHSR-23.22.5.7 |
| 168 | Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.4 pole MCCB 6 amp to 100 amp HSR-23.22.1.9 |
| 169 | Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 100X50 X2mm HSR-23.23.6.1 |
| 170 | Supply and erection of cable tray cover made of 1.25mm thick GI sheet as required including erection of the same on existing cable tray with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. GI cable tray Cover, suitable for cable tray of 100 X50X2mmHSR-23.23.7.1 |
| 171 | Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. HSR-24.1.3 |
| 172 | Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode.HSR-24.1.5 |
| 173 | Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required.HSR-24.1.7 |
| 174 | Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material.HSR-24.1.8 |
| 175 | Supply and erection of suitable compression type brass cable glands for underground Cable :- 10 sqmm to 16 sqmm Cable 2 to 4 CoreHSR-24.2.7.2 |
| 176 | Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work .16 sqmm HSR-24.2.8.4 |
| 177 | Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suitable size of rag bolts with cement concrete, duly painted with three coats of approved paint including one coat of red oxide. HSR-23.24.1 |
| 178 | S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia HSR-24.5.2.3 |
| 179 | Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 48\" (1200mm)with BEE 5 star rating Make Orient , Havells, Cromptonwith 2 year warranty HSR-20.71.1 |
| 180 | Providing and fixing granite stone in all shades 15mm to 18 mm thick in skirting /dado, risers of steps, pillars and wall facing, laid in any pattern as specified over base of 12mm thick cement coarse sand mortar 1 :3 and jointed with white cement slurry mixed with pigment to match the shade of Granite including labour for fixing cramps pins and dowels etc.HSR-10.51 |
| 181 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnablepriming coat with cement primerHSR-11.64.1 |
| 182 | Supply & laying of underground cable in pipe/existing open/closed trench etc. as required. Make- Havells/ Grandlay/ Polycab/ RR Kabel/ KEI 35 sq. mm 4 Core Cable (Ard.) NS item |
| 183 | Supply & erection of Bulkhead light 10 W Make Havells, Philips, Wipro with warranty 2year& all new latest updated specification Complete in all respect up to the entire satisfaction of Engineer - in charge of the work. NS item |
| 184 | Supply& erection ofEXHAUST FAN (12\"=300mm)with double ball barring Make Havells, Orient, Cromptionwith warranty 2year& all new latest updated specification Complete in all respect up to the entire satisfaction of Engineer - in charge of the work.NS item |
| 185 | Supply & erection of Louvers for 12” Exhaust FansComplete in all respect up to the entire satsfaction of Engineer - in charge of the work.NS item |
| 186 | Supply and erection of of 40 W LED Batton Make Havells, Philips, Wipro with warranty 2year& all new latest updated specification Complete in all respect up to the entire satisfaction of Engineer - in charge of the work. NS item |
| 187 | Supply, Installation, Testing & Commissioning ofElevator Type Passenger elevator PWI15 / 10-19 Product IMonospace No of Units 1 Load & Capacity 1020 kg or 15 persons Speed 1 m/s Stops & Openings 3 stops & 3 openings, Single entrance car Travel height 8 m Elevator Grouping Simplex Full Collective Control Well Dimension 2280 mm width and 2000 mm depth (required) Head Room height 4500 mm (required) Pit Height 1600 mm (required) MAP Floor Position Topmost floor (TOP) Car dimensions 1600 mm wide x 1500 mm deep x 2200 mm high Door dimensions 900 mm wide x 2000 mm internal height Door type Two-panel centre opening Plain Panel Finishes Car design SS silver brushed Car Panel Finish Stainless steel Hairline AISI441 Handrail Round Bend Handrail Silver brushed stainless steel (ST4) at Rear Wall Ceiling & Lighting Integrated roof LS4 Stainless Steel Square Spot Light LED Flooring 20 mm recess on flooring granite by customer Car skirting material: Stainless steel Hairline AISI441 Car Door Finish Stainless steel Hairline AISI441 Floor number Floor Mark Interfloor distance Landing door material 1-3 0, 1, 2 4000 mm Stainless steel AISI441 Car operating panel 1 Full Height Stainless Steel Face Plate Silver brushed StSt Segmented LCD display Square surface mounted Buttons with braille KDS90 Landing Signalization Stainless Steel 7 segment display Surface Mounted Silver brushed StSt Square,surface mounted with braille KDS90 Features Standard Correction drive to next level Emergency Alarm @ Main Floor Car Call backwards Overload function, constant indication/Buzzer Bypass load Function Auto Cut off Fan and Light Manual Rescue Operation Centralized Hoisting for lesser vibration and smooth travel Pit Ladder Micro movement Led Based Buttons L.W.D. (Load Weighing Device) Direction & Position Indicator In Car & Landing Advanced Car Position Indication Automatic Brake Test function every 11hours Every run brake supervision Phase reversal functioning Signal Fixtures +10% to –10% Voltage Fluctuation Withstanding Capacity Door Close Button Door Open Button Car Emergency Light Fireman Drive Curtain of Light 169 Beams Accurate Relevelling, Automatic, Closed Door E, With emerg.opening device Additional Emergency Rescue Device with audio announcer 2 Way Dedicated Intercom Attendant Service Parking Predefined floor - Doors closed Lift Announcer Square Spot Light LED Access Control Provision B, 2 Hours Fire ratedMake:-SCHEINDER / MITSUBISHI/ KONE. OTIS / ORBISNS item |
| 188 | Supply, Installation, Testing & Commissioning of Basic elevator data Elevator Type Passenger elevator PWI06/10-19 Product IMonospace No of Units 1 Load & Capacity 408 kg or 6 persons Speed 1 m/s Stops & Openings 2 stops & 2 openings, Single entrance car Travel height 4 m Elevator Grouping Simplex Full Collective Control Well Dimension 1800 mm width and 1600 mm depth (required) Head Room height 4500 mm (required) Pit Height 1600 mm (required) MAP Floor Position Topmost floor (TOP) Car dimensions 1100 mm wide x 1000 mm deep x 2200 mm high Door dimensions 800 mm wide x 2000 mm internal height Door type Two-panel centre opening Plain Panel Finishes Car design SS silver brushed Car Panel Finish Stainless steel Hairline AISI441 Handrail Round Bend Handrail Silver brushed stainless steel (ST4) at Rear Wall Ceiling & Lighting Integrated roof LS4 Stainless Steel Square Spot Light LED Flooring 20 mm recess on flooring- granite by customer Car skirting material: Stainless steel Hairline AISI441 Car Door Finish Stainless steel Hairline AISI441 Floor number Floor Mark Interfloor distance Landing door material 1-2 0, 1 4000, mm Stainless steel AISI441 Car operating panel 1 Full Height Stainless Steel Face Plate Silver brushed StSt Segmented LCD display Square surface mounted Buttons with braille KDS90 Landing Signalization Stainless Steel 7 segment display Surface Mounted Silver brushed StSt Square,surface mounted with braille KDS90 Signed For Purchaser For KONE Elevator India Pvt Ltd 7(28) Features Standard Correction drive to next level Emergency Alarm @ Main Floor Car Call backwards Overload function, constant indication/Buzzer Bypass load Function Auto Cut off Fan and Light Manual Rescue Operation Centralized Hoisting for lesser vibration and smooth travel Pit Ladder Micro movement Led Based Buttons L.W.D. (Load Weighing Device) Direction & Position Indicator In Car & Landing Advanced Car Position Indication Automatic Brake Test function every 11hours Every run brake supervision Phase reversal functioning Signal Fixtures +10% to –10% Voltage Fluctuation Withstanding Capacity Door Close Button Door Open Button Car Emergency Light Fireman Drive Curtain of Light 169 Beams Accurate Relevelling, Automatic, Closed Door E, With emerg.opening device Additional Emergency Rescue Device with audio announcer 2 Way Dedicated Intercom Attendant Service Parking Predefined floor - Doors closed Lift Announcer Square Spot Light LED Access Control Provisio Make:-SCHEINDER / MITSUBISHI/ KONE. OTIS / ORBISNS item |
| 189 | Supply, Installation, Testing & Commissioning ofBasic elevator data Elevator Type Passenger elevator PWI10/10-19 Product IMonospace No of Units 1 Load & Capacity 680 kg or 10 persons Speed 1 m/s Stops & Openings 3 stops & 3 openings, Single entrance car Travel height 8 m Elevator Grouping Simplex Full Collective Control Well Dimension 1900 mm width and 1800 mm depth (required) Head Room height 4500 mm (required) Pit Height 1600 mm (required) MAP Floor Position Topmost floor (TOP) Car dimensions 1300 mm wide x 1350 mm deep x 2200 mm high Door dimensions 800 mm wide x 2000 mm internal height Door type Two-panel centre opening Plain Panel Finishes Car design SS silver brushed Car Panel Finish Stainless steel Hairline AISI441 Handrail Round Bend Handrail Silver brushed stainless steel (ST4) at Rear Wall Ceiling & Lighting Integrated roof LS4 Stainless Steel Square Spot Light LED Flooring 20 mm recess on flooring- granite by customer Car skirting material: Stainless steel Hairline AISI441 Car Door Finish Stainless steel Hairline AISI441 Floor number Floor Mark Interfloor distance Landing door material 1-3 0, 1, 2 4000 mm Stainless steel AISI441 Car operating panel 1 Full Height Stainless Steel Face Plate Silver brushed StSt Segmented LCD display Square surface mounted Buttons with braille KDS90 Landing Signalization Stainless Steel 7 segment display Surface Mounted Silver brushed StSt Square,surface mounted with braille KDS90 Signed For Purchaser For KONE Elevator India Pvt Ltd 10(28) Features Standard Correction drive to next level Emergency Alarm @ Main Floor Car Call backwards Overload function, constant indication/Buzzer Bypass load Function Auto Cut off Fan and Light Manual Rescue Operation Centralized Hoisting for lesser vibration and smooth travel Pit Ladder Micro movement Led Based Buttons L.W.D. (Load Weighing Device) Direction & Position Indicator In Car & Landing Advanced Car Position Indication Automatic Brake Test function every 11hours Every run brake supervision Phase reversal functioning Signal Fixtures +10% to –10% Voltage Fluctuation Withstanding Capacity Door Close Button Door Open Button Car Emergency Light Fireman Drive Curtain of Light 169 Beams Accurate Relevelling, Automatic, Closed Door E, With emerg.opening device Additional Emergency Rescue Device with audio announcer 2 Way Dedicated Intercom Attendant Service Parking Predefined floor - Doors closed Lift Announcer Square Spot Light LED Access Control Provision B, 2 Hours Fire ratedMake:-SCHEINDER / MITSUBISHI /KONE. OTIS/ORBISNS item |
| 190 | Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge48\" (1200mm)HSR-20.71.1 |
| 191 | Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge.HSR-21.20.72 |
| 192 | Providing and fixing in position best Indian make (to the approval of the engineer-in-charge) storage type automatic electric water heater, pressure/non-pressure type thermostatically controlled, suitable for operation on 230 volts, 50 cycles single phase vertical wall mounting fitted with-draw able and adjustable type AC, thermostat. Thermostat knob to be readily accessible through the opening of suitable cover for and adjustment of temperature in the installed position of heater and the thermostat should be withdrawn without having to drain the water, electric heating element made out of copper tube (heating element should be easily removed and replaced in the installed position of heater) A neon indicator 1 AMP, inner container made out of copper tinned both from inside and outside, outer container made out of mild steel sheet finished in gleaming white stove enamel paint, insulated between the inner and outer with fibre glass wool with 1 metre length of suitable capacity 3 core flexible cord with plug and non return valve plastic/lead connections or pressure release valve (where required). Complete including fixing and testing for a week (as required by Engineer-in-charge.25 Litres capacity HSR-22.216.1 |
| 193 | 50 Litres capacity |
| 194 | Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required.1 run of Size 1.50 Sqmm(1/1.40mm) (For Sub Mains SB to SB 24-10(14x15)=210+ Misc Jobs90 =300 ) HSR-2123.3.6.1 |
| 195 | 1 run of Size 2.50 Sqmm(1.1.80mm) (For Sub MainDB to SB with Plug (10x15+ Misc Jobs50 =200mtr)HSR-2123.3.6.2 |
| 196 | 1 run of Size 4 Sqmm(1/2.24mm)( For Misc Jobs ) HSR-2123.3.6.3 |
| 197 | 1 run of Size 6 Sqmm(1/2.80mm) (For DB Earthing ) HSR-2123.3.6.4 |
| 198 | 1 run of Size 10 Sqmm(1/3.50 mm) 2x25( Sub Mains to 8 Way horizontal DB\"s =50 HSR-2123.3.6.5 |
| 199 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C(ceiling fan 2+Ex fan 16+1x18W Tube lights 70 + Wall Lights 4+ Mirror lights 15+ 2x2 Lights 6 =113-13-4=96HSR-23.4.1.3 |
| 200 | Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.Group C HSR-23.4.2.3 |
| 201 | Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch.Group C( Without Seprate Switch)(113-100+44=57)HSR-23.4.3.3 |
| 202 | Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required. Group C(for Light Plugs =4)HSR-23.4.4.3 |
| 203 | Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required. Group C(for Gyeser Points 15 + Power Plugs12=27) HSR-23.4.5.3 |
| 204 | Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall /ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work.PVC pipe of 20 mm dia.( For Misc Jobs )HSR-23.7.6.1 |
| 205 | PVC pipe of 25 mm dia. ( For Misc Jobs )HSR-23.7.6.2 |
| 206 | PVC pipe of 32 mm dia.(For Supply Cables) HSR-23.7.6.3 |
| 207 | PVC pipe of 40 mm dia.(For Supply Cables)HSR-23.7.6.4 |
| 208 | FITTING AND ACCESSORIESProviding and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessaryconnections, complete in all respect.Ceiling rose flush/surface type (For Ex fans)HSR-23.8.1.5 |
| 209 | Call bell 220/230 volts musical type HSR-23.8.1.6 |
| 210 | Bakelite angle/straight button holder large size.(For Bracket Lights4+ Mirror Lights 15=19)) HSR-23.8.1.12 |
| 211 | Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelitesheet as below75 mm x 75 mm x 60 mm deep M.S. box for inter-communication system HSR-23.8.3.1 |
| 212 | Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cmlong M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.. |
| 213 | Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.1 & 2 Modules (For Misc Jobs) HSR-23.8.10.1 |
| 214 | 3 Modules(For Misc Jobs) HSR-23.8.10.2 |
| 215 | 4 Modules(For Misc Jobs) HSR-23.8.10.3 |
| 216 | 6 Modules(ForMisc Jobs) HSR-23.8.10.4 |
| 217 | 8 Modules (ForMisc Jobs) HSR-23.8.10.5 |
| 218 | Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (for plug on SB 24+7 =31)HSR-23.8.11.1 |
| 219 | 5 amp 2 way switch (Misc)HSR-23.8.11.2 |
| 220 | 15 amp 1 way switch )(Misc)HSR-23.8.11.3 |
| 221 | 5 amp Socket ( Plug on SB 24=24+7=31) HSR-23.8.11.4 |
| 222 | 15 amp 6 pin Socket( Misc)HSR-23.8.11.5 |
| 223 | Step type Fan Regulator 2 modules 300 wattHSR-23.8.11.7 |
| 224 | Blanking plateHSR-23.8.11.10 |
| 225 | Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.HSR-21.23.9 |
| 226 | Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless steel wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as requiredHSR-21.23.11 |
| 227 | Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required HSR-21.23.12 |
| 228 | Fixing of LED Tube light 1x18 / 2*2 ft square Lightfitting directly on wall /ceiling or falseceiling including making connections etc as required HSR-2123.20 |
| 229 | Supply and erection of sheet steel enclosures 1 pole/2 pole/4 pole on wall on existing pedestal complete as required S.P.N. or DP enclosure suitable for DP MCB( Misc) HSR-23.22.3.2 |
| 230 | TPN enclosure suitable for TP , TPN or FP MCB( Misc) HSR-23.22.3.3 |
| 231 | Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing)( For supply distribution at each floor)HSR-21.23.22.4.2 |
| 232 | Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:-6 amp. to 32 amp single pole. (For 8 way SPN DB,s)(2x6=12) HSR-23.22.5.1 |
| 233 | 40 amp. to 63 amp double pole.( For incoming of 8 way SPN DB,s)=2x1=2HSR-23.22.5.4 |
| 234 | Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 40 A( For 8way SPNDB incomings 2x1=2) HSR-23.22.6.2 |
| 235 | Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work.25x 12 mm HSR-23.23.5.1 |
| 236 | 50x 50 mmHSR-23.23.5.4 |
| 237 | Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.HSR-24.1.3 |
| 238 | Extra for charcoal or coke and salt for G. I. plate or copper plate earthelectrode.HSR-24.1.5 |
| 239 | Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess forconnections etc. as required with all labour and material.HSR-24.1.8 |
| 240 | Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.HSR-24.1.13 |
| 241 | Laying of underground cable 0. 75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 50 Sq mm to 150 sqmm 2 to 4 Core HSR-24.2.2.3 |
| 242 | Laying and fixing of cable on surface/ cable tray etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core (Incoming to SPN DB)HSR-24.2.5.2 |
| 243 | Supply and erection of suitable compression type brass cable glands for underground Cable :-10 sqmm to 16s qmm Cable 2 to 4 CoreHSR-24.2.7.2 |
| 244 | 70 sqmm to 95 sqmm Cable 3 to 3½ CoreHSR-24.2.7.4 |
| 245 | Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work .16 sqmm HSR-24.2.8.4 |
| 246 | 70sqmmHSR-24.2.8.8 |
| 247 | SITCSurface MountedBracket/wall light . The Fixture should be Made of chrome&metal Housing.PF>.95, System Wattage 10Ww with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-BAJAJ (BCLSB10NW) / HAVELLS (LUMILINEBS10WLED 865 SPC WH / CGL (CCS-103-10-65-SL-DP-NWH)/GE/OSRAM /WIPRO/PHILIPS |
| 248 | SITC1x18W or 18/20W LED1200mm Batten Light. The Endura Fixture is a surface & wall mounted LED batten with extruded aluminium housing and robust construction . PF>.95, System Wattage LED 20W with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-PHILIPS ( BN308C LED20S-6500 L120 PSU WH)/BAJAJ(BCLABSP22L LED CW PC SD) /GE/OSRAM/CGL/Havells ( LUMILINE SMART 20W LED 865PC WH). |
| 249 | SITC5/6/9W LEDaesthetically brillient surface picture/mirror light. The Fixture comprisesofaluminium /policarbonate . PF>.95, System Wattage LED 5/6/9W with Minium 100 lumens/W in 5700k . The Fixture should be of Makes :-BAJAJ(BCLSB 05 NW) /Havells(LUMILINE BS 9W LED 865 SPC WH) /CGL(CCS-103-05-65-SL-DP=NWH)/ GE/OSRAM/ PHILIPS etc.) |
| 250 | SUPPLY OF PVC/XLPE INSULATED ARMOURED CABLESSupply of aluminium onductor PVC/XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988. Make Havells,Polycab,Finolex,KEIOverall size 16sq.mm (4Core) Armoured( Incoming to SPN DB) |
| 251 | Overall size 70sq.mm (3.5Core) Armoured( Incoming from LT Panel) |
| 252 | SITC of Recess mounting low depth aesthetically designed LED 2\"x2\" flat panels to enhance the delight of occupants with comfortable experience through its classic design & glare free soft illumination. System Wattage36W with Minium 100 lumens/W in 5700k. The Fixture should be IP-65 of Makes :-PHILIPS/ BAJAJ(BCTBLR 36W LED FP CW) /CGL(LCTLRNE-36-FO-CDL)/GE/OSRAM/WIPRO/Havells(PLANO 2X2 PLR 36W LED 857 S) |
| 253 | SITC of 1500/1600/1650 VA UPS / INVERTER alongwith 2No 12V,150AH Batteries and trolly. Make Luminous/Exide/Amron |
| 254 | Supply, Installation, testing & commissioning of 1.5TR 3star Inverter type Split AC Unit |
| 255 | 1 run of Size 10 Sqmm(1/3.50 mm) 2x25( Sub Mains to 8 Way horizontal DB\"s =50 HSR-2123.3.6.5 |
| 256 | COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C(ceiling fan 2+Ex fan 16+1x18W Tube lights 70 + Wall Lights 4+ Mirror lights 15+ 2x2 Lights 6 =113-13-4=96HSR-23.4.1.3 |
| 257 | Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.Group C HSR-23.4.2.3 |
| 258 | Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch.Group C( Without Seprate Switch)(113-100+44=57)HSR-23.4.3.3 |
| 259 | Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required. Group C(for Light Plugs =4)HSR-23.4.4.3 |
| 260 | Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required. Group C(for Gyeser Points 15 + Power Plugs12=27) HSR-23.4.5.3 |
| 261 | Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall /ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work.PVC pipe of 20 mm dia.( For Misc Jobs )HSR-23.7.6.1 |
| 262 | PVC pipe of 25 mm dia. ( For Misc Jobs )HSR-23.7.6.2 |
| 263 | PVC pipe of 32 mm dia.(For Supply Cables) HSR-23.7.6.3 |
| 264 | PVC pipe of 40 mm dia.(For Supply Cables)HSR-23.7.6.4 |
| 265 | FITTING AND ACCESSORIESProviding and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessaryconnections, complete in all respect.Ceiling rose flush/surface type (For Ex fans)HSR-23.8.1.5 |
| 266 | Call bell 220/230 volts musical type HSR-23.8.1.6 |
| 267 | Bakelite angle/straight button holder large size.(For Bracket Lights4+ Mirror Lights 15=19)) HSR-23.8.1.12 |
| 268 | Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelitesheet as below75 mm x 75 mm x 60 mm deep M.S. box for inter-communication system HSR-23.8.3.1 |
| 269 | Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cmlong M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job.. |
| 270 | Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.1 & 2 Modules (For Misc Jobs) HSR-23.8.10.1 |
| 271 | 3 Modules(For Misc Jobs) HSR-23.8.10.2 |
| 272 | 4 Modules(For Misc Jobs) HSR-23.8.10.3 |
| 273 | 6 Modules(ForMisc Jobs) HSR-23.8.10.4 |
| 274 | 8 Modules (ForMisc Jobs) HSR-23.8.10.5 |
| 275 | Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. 5 amp 1 way switch (for plug on SB 24+7 =31)HSR-23.8.11.1 |
| 276 | 5 amp 2 way switch (Misc)HSR-23.8.11.2 |
| 277 | 15 amp 1 way switch )(Misc)HSR-23.8.11.3 |
| 278 | 5 amp Socket ( Plug on SB 24=24+7=31) HSR-23.8.11.4 |
| 279 | 15 amp 6 pin Socket( Misc)HSR-23.8.11.5 |
| 280 | Step type Fan Regulator 2 modules 300 wattHSR-23.8.11.7 |
| 281 | Blanking plateHSR-23.8.11.10 |
| 282 | Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work.HSR-21.23.9 |
| 283 | Making suitable hole in the wall suitable for exhaust fan up to 450 mm sweep including finishing the same and fixing of Stainless steel wire mesh 2 mm thick having about 50 meshes per inch at exhaust side complete as requiredHSR-21.23.11 |
| 284 | Providing and fixing outdoor duty Ply of 12 mm thick frame suitable for exhaust fan up to 450 mm sweep etc complete as required HSR-21.23.12 |
| 285 | Fixing of LED Tube light 1x18 / 2*2 ft square Lightfitting directly on wall /ceiling or falseceiling including making connections etc as required HSR-2123.20 |
| 286 | Supply and erection of sheet steel enclosures 1 pole/2 pole/4 pole on wall on existing pedestal complete as required S.P.N. or DP enclosure suitable for DP MCB( Misc) HSR-23.22.3.2 |
| 287 | TPN enclosure suitable for TP , TPN or FP MCB( Misc) HSR-23.22.3.3 |
| 288 | Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing)( For supply distribution at each floor)HSR-21.23.22.4.2 |
| 289 | Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:-6 amp. to 32 amp single pole. (For 8 way SPN DB,s)(2x6=12) HSR-23.22.5.1 |
| 290 | 40 amp. to 63 amp double pole.( For incoming of 8 way SPN DB,s)=2x1=2HSR-23.22.5.4 |
| 291 | Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. DP RCCB 30ma sensitivity , 40 A( For 8way SPNDB incomings 2x1=2) HSR-23.22.6.2 |
| 292 | Supply and erection of U- PVC Trunking/Channel of following size including cost of fixing on wall, floor and ceiling etc. with required material complete the job in all respect up to entire satisfaction of the Engineer-in-charge of work.25x 12 mm HSR-23.23.5.1 |
| 293 | 50x 50 mmHSR-23.23.5.4 |
| 294 | Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required.HSR-24.1.3 |
| 295 | Extra for charcoal or coke and salt for G. I. plate or copper plate earthelectrode.HSR-24.1.5 |
| 296 | Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess forconnections etc. as required with all labour and material.HSR-24.1.8 |
| 297 | Providing and fixing 4.00 mm dia G1. Wire on surface or in recess for loop earthing as required.HSR-24.1.13 |
| 298 | Laying of underground cable 0. 75 metre below ground level covered with sand and bricks including excavation and refilling of trenches.:- 50 Sq mm to 150 sqmm 2 to 4 Core HSR-24.2.2.3 |
| 299 | Laying and fixing of cable on surface/ cable tray etc as required:- 16 Sq mm to 35 sqmm 2 to 4 Core (Incoming to SPN DB)HSR-24.2.5.2 |
| 300 | Supply and erection of suitable compression type brass cable glands for underground Cable :-10 sqmm to 16s qmm Cable 2 to 4 CoreHSR-24.2.7.2 |
| 301 | 70 sqmm to 95 sqmm Cable 3 to 3½ CoreHSR-24.2.7.4 |
| 302 | Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work .16 sqmm HSR-24.2.8.4 |
| 303 | 70sqmmHSR-24.2.8.8 |
| 304 | S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Mtr below ground level includingdiging and refilling of earth including cost of suitable size socket/cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 90/75 mm outer dia/inner diaHSR-24.5.2.4 |
| 305 | SITCSurface MountedBracket/wall light . The Fixture should be Made of chrome&metal Housing.PF>.95, System Wattage 10Ww with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-BAJAJ (BCLSB10NW) / HAVELLS (LUMILINEBS10WLED 865 SPC WH / CGL (CCS-103-10-65-SL-DP-NWH)/GE/OSRAM /WIPRO/PHILIPS |
| 306 | SITC1x18W or 18/20W LED1200mm Batten Light. The Endura Fixture is a surface & wall mounted LED batten with extruded aluminium housing and robust construction . PF>.95, System Wattage LED 20W with Minium 1500 lumens in 5700k. The Fixture should be of Makes :-PHILIPS ( BN308C LED20S-6500 L120 PSU WH)/BAJAJ(BCLABSP22L LED CW PC SD) /GE/OSRAM/CGL/Havells ( LUMILINE SMART 20W LED 865PC WH). |
| 307 | SITC5/6/9W LEDaesthetically brillient surface picture/mirror light. The Fixture comprisesofaluminium /policarbonate . PF>.95, System Wattage LED 5/6/9W with Minium 100 lumens/W in 5700k . The Fixture should be of Makes :-BAJAJ(BCLSB 05 NW) /Havells(LUMILINE BS 9W LED 865 SPC WH) /CGL(CCS-103-05-65-SL-DP=NWH)/ GE/OSRAM/ PHILIPS etc.) |
| 308 | SUPPLY OF PVC/XLPE INSULATED ARMOURED CABLESSupply of aluminium onductor PVC/XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988. Make Havells,Polycab,Finolex,KEIOverall size 16sq.mm (4Core) Armoured( Incoming to SPN DB) |
| 309 | Overall size 70sq.mm (3.5Core) Armoured( Incoming from LT Panel) |
| 310 | SITC of Recess mounting low depth aesthetically designed LED 2\"x2\" flat panels to enhance the delight of occupants with comfortable experience through its classic design & glare free soft illumination. System Wattage36W with Minium 100 lumens/W in 5700k. The Fixture should be IP-65 of Makes :-PHILIPS/ BAJAJ(BCTBLR 36W LED FP CW) /CGL(LCTLRNE-36-FO-CDL)/GE/OSRAM/WIPRO/Havells(PLANO 2X2 PLR 36W LED 857 S) |
| 311 | SITC of 1500/1600/1650 VA UPS / INVERTER alongwith 2No 12V,150AH Batteries and trolly. Make Luminous/Exide/Amron |
| 312 | Supply, Installation, testing & commissioning of 1.5TR 3star Inverter type Split AC Unit |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy